Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36243673

RESUMEN

OBJECTIVE: This study compared the clinical usefulness of structured reports (SRs) and free-text reports (FTRs) of lesions depicted on cone beam computed tomography (CBCT) images from the perspectives of report providers and receivers. STUDY DESIGN: In total, 36 CBCT images of jaw lesions obtained between February 2020 and August 2020 were evaluated. A working group of 3 oral and maxillofacial radiologists (OMRs) established a reporting system and prepared reports. Evaluation group I (2 OMRs) wrote SRs and FTRs for each case and assessed the reporting process for the criteria of convenience and organization. Evaluation group II (3 general practitioners [GPs] and 3 oral and maxillofacial surgeons [OMSs]) assessed the reports for the criteria of productivity, consistency, and organization. A 5-point Likert scale was used to assess the usefulness of each report. Scores were statistically compared according to report type with the paired Wilcoxon signed-rank test. RESULTS: The SRs scored significantly higher for all criteria as assessed by evaluation group I and the GPs of group II (P < .001). The FTRs scored significantly higher for productivity and organization as assessed by the OMSs of group II (P = .005 for both criteria). CONCLUSIONS: The clinical usefulness of reports may differ according to roles of the report recipients in diagnosis and treatment.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Humanos , Tomografía Computarizada de Haz Cónico/métodos
2.
Korean J Orthod ; 51(2): 105-114, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33678626

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the relationship between rotational disk displacement (DD) of the temporomandibular joint (TMJ) and the dentoskeletal morphology. METHODS: Women aged > 17 years were included in this study. Each subject had a primary complaint of malocclusion and underwent routine cephalometric examinations. They were divided into five groups according to the findings on sagittal and coronal magnetic resonance images of their TMJs: bilateral normal disk position, bilateral anterior DD with reduction (ADDR), bilateral rotational DD with reduction (RDDR), bilateral anterior DD without reduction (ADDNR), and bilateral rotational DD without reduction (RDDNR). Twenty-three cephalometric variables were analyzed, and the Kruskal-Wallis test was used to evaluate differences in the dentoskeletal morphology among the five groups. RESULTS: Patients with TMJ DD exhibited a hyperdivergent pattern with a retrognathic mandible, unlike those with a normal disk position. These specific skeletal characteristics were more severe in patients exhibiting DD without reduction than in those with reduction, regardless of the presence of rotational DD. Rotational DD significantly influenced horizontal and vertical skeletal patterns only in the stage of DD with reduction, and the mandible exhibited a more backward position and rotation in patients with RDDR than in those with ADDR. However, there were no significant dentoskeletal differences between ADDNR and RDDNR. CONCLUSIONS: The results of this study suggest that rotational DD of TMJ plays an important role in the dentoskeletal morphology, particularly in patients showing DD with reduction.

3.
Sci Rep ; 10(1): 21012, 2020 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-33273597

RESUMEN

The maxillary sinus is the largest of the four paranasal sinuses in humans, and its close proximity to the teeth means that caution is required during dental treatment. In particular, implant surgeries involving the maxillary posterior teeth should include evaluating the inferior part of the maxillary sinus. The purpose of this study is to evaluate the differences by comparing the inferior part of the maxillary sinus based on the nasal cavity floor (NCF) between patients (male 30, female 30) genders through the use of the three-dimensional (3-D) program that can facilitate 3-D visualizations. The present study results obtained from 3-D visualizations using cone beam computed tomography (CBCT) data showed that the inferior part of the maxillary sinus was mostly larger in males than in females. In addition, the utilization of 3-D visualization data was more likely to assure accuracy than when using data obtained by two-dimensional (2-D) imaging. Therefore, 3-D visualizations of the inferior part of the maxillary sinus will contribute to accurate analyses of its anatomical structure during implant surgery and other operations. Further studies utilizing 3-D visualization will yield useful fundamental data and guidelines for future research.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Seno Maxilar/diagnóstico por imagen , Adulto , Variación Anatómica , Implantación Dental/métodos , Femenino , Humanos , Masculino , Seno Maxilar/anatomía & histología , Cavidad Nasal/anatomía & histología , Cavidad Nasal/diagnóstico por imagen
4.
Imaging Sci Dent ; 48(2): 147-152, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29963487

RESUMEN

Synovial chondromatosis is a rare metaplastic disease affecting the joints, including the temporomandibular joint (TMJ). Since its symptoms are similar to those of temporomandibular disorders, a careful differential diagnosis is essential. A 50-year-old male patient was referred with the chief complaint of pain and radiopaque masses around the left TMJ on panoramic radiography. Clinically, pre-auricular swelling and resting pain was found, without limitation of mouth opening. On cone-beam computed tomographic images, multiple calcified nodules adjacent to the TMJ and bone proliferation with sclerosis at the articular fossa and eminence were found. T2-weighted magnetic resonance images showed multiple signal-void nodules with high signal effusion in the superior joint space and thickened cortical bone at the articular fossa and eminence. The calcified nodules were removed by surgical excision, but the hypertrophic articular fossa and eminence remained. A histopathological examination confirmed the diagnosis. The patient was followed up few months later without recurrence.

5.
Imaging Sci Dent ; 48(1): 21-30, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29581946

RESUMEN

PURPOSE: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. MATERIALS AND METHODS: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. RESULTS: The effective doses at CBCT for 1 large (20.0 cm×17.9 cm) and 2 medium FOVs (15.4 cm×15.4 cm and 10.2 cm×10.2 cm) calculated by the PCXMC software were 181, 300, and 158 µSv, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. CONCLUSION: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.

6.
J Periodontal Implant Sci ; 47(3): 154-164, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28680711

RESUMEN

PURPOSE: Measurement of the root surface area (RSA) is important in periodontal treatment and for the evaluation of periodontal disease as a risk factor for systemic disease. The aim of this study was to measure the RSA at 6 mm below the cementoenamel junction (CEJ) using the Mimics software (Materialise, Leuven, Belgium). METHODS: We obtained cone-beam computed tomography (CBCT) data from 33 patients who had visited the Department of Oral and Maxillofacial Radiology of Dankook University Dental Hospital. The patients comprised 17 men and 16 women aged from 20 to 35 years, with a mean age of 24.4 years. Only morphologically intact teeth were included in our data. Because the third molars of the maxilla and mandible have a high deformation rate and were absent in some participants, they were not included in our research material. RESULTS: The CBCT data were reconstructed into 3-dimensional (3D) teeth models using the Mimics software, and the RSA at 6 mm below the CEJ was separated and measured using 3-Matic (Materialise). In total, 924 3D teeth models were created, and the area at 6 mm below the CEJ could be isolated in all the models. The area at 6 mm below the CEJ was measured in all teeth from the 33 patients and compared based on sex and position (maxilla vs. mandible). CONCLUSIONS: In this study, we demonstrated that it was feasible to generate 3D data and to evaluate RSA values using CBCT and the Mimics software. These results provide deeper insights into the relationship between periodontal inflammatory burden and systemic diseases.

7.
Imaging Sci Dent ; 44(3): 229-36, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25279344

RESUMEN

PURPOSE: To investigate the prevalence of bifid and trifid mandibular canals using cone-beam computed tomography (CBCT) images, and to measure their length, diameter, and angle. MATERIALS AND METHODS: CBCT images of 500 patients, involving 755 hemi-mandibles, were used for this study. The presence and type of bifid mandibular canal was evaluated according to a modified classification of Naitoh et al. Prevalence rates were determined according to age group, gender, and type. Further, their diameter, length, and angles were measured using PACSPLUS Viewer and ImageJ 1.46r. Statistical analysis with chi-squared and analysis of variance (ANOVA) tests was performed. RESULTS: Bifid and trifid mandibular canals were found in 22.6% of the 500 patients and 16.2% of the 755 sides. There was no significant difference between genders and among age groups. The retromolar canal type accounted for 71.3% of the identified canals; the dental canal type, 18.8%; the forward canal type, 4.1%; and the trifid canal type, 5.8%. Interestingly, seven cases of the trifid canal type, which has been rarely reported, were observed. The mean diameter of the bifid and trifid mandibular canals was 2.2 mm and that of the main mandibular canal was 4.3 mm. Their mean length was 16.9 mm; the mean superior angle was 149.2°, and the mean inferior angle was 37.7°. CONCLUSION: Bifid and trifid mandibular canals in the Korean population were observed at a relatively high rate through a CBCT evaluation, and the most common type was the retromolar canal. CBCT is suggested for a detailed evaluation of bifid and trifid mandibular canals before mandibular surgery.

8.
Imaging Sci Dent ; 44(1): 31-5, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24701456

RESUMEN

PURPOSE: This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. MATERIALS AND METHODS: Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. RESULTS: There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). CONCLUSION: Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

9.
Restor Dent Endod ; 37(3): 160-4, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23429415

RESUMEN

OBJECTIVES: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. MATERIALS AND METHODS: Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. RESULTS: The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. CONCLUSIONS: When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

10.
Imaging Sci Dent ; 42(4): 237-42, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23301210

RESUMEN

PURPOSE: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. MATERIALS AND METHODS: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. RESULTS: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 mGycm(2) (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 mGycm(2) (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). CONCLUSION: We recommend 3.1 mGy (PED), 87.4 mGycm(2) (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...