Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
J Pers Med ; 14(4)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38673028

RESUMEN

The aim of this study was to evaluate treatment of osteoid osteomas using bipolar radiofrequency ablation (RFA) and patients' quality of life before and after therapy. We retrospectively evaluated patients who underwent bipolar RFA of osteoid osteomas between 2001 and 2016. We assessed patients' symptoms before and after treatment (four weeks after treatment and long-term) using a questionnaire including severity and quality of pain on a 10-point scale (1 = no pain, 10 = severe pain), motion restrictions, pain-related sleep disorders, and necessary pain medication. In addition, we evaluated technical success, complications, hospitalization length, and patients' satisfaction with treatment. This study included 62 patients (43 [69.4%] males, 26.2 ± 13.2 years). Average nidus size was 5.7 ± 2.6 mm. The rate of technical success was 100%. All RFAs were performed without any complications. One patient showed a recurrence, resulting in a recurrence rate of 1.6%, which was successfully treated by another session of RFA. Average hospitalization length was 1.5 ± 0.5 days. A total of 36 patients (58.1%) participated in the questionnaire, reporting an average pain severity of 8.2 ± 1.6 before RFA compared to 3.4 ± 3.0 four weeks after and an average of 2.1 ± 2.3, 6.6 years after therapy, (both p < 0.001). After therapy, 31 (86.1%) patients had no pain. The majority of patients (n = 34, 94.4%) had reduced or absent motion restriction after therapy (p < 0.001). Patient satisfaction rate was 91.7%. In conclusion, bipolar RFA is a safe and effective treatment modality for osteoid osteomas and improves quality of life by reducing pain severity and motion restrictions.

2.
Eur J Clin Invest ; 53(12): e14075, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37571983

RESUMEN

BACKGROUND: To investigate the potential of radiomic features and dual-source dual-energy CT (DECT) parameters in differentiating between benign and malignant mediastinal masses and predicting patient outcomes. METHODS: In this retrospective study, we analysed data from 90 patients (38 females, mean age 51 ± 25 years) with confirmed mediastinal masses who underwent contrast-enhanced DECT. Attenuation, radiomic features and DECT-derived imaging parameters were evaluated by two experienced readers. We performed analysis of variance (ANOVA) and Chi-square statistic tests for data comparison. Receiver operating characteristic curve analysis and Cox regression tests were used to differentiate between mediastinal masses. RESULTS: Of the 90 mediastinal masses, 49 (54%) were benign, including cases of thymic hyperplasia/thymic rebound (n = 10), mediastinitis (n = 16) and thymoma (n = 23). The remaining 41 (46%) lesions were classified as malignant, consisting of lymphoma (n = 28), mediastinal tumour (n = 4) and thymic carcinoma (n = 9). Significant differences were observed between benign and malignant mediastinal masses in all DECT-derived parameters (p ≤ .001) and 38 radiomic features (p ≤ .044) obtained from contrast-enhanced DECT. The combination of these methods achieved an area under the curve of .98 (95% CI, .893-1.000; p < .001) to differentiate between benign and malignant masses, with 100% sensitivity and 91% specificity. Throughout a follow-up of 1800 days, a multiparametric model incorporating radiomic features, DECT parameters and gender showed promising prognostic power in predicting all-cause mortality (c-index = .8 [95% CI, .702-.890], p < .001). CONCLUSIONS: A multiparametric approach combining radiomic features and DECT-derived imaging biomarkers allows for accurate and noninvasive differentiation between benign and malignant masses in the anterior mediastinum.


Asunto(s)
Linfoma , Neoplasias del Mediastino , Neoplasias del Timo , Femenino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias del Timo/patología , Linfoma/diagnóstico por imagen , Neoplasias del Mediastino/diagnóstico por imagen
3.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37409393

RESUMEN

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Neoplasias , Humanos , Neoplasias/sangre , Neoplasias/complicaciones , Neoplasias/diagnóstico , Valor Predictivo de las Pruebas , Factores de Riesgo , Tromboembolia Venosa/sangre , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevención & control , Bioensayo/normas , Sensibilidad y Especificidad
4.
Radiol Oncol ; 57(2): 158-167, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37341197

RESUMEN

BACKGROUND: While computed tomography (CT)-guided liver biopsies are commonly performed using unenhanced images, contrast-enhanced images are beneficial for challenging puncture pathways and lesion locations. This study aimed to evaluate the accuracy of CT-guided biopsies for intrahepatic lesions using unenhanced, intravenous (IV)-enhanced, or intra-arterial Lipiodol-marked CT for lesion marking. PATIENTS AND METHODS: Six-hundred-seven patients (men: 358 [59.0%], mean age 61 years; SD ±12.04) with suspect hepatic lesions and CT-guided liver biopsies were retrospectively evaluated. Successful biopsies were histopathological findings other than typical liver tissue or non-specific findings. Data was ascertained regarding the use of contrast medium for the biopsy-planning CT, unenhanced (group 1) vs. Lipiodol (group 2) vs. IV contrast (group 3). Technical success and influencing factors were insulated. Complications were noted. The results were analyzed using the Wilcoxon-Man-Whitney t-test, Chi-square test, and Spearman-Rho. RESULTS: Overall lesion hitting rate was 73.1%, with significantly better rates using Lipiodol-marked lesions (79.3%) compared to group 1 (73.8%) and group 3 (65.2%) (p = 0.037). Smaller lesions (<20 mm diameter) benefited significantly from Lipiodol-marking with 71.2% successful biopsy rate compared to group 1 (65.5%) and group 3 (47.7%) (p = 0.021). Liver cirrhosis (p = 0.94) and entity of parenchymal lesions (p = 0.78) had no impact on the hitting rate between the groups. No major complications occurred during the interventions. CONCLUSIONS: Pre-biopsy Lipiodol marking of suspect hepatic lesions significantly increases the lesion-hitting rate and is especially beneficial for biopsy of smaller targets below 20 mm diameter. Further, Lipiodol marking is superior to IV contrast for non-visible lesions in unenhanced CT. Target lesion entity has no impact on the hitting rate.


Asunto(s)
Aceite Etiodizado , Biopsia Guiada por Imagen , Masculino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X
5.
Acad Radiol ; 30(12): 3010-3021, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37105804

RESUMEN

RATIONALE AND OBJECTIVES: To investigate the diagnostic value of radiomics features and dual-source dual-energy CT (DECT) based material decomposition in differentiating low-risk thymomas, high-risk thymomas, and thymic carcinomas. MATERIALS AND METHODS: This retrospective study included 32 patients (16 males, mean age 66 ± 14 years) with pathologically confirmed thymic masses who underwent contrast-enhanced DECT between 10/2014 and 01/2023. Two experienced readers evaluated all patients regarding conventional radiomics features, as well as DECT-based features, including attenuation (HU), iodine density (mg/mL), and fat fraction (%). Data comparisons were performed using analysis of variance and chi-square statistic tests. Receiver operating characteristic curve analysis and Cox-regression tests were used to discriminate between low-risk/high-risk thymomas and thymic carcinomas. RESULTS: Of the 32 thymic tumors, 12 (38%) were low-risk thymomas, 11 (34%) were high-risk thymomas, and 9 (28%) were thymic carcinomas. Values differed significantly between low-risk thymoma, high-risk thymoma, and thymic carcinoma regarding DECT-based features (p ≤ 0.023) and 30 radiomics features (p ≤ 0.037). The area under the curve to differentiate between low-risk/high-risk thymomas and thymic cancer was 0.998 (95% CI, 0.915-1.000; p < 0.001) for the combination of DECT imaging parameters and radiomics features, yielding a sensitivity of 100% and specificity of 96%. During a follow-up of 60 months (IQR, 35-60 months), the multiparametric approach including radiomics features, DECT parameters, and clinical parameters showed an excellent prognostic power to predict all-cause mortality (c-index = 0.978 [95% CI, 0.958-0.998], p = 0.003). CONCLUSION: A multiparametric approach including conventional radiomics features and DECT-based features facilitates accurate, non-invasive discrimination between low-risk/high-risk thymomas and thymic carcinomas.


Asunto(s)
Yodo , Timoma , Neoplasias del Timo , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Timoma/diagnóstico , Timoma/patología , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias del Timo/patología , Pronóstico
6.
Cancer Imaging ; 23(1): 38, 2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37072856

RESUMEN

BACKGROUND: The advent of next-generation computed tomography (CT)- and magnetic resonance imaging (MRI) opened many new perspectives in the evaluation of tumor characteristics. An increasing body of evidence suggests the incorporation of quantitative imaging biomarkers into clinical decision-making to provide mineable tissue information. The present study sought to evaluate the diagnostic and predictive value of a multiparametric approach involving radiomics texture analysis, dual-energy CT-derived iodine concentration (DECT-IC), and diffusion-weighted MRI (DWI) in participants with histologically proven pancreatic cancer. METHODS: In this study, a total of 143 participants (63 years ± 13, 48 females) who underwent third-generation dual-source DECT and DWI between November 2014 and October 2022 were included. Among these, 83 received a final diagnosis of pancreatic cancer, 20 had pancreatitis, and 40 had no evidence of pancreatic pathologies. Data comparisons were performed using chi-square statistic tests, one-way ANOVA, or two-tailed Student's t-test. For the assessment of the association of texture features with overall survival, receiver operating characteristics analysis and Cox regression tests were used. RESULTS: Malignant pancreatic tissue differed significantly from normal or inflamed tissue regarding radiomics features (overall P < .001, respectively) and iodine uptake (overall P < .001, respectively). The performance for the distinction of malignant from normal or inflamed pancreatic tissue ranged between an AUC of ≥ 0.995 (95% CI, 0.955-1.0; P < .001) for radiomics features, ≥ 0.852 (95% CI, 0.767-0.914; P < .001) for DECT-IC, and ≥ 0.690 (95% CI, 0.587-0.780; P = .01) for DWI, respectively. During a follow-up of 14 ± 12 months (range, 10-44 months), the multiparametric approach showed a moderate prognostic power to predict all-cause mortality (c-index = 0.778 [95% CI, 0.697-0.864], P = .01). CONCLUSIONS: Our reported multiparametric approach allowed for accurate discrimination of pancreatic cancer and revealed great potential to provide independent prognostic information on all-cause mortality.


Asunto(s)
Yodo , Neoplasias Pancreáticas , Femenino , Humanos , Imagen por Resonancia Magnética , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Estudios Retrospectivos
7.
Sci Rep ; 13(1): 533, 2023 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-36631548

RESUMEN

We aimed to identify hepatocellular carcinoma (HCC) patients who will respond to repetitive transarterial chemoembolization (TACE) to improve the treatment algorithm. Retrospectively, 61 patients (mean age, 65.3 years ± 10.0 [SD]; 49 men) with 94 HCC mRECIST target-lesions who had three consecutive TACE between 01/2012 and 01/2020 were included. Robust and non-redundant radiomics features were extracted from the 24 h post-embolization CT. Five different clinical TACE-scores were assessed. Seven different feature selection methods and machine learning models were used. Radiomics, clinical and combined models were built to predict response to TACE on a lesion-wise and patient-wise level as well as its impact on overall-survival prognostication. 29 target-lesions of 19 patients were evaluated in the test set. Response rates were 37.9% (11/29) on the lesion-level and 42.1% (8/19) on the patient-level. Radiomics top lesion-wise response prognostications was AUC 0.55-0.67. Clinical scores revealed top AUCs of 0.65-0.69. The best working model combined the radiomic feature LargeDependenceHighGrayLevelEmphasis and the clinical score mHAP_II_score_group with AUC = 0.70, accuracy = 0.72. We transferred this model on a patient-level to achieve AUC = 0.62, CI = 0.41-0.83. The two radiomics-clinical features revealed overall-survival prognostication of C-index = 0.67. In conclusion, a random forest model using the radiomic feature LargeDependenceHighGrayLevelEmphasis and the clinical mHAP-II-score-group seems promising for TACE response prognostication.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Masculino , Humanos , Anciano , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/tratamiento farmacológico , Estudios Retrospectivos , Quimioembolización Terapéutica/métodos , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
8.
NMR Biomed ; 36(2): e4828, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36082477

RESUMEN

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Imagen de Cuerpo Entero , Flujo de Trabajo
9.
Acad Radiol ; 29(6): 861-870, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35346565

RESUMEN

PURPOSE: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System). METHODS: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score. RESULTS: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis. CONCLUSIONS: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.


Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Calcificación Vascular , Calcio , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Pulmón , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , SARS-CoV-2 , Calcificación Vascular/diagnóstico por imagen
10.
Radiologe ; 62(3): 239-246, 2022 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-35037980

RESUMEN

CLINICAL/METHODICAL ISSUE: The diagnosis of hepatocellular carcinoma (HCC)-especially the characterization of small lesions <2 cm-continues to be a radiological challenge. STANDARD RADIOLOGICAL METHODS: In the current S3 guideline on diagnosis and therapy of HCC, contrast-enhanced imaging examinations, such as contrast-enhanced ultrasonography (CEUS), computed tomography (CT), and magnetic resonance imaging (MRI), are still the diagnostic standard. METHODOLOGICAL INNOVATIONS: HCC in the cirrhotic liver should be diagnosed by its typical contrast-enhanced pattern in the MRI. In addition, the use of quality assurance instruments such as LI-RADS (Liver Imaging Reporting and Data System) contributes to the desired consistency of findings, even with small ambiguous findings. PERFORMANCE: Many studies have shown that the LI-RADS classification reflects the likelihood of HCC and other malignant liver lesions. ACHIEVEMENTS: Guidelines and quality assurance instruments contribute to a more precise diagnosis in patients with suspected HCC. PRACTICAL RECOMMENDATIONS: A guideline-compliant diagnostic algorithm and the LI-RADS should be used across the board for accurate HCC diagnostics.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía/métodos
11.
Acad Radiol ; 29(6): 880-887, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34266738

RESUMEN

PURPOSE: To assess the influence of intravenously injected contrast agent on bone mineral density (BMD) assessment in dual-source dual-energy CT. METHODS: This retrospective study included 1,031 patients (mean age, 53 ± 7 years; 519 women) who had undergone third-generation dual-source dual-energy CT in context of tumor staging between January 2019 and December 2019. Dedicated postprocessing software based on material decomposition was used for phantomless volumetric BMD assessment of trabecular bone of the lumbar spine. Volumetric trabecular BMD values derived from unenhanced and contrast-enhanced portal venous phase were compared by calculating correlation and agreement analyses using Pearson product-moment correlation, linear regression, and Bland-Altman plots. RESULTS: Mean BMD values were 115.53 ± 37.23 and 116.10 ± 37.78 mg/cm3 in unenhanced and contrast-enhanced dual-energy CT series, respectively. Values from contrast-enhanced portal venous phase differed not significantly from those of the unenhanced phase (p = 0.44) and showed high correlation (r = 0.971 [95% CI, 0.969-0.973]) with excellent agreement in Bland-Altman plots. Mean difference of the two phases was 0.61 mg/cm3 (95% limits of agreement, -17.14 and 18.36 mg/cm3). CONCLUSION: Portal venous phase dual-source dual-energy CT allows for accurate opportunistic BMD assessment of trabecular bone of the lumbar spine compared to unenhanced imaging. Therefore, dual-source CT may provide greater flexibility regarding BMD assessment in clinical routine and reduce radiation exposure by avoiding additional osteodensitometry examinations, as contrast-enhanced CT scans in context of tumor staging are increasingly performed in dual-energy mode.


Asunto(s)
Densidad Ósea , Medios de Contraste , Absorciometría de Fotón/métodos , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
12.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34820684

RESUMEN

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Asunto(s)
Desplazamiento del Disco Intervertebral , Imagen Radiográfica por Emisión de Doble Fotón , Médula Ósea , Edema , Femenino , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
13.
Eur Radiol Exp ; 5(1): 43, 2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-34608576

RESUMEN

BACKGROUND: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). METHODS: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. RESULTS: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984-0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. CONCLUSIONS: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.


