Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
Med Image Anal ; 99: 103323, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39243597

RESUMEN

Simulation of the dynamic behavior of mitral valve closure could improve clinical treatment by predicting surgical procedures outcome. We propose here a method to achieve this goal by using the immersed boundary method. In order to go towards patient-based simulation, we tailor our method to be adapted to a valve extracted from medical image data. It includes investigating segmentation process, smoothness of geometry, case setup and the shape of the left ventricle. We also study the influence of leaflet tissue anisotropy on the quality of the valve closure by comparing with an isotropic model. As part of the anisotropy analysis, we study the influence of the principal material direction by comparing methods to obtain them without dissection. Results show that our method can be scaled to various image-based data. We evaluate the mitral valve closure quality based on measuring bulging area, contact map, and flow rate. The results show also that the anisotropic material model more precisely represents the physiological characteristics of the valve tissue. Furthermore, results indicate that the orientation of the principal material direction plays a role in the effectiveness of the valve seal.

2.
Ann Biomed Eng ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39107489

RESUMEN

PURPOSE: Valve-sparing root replacement (VSRR) is attractive for aortic root dilation as it preserves the native aortic valve (AoV). Low effective height (eH) after reconstruction is a risk factor for repair failure and reoperation. We developed and validated a quantitative AoV repair strategy to reliably restore normal valve proportions to promote long-term function. METHODS: Normal AoV proportions were used to derive geometric relationships for sinotubular junction diameter (DSTJ), free edge length (FEL), free edge angle, and commissure height. These relationships informed two models for predicting eH following VSRR: (1) assuming valve symmetry and (2) accounting for valve asymmetry. Porcine heart (n = 6) ex vivo validation was performed under 4 VSRR scenarios: "Ideal" (tube graft size targeting FEL/DSTJ = 1.28), "Oversized" (one graft size larger than Ideal), "Undersized" (two sizes smaller), and "Undersized + Plicated" (FEL/DSTJ = 1.28 restored with leaflet plication). RESULTS: Our analytical models predicted eH using preoperative measurements and estimated reconstructed dimensions. The Oversized graft exhibited similar eH to Ideal but higher regurgitation in the ex vivo model, whereas the Undersized graft demonstrated lower eH and regurgitation. Plication in the Undersized graft restored valve function (regurgitation & eH) similar to Ideal in the ex vivo model and above Ideal in the analytical models. Both analytical models predicted ex vivo eH well except in the Oversized and Undersized + Plicated conditions. CONCLUSION: Utilizing measurements from preoperative imaging and simple mathematical models, patient-specific operative plans for VSRR can be created by estimating valve dimensions necessary to achieve favorable valve features post-repair. Clinical application of this approach promises to improve consistency in achieving optimal long-term dimensions and durability.

3.
JACC Adv ; 3(7): 101057, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39129987

RESUMEN

Background: Single ventricle (SV) patients with interrupted inferior vena cava (iIVC) and azygos continuation are at high risk for unbalanced hepatic venous flow (HVF) distribution to the lungs after Fontan completion and subsequent pulmonary arteriovenous malformations (AVMs) formation. Objectives: The aim of the study was to utilize computational fluid dynamics (CFD) analysis to avoid maldistribution of HVF to the lungs after Fontan surgery. Methods: Four SV subjects with iIVC were prospectively studied with a 3-dimensional (3D) modeling workflow with digital 3D models created from segmented magnetic resonance images or computer tomography scans, virtual surgery, and CFD analysis over multiple physiologic states for the evaluation of operative plans to achieve balanced HVF to both lungs. Three of the patients were Fontan revision candidates with existing AVMs. All patients underwent Fontan completion or revision surgery. Results: CFD predicted that existing or proposed Fontan completion in all patients would result in 100% of HVF to one lung. Improved HVF balance was achieved with CFD analysis of alternative surgical approaches resulting in the average distribution of HVF to the right/left pulmonary arteries of 37%/63% ± 10.4%. A hepatoazygos shunt was required in all patients and additional creation of an innominate vein in one. CFD analysis was validated by the comparison of pre-operative predicted and postoperative MRI-measured total right/left pulmonary flow (51%/49% ± 5.4% vs 49%/51% ± 8.5%). Conclusions: A 3D modeling workflow with CFD simulation for SV patients with iIVC may avoid HVF maldistribution and development of AVMs after Fontan completion.

4.
Chemosphere ; 362: 142558, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38851513

RESUMEN

The contamination of water bodies by synthetic organic compounds coupled with climate change and the growing demand for water supply calls for new approaches to water management and treatment. To tackle the decontamination issue, the activation of peroxymonosulfate (PMS) using copper magnetic ferrite (CuMF) nanoparticles prepared under distinct synthesis conditions was assessed to oxidize imidacloprid (IMD) insecticide. After optimization of some operational variables, such as CuMF load (62.5-250 mg L-1), PMS concentration (250-1000 µM), and solution pH (3-10), IMD was completely oxidized in 2 h without interferences from leached metal ions. Such performance was also achieved when using tap water but was inhibited by a simulated municipal wastewater due to scavenging effects promoted by inorganic and organic species. Although there was evidence of the presence of sulfate radicals and singlet oxygen oxidizing species, only four intermediate compounds were detected by liquid chromatography coupled to mass spectrometry analysis, mainly due to hydroxyl addition reactions. Concerning the changes in surface properties of CuMF after use, no morphological or structural changes were observed except a small increase in the charge transfer resistance. Based on the changes of terminal surface groups, PMS activation occurred on Fe sites.


Asunto(s)
Cobre , Insecticidas , Neonicotinoides , Nitrocompuestos , Oxidación-Reducción , Peróxidos , Contaminantes Químicos del Agua , Insecticidas/química , Neonicotinoides/química , Nitrocompuestos/química , Contaminantes Químicos del Agua/química , Cobre/química , Peróxidos/química , Compuestos Férricos/química , Aguas Residuales/química , Purificación del Agua/métodos , Nanopartículas/química , Compuestos Ferrosos
7.
Circ Cardiovasc Imaging ; 17(4): e016104, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38567518

RESUMEN

BACKGROUND: The Fontan operation is a palliative technique for patients born with single ventricle heart disease. The superior vena cava (SVC), inferior vena cava (IVC), and hepatic veins are connected to the pulmonary arteries in a total cavopulmonary connection by an extracardiac conduit or a lateral tunnel connection. A balanced hepatic flow distribution (HFD) to both lungs is essential to prevent pulmonary arteriovenous malformations and cyanosis. HFD is highly dependent on the local hemodynamics. The effect of age-related changes in caval inflows on HFD was evaluated using cardiac magnetic resonance data and patient-specific computational fluid dynamics modeling. METHODS: SVC and IVC flow from 414 patients with Fontan were collected to establish a relationship between SVC:IVC flow ratio and age. Computational fluid dynamics modeling was performed in 60 (30 extracardiac and 30 lateral tunnel) patient models to quantify the HFD that corresponded to patient ages of 3, 8, and 15 years, respectively. RESULTS: SVC:IVC flow ratio inverted at ≈8 years of age, indicating a clear shift to lower body flow predominance. Our data showed that variation of HFD in response to age-related changes in caval inflows (SVC:IVC, 2, 1, and 0.5 corresponded to ages, 3, 8, and 15+, respectively) was not significant for extracardiac but statistically significant for lateral tunnel cohorts. For all 3 caval inflow ratios, a positive correlation existed between the IVC flow distribution to both the lungs and the HFD. However, as the SVC:IVC ratio changed from 2 to 0.5 (age, 3-15+) years, the correlation's strength decreased from 0.87 to 0.64, due to potential flow perturbation as IVC flow momentum increased. CONCLUSIONS: Our analysis provided quantitative insights into the impact of the changing caval inflows on Fontan's long-term HFD, highlighting the importance of SVC:IVC variations over time on Fontan's long-term hemodynamics. These findings broaden our understanding of Fontan hemodynamics and patient outcomes.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Humanos , Preescolar , Niño , Adolescente , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía , Vena Cava Superior/fisiología , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Hígado/diagnóstico por imagen , Hemodinámica/fisiología , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía
8.
Materials (Basel) ; 17(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38673250

