Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Medicine (Baltimore) ; 102(44): e35784, 2023 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-37933005

RESUMEN

RATIONALE: Phacolytic glaucoma (PLG), a secondary open-angle glaucoma caused by high molecular weight proteins leaking through the capsule of a hypermature cataract. Leakage of liquefied lens cortex behind the posterior capsule is rare. In this paper, we review a case of phacolytic glaucoma in the lens cortex behind posterior capsule. PATIENT CONCERNS: This case report describes a 79-year-old male patient with a 7-year history of progressive blurred vision and a 1-day history of distended in his left eye. He underwent phacoemulsification combined with intraocular lens implantation at our facility 7 years ago. DIAGNOSES: The patient had lower vision (light perception vision) and increased intraocular pressure (IOP) (60 mmHg) in the left eye. Auxiliary inspection found that the left eye had deep anterior chamber depth (around 1 corneal thickness of the peripheral AC angle) as well as vitreous and aqueous humor opacity in the left eye. Combining the clinical symptoms and examinations, we made the diagnosis of PLG in the left eye. INTERVENTIONS: The patient underwent trabeculectomy and extracapsular cataract extraction of the left after a stable ocular condition, during the operation to see that white chyous cortex was visible under the posterior capsule and posterior capsule membrane of the lens was avulsed circularly. OUTCOMES: The postoperative condition was stable. During the follow up of 3 months, the IOP of the left eye was stable without ocular discomfort. LESSONS: This case reported a patient with phacolytic glaucoma in the lens cortex behind posterior capsule who underwent successful surgery, indicating spontaneous capsule rupture can occur in the posterior capsules in PLG and when this situation is detected during the operation, the posterior capsule tearing method can be applied to absorb the lens cortex sticking at the posterior surface of the posterior capsule.


Asunto(s)
Extracción de Catarata , Catarata , Glaucoma de Ángulo Abierto , Glaucoma , Anciano , Humanos , Masculino , Catarata/complicaciones , Glaucoma/cirugía , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular
2.
World J Clin Cases ; 10(5): 1623-1629, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35211602

RESUMEN

BACKGROUND: Synovial sarcoma is a malignant mesenchymal neoplasm with variable epithelial differentiation. Most synovial sarcoma cases are reported in young adults and can arise in any body site. Notably, primary orbital synovial sarcoma is rare. CASE SUMMARY: An 8-year-old east Asian girl with 1-month history of gradual painless proptosis and lacrimation of the right eye was admitted. The patient presented with painless proptosis, downward eyeball displacement, and upward movement disorders. According to clinical manifestations, imaging examinations and postoperative immunohistochemical examinations, the diagnosis was monophasic synovial sarcoma with calcification. The patient underwent anterior orbitotomy procedure for removal of the right orbital mass under general anesthesia. The diagnosis of monophasic synovial sarcoma with calcification was confirmed finally through histological and immunohistochemical exam. The follow-up period was 6 mo, and no recurrence was observed during this period. CONCLUSION: Primary orbital monophasic synovial sarcoma with calcification is a rare sarcoma, and clinical manifestations and imaging results are not specific. The tumor may present similar features as a benign tumor. Comprehensive analysis of clinical, radiological, and pathological findings is critically important for making the right diagnosis. Conventional treatment approach for synovial sarcoma is surgical resection with adjuvant or neoadjuvant radiotherapy, which is highly effective for localized tumors.

3.
J Cell Mol Med ; 24(16): 9388-9396, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32649009

RESUMEN

Exosomes are attracting considerable interest in the cardiovascular field as the wide range of their functions is recognized in acute myocardial infarction (AMI). However, the regulatory role of exosomal long non-coding RNAs (lncRNAs) in AMI remains largely unclear. Exosomes were isolated from the plasma of AMI patients and controls, and the sequencing profiles and twice qRT-PCR validations of exosomal lncRNAs were performed. A total of 518 differentially expressed lncRNAs were detected over two-fold change, and 6 kinds of lncRNAs were strikingly elevated in AMI patients with top fold change and were selected to perform subsequent validation. In the two validations, lncRNAs ENST00000556899.1 and ENST00000575985.1 were significantly up-regulated in AMI patients compared with controls. ROC curve analysis revealed that circulating exosomal lncRNAs ENST00000556899.1 and ENST00000575985.1 yielded the area under the curve values of 0.661 and 0.751 for AMI, respectively. Moreover, ENST00000575985.1 showed more significant relationship with clinical parameters, including inflammatory biomarkers, prognostic indicators and myocardial damage markers. Multivariate logistic model exhibited positive association of ENST00000575985.1 with the risk of heart failure in AMI patients. In summary, our data demonstrated that circulating exosomal lncRNAs ENST00000556899.1 and ENST00000575985.1 are elevated in patients with AMI, functioning as potential biomarkers for predicting the prognosis of pateints with AMI.


Asunto(s)
Biomarcadores/sangre , Exosomas/genética , Regulación de la Expresión Génica , Leucocitos Mononucleares/metabolismo , Infarto del Miocardio/diagnóstico , ARN Largo no Codificante/genética , Enfermedad Aguda , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/genética , Pronóstico , ARN Largo no Codificante/sangre , Curva ROC
4.
Chin Med Sci J ; 27(4): 213-9, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23294586

RESUMEN

Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.


Asunto(s)
Angiografía Coronaria , Frecuencia Cardíaca , Estenosis Coronaria , Electrocardiografía , Humanos , Dosis de Radiación
5.
Chin Med Sci J ; 27(4): 225-31, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23294588

RESUMEN

Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv, P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.


Asunto(s)
Angiografía Coronaria , Dosis de Radiación , Electrocardiografía , Humanos , Tomografía Computarizada por Rayos X
6.
Korean J Radiol ; 13(6): 684-93, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23118566

RESUMEN

OBJECTIVE: To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. MATERIALS AND METHODS: Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. RESULTS: There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B (p = 0.001). CONCLUSION: In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria , Electrocardiografía , Frecuencia Cardíaca , Tomografía Computarizada Espiral , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA