Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cataract Refract Surg ; 50(1): 64-71, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37702514

RESUMEN

PURPOSE: To compare the vault predictability of most available implantable collamer lens (ICL) sizing nomograms and identify which preoperative measurements are predictive of vault. SETTING: Private practice in Draper, Utah. DESIGN: Retrospective chart review. METHODS: This study was a retrospective analysis of 209 eyes of 106 patients who underwent STAAR Surgical ICL implantation. Analyses were performed based on the availability of preoperative parameters, varying the number of eyes for each test. Mean absolute error (MAE) of predicted vs actual postoperative vault was calculated for each nomogram. The frequency of Kim, Rocamora (least absolute shrinkage and selection operator-optical coherence tomography), Russo, and Reinstein recommending the correct ICL size in instances when Parkhurst, optimized white-to-white (WTW), and STAAR could not recommend a definitive ICL size was determined. Univariate and multivariate linear regression analysis was performed between preoperative measurements and vault. RESULTS: The Kim, Rocamora, Russo, and Reinstein nomograms had significantly lower MAE of predicted vs actual postoperative vault than the KSV2 and Nakamura V3 nomograms. The Russo formula most frequently recommended the correct ICL size when the Parkhurst, Optimized WTW, and STAAR nomograms could not provide ICL size recommendations. At the 0.05 significance level, anterior chamber depth (ACD), ciliary body inner diameter (CBID), and pupil diameter were the parameters found to have significant correlation with postoperative vault. CONCLUSIONS: The Kim, Rocamora, Russo, and Reinstein nomograms were the most predictive of vault. Additionally, ACD, CBID, and pupil diameter were found to be significantly correlated with vault and should be considered for use in future ICL sizing nomograms.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Nomogramas , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Miopía/cirugía , Cuerpo Ciliar
2.
Cureus ; 15(7): e42744, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37529827

RESUMEN

Purpose To determine the accuracy of three smartphone applications in the measurement of interpupillary distance (IPD). Methods This study compared measurements from three smartphone applications to measurements obtained by a single trained examiner using a digital pupilometer in 44 subjects. The mean absolute error (MAE) of IPD prediction by each application was compared. Additionally, the frequency at which each application measured IPD within ± 0.05 mm, ± 0.10 mm, ± 0.25 mm, ± 0.50 mm, ± 0.75 mm, and ± 1.00 mm of the digital pupilometer measurement was determined. Results The Eye Measure (Dotty Digital, Sydney, New South Wales, Australia) and Warby Parker (Warby Parker, New York, New York) applications had significantly lower MAE of IPD measurements (0.511364 mm) compared to the PDCheck AR (EyeQue Corp., Newark, California) application (1.375 mm). The Warby Parker application most frequently obtained accurate IPD measurements within the following ranges: ± 0.05 mm, ± 0.10 mm, ± 0.25 mm, ± 0.50 mm, ± 0.75 mm, and ± 1.00 mm. Conclusion Of the three smartphone applications compared in this study, the Warby Parker application performed to the highest degree of accuracy and may serve as an adequate alternative when conventional IPD measurement methods are either unavailable or unable to be performed accurately.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...