RESUMEN

This study investigates the profound impact of the ZrO2 inclusion volume on the characteristics of Al2O3/ZrO2 nanocomposites, particularly influencing the formation of calcium phosphates on the surface. This research, aimed at advancing tissue engineering, prepared nanocomposites with 5, 10, and 15 vol% ZrO2, subjecting them to chemical surface treatment for enhanced calcium phosphate deposition sites. Biomimetic coating with Sr-enriched simulated body fluid (SBF) further enhanced the bioactivity of nanocomposites. While the ZrO2 concentration heightened the oxygen availability on nanocomposite surfaces, the quantity of Sr-containing phosphate was comparatively less influenced than the formation of calcium phosphate phases. Notably, the coated nanocomposites exhibited a high cell viability and no toxicity, signifying their potential in bone tissue engineering. Overall, these findings contribute to the development of regenerative biomaterials, holding promise for enhancing bone regeneration therapies.

9.
World J Pediatr Congenit Heart Surg ; 15(3): 371-379, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38327093

RESUMEN

BACKGROUND: Restoring adequate coaptation height is a key principle of mitral valve (MV) repair. This study aimed to evaluate the utility of fiberscope (FS) technology to assess MV coaptation height for intraoperative use. METHODS: Ex-vivo testing was performed on five adult porcine hearts. The left atrium (LA) was resected, and the left ventricle (LV) was pressurized retrograde to 27 ± 1mm Hg. An endoscope was inserted into the LV apex, centered under the MV orifice. An FS system (Milliscope II camera, LED light source, and 0.7 mm diameter × 15 cm long) 90° semirigid scope with 1.2 mm focal length) was mounted above the MV annulus in a custom alignment and measuring fixture. Three blinded measurements were taken at two locations on each MV, A2 and P2 segment, from the top of coaptation to the leaflet edge identified by the FS. Accurate positioning was verified using the LV endoscope. A control (metal rod of similar thickness) was used for comparison, with coaptation height recorded when the control was seen via the endoscope. RESULTS: Coaptation heights were similar for the control and FS methods across all hearts at A2 (11.6 ± 2.6 mm control vs 11.8 ± 2.2 mm FS) and P2 (13.3 ± 2.6 mm control vs 13.4 ± 2.9 mm FS) segments, with similar measurement variability (control SD 0.1-1.0 mm; FS SD 0.1-0.9 mm). One outlier was excluded from analysis (n = 19/20). The maximum absolute difference and percent error between measurement methods were less than 1.1 mm (median [IQR], 0.6 [0.3-0.9] mm) and less than 14% (4.1 [2.2-7.6]%). CONCLUSIONS: Utilization of a miniaturized FS enabled precise and accurate quantification of MV coaptation. This technique is promising for evaluating post-repair valve competence and coaptation height.


Asunto(s)
Válvula Mitral , Animales , Porcinos , Válvula Mitral/cirugía , Diseño de Equipo , Modelos Animales de Enfermedad , Endoscopía/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Tecnología de Fibra Óptica
10.
Chemosphere ; 352: 141278, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38266880

RESUMEN

Nanometric cobalt magnetic ferrite (CoFe2O4) synthesized by distinct methods was used for in situ chemical activation of peroxymonosulfate (PMS) under neutral conditions to oxidize imidacloprid (IMD) insecticide. The effect of CoFe2O4 load (0.125-1.0 g L-1) and PMS concentration (250-1000 µM) was investigated as well as the influence of phosphate buffer and Co(II) ions. PMS activation by Co(II) ions, including those leached from CoFe2O4 (>50 µg L-1), exhibited a strong influence on IMD oxidation and, apparently, without substantial contributions from the solid phase. Within the prepared solid materials (i.e., using sol-gel and co-precipitation methods), high oxidation rates (ca. 0.5 min-1) of IMD were attained in ultrapure water. Phosphate buffer had no significant influence on the IMD oxidation rate and level, however, its use and solution pH have shown to be important parameters, since higher PMS consumption was observed in the presence of buffered solutions at pH 7. IMD byproducts resulting from hydroxylation reactions and rupture of the imidazolidine ring were detected by mass spectrometry. At optimum conditions (0.125 g L-1 of CoFe2O4 and 500 µM of PMS), the CoFe2O4 nanoparticles exhibited an increase in the charge transfer resistance and an enhancement in the surface hydroxylation after PMS activation, which led to radical (HO● and SO4●-) and nonradical (1O2) species. The latter specie led to high levels of IMD oxidation, even in a complex water matrix, such as simulated municipal wastewater at the expense of one-order decrease in the IMD oxidation rate.


