Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Quant Imaging Med Surg ; 14(4): 2946-2954, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38617152

RESUMEN

Background: Despite the common use of ultrasound (US)-guided fine-needle aspiration (FNA) for axillary node (AN) in breast cancer patients, only a limited number of studies are available regarding the diagnostic performance of AN-FNA according to the suspicion level based on US findings. This study compares the outcomes of US-guided AN-FNA in breast cancer patients, differentiating between those undergoing staging and surveillance. Methods: A cross-sectional retrospective study with retrospective analysis was conducted on 767 consecutive AN-FNA procedures performed in 2017 at Samsung Medical Center in Seoul, with 654 for staging and 113 for surveillance in breast cancer patients. The radiologists performed axillary US and the specific finding was prospectively classified into the AN-reporting and data system (AN-RADS) category 3-5 before FNA. The malignancy rate of each category was evaluated. The chi-square test, with or without Bonferroni correction, or Fisher's exact test was used to compare the malignancy rates between the staging and surveillance groups for each category. Results: Among the 767 AN-FNAs, 424 (55.3%) were malignant. The malignancy rate was significantly higher in the staging group (59.5%) than in the surveillance group (31.0%, P<0.0001). The distribution of AN-RADS categories differed between the groups (P=0.015), with 4A being the most common. The malignancy rates in categories 3, 4A, 4B, 4C, and 5 were as follows: 5.6%, 36.0%, 77.4%, 87.7%, and 98.4% in the staging group, and 0.0%, 9.7%, 53.3%, 88.9%, and 100% in the surveillance group. The malignancy rate was significantly different between the two groups only in category 4A (P=0.0001). Conclusions: AN-FNA according to AN-RADS category appears to be an appropriate method for determination of axillary nodal status. Overall malignancy rate of AN-FNA in breast cancer patients was higher in the staging group than in the surveillance group. According to the suspicion level, the difference between two groups was significant only in category 4A.

2.
Diagnostics (Basel) ; 13(17)2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37685338

RESUMEN

Rationale and Objective: To evaluate the characteristic clinical and imaging findings of charcoal granuloma and suggest features that may differentiate charcoal granuloma from breast cancer. Materials and Methods: This retrospective study included 18 patients with a histologically confirmed breast charcoal granuloma between 2005 and 2021 at a single institution. All patients had a history of breast surgery after ultrasound (US)-guided charcoal marking. Two radiologists analyzed the radiologic findings of charcoal granulomas, including the presence of a mass or calcification; the shape, margin and density of the masses on mammography; and the location, size, shape, margin, orientation, echogenicity, vascularity, presence of an echogenic halo, and posterior acoustic shadowing on US. In cases with available follow-up images, we also investigated whether the size and shape had changed. Results: The median interval between breast surgery and the diagnosis of charcoal granuloma was 2.3 years (range, 0.7-18.3 years). Thirteen lesions (72.2%) were detected on screening images. In 11 (61.1%) cases, the surgical incision was not made in the tattooed skin area. Mammography showed positive findings in 10/15 patients, and most lesions were isodense masses (70%). There were no cases with calcification. On US, all lesions were masses and showed a taller-than-wide orientation (61.1%), round or oval shape (55.6%), and iso- or hyperechogenicity (83.3%). Echogenic halo (27.8%) and posterior acoustic shadowing (16.7%) were uncommon. On Doppler US, only four cases (22.2%) showed increased vascularity. Most were classified as BI-RADS 3 (38.9%) or 4A (50.0%). After biopsy, 12 patients had follow-up mammography and US. The size of the lesion decreased in nine cases and remained unchanged in three cases. A decrease in the lesion size after biopsy showed a negative correlation with the interval between detection on imaging and biopsy (p = 0.04). Conclusion: Charcoal granuloma is most commonly found 2-3 years after surgery and occurs more frequently when the incision site is different from the tattooed skin area. US findings of tall and round or oval masses with iso- or hyperechogenicity without increased vascularity could help to differentiate them from malignancies.

3.
Yonsei Med J ; 64(10): 633-640, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37727923

RESUMEN

PURPOSE: To compare the prognosis of patients with axillary adenocarcinoma from an unknown primary (ACUPax) origin with negative MRI results and those with MRI-detected primary breast cancers. MATERIALS AND METHODS: The breast MRI images of 32 patients with ACUPax without signs of primary breast cancer on mammography and ultrasound (US) were analyzed. Spot compression-magnification mammography and second-look US were performed for the area of MRI abnormality in patients with positive results; any positive findings corresponding to the MRI abnormality were confirmed by biopsy. If suspicious MRI lesions could not be localized on mammography or US, MR-guided biopsy or excision biopsy after MR-guided localization was performed. We compared the prognosis of patients with negative breast MRI with that for patients with MRI-detected primary breast cancers. RESULTS: Primary breast cancers were confirmed in 8 (25%) patients after breast MRI. Primary breast cancers were not detected on MRI in 24 (75%) patients, including five cases of false-positive MRI results. Twenty-three patients underwent axillary lymph node dissection (ALND) followed by whole breast radiation therapy (WBRT) and chemotherapy (n=17) or subsequent chemotherapy only (n=2). Recurrence or distant metastasis did not occur during follow up in 7/8 patients with MRI-detected primary breast cancers and 22/24 patients with negative MRI results. Regional recurrence or distant metastasis did not occur in any MR-negative patient who received adjuvant chemotherapy after ALND and WBRT. CONCLUSION: The prognoses of MR-negative patients with ACUPax who received ALND and WBRT followed by chemotherapy were as good as those of patients with MRI-detected primary breast cancers.


Asunto(s)
Adenocarcinoma , Neoplasias Primarias Desconocidas , Humanos , Metástasis Linfática/diagnóstico por imagen , Neoplasias Primarias Desconocidas/diagnóstico por imagen , Radiografía , Imagen por Resonancia Magnética , Pronóstico
4.
Eur Radiol ; 33(10): 7186-7198, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37188881

RESUMEN

OBJECTIVE: To investigate whether artificial intelligence-based computer-aided diagnosis (AI-CAD) can improve radiologists' performance when used to support radiologists' interpretation of digital mammography (DM) in breast cancer screening. METHODS: A retrospective database search identified 3158 asymptomatic Korean women who consecutively underwent screening DM between January and December 2019 without AI-CAD support, and screening DM between February and July 2020 with image interpretation aided by AI-CAD in a tertiary referral hospital using single reading. Propensity score matching was used to match the DM with AI-CAD group in a 1:1 ratio with the DM without AI-CAD group according to age, breast density, experience level of the interpreting radiologist, and screening round. Performance measures were compared with the McNemar test and generalized estimating equations. RESULTS: A total of 1579 women who underwent DM with AI-CAD were matched with 1579 women who underwent DM without AI-CAD. Radiologists showed higher specificity (96% [1500 of 1563] vs 91.6% [1430 of 1561]; p < 0.001) and lower abnormal interpretation rates (AIR) (4.9% [77 of 1579] vs 9.2% [145 of 1579]; p < 0.001) with AI-CAD than without. There was no significant difference in the cancer detection rate (CDR) (AI-CAD vs no AI-CAD, 8.9 vs 8.9 per 1000 examinations; p = 0.999), sensitivity (87.5% vs 77.8%; p = 0.999), and positive predictive value for biopsy (PPV3) (35.0% vs 35.0%; p = 0.999) according to AI-CAD support. CONCLUSIONS: AI-CAD increases the specificity for radiologists without decreasing sensitivity as a supportive tool in the single reading of DM for breast cancer screening. CLINICAL RELEVANCE STATEMENT: This study shows that AI-CAD could improve the specificity of radiologists' DM interpretation in the single reading system without decreasing sensitivity, suggesting that it can benefit patients by reducing false positive and recall rates. KEY POINTS: • In this retrospective-matched cohort study (DM without AI-CAD vs DM with AI-CAD), radiologists showed higher specificity and lower AIR when AI-CAD was used to support decision-making in DM screening. • CDR, sensitivity, and PPV for biopsy did not differ with and without AI-CAD support.


Asunto(s)
Inteligencia Artificial , Neoplasias de la Mama , Humanos , Femenino , Estudios de Cohortes , Estudios Retrospectivos , Mamografía/métodos , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Computadores , Tamizaje Masivo/métodos
6.
J Korean Soc Radiol ; 84(2): 398-408, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37051396

RESUMEN

Purpose: This study aimed to evaluate the radiological and clinical characteristics of benign adenomyoepitheliomas of the breast. Materials and Methods: Over the last 20 years, 120 patients were histologically diagnosed with breast adenomyoepithelioma (AME) at our institution. We excluded 43 patients who were incidentally diagnosed during mastectomy for breast cancer, 28 who underwent percutaneous biopsy without further excision, and 8 who had biopsy-confirmed benign AME and were found to have another pathology after complete excision. We retrospectively reviewed the clinical records and radiological findings of the remaining 41 patients with histologically diagnosed benign breast AMEs after complete excision. Results: All 41 patients underwent US; 38 underwent mammography (MG) and US; and 18 underwent MG, US, and MRI. MG detected 38 cases with a round or oval shape (56%), and mass (89%), were non-circumscribed (62%), hyperdense (53%), and without microcalcifications (95%). Breast US revealed suspicious masses (98%) with a non-circumscribed margin (66%), hypoechogenicity (43%), and intratumoral vascularity (63%). All lesions on breast MRI showed suspicious masses (100%) with ill-defined margins (61%), and 84% showed wash-out kinetics. Benign AMEs showed suspicious features of Breast Imaging Reporting and Data System (BI-RADS) category 4 or 5 in 83%-95% of the MG, US, and MRI. Sixteen of the 41 cases were misdiagnosed on the initial core needle biopsy and two were diagnosed as malignancy. Conclusion: Benign breast AME often shows suspicious radiological features mimicking a malignant mass on MG, US, and MRI. Differentiating benign AME from other pathologies might be difficult on core needle biopsy, and complete excision is needed for a correct diagnosis.

7.
Radiology ; 307(4): e222435, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37097135

RESUMEN

Background Automated breast (AB) US effectively depicts mammographically occult breast cancers in Western women. However, few studies have focused on the outcome of supplemental AB US in Asian women who have denser breasts than Western women. Purpose To evaluate the performance of supplemental AB US on mammography-based breast cancer screening in Asian women with dense breasts and those with nondense breasts. Materials and Methods A retrospective database search identified asymptomatic Korean women who underwent digital mammography (DM) and supplemental AB US screening for breast cancer between January 2018 and December 2019. We excluded women without sufficient follow-up, established final diagnosis, or histopathologic results. Performance measures of DM alone and AB US combined with DM (hereafter AB US plus DM) were compared. The primary outcome was cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed based on mammography density. Results From 2785 screening examinations in 2301 women (mean age, 52 years ± 9 [SD]), 28 cancers were diagnosed (26 screening-detected cancers, two interval cancers). When compared with DM alone, AB US plus DM resulted in a higher CDR of 9.3 per 1000 examinations (95% CI: 7.7, 10.3) versus 6.5 per 1000 examinations (95% CI: 5.2, 7.2; P < .001) and a higher sensitivity of 90.9% (95% CI: 77.3, 100.0) versus 63.6% (95% CI: 40.9, 81.8; P < .001) but a lower specificity of 86.8% (95% CI: 85.2, 88.2) versus 94.6% (95% CI: 93.6, 95.5; P < .001) in women with dense breasts. In women with nondense breasts, AB US plus DM resulted in a higher CDR of 9.5 per 1000 examinations (95% CI: 7.1, 10.6) versus 6.3 per 1000 examinations (95% CI: 3.5, 7.1; P < .001), whereas specificity was lower at 95.2% (95% CI: 93.4, 96.8) versus 97.1% (95% CI: 95.8, 98.4; P < .001). Conclusion In Asian women, the addition of automated breast US to digital mammography showed higher cancer detection rates but lower specificities in both dense and nondense breasts. © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama , Mama , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Mamografía/métodos , Densidad de la Mama , Tamizaje Masivo/métodos , Detección Precoz del Cáncer/métodos
8.
Acad Radiol ; 30(12): 2931-2939, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37045651

RESUMEN

RATIONALE AND OBJECTIVES: This study aimed to describe new lesions called ring enhancement in non-neoplastic breast tissue on breast magnetic resonance imaging (MRI) after neoadjuvant chemotherapy (NAC) in breast cancer patients, and to investigate the factors influencing their occurrence. MATERIALS AND METHODS: We retrospectively reviewed 811 consecutive patients (mean age; 50.0 [range, 24-81] years) with breast cancer who had undergone NAC between January 2020 and December 2021, identifying cases with new ring enhancement on post-NAC MRI. We analyzed the MRI findings and identified factors that were potentially associated with ring enhancement through statistical analyses using the chi-square test, univariate and multivariate logistic regression analysis. RESULTS: Forty-seven (5.8%) patients developed new ring enhancement on post-NAC MRI. The variables associated with ring enhancement were premenopausal status (p = 0.0007), younger age (p = 0.0011), high mammographic density (p = 0.0076), and high background parenchymal enhancement (BPE) on baseline MRI (p = 0.0001). Among these, high BPE was independently associated with the occurrence of ring enhancement (p = 0.0294, OR = 2.08; CI: 1.08-4.03). In a subset of high BPE patients, an association between HER2-positive cancers and ring enhancement was observed (odds ratio = 5.51 vs. 2.54). New lesion development exhibited no association with any specific NAC drug (p = 0.1676-0.7583 per drug). CONCLUSION: Ring enhancement often occurs on post-NAC MRI and mostly disappears on subsequent MRI scans. High BPE on MRI was associated with this finding and HER2-positive cancers potentiated it. Knowledge of this finding can prevent unnecessary biopsies.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/patología , Estudios Retrospectivos , Terapia Neoadyuvante/métodos , Incidencia , Quimioterapia Adyuvante , Mama/diagnóstico por imagen , Mama/patología , Imagen por Resonancia Magnética/métodos
9.
J Breast Cancer ; 26(1): 77-85, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36852967

RESUMEN

We present our initial experience of ultrasound (US)-guided localization of clipped metastatic axillary lymph nodes (LNs) following neoadjuvant chemotherapy (NAC). We evaluated US visibility and the successful excision rate of clipped LN after NAC in 29 consecutive patients with breast cancer. US-guided localization of clipped nodes was performed in 22 patients on the day of surgery, while seven patients underwent surgery without localization. The clips were identified in all patients with residual metastatic LNs and 6 of 12 (50%) patients without residual metastatic LNs on US. Six patients without visible clips underwent US-guided localization at the presumed previous clip insertion site. The successful excision rate of 22 LNs with localization was 100% (even though 3 of them were non-sentinel LNs) and 57% (4/7) without localization. Regardless of the presence of visible residual metastatic LNs on US after NAC, successful excision of the clipped LN with US-guided localization is feasible.

10.
Sci Rep ; 13(1): 1811, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36725965

RESUMEN

In this study, we aimed to evaluate the benefits and losses of mammography with and without implant displacement (ID) and propose an appropriate imaging protocol for the screening of breasts with implants. We evaluated mammograms of 162 breasts in 96 patients including 71 breasts with biopsy-proven cancers. Mammography of each breast included standard MLO and ID MLO images. We reviewed the mammograms using clinical image quality criteria, which consist of parameters that evaluate the proper positioning of the breast and the image resolution. Standard MLO images showed significantly higher scores for proper positioning but showed significantly lower scores for image resolution than the ID MLO images. Moreover, standard MLO images showed significantly higher kVp, mAs, and compressed breast thickness than the ID MLO images. The organ dose was also higher in the standard MLO images than in the ID MLO images, but the difference was not statistically significant. In mammography with proven cancer, ID MLO images showed significantly higher degree of cancer visibility than standard MLO images. For screening mammography in patients with breast implants, ID MLO view alone is sufficient for MLO projection with reducing the patient's radiation dose without compromising the breast cancer detection capability, especially in dense breasts with subpectoral implants.


Asunto(s)
Implantes de Mama , Neoplasias de la Mama , Femenino , Humanos , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Detección Precoz del Cáncer , Mamografía/métodos
11.
Ultrasonography ; 42(1): 31-40, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36353790

RESUMEN

PURPOSE: The aim of this study was to evaluate the diagnostic value of shear-wave elastography (SWE) combined with Doppler ultrasonography (US) in selecting equivocal breast fibroepithelial lesions (FELs) for follow-up without further excision. METHODS: A retrospective analysis was conducted of 88 patients with equivocal breast FELs (FELs with the possibility of both fibroadenoma [FA] and phyllodes tumor [PT]) diagnosed by core needle biopsy (CNB). For post-CNB treatment, surgical or vacuum-assisted excision was performed on 88 equivocal FELs, of which 56 were diagnosed as FAs and 32 as PTs on histopathology. Mean elasticity (Emean) and vascularity were determined using SWE and Doppler US. The diagnostic performances of B-mode US, SWE, and Doppler US were calculated to differentiate FAs and PTs in the excised equivocal FELs. RESULTS: In the excised equivocal FELs diagnosed by CNB, FAs showed significantly lower median Emean values (36.4 vs. 66.7 kPa, P=0.005) and more frequent low vascularity (0-1 vessel flow signal) (P<0.001) than PTs. For the differentiation of FAs and PTs, the combination of Emean of >60.9 kPa and high vascularity (≥2 vessel flows) showed a sensitivity and negative predictive value of 100%, as well as better performance in other diagnostic values than B-mode US alone (Breast Imaging Reporting and Data System ≥4A) (all P<0.05). CONCLUSION: Equivocal breast FELs showing both low elasticity and low vascularity were not upgraded to PTs upon further excision. Therefore, the combination of SWE and color Doppler US mode might help select patients with equivocal FELs for whom further excision is unnecessary.

12.
Medicine (Baltimore) ; 101(50): e31836, 2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36550794

RESUMEN

To evaluate the frequency and location of abnormal lymph nodes (LNs) in breast cancer patients with a single axillary lymph node (ALN) metastasis on breast magnetic resonance imaging (MRI). We retrospectively reviewed the MRI findings of 219 consecutive patients with breast cancer with single ALN metastasis who were surgically confirmed at our institution between January 2018 and December 2018. The morphological features and locations of the abnormal LN on MRI were analyzed. Pathology reports were reviewed to evaluate the size of the metastases and whether they were sentinel LNs (SLNs). Of the 219 patients with a single ALN metastasis, 56 (25.6%) showed abnormal MRI findings. Of these, 54 (96.4%) had either the lowest or second-lowest LN in the level I axilla. In 184 (91.5%) of 201 patients who underwent SLN biopsy, the metastatic LN were SLN. Macrometastases were found more frequently in cases with abnormal LNs than in those with normal-looking LNs (P = .004). The most frequent morphological feature of metastatic ALNs was a diffuse cortical thickening of 3 to 5 mm (37.5%). Although MRI findings of single ALN metastasis in breast cancer patients are none or minimal, abnormalities are observed in the lowest or second-lowest LN in the lower axilla when present, suggesting the location of the SLNs.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/patología , Biopsia del Ganglio Linfático Centinela/métodos , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Axila/patología , Estudios Retrospectivos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Escisión del Ganglio Linfático , Imagen por Resonancia Magnética
13.
Taehan Yongsang Uihakhoe Chi ; 83(3): 632-644, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-36238508

RESUMEN

Purpose: To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups. Materials and Methods: Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups. Results: The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (US-CNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. US-guided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16-13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7). Conclusion: The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.

14.
Diagnostics (Basel) ; 12(10)2022 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-36292113

RESUMEN

This study aimed to investigate the differences in ultrasound (US) visibility for the localization of clipped metastatic lymph nodes after neoadjuvant chemotherapy (NAC), according to tissue marker type. This single-center retrospective study included 59 consecutive patients with breast cancer who underwent tissue marker insertion for histologically proven metastatic axillary lymph nodes before NAC, between March 2020 and August 2021. Two breast tissue markers were used: UltraClip™ (n = 29) and UltraCor™ Twirl™ (n = 30). The US visibility of tissue markers after NAC and the successful excision rate of the clipped lymph nodes were compared between the two types of tissue markers. UltraCor™ Twirl™ showed better overall US visibility than UltraClip™ after NAC (86.7% vs. 72.4%), but the difference was statistically insignificant. In the absence of residual metastatic lymph nodes on US after NAC (n = 32), UltraCor™ Twirl™ showed significantly better US visibility (83.3%, 15/18) than UltraClip™ (42.9%, 6/14; p = 0.027). The marker type was not associated with the successful excision of the clipped lymph node. UltraCor™ Twirl™ showed better US visibility than UltraClip™ in the metastatic axillary lymph nodes after NAC in the absence of residual suspicious lymph nodes on US.

15.
Medicine (Baltimore) ; 101(41): e31095, 2022 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-36253983

RESUMEN

While the extrinsic factors affecting reproducibility of shear wave elastography (SWE) have been well documented, there are few resources assessing intrinsic characteristics of the lesion affecting the reproducibility and accuracy of SWE. In this regard, this study aimed to evaluate the accuracy of measured elasticity and the reproducibility of SWE according to the lesion size and stiffness. Two breast radiologists examined 20 targets of 4 different levels of stiffness and 5 different sizes (2.5, 4, 7, 11, and 18 mm) in a customized elasticity phantom. The B-mode image, color elastography image, and kPa measurement were obtained twice by each examiner with a 1-week interval. Inter- and intra-observer reproducibility and the accuracy of measured kPa were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Subgroup analysis was run to evaluate the effect of lesion size and stiffness on the reproducibility and accuracy of measured kPa. Inter- and intraobserver reproducibility for measuring kPa showed excellent agreement (ICC: 0.9742 and 0.9582; ICC: 0.9932 and 0.9294). The size and stiffness of the targets did not affect reproducibility. The overall accuracy of measured kPa was very high (ICC: 0.8049). In the subgroup analysis, targets that were ≤4 mm in size showed lower accuracy (ICC: 0.542), whereas targets that were 7 and 11 mm in size showed higher accuracy (ICC: 0.9832 and 0.9656, respectively). SWE shows excellent reproducibility regardless of lesion size or stiffness in phantom targets. The accuracy of measured kPa is high in lesions that are 7 and 11 mm in size but is low in lesions that are ≤4 mm in size.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Recolección de Datos , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados
16.
Korean J Radiol ; 23(11): 1031-1043, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36126953

RESUMEN

OBJECTIVE: To compare digital breast tomosynthesis (DBT) and MRI as an adjunct to full-field digital mammography (FFDM) for the preoperative evaluation of women with breast cancer based on mammographic density. MATERIALS AND METHODS: This retrospective study enrolled 280 patients with breast cancer who had undergone FFDM, DBT, and MRI for preoperative local tumor staging. Three radiologists independently sought the index cancer and additional ipsilateral and contralateral breast cancers using either FFDM alone, DBT plus FFDM, or MRI plus FFDM. Diagnostic performances across the three radiologists were compared among the reading modes in all patients and subgroups with dense (n = 186) and non-dense breasts (n = 94) according to mammographic density. RESULTS: Of 280 patients, 46 (16.4%) had 48 additional (39 ipsilateral and nine contralateral) cancers in addition to the index cancer. For index cancers, both DBT plus FFDM and MRI plus FFDM showed sensitivities of 100% in the non-dense group. In the dense group, DBT plus FFDM showed lower sensitivity than that of MRI plus FFDM (94.6% vs. 99.6%, p < 0.001). For additional ipsilateral cancers, DBT plus FFDM showed specificity and positive predictive value (PPV) of 100% in the non-dense group, but sensitivity and negative predictive value (NPV) were not statistically different from those of MRI plus FFDM (p > 0.05). In the dense group, DBT plus FFDM showed higher specificity (98.2% vs. 94.1%, p = 0.005) and PPV (83.1% vs. 65.4%; p = 0.036) than those of MRI plus FFDM, but lower sensitivity (59.9% vs. 75.3%; p = 0.049). For contralateral cancers, DBT plus FFDM showed higher specificity than that of MRI plus FFDM (99.0% vs. 96.7%, p = 0.014), however, the other values did not differ (all p > 0.05) in the dense group. CONCLUSION: DBT plus FFDM showed an overall higher specificity than that of MRI plus FFDM regardless of breast density, perhaps without substantial loss in sensitivity and NPV in the diagnosis of additional cancers. Thus, DBT may have the potential to be used as a preoperative breast cancer staging tool.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Estudios Retrospectivos , Intensificación de Imagen Radiográfica , Mamografía , Imagen por Resonancia Magnética
17.
J Breast Cancer ; 25(5): 436-442, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35914750

RESUMEN

Multicentric cancer of the pectoral and ectopic breasts is extremely rare, and diagnosing this malignancy remains challenging because axillary breast cancer is easily misdiagnosed as lymph node metastasis. Moreover, there are no established treatment guidelines for this disease. We present our experience with a multicentric breast cancer patient who showed different responses to neoadjuvant chemotherapy (NAC) and underwent surgical treatments that differed from those in previous studies. In our case, the preoperative imaging of both lesions and subsequent core needle biopsy of each lesion were crucial, as these procedures confirm the diagnosis and help decide the chemotherapy regimen based on the subtype. After NAC, the patient underwent right breast-conserving surgery, sentinel lymph node biopsy (SLNB), and excision of accessory breast tissue in the right axilla. SLNB should be the initial step in staging multicentric breast cancer, unless imaging scan shows evidence of lymph node metastasis.

18.
Medicine (Baltimore) ; 101(27): e29547, 2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35801798

RESUMEN

This study aimed to compare the background echotexture (BE) between automated breast ultrasound (ABUS) and handheld breast ultrasound (HHUS) and evaluate the correlation of BE with mammographic (MG) density and background parenchymal enhancement (BPE) on magnetic resonance imaging (MRI). A total of 212 women with newly diagnosed breast cancer who had undergone preoperative ABUS, HHUS, MG, and MRI were included. Two breast radiologists blinded to the menopausal status analyzed the BE of the contralateral breasts of the patients with breast cancer in consensus. The MG density and BPE of breast MRI on the radiologic reports were compared with the BE in the ultrasound. We used the cumulative link mixed model to compare the BE and Spearman rank correlation to evaluate the association between BE with MG density and BPE. BE was more heterogeneous in ABUS than in HHUS (P < .001) and in the premenopausal group than in the postmenopausal group (P < .001). The heterogeneity of BE in the premenopausal group was higher with ABUS than with HHUS (P = .013). BE and MG density showed a moderate correlation in the postmenopausal group, but a weak correlation in the premenopausal group. BE and BPE showed moderate correlations only in the premenopausal group. ABUS showed a more heterogeneous BE, especially in the premenopausal group. Therefore, more attention is required to interpret ABUS screening in premenopausal women.


Asunto(s)
Neoplasias de la Mama , Ultrasonografía Mamaria , Mama/diagnóstico por imagen , Mama/patología , Densidad de la Mama , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Ultrasonografía Mamaria/métodos
19.
Cancers (Basel) ; 14(8)2022 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-35454768

RESUMEN

The purpose of this study was to identify perfusional subregions sharing similar kinetic characteristics from dynamic contrast-enhanced magnetic resonance imaging (MRI) using data-driven clustering, and to evaluate the effect of perfusional heterogeneity based on those subregions on patients' survival outcomes in various risk models. From two hospitals, 308 and 147 women with invasive breast cancer who underwent preoperative MRI between October 2011 and July 2012 were retrospectively enrolled as development and validation cohorts, respectively. Using the Cox-least absolute shrinkage and selection operator model, a habitat risk score (HRS) was constructed from the radiomics features from the derived habitat map. An HRS-only, clinical, combined habitat, and two conventional radiomics risk models to predict patients' disease-free survival (DFS) were built. Patients were classified into low-risk or high-risk groups using the median cutoff values of each risk score. Five habitats with distinct perfusion patterns were identified. An HRS was an independent risk factor for predicting worse DFS outcomes in the HRS-only risk model (hazard ratio = 3.274 [95% CI = 1.378-7.782]; p = 0.014) and combined habitat risk model (hazard ratio = 4.128 [95% CI = 1.744-9.769]; p = 0.003) in the validation cohort. In the validation cohort, the combined habitat risk model (hazard ratio = 4.128, p = 0.003, C-index = 0.760) showed the best performance among five different risk models. The quantification of perfusion heterogeneity is a potential approach for predicting prognosis and may facilitate personalized, tailored treatment strategies for breast cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...