Asunto(s)
Densidad Ósea , Tomografía Computarizada por Rayos X , Absorciometría de Fotón , Vértebras Lumbares/diagnóstico por imagen , Fantasmas de Imagen
14.
Artículo en Inglés | MEDLINE | ID: mdl-33481646

RESUMEN

Background: To evaluate the predictive value of Lipiodol for response evaluation of hepatocellular carcinoma (HCC) treated with conventional transarterial chemoembolization (cTACE) by analysis of the enhancement pattern during angiography and in postinterventional computed tomography (CT). Materials and Methods: This retrospective study included 30 patients (mean age 63 years, range: 36 to 82 years, 22 males) with HCC. Patients received three Lipiodol-based cTACE sessions, each followed by an unenhanced CT within 24-h. Contrast-enhanced magnetic resonance imaging (MRI) was acquired before and after the treatment to determine tumor response. Lipiodol enhancement pattern, tumor vascularization, and density were evaluated by angiography and CT. Initial tumor size and response to cTACE were analyzed by MRI according to modified response evaluation criteria in solid tumors (mRECIST) in a 4-week follow-up. Results: Analysis of HCC lesions (68 lesions in 30 patients) during cTACE revealed clear visibility and hypervascularization in angiography as a potential independent parameter able to predict tumor response. A significant correlation was found for response measurements by volume (p = 0.012), diameter (p = 0.006), and according to mRECIST (p = 0.039). The amount of Lipiodol and enhancement pattern in postinterventional CT did not correlate with therapy response. Measurements of Hounsfield unit values after cTACE do not allow sufficient prediction of the tumor response. Conclusion: Hypervascularized HCC lesions with clear visibility after Lipiodol administration in the angiography respond significantly better to cTACE compared to hypo- or nonvascularized lesions.

15.
Eur Radiol ; 31(4): 2242-2251, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32960329

RESUMEN

OBJECTIVES: To prospectively evaluate the therapy response of third-line TACE with DSM or lipiodol in the treatment of CRLM using MRI. METHODS: In this prospective, randomized, single-center trial, patients were randomly assigned to receive TACE therapy with either lipiodol or DSM as the embolization agent. Therapy response was evaluated using MRI. Local tumor response was determined according to RECIST 1.1, and survival data was analyzed using the Kaplan-Meier estimator. RESULTS: Fifty patients (35 male, 15 female) were randomized and included in the survival analysis, whereas 31 patients completed therapy and were considered for evaluation of tumor responses (cTACE: n = 13, DSM-TACE: n = 18). In the cTACE group, PR was observed in 23%, SD in 15%, and PD in 62%. In the DSM-TACE-group, PR was observed in 22% of patients, SD in 56%, and PD in 22% (p = 0.047). In addition, the DSM-TACE group showed statistically significant tumor volume reduction (p = 0.006). Median apparent diffusion coefficient values were not significantly different between both groups at baseline (p = 0.26) and study endpoint (p = 0.83). Median survival in the cTACE group was 13 months (95% confidence interval, range 5-40 months) compared to 16 months (95% confidence interval, range 1-48 months) in the DSM-TACE group, exhibiting no statistically significant difference (p = 0.75). CONCLUSION: DSM-TACE showed a significant difference reducing tumor volume and in tumor response according to RECIST 1.1 compared to cTACE. Thus, patients with CRLM might not only benefit from short embolization effect of DSM-TACE but also from better tumor responses. Apparent diffusion coefficients were not significantly different between both groups and cannot be used as a biomarker for monitoring for therapeutic effect of TACE. KEY POINTS: • To our knowledge, this is the first prospective study that directly compared cTACE and DSM-TACE in patients with CRLM. • DSM-TACE showed a significant difference reducing tumor volume (p = 0.006) and in tumor response according to RECIST 1.1 (p = 0.047) compared to cTACE. • Survival analysis showed a median survival of 13 months in the cTACE group compared to 16 months in the DSM-TACE group (p = 0.75).


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Colorrectales , Neoplasias Hepáticas , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/terapia , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Masculino , Microesferas , Estudios Prospectivos , Resultado del Tratamiento
16.
Eur Radiol ; 30(12): 6757-6769, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32676784

RESUMEN

OBJECTIVES: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). METHODS: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. RESULTS: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. CONCLUSIONS: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance. KEY POINTS: • Quantitative imaging features differ between normal and malignant tissue of the peripheral zone in prostate cancer. • Radiomic feature analysis of clinical routine multiparametric MRI has the potential to improve the stratification of clinically significant versus insignificant prostate cancer lesions in the peripheral zone. • Certain combinations of standard multiparametric MRI reporting and assessment categories with feature subsets and machine learning algorithms reduced the diagnostic performance over standard clinical assessment categories alone.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Aprendizaje Automático , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Área Bajo la Curva , Biopsia , Análisis por Conglomerados , Humanos , Masculino , Persona de Mediana Edad , Análisis de Componente Principal , Próstata/diagnóstico por imagen , Prostatectomía , Reproducibilidad de los Resultados , Estudios Retrospectivos , Máquina de Vectores de Soporte , Resultado del Tratamiento
17.
J Vasc Interv Radiol ; 31(2): 301-310, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31899107

RESUMEN

PURPOSE: To examine predictive value of apparent diffusion coefficient (ADC) in diffusion-weighted imaging (DWI) for response of patients with primary and secondary lung neoplasms undergoing transpulmonary chemoembolization (TPCE) and transarterial chemoperfusion (TACP) treatment. MATERIALS AND METHODS: Thirty-one patients (mean age ± SD 64 ± 12.4 y) with 42 lung target lesions (13 primary and 29 secondary) underwent DWI and subsequent ADC analysis on a 1.5T MR imaging scanner before and 30.3 days ± 6.4 after first session of TPCE or TACP. After 3.1 treatment sessions ± 1.4 performed in 2- to 4-week intervals, morphologic response was analyzed by comparing tumor diameter and volume before and after treatment on unenhanced T1-weighted MR images. On a per-lesion basis, response was classified according to Response Evaluation Criteria In Solid Tumors. RESULTS: Threshold ADC increase of 20.7% indicated volume response with 88% sensitivity and 78% specificity (area under the curve [AUC] = 0.84). Differences between ADC changes in volume response groups were significant (P = .002). AUC for volume response predicted by ADC before treatment was 0.77. Median ADC before treatment and mean ADC change were 1.09 × 10-3 mm2/second and 0.36 × 10-3 mm2/second ± 0.23, 1.45 × 10-3 mm2/second and 0.14 × 10-3 mm2/second ± 0.16, and 1.30 × 10-3 mm2/second and 0.06 × 10-3 mm2/second ± 0.19 in partial response, stable disease, and progressive disease groups. In primary lung cancer lesions, strong negative correlation of ADC change with change in diameter (ρ = -.87, P < .001) and volume (ρ = -.66, P = .016) was found. In metastases, respective correlation coefficients were ρ = -.18 (P = .356) and ρ = -.35 (P = .061). CONCLUSIONS: ADC quantification shows considerable diagnostic value for predicting response and monitoring TPCE and TACP treatment of patients with primary and secondary lung neoplasms.


Asunto(s)
Quimioembolización Terapéutica , Quimioterapia del Cáncer por Perfusión Regional , Imagen de Difusión por Resonancia Magnética , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Femenino , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/secundario , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
18.
Acad Radiol ; 27(7): e168-e175, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31727567

RESUMEN

RATIONALE AND OBJECTIVES: To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM). MATERIALS AND METHODS: We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC). RESULTS: Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001). CONCLUSION: Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Imagen Radiográfica por Emisión de Doble Fotón , Anciano , Neoplasias Colorrectales/diagnóstico por imagen , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X
19.
Eur Radiol ; 29(12): 6539-6549, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31236701

RESUMEN

OBJECTIVES: To evaluate the diagnostic value of Lipiodol distribution in angiography and CT to differentiate between hepatocellular carcinoma (HCC) and benign nodules of LI-RADS 3 and 4 lesions observed in MRI of liver cirrhosis. METHODS: This retrospective study included all patients with liver cirrhosis who had diagnosis of LI-RADS 3 or 4 lesions by MRI who underwent a Lipiodol-based angiography and post-interventional unenhanced CT- and liver biopsy. Two independent radiologists evaluated appearance, contrast enhancement, Lipiodol uptake in angiography, and morphological parameters (size, form, and density) of the lesions in unenhanced post-angiography CT. α-Fetoprotein (AFP) levels and pre-existing liver conditions were additionally taken into consideration. Differences between HCC lesions and benign nodules were analyzed. Sensitivity and specificity were calculated. P < 0.05 was considered as statistically significant. RESULTS: Of 60 patients (men, n = 42 [70.0%]; women, 18 [30.0%]; mean age, 61 ± 9.1 years) 36 (60.0%) had HCC and 24 (40.0%) benign nodules. Clear visibility in angiography (sensitivity [se], 100%; specificity [sp], 87.5%) with homogeneous or lacunar Lipiodol enhancement (se, 86.1%; sp, 100%) in consecutive CT can be diagnosed as HCC lesions in cirrhotic liver. Lesion form (p < 0.001), round or oval, and intense contrast (p < 0.001) are minor features which can facilitate the findings. Furthermore, patients with HCC showed a larger lesion size in CT (p = 0.026). CONCLUSION: Clearly detectable lesions in Lipiodol-based angiography and a homogeneous or lacunar enhancement in post-angiographic non-contrast CT allow for differentiation of intrahepatic lesions classified as LI-RADS 3 or 4 into benign vs. malign liver lesions with high sensitivity and specificity in patients with liver cirrhosis. Definite diagnosis may not require an additional biopsy. KEY POINTS: • Combination of clear visibility in Lipiodol-based angiography and homogeneous or lacunar enhancement in following native CT scan is HCC-defining. • In lesions classified with MRI as LI-RADS 3 or 4, evaluation based on Lipiodol angiography and following plain CT performed is highly sensitive and specific for the differentiation between HCC and benign nodules in a cirrhotic liver. • The results lead to an alternative pathway in the diagnosis of HCC in cirrhotic liver without the need of an additional liver biopsy.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste/farmacocinética , Aceite Etiodizado/farmacocinética , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Angiografía/métodos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/patología , Femenino , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/patología , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
20.
AJR Am J Roentgenol ; 212(4): 741-747, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30699006

RESUMEN

OBJECTIVE: The purpose of this study was to compare radiation dose and image quality of single- and dual-energy CT (SECT, DECT) examinations of the chest in matched cohorts for second and third-generation dual-source CT (DSCT) systems. MATERIALS AND METHODS: We analyzed 200 patients (100 men; mean age, 61.7 ± 14.8 years old; 100 women, mean age, 59.4 ± 15.1 years old), matched by sex and body mass index, who had undergone clinically indicated contrast-enhanced chest CT. Four study groups, each consisting of 50 patients, were evaluated. Contrast-enhanced chest CT was performed using vendor-preset second-generation DSCT (group A, 120-kV SECT; group C, 80/Sn140-kV DECT) or third-generation DSCT (group B, 90-kV SECT; group D, 90/Sn150-kV DECT) protocols. Radiation dose assessment was normalized to a scan range of 27.5 cm. Image quality was objectively analyzed using dose-independent figure-of-merit (FOM) contrast-to-noise ratio (CNR) calculations and subjectively evaluated by three independent radiologists. RESULTS: Direct comparison of effective radiation dose for second-generation DSCT groups A and C showed statistically significant lower radiation dose values for DECT compared with SECT acquisition (3.2 ± 1.2 mSv vs 2.3 ± 0.6 mSv, p ≤ 0.004), but differences between third-generation SECT and DECT were not significant (1.2 ± 0.9 mSv vs 1.3 ± 0.6 mSv, p = 0.412). FOM CNR analysis revealed highest values for third-generation DECT (p ≤ 0.043). Differences in subjective image quality between the four groups were not statistically significant (p ≥ 0.179). CONCLUSION: Contrast-enhanced DECT examinations of the chest can be performed routinely with second- and third-generation DSCT systems without either increased radiation exposure or decreased image quality compared with SECT acquisition.


Asunto(s)
Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...