Asunto(s)
Cobalto , Compuestos Férricos , Insecticidas , Neonicotinoides , Nitrocompuestos , Peróxidos/química , Agua , Fosfatos
11.
Cardiovasc Eng Technol ; 14(6): 827-839, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37973699

RESUMEN

PURPOSE: Pulmonary valve (PV) monocusp reconstruction in transannular patch (TAP) right ventricular outflow tract (RVOT) repair for Tetralogy of Fallot has variable clinical outcomes across different surgical approaches. The study purpose was to systematically evaluate how monocusp leaflet design parameters affect valve function in-vitro. METHODS: A 3D-printed, disease-specific RVOT model was tested under three infant physiological conditions. Monocusps were sewn into models with the native main pulmonary artery (MPA) forming backwalls that constituted 40% and 50% of the reconstructed circumference for z-score zero PV annulus and MPA diameters (native PV z-score - 3.52 and - 2.99 for BSA 0.32m2). Various leaflet free edge lengths (FEL) (relative to backwall), positions (relative to PV STJ), and scallop depths were investigated across both models. Pressure gradient, regurgitation, and coaptation were analyzed with descriptive statistics and regression models. RESULTS: Increasing FEL beyond 100% of the MPA backwall decreased gradient but mildly increased regurgitation to a peak of 25%. Positioning the free edge 2 mm past the STJ mildly increased gradient for each FEL without significantly changing regurgitation compared to STJ placement. Scalloping leaflets trivially affected performance. Pre-folding leaflets improved mobility and slightly reduced gradient. CONCLUSIONS: Balancing gradient, regurgitation, and oversizing for growth, a set of leaflet designs have been selected for pre-clinical evaluation. Designs with leaflet widths 140-160% in the 40% backwall model (110-120% in the 50% backwall), positioned at or 2 mm past the STJ, demonstrated the best results. The next stage of ex-vivo testing will additionally consider native RVOT distensibility, native leaflet interactions, and TAP characteristics.


Asunto(s)
Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Tetralogía de Fallot , Lactante , Humanos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Ventrículos Cardíacos , Politetrafluoroetileno , Resultado del Tratamiento , Estudios Retrospectivos
12.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37897688

RESUMEN

OBJECTIVES: Thick-patch pulmonary homograft, autologous pericardium and CardioCel Neo are common patch materials for aortic arch reconstruction. Insufficient data exist on sutured patch strength and limits of use. We evaluated failure strength of these materials to develop a failure prediction model for clinical guidance. METHODS: Patch failure strength was evaluated via sutured uniaxial and burst pressure testing. In sutured uniaxial testing, patches were sutured to aortic or Dacron tabs and pulled to failure. In burst pressure testing, patches were sewn into porcine aortas or Dacron grafts and pressurized to failure. Failure membrane tension was calculated. A prediction model of membrane tension versus vessel diameter was generated to guide clinical patch selection. RESULTS: Combining sutured uniaxial and burst pressure test data, pulmonary homograft failure strength {0.61 [interquartile range (IQR): 0.44, 0.78] N/mm, n = 21} was less than half that of autologous pericardium [2.22 (IQR: 1.65, 2.78) N/mm, n = 15] and CardioCel Neo [1.31 (IQR: 1.20, 1.42) N/mm, n = 20]. Pulmonary homograft burst pressure [245 (IQR: 202, 343) mmHg, n = 7] was significantly lower than autologous pericardium [863 (IQR: 802, 919) mmHg, n = 6] and CardioCel Neo [766 (IQR: 721, 833) mmHg, n = 6]. Our model predicts failure limits for each patch material and outlines safety margins for combinations of aortic diameter and pressure. CONCLUSIONS: Sutured failure strength of thick-patch pulmonary homograft was significantly lower than autologous pericardium and CardioCel Neo. Patient selection (predicted postoperative arch diameter and haemodynamics) and blood pressure management must be considered when choosing patch material for arch reconstruction. In older children and adolescents, autologous or bovine pericardium may be more suitable materials for aortic patch augmentation to minimize the risk of postoperative patch failure.


Asunto(s)
Aorta Torácica , Tereftalatos Polietilenos , Niño , Humanos , Animales , Bovinos , Porcinos , Adolescente , Aorta Torácica/cirugía , Aorta , Presión Sanguínea , Hemodinámica , Pericardio/trasplante , Estudios Retrospectivos
13.
Sci Adv ; 9(43): eadi5559, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37878705

RESUMEN

In minimally invasive endovascular procedures, surgeons rely on catheters with low dexterity and high aspect ratios to reach an anatomical target. However, the environment inside the beating heart presents a combination of challenges unique to few anatomic locations, making it difficult for interventional tools to maneuver dexterously and apply substantial forces on an intracardiac target. We demonstrate a millimeter-scale soft robotic platform that can deploy and self-stabilize at the entrance to the heart, and guide existing interventional tools toward a target site. In two exemplar intracardiac procedures within the right atrium, the robotic platform provides enough dexterity to reach multiple anatomical targets, enough stability to maintain constant contact on motile targets, and enough mechanical leverage to generate newton-level forces. Because the device addresses ongoing challenges in minimally invasive intracardiac intervention, it may enable the further development of catheter-based interventions.


Asunto(s)
Robótica , Catéteres , Atrios Cardíacos , Diseño de Equipo
14.
Cardiovasc Eng Technol ; 14(5): 640-654, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37580629

RESUMEN

PURPOSE: Very high-risk, ductal-dependent or complex two-ventricle patients with associated comorbidities often require pulmonary blood flow restriction as bridge to a more definitive procedure, but current surgical options may not be well-tolerated. An evolving alternative utilizes a fenestrated Micro Vascular Plug (MVP) as a transcatheter, internal pulmonary artery band. In this study, we report a case series and an in-vitro evaluation of the MVP to elicit understanding of the challenges faced with device implantation. METHODS: Following single-center, retrospective review of eight patients who underwent device placement, an in-vitro flow study was conducted on MVP devices to assess impact of device and fenestration sizing on pulmonary blood flow. A mathematical model was developed to relate migration risk to vessel size. Results of the engineering analysis were compared to the clinical series for validation. RESULTS: At median follow-up of 8 months (range 1-15), survival was 63% (5/8), and 6 (75%) patients underwent subsequent target surgical intervention with relatively low mortality (1/6). Occluder-related challenges included migration (63%) and peri-device flow, which were evaluated in-vitro. The device demonstrated durability over normal and supraphysiologic conditions with minimal change in fenestration size. Smaller vessel size significantly increased pressure gradient due to reduced peri-device flow and smaller effective fenestration size. CONCLUSION: Device oversizing, with appropriate adjustment to fenestration size, may reduce migration risk and provide a clinically appropriate balance between resulting pressure gradient and Qp:Qs. Our results can guide the interventionalist in appropriately selecting the device and fenestrations based on patient-specific anatomy and desired post-implantation flow characteristics.


Asunto(s)
Cateterismo Cardíaco , Arteria Pulmonar , Recién Nacido , Humanos , Arteria Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
15.
Artículo en Inglés | MEDLINE | ID: mdl-37555820

RESUMEN

OBJECTIVES: Reconstruction of cardiovascular anatomy with patch material is integral to the repair of congenital heart disease. We present validation of a laser projection platform for the preparation of surgical patches as a proof-of-concept for intraoperative use in patient-specific planning of paediatric cardiac surgery reconstructions. METHODS: The MicroLASERGUIDE, a compact laser projection system that displays computer-aided designs onto 2D/3D surfaces, serves as an alternative to physical templates. A non-inferiority comparison of dimensional measurements was conducted between laser projection ('laser') and OZAKI AVNeo Template ('template') methods in creation of 51 (each group) size 13 valve leaflets from unfixed bovine pericardium. A digital version of the OZAKI AVNeo Template dimensions served as control. Feasibility testing was performed with other common patch materials (fixed bovine pericardium, PTFE and porcine main pulmonary artery as a substitute for pulmonary homograft) and sizes (13, 23) (n = 3 each group). RESULTS: Compared to control (height 21.5, length 21.0 mm), template height and length were smaller (height and length differences of -0.3 [-0.5 to 0.0] and -0.4 [-0.8 to -0.1] mm, P < 0.01 each); whereas, both laser height and length were relatively similar (height and length differences of height 0.0 [-0.2 to 0.2], P = 0.804, and 0.2 [-0.1 to 0.4] mm, P = 0.029). Template percent error for height and length was -1.5 (-2.3 to 0.0)% and -1.9 (-3.7 to -0.6)% vs 0.2 (-1.0 to 1.1)% and 1.0 (-0.5 to 1.8)% for the laser. Similar results were found with other materials and sizes. Overall, laser sample dimensions differed by a maximum of 5% (∼1 mm) from the control. CONCLUSIONS: The laser projection platform has demonstrated promise as an alternative methodology for the preparation of surgical patches for use in cardiac surgery. This technology has potential to revolutionize preoperative surgical planning for numerous congenital anomalies that require patient-specific patch-augmented repair.

16.
J Trauma Acute Care Surg ; 95(2): 186-190, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37068024

RESUMEN

BACKGROUND: Rapid triage of blunt agonal trauma patients is necessary to maximize survival, but autopsy is uncommon, slow, and rarely informs resuscitation guidelines. Postmortem computed tomography (PMCT) can serve as an adjunct to autopsy in guiding blunt agonal trauma resuscitation. METHODS: Retrospective cohort review of trauma decedents who died at or within 1 hour of arrival following blunt trauma and underwent noncontrasted PMCT. Primary outcome was the prevalence of mortal injury defined as potential exsanguination (e.g., cavitary injury, long bone and pelvic fractures), traumatic brain injury, and cervical spine injury. Secondary outcomes were potentially mortal injuries (e.g., pneumothorax) and misplacement airway devices. Patients were grouped by whether arrest occurred prehospital/in-hospital. Univariate analysis was used to identify differences in injury patterns including multiple-trauma injury patterns. RESULTS: Over a 9-year period, 80 decedents were included. Average age was 48.9 ± 21.7 years, 68% male, and an average ISS of 42.3 ± 16.3. The most common mechanism was motor vehicle accidents (67.5%) followed by pedestrian struck (15%). Of all decedents, 62 (77.5%) had traumatic arrest prehospital while 18 (22.5%) arrived with pulse. Between groups there were no significant differences in demographics including ISS. The most common mortal injuries were traumatic brain injury (40%), long bone fractures (25%), moderate/large hemoperitoneum (22.5%), and cervical spine injury (25%). Secondary outcomes included moderate/large pneumothorax (18.8%) and esophageal intubation rate of 5%. There were no significant differences in mortal or potentially mortal injuries, and no differences in multiple-trauma injury patterns. CONCLUSION: Fatal blunt injury patterns do not vary between prehospital and in-hospital arrest decedents. High rates of pneumothorax and endotracheal tube misplacement should prompt mandatory chest decompression and confirmation of tube placement in all blunt arrest patients. LEVEL OF EVIDENCE: Prognostic and Epidemiological; Level IV.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Traumatismo Múltiple , Neumotórax , Traumatismos Torácicos , Heridas no Penetrantes , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Estudios Retrospectivos , Neumotórax/diagnóstico por imagen , Neumotórax/epidemiología , Neumotórax/etiología , Heridas no Penetrantes/complicaciones , Traumatismo Múltiple/complicaciones , Lesiones Traumáticas del Encéfalo/complicaciones , Tomografía , Traumatismos Torácicos/complicaciones
17.
Cardiovasc Eng Technol ; 14(2): 217-229, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36456745

RESUMEN

PURPOSE: Tetralogy of Fallot and other conditions affecting the right ventricular outflow tract (RVOT) are common in pediatric patients, but there is a lack of quantitative comparison among techniques for repairing or replacing the pulmonary valve. The aim of this study was to develop a robust in vitro system for quantifying flow conditions after various RVOT interventions. METHODS: An infant-sized mock circulatory loop that includes a 3D-printed RVOT anatomical model was developed to evaluate flow conditions after different simulated surgical repairs. Physiologically correct flow and pressure were achieved with custom compliant tubing and a tunable flow restrictor. Pressure gradient, flow regurgitation, and coaptation height were measured for two monocusp leaflet designs after tuning the system with a 12 mm Hancock valved conduit. RESULTS: Measurements were repeatable across multiple samples of two different monocusp designs, with the wider leaflet in the 50% backwall model consistently exhibiting lower pressure gradient but higher regurgitation compared to the leaflet in the 40% backwall model. Coaptation height was measured via direct visualization with endoscopic cameras, revealing a shorter area of contact for the wider leaflet (3.3-4.0 mm) compared to the narrower one (4.3 mm). CONCLUSION: The 3D-printed RVOT anatomical model and in vitro pulmonary circulatory loop developed in this work provide a platform for planning and evaluating surgical interventions in the pediatric population. Measurements of regurgitation, pressure gradient, and coaptation provide a quantitative basis for comparison among different valve designs and positions.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvula Pulmonar , Tetralogía de Fallot , Obstrucción del Flujo Ventricular Externo , Lactante , Niño , Humanos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Ventrículos Cardíacos , Circulación Pulmonar , Resultado del Tratamiento
18.
J Patient Saf Risk Manag ; 28(5): 208-214, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38405201

RESUMEN

Background: Medical errors occur frequently, yet they are often under-reported and strategies to increase the reporting of medical errors are lacking. In this work, we detail how a level 1 trauma center used a secure messaging application to track medical errors and enhance its quality improvement initiatives. Methods: We describe the formulation, implementation, evolution, and evaluation of a chatroom integrated into a secure texting system to identify performance improvement and patient safety (PIPS) concerns. For evaluation, we used descriptive statistics to examine PIPS reporting by the reporting method over time, the incidence of mortality and unplanned ICU readmissions tracked in the hospital trauma registry over the same, and time-to-loop closure over the study period to quantify the impact of the processes instituted by the PIPS team. We also categorized themes of reported events. Results: With the implementation of a PIPS chatroom, the number of events reported each month increased and texting became the predominant way for users to report trauma PIPS events. This increase in PIPS reporting did not appear to be accompanied by an increase in mortality and unplanned ICU readmissions. The PIPS team also improved the tracking and timely resolution of PIPS events and observed a decrease in time-to-loop closure with the implementation of the PIPS chatroom. Conclusions: The adoption of clinical texting as a way to report PIPS events was associated with increased reporting of such events and more timely resolution of concerns regarding patient safety and healthcare quality.

19.
Polymers (Basel) ; 14(17)2022 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-36080551

RESUMEN

Reinforcement steel extensively applied in civil construction is susceptible to corrosion due to the carbonation process in reinforced concrete and chloride ions diffusion. Epoxy-silica-based coatings are a promising option to guarantee the long-term stability of reinforced concrete structures. In this study, the influence of the proportion between the poly (bisphenol-A-co-epichlorhydrin) resin (DGEBA) and the curing agent diethylenetriamine (DETA) on the structural, morphological, and barrier properties of epoxy-silica nanocomposites were evaluated. To simulate different stages of concrete aging, electrochemical impedance spectroscopy (EIS) assays were performed for coated samples in a 3.5 wt.% NaCl solution (pH 7) and in simulated concrete pore solutions (SCPS), which represent the hydration environment in fresh concrete (SCPS2, pH 14) and after carbonation (SCPS1, pH 8). The results showed that coatings with an intermediate DETA to DGEBA ratio of 0.4, presented the best long-term corrosion protection with a low-frequency impedance modulus of up to 3.8 GΩ cm2 in NaCl and SCPS1 solutions. Small-angle X-ray scattering and atomic force microscopy analysis revealed that the best performance observed for the intermediate DETA proportion is associated with the presence of larger silica nanodomains, which act as a filler in the cross-linked epoxy matrix, thus favoring the formation of an efficient diffusion barrier.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA