Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Impot Res ; 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816575

RESUMEN

We aimed to determine the impact of the COVID-19 pandemic on search trends for inflatable penile implants in the US. Search trends for inflatable penile implants ranging from 2016 through 2023 were analyzed utilizing Google Trends. Associations between search trends and US Census Bureau data, including average household income and per capita income, were analyzed. Pre- and post- COVID-19, the interest in inflatable penile implants has been steadily increasing on average in the US. The average household income for counties with the highest interest in inflatable penile implants during the pre-COVID era was $53,136, whereas for the counties with the highest interest in inflatable penile implants in the post-COVID era, the average decreased to $50,940. Similarly, the average per capita median decreased from $35,209 to $34,547. Search traffic for inflatable penile prosthesis increased following the pandemic in the US. Nevertheless, post-pandemic, individuals with lower income levels showed no change in interest in penile implant searches compared to the pre-pandemic period. Understanding this steadiness in interest can inform healthcare professionals and policymakers to tailor interventions and educational efforts to reach a broader audience, ensuring equitable access to information and healthcare resources.

2.
Int J Impot Res ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38720138

RESUMEN

Ischemic priapism is a urological emergency which may lead to irreversible erectile dysfunction. One of the accepted treatments is penile prosthesis implantation. Given the scarcity of studies directly comparing timing of penile prosthesis insertion after ischemic priapism, consensus remains elusive. We aim to compare different studies in the literature concerning advantages and disadvantages of early versus delayed inflatable penile prosthesis following ischemic priapism. We analyzed 8 articles that investigated immediate and delayed inflatable penile prosthesis placement after ischemic priapism. Early inflatable penile prosthesis placement is associated with better outcomes, including pain relief, priapism resolution, penile shortening prevention, and quicker sexual activity resumption. However, it still carries a high risk of complications like edema, infection, and distal perforations. Delayed inflatable penile prosthesis insertion poses surgical challenges due to the potential for extensive corporal fibrosis. Comparative analyses have shown elevated complication rates in patients with ischemic priapism who undergo delayed inflatable penile prosthesis insertion, as opposed to those with early insertion. In studies reporting complications rates, the total complication rate in the early group was 3.37%, significantly lower than the delayed group (37.23%). Most studies support the superiority of early inflatable penile prosthesis placement following ischemic priapism over delayed placement. Further research is, however, needed to establish a global consensus on timing of prosthesis insertion.

4.
Sex Med Rev ; 12(2): 178-182, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38185910

RESUMEN

INTRODUCTION: Multiple sclerosis (MS) is a chronic autoimmune disease that affects the central nervous system and is widely recognized as a disease primarily affecting women. The relationship between MS and hypogonadism is complex and not fully understood, with recent evidence showing that hypogonadism may have a significant impact on the quality of life and disease progression of patients with MS. OBJECTIVES: This review aims to provide an overview of the current knowledge regarding the relationship between MS and hypogonadism, including the mechanisms underlying this relationship; the effects of hypogonadism on patients with MS; and the potential benefits and drawbacks of testosterone replacement therapy for patients with MS and hypogonadism. METHODS: This scientific review analyzed 19 articles that investigated the potential relationship among MS, testosterone levels, and hypogonadism. The articles were published between November 2008 and March 2022 and were identified through a comprehensive search of the PubMed database. The search terms used included "multiple sclerosis," "testosterone," "hypogonadism," and "MS and testosterone levels." RESULTS: Of the 19 articles reviewed, 11 described a positive correlation between low testosterone levels and dysfunction within the hypothalamic-pituitary-gonadal axis in individuals with MS. These findings suggest that low testosterone levels may contribute to dysfunction within the hypothalamus-pituitary-gonadal axis, which plays a crucial role in regulating testosterone production. The results also showed a relationship between sexual dysfunction and low testosterone levels, as well as a positive correlative relationship between these factors. CONCLUSION: The reviewed articles indicate a complex relationship among MS, testosterone levels, and the hypothalamic-pituitary-gonadal axis, with low testosterone levels potentially contributing to dysfunction in this axis and to sexual dysfunction. Further research is needed to better understand the effects of testosterone therapy on MS and sexual dysfunction in patients with MS.


Asunto(s)
Hipogonadismo , Esclerosis Múltiple , Disfunciones Sexuales Fisiológicas , Humanos , Femenino , Calidad de Vida , Esclerosis Múltiple/complicaciones , Hipogonadismo/complicaciones , Hipogonadismo/tratamiento farmacológico , Testosterona/uso terapéutico , Disfunciones Sexuales Fisiológicas/etiología
5.
Int J Impot Res ; 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37679463

RESUMEN

Implantation of penile prosthesis is considered when conservative measures fail or are unacceptable to patients' wishing treatment for erectile dysfunction. In the United States (US), inflatable penile prostheses are more often used than malleable penile prostheses (MPP). Outside the US, the reverse is true because third-party reimbursement is not available, and MPP is considerably cheaper. Two American manufacturers make MPP; presently, a new manufacturer, Rigicon (Ronkonkoma NY), has recently begun to sell its MPP worldwide. Patient information forms submitted to the manufacturer between March 1, 2019, and December 8, 2022, were used to conduct an initial safety study for 605 first-time patients implanted with Rigicon10® by 46 physicians in 15 countries with a mean follow-up of 21.6 months. It has the same configuration of trimmable, paired silicone rods containing a twisted stainless-steel wire for bendability. However, it is available in six widths with hydrophilic coating compared to three widths offered by competitors. Revision or explantation was needed in 6 of 605 patients (0.99%) with half of those being removed for dissatisfaction (0.50%). Two (0.33%) suffered device infection and one (0.16%) required removal for erosion. Kaplan-Meier's statistical analysis showed three-year implant survival from revision = 99.2%. It demonstrated a comparable safety record with less than 1.00% of patients requiring reoperation.

7.
Urology ; 180: 257-261, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37517678

RESUMEN

OBJECTIVE: To report the incidence of the reoperation surgeries of nearly all the Rigicon Infla10 implants performed since device introduction in 1/2019. Inflatable penile prosthesis has some of the highest survival from revision surgery of any medical device implanted in humans [1]. We expand on previous Rigicon Infla10 research, adding more patients and increasing follow-up duration [2]. MATERIALS AND METHODS: 535 patients had Rigicon Infla10 devices implanted from 1/2019 to 8/2022. 103 surgeons from 26 centers in 15 countries participated in the study. Patient information forms were analyzed from virtually all implantations. Explantation or revision surgery for mechanical failure, infection, other medical reasons, and patient dissatisfaction were cataloged. SPSS 25.0 (IBM) was used for the statistical analysis of Kaplan Meier survival statistics. RESULTS: Mean follow-up was 24.2months (7-43months). Mean patient age was 56years. Reoperation was necessary for 3.5% of subjects. Revision for mechanical failure occurred in 2.24% (12/535). The rate of explant for patient dissatisfaction was 0.56% (3/535). Revision for component out of place was 0.37% (2/535) with an infection rate and unsuccessful Peyronie's correction being 0.19% (1/535). Survival from requiring another corrective surgery at 1, 2, and 3years was 96.4%, 95.0%, and 94.0%, respectively. These initial survival rates compare favorably to devices currently available, which have been repeatedly enhanced to improve reliability. CONCLUSION: In its first 2-3years of availability, The Rigicon Infla10 inflatable penile prosthesis shows freedom from revision comparable to existing enhanced devices that have been on the market for decades.


Asunto(s)
Disfunción Eréctil , Implantación de Pene , Prótesis de Pene , Humanos , Persona de Mediana Edad , Masculino , Prótesis de Pene/efectos adversos , Reoperación , Reproducibilidad de los Resultados , Implantación de Pene/efectos adversos , Disfunción Eréctil/etiología , Satisfacción del Paciente , Estudios Retrospectivos , Diseño de Prótesis , Falla de Prótesis
8.
Urol Pract ; 10(4): 415, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37276374
9.
Transl Androl Urol ; 12(5): 859-865, 2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37305641

RESUMEN

Background: In 2017, a prospective multicenter, multinational, investigational pilot study was conducted examining outcomes using a novel surgical technique, the Mini-Jupette sling, for the management of erectile dysfunction (ED) patients with climacturia and/or minimal stress urinary incontinence (SUI) after prostate procedures. Climacturia has been reported in up to 64% of patients following radical prostatectomy (RP). We sought to report the 5-year outcomes from this original cohort to assess long-term safety and effectivity of the mini-jupette sling in the treatment of ED and concomitant mild SUI and/or climacturia. Methods: This is a single-arm, multicenter, retrospective, observational study. We identified patients who were enrolled in the previous multicenter study with post-RP ED and climacturia and/or mild SUI- 2 PADS PER DAY (PPD) and underwent inflatable penile prosthesis (IPP) insertion with simultaneous placement of a mini-jupette sling. Data were collected including current PPD, subjective improvement in climacturia/SUI, complications, need for revision of IPP or additional urinary incontinence surgery, and date of most recent follow-up. SPSS was used for statistical analysis. Results: Of the original 38 patients, 5 have since died and 10 were lost to follow-up with 23/38 (61%) patients available for evaluation of long-term outcomes. The average follow-up time was 59 months (SD =8.8) with a mean age of 69 years (SD =6.8). Most patients (n=21, 91%) had subjective improvement of SUI and climacturia. One patient with persistent bothersome incontinence underwent artificial urinary sphincter (AUS) placement in 2018 with no complications, while the other is still considering a repeat procedure due to minor but persistent SUI. The mean PPD decreased from 1.4 preoperatively to 0.4 at a mean of 5 years of follow-up. Most patients reported satisfaction in their urinary symptoms with 91% and 73% reporting improvement in SUI and climacturia respectively, compared to 86% and 93% respectively in the original series. One (4.3%) patient had an IPP revision for pump malfunction. There were no device infections reported. Conclusions: The mini-jupette sling appears to be a safe and effective procedure with durable improvements in SUI and climacturia at 5 years of follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...