Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
Más filtros










Intervalo de año de publicación
1.
Chem Commun (Camb) ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39081239

RESUMEN

Two new cationic meso-thiazolium-BODIPY-based water-soluble and red-shifted fluorescent probes were constructed for the first time. They can monitor cellular viscosity in dual organelles and show aggregation-induced emission (AIE), which is ascribed to the efficient restricted rotation of meso-thiazolium in viscous or hindered systems. Probe 3 with an N-benzyl group shows better AIE as compared to probe 2 with an N-methyl group.

2.
J Colloid Interface Sci ; 675: 139-149, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38968634

RESUMEN

Transition metal selenides (TMS) have received much attention as anode materials for sodium-ion batteries (SIBs) because of their high theoretical capacity and excellent redox reversibility. However, their further development is constrained by the dissolution of transition metal ions and substantial volume changes experienced during cycling. Herein, the high-entropy Prussian blue analogues were selenized by the vapor infiltration method, resulting in the formation of a core-shell structured high-entropy selenides (HESe-6). The core-shell structure with voids and abundant selenium vacancies on the surface effectively mitigates bulk expansion and enhances electronic conductivity. Furthermore, the high-entropy property endows an ultra-stable crystal structure and inhibits the dissolution of metal ions. The ex-situ EIS and in-situ XRD results show that HESe-6 is able to be reversibly transformed into highly conductive ultrafine metal particles upon Na+ embedding, providing more Na+ reactive active sites. In addition, despite the incorporation of up to seven different elements, it exhibits minimal phase transitions during discharge/charge cycles, effectively mitigating stress accumulation. HESe-6 could retain an ultralong-term stability of 765.83 mAh g-1 after 1000 loops even at 1 A g-1. Furthermore, when coupled with the Na3V2(PO4)2O2F cathode, it maintains a satisfactory charge energy density of 303 Wh kg-1 after 300 cycles, which shows promising application prospect in the future.

3.
Anal Chim Acta ; 1316: 342867, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-38969430

RESUMEN

BACKGROUND: Kanamycin (KAN) residues in animal-derived foods continuously enter the human body, which will pose serious threats to human health such as hearing loss, nephrotoxicity and other complications. Therefore, to sensitively detect KAN residues by a reliable technology is extremely urgent in food quality and safety. Compared with traditional methods being limited by cost and complexity, photoelectrochemical (PEC) biosensors benefit from some merits such as rapid response, excellent sensitivity and good stability. In this study, the construction of a highly efficient PEC platform to realize KAN residues detection is discussed. RESULTS: Herein, a novel p-n heterojunction consisting of flower-like BiOI microspheres and graphite carbon nitride (g-C3N4) nanoflakes was developed to establish a PEC aptasensor for KAN detection at 0 V. The prepared g-C3N4/BiOI heterostructure showed not only significantly enhanced PEC activity due to the larger specific surface area but also greatly increased charge separation efficiency owing to the strong internal electric field. Meanwhile, using g-C3N4/BiOI as a highly efficient photoactive material for binding amine-functionalized aptamers to capture KAN, the photocurrent signals showed a 'turn off' mode to achieve the sensitive detection of KAN. The proposed PEC aptasensor exhibited linear response for KAN from 5 × 10-9 to 3 × 10-7 mol L-1 with a low detection limit of 1.31 × 10-9 mol L-1, and satisfactory recoveries (97.44-107.38 %) were obtained in real food samples analysis. SIGNIFICANCE: This work presented a novel p-n heterojunction-based PEC aptasensor with strong selectivity and stability, rendering it allowed to detect KAN in animal-derived foods including milk, honey and pork. Additionally, the detection range satisfied the MRLs for KAN specified by the national standards, demonstrating the potential application for food analysis. The study provides a new insight into the development of efficient and practical biosensors for antibiotic residues detection.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Grafito , Kanamicina , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Grafito/química , Técnicas Biosensibles/métodos , Kanamicina/análisis , Procesos Fotoquímicos , Límite de Detección , Contaminación de Alimentos/análisis , Compuestos de Nitrógeno/química , Animales , Nitrilos/química , Antibacterianos/análisis , Bismuto
4.
Nat Commun ; 15(1): 4679, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824163

RESUMEN

Tungsten trioxide (WO3) has been recognized as the most promising photocatalyst for highly selective oxidation of methane (CH4) to formaldehyde (HCHO), but the origin of catalytic activity and the reaction manner remain controversial. Here, we take {001} and {110} facets dominated WO3 as the model photocatalysts. Distinctly, {001} facet can readily achieve 100% selectivity of HCHO via the active site mechanism whereas {110} facet hardly guarantees a high selectivity of HCHO along with many intermediate products via the radical way. In situ diffuse reflectance infrared Fourier transform spectroscopy, electron paramagnetic resonance and theoretical calculations confirm that the competitive chemical adsorption between CH4 and H2O and the different CH4 activation routes on WO3 surface are responsible for diverse CH4 oxidation pathways. The microscopic mechanism elucidation provides the guidance for designing high performance photocatalysts for selective CH4 oxidation.

5.
Anal Chem ; 96(22): 9278-9284, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38768425

RESUMEN

Antibody pharmaceuticals have become the most popular immunotherapeutic drugs and are often administered with low serum drug dosages. Hence, the development of a highly sensitive method for the quantitative assay of antibody levels is of great importance to individualized therapy. On the basis of the dual signal amplification by the glycan-initiated site-directed electrochemical grafting of polymer chains (glyGPC), we report herein a novel strategy for the amplified electrochemical detection of antibody pharmaceuticals. The target of interest was affinity captured by a DNA aptamer ligand, and then the glycans of antibody pharmaceuticals were decorated with the alkyl halide initiators (AHIs) via boronate cross-linking, followed by the electrochemical grafting of the ferrocenyl polymer chains from the glycans of antibody pharmaceuticals through the electrochemically controlled atom transfer radical polymerization (eATRP). As the glycans can be decorated with multiple AHIs and the grafted polymer chains are composed of tens to hundreds of electroactive tags, the glyGPC-based strategy permits the dually amplified electrochemical detection of antibody pharmaceuticals. In the presence of trastuzumab (Herceptin) as the target, the glyGPC-based strategy achieved a detection limit of 71.5 pg/mL. Moreover, the developed method is highly selective, and the results of the quantitative assay of trastuzumab levels in human serum are satisfactory. Owing to its uncomplicated operation and cost-effectiveness, the glyGPC-based strategy shows great promise in the amplified electrochemical detection of antibody pharmaceuticals.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Electroquímicas , Trastuzumab , Técnicas Electroquímicas/métodos , Humanos , Trastuzumab/química , Trastuzumab/sangre , Aptámeros de Nucleótidos/química , Límite de Detección , Polisacáridos/química , Técnicas Biosensibles/métodos , Polímeros/química
6.
Anal Chem ; 96(14): 5437-5445, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38529794

RESUMEN

The research on fluorescent rotors for viscosity has attracted extensive interest to better comprehend the close relationships of microviscosity variations with related diseases. Although scientists have made great efforts, fluorescent probes for cellular viscosity with both aggregation-induced emissions (AIEs) and large Stokes shifts to improve sensing properties have rarely been reported. Herein, we first report four new meso-C═N-substituted BODIPY-based rotors with large Stokes shifts, investigate their viscosity/AIE characteristics, and perform cellular imaging of the viscosity in subcellular organelles. Interestingly, the meso-C═N-phenyl group-substituted probe 6 showed an obvious 594 nm fluorescence enhancement in glycerol and a moderate 650 nm red AIE emission in water. Further, on attaching CF3 to the phenyl group, a similar phenomenon was observed for 7 with red-shifted emissions, attributed to the introduction of a phenyl group, which plays a key role in the red AIE emissions and large Stokes shifts. Comparatively, for phenyl-group-free probes, both the meso-C═N-trifluoroethyl group and thiazole-substituted probes (8 and 9) exhibited good viscosity-responsive properties, while no AIE was observed due to the absence of phenyl groups. For cellular experiments, 6 and 9 showed good lysosomal and mitochondrial targeting properties, respectively, and were further successfully used for imaging viscosity through the preincubation of monensin and lipopolysaccharide (LPS), indicating that C═N polar groups potentially work as rotatable moieties and organelle-targeting groups, and the targeting difference might be ascribed to increased charges of thiazole. Therefore, in this study, we investigated the structural relationships of four meso-C═N BODIPY-based rotors with respect to their viscosity/AIE characteristics, subcellular-targeting ability, and cellular imaging for viscosity, potentially serving as AIE fluorescent probes with large Stokes shifts for subcellular viscosity imaging.


Asunto(s)
Compuestos de Boro , Colorantes Fluorescentes , Orgánulos , Colorantes Fluorescentes/química , Viscosidad , Tiazoles
7.
Adv Sci (Weinh) ; 11(17): e2309163, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38425147

RESUMEN

Tuning the crystal phase of alloy nanocrystals (NCs) offers an alternative way to improve their electrocatalytic performance, but, how heterometals diffuse and form ordered-phase remains unclear. Herein, for the first time, the mechanism for forming tetrametallic ordered-phase nanoplates (NPLs) is unraveled. The observations reveal that the intermetallic ordered-phase nucleates through crystallinity alteration of the seeds and then propagates by reentrant grooves. Notably, the reentrant grooves act as intermediate NCs for ordered-phase, eventually forming intermetallic PdCuIrCo NPLs. These NPLs substantially outperform for oxygen evolution reaction (221 mV at 10 mA cm-2) and hydrogen evolution reaction (19 mV at 10 mA cm-2) compared to commercial Ir/C and Pd/C catalysts in acidic media. For OER at 1.53 V versus RHE, the PdCuIrCo/C exhibits an enhanced mass activity of 9.8 A mg-1 Pd+Ir (about ten times higher) than Ir/C. For HER at -0. 2 V versus RHE, PdCuIrCo/C shows a remarkable mass activity of 1.06 A mg-1 Pd+Ir, which is three-fold relative to Pd/C. These improvements can be ascribed to the intermetallic ordered-structure with high-valence Ir sites and tensile-strain. This approach enabled the realization of a previously unobserved mechanism for ordered-phase NCs. Therefore, this strategy of making ordered-phase NPLs can be used in diverse heterogeneous catalysis.

8.
Talanta ; 274: 125990, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38552477

RESUMEN

As a product of nonenzymatic glycation, glycated albumin (GA) is a promising serum marker for the short-term glycemic monitoring in patients with diabetes. On the basis of the boronate crosslinking (BCL)-enabled direct labeling of ferrocene (Fc) tags to the nonenzymatically glycated (NEG) sites, we report herein a novel aptamer-based ratiometric electrochemical (apt-REC) platform for the point-of-care (POC) assay of GA. This apt-REC platform is based on the recognition of GA proteins by the methylene blue (MB)-modified aptamer receptors and the labeling of the Fc tags to the NEG sites via the BCL. Using MB as the reference tag and Fc as the quantification tag, the ratio of the oxidation currents (i.e., IFc/IMB) can serve as the yardstick for the ratiometric assay of GA. Due to the presence of tens of the NEG sites, each GA protein can be labeled with tens of quantification tags, permitting the amplified assay in a simple, time-saving, and low-cost manner. The ratiometric signal exhibited a good linear response over the range from 0.1 to 100 µg/mL, with a detection limit of 45.5 ng/mL. In addition to the superior reproducibility and robustness, this apt-REC platform is highly selective (capable of discriminating GA against human serum albumin (HSA)) and applicable to GA assay in serum samples. Due to its low cost, high reproducibility and robustness, simple operation, and high sensitivity and selectivity, this apt-REC platform holds great promise in the POC assay of GA for diabetes management.


Asunto(s)
Ácidos Borónicos , Técnicas Electroquímicas , Albúmina Sérica Glicada , Humanos , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Ácidos Borónicos/química , Reactivos de Enlaces Cruzados/química , Técnicas Electroquímicas/métodos , Productos Finales de Glicación Avanzada/química , Límite de Detección , Albúmina Sérica/química , Albúmina Sérica/análisis , Albúmina Sérica Humana/química , Albúmina Sérica Humana/análisis
9.
Anal Chem ; 96(9): 3914-3924, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38387027

RESUMEN

Wearable, noninvasive sensors enable the continuous monitoring of metabolites in sweat and provide clinical information related to an individual's health and disease states. Uric acid (UA) is a key indicator highly associated with gout, hyperuricaemia, hypertension, kidney disease, and Lesch-Nyhan syndrome. However, the detection of UA levels typically relies on invasive blood tests. Therefore, developing a wearable device for noninvasive monitoring of UA concentrations in sweat could facilitate real-time personalized disease prevention. Here, we introduce 1,3,6,8-pyrene tetrasulfonic acid sodium salt (PyTS) as a bifunctional molecule functionalized with Ti3C2Tx via π-π conjugation to design nonenzymatic wearable sensors for sensitive and selective detection of UA concentration in human sweat. PyTS@Ti3C2Tx provides many oxidation-reduction active groups to enhance the electrocatalytic ability of the UA oxidation reaction. The PyTS@Ti3C2Tx-based electrochemical sensor demonstrates highly sensitive detection of UA in the concentration range of 5 µM-100 µM, exhibiting a lower detection limit of 0.48 µM compared to the uricase-based sensor (0.84 µM). In volunteers, the PyTS@Ti3C2Tx-based wearable sensor is integrated with flexible microfluidic sweat sampling and wireless electronics to enable real-time monitoring of UA levels during aerobic exercise. Simultaneously, it allows for comparison of blood UA levels via a commercial UA analyzer. Herein, this study provides a promising electrocatalyst strategy for nonenzymatic electrochemical UA sensor, enabling noninvasive real-time monitoring of UA levels in human sweat and personalized disease prevention.


Asunto(s)
Técnicas Biosensibles , Nitritos , Elementos de Transición , Dispositivos Electrónicos Vestibles , Humanos , Ácido Úrico/análisis , Titanio/análisis , Sudor/química
10.
Adv Mater ; 36(4): e2308987, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37883889

RESUMEN

Flexible quasi-solid-state sodium ion batteries featuring their low-cost, high safety and excellent mechanical strength have attracted widespread interest in the field of wearable electronic devices. However, the development of such batteries faces great challenges including the construction of interfacial compatible flexible electrode materials and addressing the high safety demands of electrolyte. Here selenium-vacancies regulated bimetallic selenide heterojunctions anchored on waste cotton cloth-derived flexible carbon cloth (FCC) with robust interfacial C-Se-Co/Fe chemical bonds as a flexible anode material (CCFSF) is proposed by ultrafast microwave pyrolysis method. Rich selenium vacancies and CoSe2 /FeSe2-x heterostructures are synchronously formed that can significantly improve ionic and electronic diffusion kinetics. Additionally, a uniform carbon layer coating on the surface of Se-deficient heterostructures endows it with outstanding structural stability. The flexible cathode (PB@FCC) is also fabricated by directly growing Prussian blue nanoparticles on the FCC. Furthermore, an advanced flexible quasi-solid-state Na-ion pouch cell is assembled by coupling CCFSF anode, PB@FCC cathode with P(VDF-HFP)-based gel polymer electrolyte. The full cell not only demonstrates excellent energy storage performance but also robust mechanical flexibility and safety. The present work offers an effective avenue to achieve high safety flexible energy storage device, promoting the development of flexible wearable electronic devices.

11.
J Colloid Interface Sci ; 658: 459-467, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38118192

RESUMEN

Developing high mass loading cathodes with high capacity and durable life cycles is greatly worthwhile and challenging for alkaline aqueous rechargeable Zn-based batteries (AAZBs). Herein, we demonstrate an efficient zinc-induced strategy to rationally develop Zn-Ni-Co carbonate hydroxides/hydroxides heterostructure nanosheet array with an extremely high mass loading of 9.2 mg cm-2 on Ni foam (ZNC/NF) as such a superior cathode for AAZBs. It is discovered that Ni-Co hydroxide nanowires can be transformed into Zn-Ni-Co carbonate hydroxides/hydroxides heterostructure nanosheet with rich defect structures after the introduction of Zn during the synthetic process. The formed heterostructures and rich defect structures can enhance ion and electron transfer efficiency, thus ensuring the excellent electrochemical performance under high loading condition. Consequently, the ZNC/NF//Zn battery shows an outstanding areal capacity of 2.1 mAh cm-2 at 5 mA cm-2, with an ultrahigh energy density of 3.6 mWh cm-2. Moreover, the battery can still retain a high capacity of 0.42 mAh cm-2 after 5000 cycles at 50 mA cm-2, suggesting strong long-term cycling stability. This research enables pave the way for the rational design and manufacture of advanced electrode materials with large mass loadings.

12.
Small Methods ; : e2301490, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38063782

RESUMEN

Defects in the crystal structure of nanomaterials are important for their diverse applications. As, defects in 2D framework allow surface confinement effects, efficient molecular accessibility, high surface-area to volume-ratio and lead to higher catalytic activity, but it is challenging to expose defects of specific metal on the surface of 2D alloy and find the correlation between defective structure and electrocatalytic properties with atomic precision. Herein, the work paves the way for the controlled synthesis of ultrathin porous Ir-Cu nanosheets (NSs) with selectively iridium (Ir) rich defects to boost their performance for acidic oxygen evolution reaction (OER). X-ray absorption spectroscopy reveals that the oxidized states of Ir in defects of porous NSs significantly impact the electronic structure and decline the energy barrier. As a result, porous Ir-Cu/C NSs deliver improved OER activity with an overpotential of 237 mV for reaching 10 mA cm-2 and exhibit significantly higher mass activity than benchmark Ir/C under acidic conditions. Therefore, the present work highlights the concept of constructing a selective noble metal defect-rich open structure for catalytic applications.

13.
Mater Horiz ; 10(12): 5869-5880, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-37861418

RESUMEN

The exploration of advanced photocatalysts for antibiotic degradation is critical, but it remains a challenge due to the lack of rational structural design and in-depth insights into molecular oxygen activation. Water-floating photocatalysts could be one of the best choices owing to their technical features in terms of reasonability and efficiency involving a high oxygenation of photocatalyst surface, fully solar irradiation, and simple recycling and reuse. Herein, a floatable litchi-like architecture of a polystyrene-sphere-supported TiO2/Bi2O3 (PS@TiO2/Bi2O3) S-scheme heterojunction was skillfully constructed and evaluated for photodegradation of model tetracycline (TC) antibiotics. By integrating the advantages of floatability and S-scheme, the TC removal rate of the optimal PS@TiO2/Bi2O3-0.4 catalyst can reach 88.4% under 1 h illumination, which is higher than that of pristine Bi2O3 (60.8%) and PS@TiO2 (40.1%). Moreover, PS@TiO2/Bi2O3-0.4 exhibits high recyclability and stability, and there is no significant loss of activity after five cycles of repeated use. With the aid of liquid chromatography-mass spectrometry analysis and density functional theory calculations, a reasonable degradation pathway for TC was proposed. The present work provides a recyclable and efficient approach for the photodegradation of TC, expecting to guide the innovative exploitation of other environmental systems.

14.
Anal Chem ; 95(37): 14094-14100, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37672684

RESUMEN

The rapid quantification of therapeutic monoclonal antibodies (mAbs) is of great significance to their pharmacokinetics/pharmacodynamics (PK/PD) research and the personalized medication for disease treatment. Taking advantage of the direct decoration of tens of redox tags to the target of interest, we illustrate herein an amplification-free ratiometric electrochemical aptasensor for the point-of-care (POC) detection of trace amounts of therapeutic mAbs. The POC detection of therapeutic mAbs involved the use of the methylene blue (MB)-conjugated aptamer as the affinity element and the decoration of therapeutic mAbs with ferrocene (Fc) tags via the boronate crosslinking, in which the MB-derived peak current was used as the reference signal, and the peak current of the Fc tag was used as the output signal. As each therapeutic mAb carries tens of diol sites for the site-specific decoration of the Fc output tags, the boronate crosslinking enabled the amplification-free detection, which is cost-effective and quite simple in operation. In the presence of bevacizumab (BevMab) as the target, the resulting ratiometric signal (i.e., the IFc/IMB value) exhibited a good linear response over the range of 0.025-2.5 µg/mL, and the limit of detection (LOD) of the electrochemical aptasensor was 6.5 ng/mL. Results indicated that the aptamer-based affinity recognition endowed the detection of therapeutic mAbs with high selectivity, while the ratiometric readout exhibited satisfactory reproducibility and robustness. Moreover, the ratiometric electrochemical aptasensor is applicable to the detection of therapeutic mAbs in serum samples. Taking together, the amplification-free ratiometric electrochemical aptasensor holds great promise in the POC detection of therapeutic mAbs.


Asunto(s)
Anticuerpos Monoclonales , Tetranitrato de Pentaeritritol , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Bevacizumab , Azul de Metileno , Oligonucleótidos
15.
Angew Chem Int Ed Engl ; 62(43): e202312076, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37667537

RESUMEN

The effective conversion of carbon dioxide (CO2 ) and nitrogen (N2 ) into urea by photocatalytic reaction under mild conditions is considered to be a more environmentally friendly and promising alternative strategies. However, the weak adsorption and activation ability of inert gas on photocatalysts has become the main challenge that hinder the advancement of this technique. Herein, we have successfully established mesoporous CeO2-x nanorods with adjustable oxygen vacancy concentration by heat treatment in Ar/H2 (90 % : 10 %) atmosphere, enhancing the targeted adsorption and activation of N2 and CO2 by introducing oxygen vacancies. Particularly, CeO2 -500 (CeO2 nanorods heated treatment at 500 °C) revealed high photocatalytic activity toward the C-N coupling reaction for urea synthesis with a remarkable urea yield rate of 15.5 µg/h. Besides, both aberration corrected transmission electron microscopy (AC-TEM) and Fourier transform infrared (FT-IR) spectroscopy were used to research the atomic surface structure of CeO2 -500 at high resolution and to monitor the key intermediate precursors generated. The reaction mechanism of photocatalytic C-N coupling was studied in detail by combining Density Functional Theory (DFT) with specific experiments. We hope this work provides important inspiration and guiding significance towards highly efficient photocatalytic synthesis of urea.

16.
Biosensors (Basel) ; 13(9)2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37754093

RESUMEN

Sesamol (SM) is a potent natural antioxidant that can quench free radicals and modulate the cholinergic system in the brain, thereby ameliorating memory and cognitive impairment in Alzheimer's disease patients. Moreover, the total antioxidant capacity can be amplified by synergistic interactions between different antioxidants. Here, we constructed a ternary heterojunction graphitic carbon nitride/cupric sulfide/titanium dioxide (g-C3N4/CuS/TiO2) photoelectrochemical (PEC) sensor for the quantification of SM and its synergistic interactions with other antioxidants. Crucially, the Schottky barrier in ternary semiconductors considerably enhances electron transfer. The PEC sensor showed a wide linear range for SM detection, ranging from 2 to 1277 µmol L-1, and had a limit of detection of 1.8 µmol L-1. Remarkably, this sensing platform could evaluate the synergism between SM and five typical lipid-soluble antioxidants: tert-butyl hydroquinone, vitamin E, butyl hydroxyanisole, propyl gallate, and butylated hydroxytoluene. Owing to its low redox potential, SM could reduce antioxidant radicals and promote their regeneration, which increased the overall antioxidant performance. The g-C3N4/CuS/TiO2 PEC sensor exhibited high sensitivity, satisfactory selectivity, and stability, and was successfully applied for SM determination in both soybean and peanut oils. The findings of this study provide guidance for the development of nutritional foods, nutrition analysis, and the treatment of diseases caused by free radicals.


Asunto(s)
Antioxidantes
17.
Front Microbiol ; 14: 1195448, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37333650

RESUMEN

In recent years, terahertz (THz) imaging has attracted much attention because of its ability to obtain physical and chemical information in a label-free, noninvasive and nonionizing manner. However, the low spatial resolution of traditional THz imaging systems and the weak dielectric response of biological samples hinder the application of this technology in the biomedical field. In this paper, we report a new THz near-field imaging method for a single bacteria, through the coupling effect of nanoscale radius of probe and platinum gold substrate, which greatly enhances THz near-field signal of biological samples. A THz super-resolution image of bacteria has been successfully obtained by strictly controlling the relevant test parameters such as tip parameters and driving amplitude. By analyzing and processing the THz spectral image, the morphology and inner structure of bacteria have been observed. The method has been used to detect and identify Escherichia coli represented by Gram-negative bacteria and Staphylococcus aureus represented by Gram-positive bacteria. This application provides a new label-free, noninvasive and nonionizing testing protocol for the detection of single bacteria.

18.
Anal Chem ; 95(25): 9646-9653, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37311071

RESUMEN

Fluorescent rotors with aggregation-induced emission (AIE) and organelle-targeting properties have attracted great attention for sensing subcellular viscosity changes, which could help understand the relationships of abnormal fluctuations with many associated diseases. Despite the numerous efforts spent, it remains rare and urgent to explore the dual-organelle targeting probes and their structural relationships with viscosity-responsive and AIE properties. Therefore, in this work, we reported four meso-five-membered heterocycle-substituted BODIPY-based fluorescent probes, explored their viscosity-responsive and AIE properties, and further investigated their subcellular localization and viscosity-sensing applications in living cells. Interestingly, the meso-thiazole probe 1 showed both good viscosity-responsive and AIE (in pure water) properties and could successfully target both mitochondria and lysosomes, further imaging cellular viscosity changes by treating lipopolysaccharide and nystatin, attributing to the free rotation and potential dual-organelle targeting ability of the meso-thiazole group. The meso-benzothiophene probe 3 with a saturated sulfur only showed good viscosity-responsive properties in living cells with the aggregation-caused quenching effect and no subcellular localization. The meso-imidazole probe 2 showed the AIE phenomenon without an obvious viscosity-responsive property with a C═N bond, while the meso-benzopyrrole probe 4 displayed fluorescence quenching in polar solvents. Therefore, for the first time, we investigated the structure-property relationships of four meso-five-membered heterocycle-substituted BODIPY-based fluorescent rotors with viscosity-responsive and AIE properties, and among these, 1 with a C═N bond and a saturated sulfur on the meso-thiazole, potentially contributing to their corresponding AIE and viscosity-responsive properties, served as a sensitive AIE fluorescent rotor for imaging dual-organelle viscosity in both mitochondria and lysosomes.


Asunto(s)
Colorantes Fluorescentes , Orgánulos , Colorantes Fluorescentes/química , Viscosidad , Diagnóstico por Imagen
19.
Biosensors (Basel) ; 13(5)2023 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-37232887

RESUMEN

Herein, a novel, recognition-molecule-free electrode based on Ti3C2/TiO2 composites was synthesized using Ti3C2 as the Ti source and TiO2 in situ formed by oxidation on the Ti3C2 surface for the selective detection of dopamine (DA). The TiO2 in situ formed by oxidation on the Ti3C2 surface not only increased the catalytically active surface for DA binding but also accelerated the carrier transfer due to the coupling between TiO2 and Ti3C2, resulting in a better photoelectric response than pure TiO2. Through a series of experimental conditions optimization, the photocurrent signals obtained by the MT100 electrode were proportional to the DA concentration from 0.125 to 400 µM, with a detection limit estimated at 0.045 µM. We also monitored DA in human blood serum samples using the MT100 electrode. The results showed good recovery, demonstrating the promising use of the sensor for the analysis of DA in real samples.


Asunto(s)
Dopamina , Titanio , Humanos , Dopamina/análisis , Titanio/química , Oxidación-Reducción
20.
Talanta ; 262: 124623, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37244238

RESUMEN

Here, we propose a fast and sensitive coulometric signal transduction method for ion-selective electrodes (ISEs) by utilizing a two-compartment cell. A potassium ion-selective electrode (K+-ISE) was connected as reference electrode (RE) and placed in the sample compartment. A glassy carbon (GC) electrode coated with poly(3,4-ethylenedioxythiophene) (GC/PEDOT), or reduced graphene oxide (GC/RGO), was connected as working electrode (WE) and placed in the detection compartment together with a counter electrode (CE). The two compartments were connected with an Ag/AgCl wire. The measured cumulated charge was amplified by increasing the capacitance of the WE. The observed slope of the cumulated charge with respect to the change of the logarithm of the K+ ion activity was linearly proportional to the capacitance of the GC/PEDOT and GC/RGO, estimated from impedance spectra. Furthermore, the sensitivity of the coulometric signal transduction using a commercial K+-ISE with internal filling solution as RE and GC/RGO as WE allowed to decrease the response time while still being able to detect a 0.2% change in K+ concentration. The coulometric method utilizing a two-compartment cell was found to be feasible for the determination of K+ concentrations in serum. The advantage of this two-compartment approach, compared to the coulometric transduction described earlier, was that no current passed through the K+-ISE that was connected as RE. Therefore, current-induced polarization of the K+-ISE was avoided. Furthermore, since the GCE/PEDOT and GCE/RGO (used as WE) had a low impedance, the response time of the coulometric response decreased from minutes to seconds.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA