Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Diabetologia ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38780786

RESUMEN

AIMS/HYPOTHESIS: Our study aims to uncover glycaemic phenotype heterogeneity in type 1 diabetes. METHODS: In the Study of the French-speaking Society of Type 1 Diabetes (SFDT1), we characterised glycaemic heterogeneity thanks to a set of complementary metrics: HbA1c, time in range (TIR), time below range (TBR), CV, Gold score and glycaemia risk index (GRI). Applying the Discriminative Dimensionality Reduction with Trees (DDRTree) algorithm, we created a phenotypic tree, i.e. a 2D visual mapping. We also carried out a clustering analysis for comparison. RESULTS: We included 618 participants with type 1 diabetes (52.9% men, mean age 40.6 years [SD 14.1]). Our phenotypic tree identified seven glycaemic phenotypes. The 2D phenotypic tree comprised a main branch in the proximal region and glycaemic phenotypes in the distal areas. Dimension 1, the horizontal dimension, was positively associated with GRI (coefficient [95% CI]) (0.54 [0.52, 0.57]), HbA1c (0.39 [0.35, 0.42]), CV (0.24 [0.19, 0.28]) and TBR (0.11 [0.06, 0.15]), and negatively with TIR (-0.52 [-0.54, -0.49]). The vertical dimension was positively associated with TBR (0.41 [0.38, 0.44]), CV (0.40 [0.37, 0.43]), TIR (0.16 [0.12, 0.20]), Gold score (0.10 [0.06, 0.15]) and GRI (0.06 [0.02, 0.11]), and negatively with HbA1c (-0.21 [-0.25, -0.17]). Notably, socioeconomic factors, cardiovascular risk indicators, retinopathy and treatment strategy were significant determinants of glycaemic phenotype diversity. The phenotypic tree enabled more granularity than traditional clustering in revealing clinically relevant subgroups of people with type 1 diabetes. CONCLUSIONS/INTERPRETATION: Our study advances the current understanding of the complex glycaemic profile in people with type 1 diabetes and suggests that strategies based on isolated glycaemic metrics might not capture the complexity of the glycaemic phenotypes in real life. Relying on these phenotypes could improve patient stratification in type 1 diabetes care and personalise disease management.

2.
Reprod Sci ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38605263

RESUMEN

To evaluate the predictive value of the sFlt-1/PlGF ratio for the prediction of preeclampsia in women with preexisting diabetes mellitus. This is a monocentric retrospective observational study conducted between January 2018 and December 2020. All singleton pregnancies with preexisting diabetes mellitus, who had a dosage of the sFlt-1/PlGF ratio between 30 and 34 + 6 weeks of gestation were included. The principal outcome was preeclampsia. The secondary outcomes were preterm preeclampsia, gestational hypertension, placental abruption, intrauterine fetal death, IUGR, small for gestational age and a composite outcome named "hypertensive disorder of pregnancy" including gestational hypertension, preeclampsia and HELLP syndrome (hemolysis, elevated liver enzymes and low platelet count). Of 63 patients, 22% presented preeclampsia. The area under the curve of sFlt-1/PlGF ratio was 0.90 (95% CI: 0.79-0.96) for the prediction of preeclampsia. The receiver operator characteristic analysis suggested that the optimal sFlt-1/PlGF cutoff to predict preeclampsia was 29, with a sensitivity of 86% (95% CI: 60.1-96.0) and a specificity of 92% (95% CI: 80.8-96.8). A cut-off of 38 provided a sensitivity of 71% (95% CI: 45.4-88.3), a specificity of 92% (95% CI: 80.8-96.8). Further analysis using multivariable methods revealed nephropathy was significantly associated with PE (p = 0.014). The use of the sFlt-1/PlGF ratio during the third trimester of pregnancy seems to be of interest as a prognostic tool to improve multidisciplinary management of patients with preexisting diabetes mellitus.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38350126

RESUMEN

Introduction: Most continuous subcutaneous insulin infusion (CSII) catheters (KT) are changed every 3 days. This study aims at evaluating whether KT changes impact glucose control while under open-loop (OL) or automated insulin delivery (AID) modes. Methods: We included patients with type 1 diabetes who used Tandem t:slim x2 insulin pump and Dexcom G6 glucose sensor for 20 days in OL, then as AID. CSII and sensor glucose data in OL and for the past 20 days of 3-month AID were retrospectively analyzed. The percentage of time spent with sensor glucose above 180 mg/dL (%TAR180) was compared between the calendar day of KT change (D0), the next day (D1), and 2 days later (D2). Values were adjusted for age, gender, body mass index (BMI), hemoglobin A1c (HbA1c) at inclusion, and %TAR180 for the 2 h before KT change. Results: A total of 1636 KT changes were analyzed in 134 patients: 72 women (54%), age: 35.6 ± 15.7 years, BMI: 25.2 ± 4.7 kg/m2, and HbA1c: 7.5 ± 0.8%. %TAR180 in the 2 h before the KT change was 51.3 ± 37.0% in OL and 33.2 ± 30.0% in AID mode. In OL, significant absolute increases of %TAR180 at D0 versus D1 (+6.9%; P < 0.0001) or versus D2 (+6.8%; P < 0.0001) were observed. In AID, significant absolute increases of %TA180R at D0 versus D1 (+4.8%; P < 0.0001) or versus D2 (+4.2%; P < 0.0001) were also observed. Conclusion: This study shows an increase in time spent in hyperglycemia on the day of the KT change both in OL and AID modes. This additional information should be taken into account to improve current AID algorithms. ClinicalTrials.gov: NCT04939766.

5.
Diabetes Obes Metab ; 26(2): 622-630, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37921083

RESUMEN

AIM: The study aim was to evaluate the feasibility, safety and efficacy of automated insulin delivery (AID) assisted by home health care (HHC) services in people with type 2 diabetes unable to manage multiple daily insulin injections (MDI) at home on their own. PATIENTS AND METHODS: This was an open label, multicentre, randomized, parallel group trial. In total, 30 adults with type 2 diabetes using MDI and requiring nursing support were randomly allocated to AID or kept their usual therapy over a 12-week period. Both treatments were managed with the support of HHC services. The primary outcome was the percentage time in the target glucose range of 70-180 mg/dl (TIR). Secondary outcomes included other continuous glucose monitoring metrics, glycated haemoglobin (HbA1c) levels, daily insulin doses, body weight, and of quality of life scores, fear of hypoglycaemia and satisfaction questionnaires. RESULTS: Age (69.7 vs. 69.3 years) and HbA1c (9.25 vs. 9.0) did not differ in MDI and AID at baseline. Compared with MDI, AID resulted in a significant increase in TIR by 27.4% [95% CI (15.0-39.8); p < .001], a decrease in time above range by 27.7% and an unchanged time below range of <1%. A between-group difference in HbA1c was 1.3% favouring AID. Neither severe hypoglycaemia nor ketoacidosis occurred in either group. Patient and caregiver satisfaction with AID was high. CONCLUSIONS: AID combined with tailored HHC services significantly improved glycaemic control with no safety issues in people with type 2 diabetes previously under an MDI regimen with HHC. AID should be considered a safe option in these people when lacking acceptable glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Servicios de Atención de Salud a Domicilio , Hipoglucemia , Adulto , Humanos , Insulina/efectos adversos , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hemoglobina Glucada , Automonitorización de la Glucosa Sanguínea , Calidad de Vida , Glucemia , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/tratamiento farmacológico , Insulina Regular Humana/uso terapéutico
7.
Diabetologia ; 66(1): 3-22, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36198829

RESUMEN

A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialised for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organisations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organisation has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonisation of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organisations for confirmation.


Asunto(s)
Diabetes Mellitus , Insulina , Humanos , Estados Unidos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus/tratamiento farmacológico , Tecnología
8.
Diabetes Care ; 45(12): 3058-3074, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36202061

RESUMEN

A technological solution for the management of diabetes in people who require intensive insulin therapy has been sought for decades. The last 10 years have seen substantial growth in devices that can be integrated into clinical care. Driven by the availability of reliable systems for continuous glucose monitoring, we have entered an era in which insulin delivery through insulin pumps can be modulated based on sensor glucose data. Over the past few years, regulatory approval of the first automated insulin delivery (AID) systems has been granted, and these systems have been adopted into clinical care. Additionally, a community of people living with type 1 diabetes has created its own systems using a do-it-yourself approach by using products commercialized for independent use. With several AID systems in development, some of which are anticipated to be granted regulatory approval in the near future, the joint Diabetes Technology Working Group of the European Association for the Study of Diabetes and the American Diabetes Association has created this consensus report. We provide a review of the current landscape of AID systems, with a particular focus on their safety. We conclude with a series of recommended targeted actions. This is the fourth in a series of reports issued by this working group. The working group was jointly commissioned by the executives of both organizations to write the first statement on insulin pumps, which was published in 2015. The original authoring group was comprised by three nominated members of the American Diabetes Association and three nominated members of the European Association for the Study of Diabetes. Additional authors have been added to the group to increase diversity and range of expertise. Each organization has provided a similar internal review process for each manuscript prior to submission for editorial review by the two journals. Harmonization of editorial and substantial modifications has occurred at both levels. The members of the group have selected the subject of each statement and submitted the selection to both organizations for confirmation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Automonitorización de la Glucosa Sanguínea , Consenso , Glucemia , Sistemas de Infusión de Insulina , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina Regular Humana/uso terapéutico , Glucosa/uso terapéutico , Tecnología , Hipoglucemiantes/uso terapéutico
10.
Diabetes Ther ; 13(4): 693-708, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35133640

RESUMEN

INTRODUCTION: Telemedicine programs using health technological innovation to remotely monitor the lifestyles of patients with type 2 diabetes (T2D) can improve glycaemic control and thus reduce the incidence of complications as well as management costs. In this context, an assessment was made of the 1-year and 2-year cost-effectiveness of the EDUC@DOM telemonitoring and tele-education program. METHODS: The EDUC@DOM study was a multicentre randomized controlled trial conducted between 2013 and 2017 that compared a telemonitoring group (TMG) to a control group (CG) merged with health insurance databases to extract economic data on resource consumption. Economic analysis was performed from the payer perspective, and direct costs and indirect costs were considered. The clinical outcome used was the intergroup change in glycated haemoglobin (HbA1c) levels from baseline. Missing economic data were imputed using multiple imputation, and fitted values from a generalized linear mixed model were used to calculate the incremental cost-effectiveness ratio (ICER). Bootstrapped 95% confidence ellipses were drawn in the cost-effectiveness plan. RESULTS: The main analysis included data from 256 patients: 126 in the TMG and 130 in the CG. Incremental costs over 1 and 2 years were equal to €2129 and €5101, respectively, in favour of the TMG. Once imputed and adjusted for confounding factors, the TMG trends to a 21% cost decrease over 1 and 2 years of follow-up (0.79 [0.58; 1.08], p = 0.1452 and 0.79 [0.61; 1.03], p = 0.0879, respectively). The EDUC@DOM program led to a €1334 cost saving and a 0.17 decrease in HbA1c over 1 year and a €3144 cost saving and a 0.14 decrease in HbA1c over 2 years. According to the confidence ellipse, EDUC@DOM was a cost-effective strategy. CONCLUSION: This study provides additional economic information on telemonitoring and tele-education programs to enhance their acceptance and promote their use. In the light of this work, the EDUC@DOM program is a cost-saving strategy in T2D management. TRIAL REGISTRATION: This trial was registered in the Clinical Trials Database on 27 September 2013 under no. NCT01955031 and bears ID-RCB no. 2013-A00391-44.

11.
Diabetes Obes Metab ; 24(5): 859-867, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34984786

RESUMEN

AIM: To assess the glucose control outcomes of the implantable Eversense real-time continuous glucose monitoring (CGM) system compared to self-monitoring of blood glucose or intermittently scanned CGM in patients with type 1 (T1D) or type 2 diabetes (T2D). PATIENTS AND METHODS: This was a randomized (2:1), prospective, national, multicentre study. All participants, aged >18 years and on multiple daily insulin injections or insulin pump treatment, had a sensor inserted, which was activated only in the "enabled" group. Included patients had T1D or T2D with a glycated haemoglobin (HbA1c) level > 8% (64 mmol/mol) (Cohort 1) or T1D with a time spent with glucose values below 70 mg/dL (3.8 mmol/l) (TBR<70 ) for >1.5 h/d during the previous 28 days (Cohort 2). The primary outcomes were HbA1c change at D180 (Cohort 1) or change in time spent with glucose values below 54 mg/dL (TBR<54 ) during the period of Day (D)90 to D120 (Cohort 2). A covariance model (analyses of covariance) was used for endpoint analyses. RESULTS: Overall, 149 patients were included in Cohort 1 and 90 in Cohort 2. In Cohort 1, the adjusted mean difference (enabled - control) in HbA1c at D180 was -0.1% (95% confidence interval [CI] -0.4; 0.1; P = 0.341). No significant difference in time with values in the range 70 to 180 mg/dL or time with values above range (>180 mg/dL) was observed. In Cohort 2, the mean adjusted difference in TBR<54 was -1.6% (95% CI -3.1; -0.1; P = 0.039) during D90 to D120 and remained at -2.6% (95% CI -4.5; -0.6; P = 0.011) during D150 to D180 (prespecified secondary outcome). The CGM system was found to be safe. CONCLUSION: This study shows that the Eversense CGM system can significantly decrease TBR<54 in patients with T1D prone to hypoglycaemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglucemia , Adolescente , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Francia/epidemiología , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Estudios Prospectivos
12.
J Matern Fetal Neonatal Med ; 35(25): 7992-8000, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34182866

RESUMEN

AIMS: To examine clinical parameters, glycemic control, folic acid supplementation, and the presence of other chronic diseases during early pregnancy in the EVOLVE study population (women with pre-existing diabetes treated with injectable glucose-lowering drugs). METHODS: Cross-sectional baseline evaluation of EVOLVE: an international, multicenter, non-interventional study investigating the safety of injectable glucose-lowering drugs in pregnant women with pre-existing type 1 (T1D) or type 2 diabetes (T2D). Data were collected at enrollment visit interviews before gestational week 16. RESULTS: In total, 2383 women from 17 mainly European countries were enrolled in the study: 2122 with T1D and 261 with T2D; mean age was 31 and 33 years, and duration of diabetes was 15 and 6 years, respectively. For women with T1D or T2D, 63% and 75%, respectively, received basal and rapid-acting insulin, 36% and 3% rapid-acting insulin only, 0.7% and 14.0% basal insulin only, 0.2% and 5.4% premix insulin, 0.0% and 1.2% injectable glucagon-like peptide-1 receptor agonist treatment without insulin. In women with T1D or T2D, respectively, during early pregnancy, 59% and 62% had HbA1c <7.0% (53 mmol/mol); 16% and 36% reported not taking folic acid before or during early pregnancy. Overall, >40% of women had ≥1 chronic concomitant condition (predominantly thyroid disease or hypertension). Retinopathy was the most commonly reported diabetic complication. The most commonly reported previous pregnancy complication was miscarriage. CONCLUSIONS: Baseline data from this large multinational population of women with pre-existing diabetes indicate that sub-optimal glycemic control, poor pregnancy planning, and chronic concomitant conditions were common in early pregnancy.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Embarazo en Diabéticas , Femenino , Humanos , Embarazo , Adulto , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 1/epidemiología , Hipoglucemiantes/uso terapéutico , Embarazo en Diabéticas/tratamiento farmacológico , Embarazo en Diabéticas/epidemiología , Glucosa , Mujeres Embarazadas , Estudios Transversales , Insulina/uso terapéutico , Insulina de Acción Corta/uso terapéutico , Ácido Fólico/uso terapéutico , Glucemia
13.
Clin Gastroenterol Hepatol ; 20(8): 1857-1866.e1, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33189854

RESUMEN

BACKGROUND & AIMS: Medico-economic data of patients suffering from chronic nausea and vomiting are lacking. In these patients, gastric electrical stimulation (GES) is an effective, but costly treatment. The aim of this study was to assess the efficacy, safety and medico-economic impact of Enterra therapy in patients with chronic medically refractory nausea and vomiting. METHODS: Data were collected prospectively from patients with medically refractory nausea and/or vomiting, implanted with an Enterra device and followed for two years. Gastrointestinal quality of life index (GIQLI) score, vomiting frequency, nutritional status and safety were evaluated. Direct and indirect expenditure data were prospectively collected in diaries. RESULTS: Complete clinical data were available for142 patients (60 diabetic, 82 non-diabetic) and medico-economic data were available for 96 patients (36 diabetic, 60 non-diabetic), 24 months after implantation. GIQLI score increased by 12.1 ± 25.0 points (p < .001), with a more significant improvement in non-diabetic than in diabetic patients (+15.8 ± 25.0 points, p < .001 versus 7.3 ± 24.5 points, p = .027, respectively). The proportion of patients vomiting less than once per month increased by 25.5% (p < .001). Hospitalisations, time off work and transport were the main sources of costs. Enterra therapy decreased mean overall healthcare costs from 8873 US$ to 5525 US$ /patient/year (p = .001), representing a saving of 3348 US$ per patient and per year. Savings were greater for diabetic patients (4096 US$ /patient/year) than for non-diabetic patients (2900 US$ /patient/year). CONCLUSIONS: Enterra therapy is an effective, safe and cost-effective option for patients with refractory nausea and vomiting. CLINICALTRIALS: gov Identifier: NCT00903799.


Asunto(s)
Terapia por Estimulación Eléctrica , Gastroparesia , Estimulación Eléctrica , Terapia por Estimulación Eléctrica/efectos adversos , Estrés Financiero , Vaciamiento Gástrico , Humanos , Náusea/etiología , Calidad de Vida , Resultado del Tratamiento , Vómitos/etiología , Vómitos/terapia
14.
Diabetes Care ; 44(9): 2069-2077, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34330786

RESUMEN

OBJECTIVE: To compare the risk of severe adverse pregnancy complications in women with preexisting diabetes. RESEARCH DESIGN AND METHODS: Multinational, prospective cohort study to assess the prevalence of newborns free from major congenital malformations or perinatal or neonatal death (primary end point) following treatment with insulin detemir (detemir) versus other basal insulins. RESULTS: Of 1,457 women included, 727 received detemir and 730 received other basal insulins. The prevalence of newborns free from major congenital malformations or perinatal or neonatal death was similar between detemir (97.0%) and other basal insulins (95.5%) (crude risk difference 0.015 [95% CI -0.01, 0.04]; adjusted risk difference -0.003 [95% CI -0.03, 0.03]). The crude prevalence of one or more congenital malformations (major plus minor) was 9.4% vs. 12.6%, with a similar risk difference before (-0.032 [95% CI -0.064, 0.000]) and after (-0.036 [95% CI -0.081, 0.009]) adjustment for confounders. Crude data showed lower maternal HbA1c during the first trimester (6.5% vs. 6.7% [48 vs. 50 mmol/mol]; estimated mean difference -0.181 [95% CI -0.300, -0.062]) and the second trimester (6.1% vs. 6.3% [43 vs. 45 mmol/mol]; -0.139 [95% CI -0.232, -0.046]) and a lower prevalence of major hypoglycemia (6.0% vs. 9.0%; risk difference -0.030 [95% CI -0.058, -0.002]), preeclampsia (6.4% vs. 10.0%; -0.036 [95% CI -0.064, -0.007]), and stillbirth (0.4% vs. 1.8%; -0.013 [95% CI -0.024, -0.002]) with detemir compared with other basal insulins. However, differences were not significant postadjustment. CONCLUSIONS: Insulin detemir was associated with a similar risk to other basal insulins of major congenital malformations, perinatal or neonatal death, hypoglycemia, preeclampsia, and stillbirth.


Asunto(s)
Diabetes Mellitus , Muerte Perinatal , Glucemia , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/efectos adversos , Recién Nacido , Insulina Detemir/efectos adversos , Insulina de Acción Prolongada , Embarazo , Mujeres Embarazadas , Estudios Prospectivos
15.
Diabetes Ther ; 12(7): 2059-2075, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34160791

RESUMEN

INTRODUCTION: Telemonitoring in type 2 diabetes (T2D) is mainly based on glucose monitoring. A new type of connected device which routinely gathers data on weight, physical activity and food intake could improve patients' diabetes control. The main aim of this study was to assess the efficacy of an at-home interventional programme incorporating such devices and lifestyle education software on diabetes control, i.e., change in HbA1c, compared to standard care. METHODS: This multicentre study randomly assigned 282 people with T2D to either a telemonitoring group (TMG) or a control group (CG) for a 1-year intervention period. While routine follow-up was maintained in the CG, TMG subjects were provided with interactive lifestyle educational software (with artificial intelligence algorithms) and connected objects (blood glucose meters, scales and actimeters) for use in their own homes and were remotely monitored by their diabetologists. Changes in HbA1c were compared between groups using a mixed linear model. RESULTS: The mean HbA1c dropped from 7.8 ± 0.8% (62 mmol/mol) to 7.4 ± 1.0% (57 mmol/mol) in the TMG and from 7.8 ± 0.8% (62 mmol/mol) to 7.6 ± 1.0% (60 mmol/mol) in the CG, resulting in an intergroup difference of - 0.16 (p = 0.06) in favour of TMG, after adjustment for confounding factors. Within TMG, the decrease in HbA1c was greater in frequent users: - 0.23% (p = 0.03) in the case of connections to telemonitoring synthesis above the median and - 0.21% (p = 0.05) in the case of connections to tele-education software above the median compared to the CG. Significant weight loss was observed in the TMG but only in women (p = 0.01). FINDINGS: The EDUC@DOM telemonitoring and tele-education device did not highlight a significant decrease in HbA1c levels compared to routine management although a slight, albeit significant improvement in glycaemic control was observed in the frequent user subgroup as well as significant weight loss but only in women. A high level of satisfaction with the connected device was recorded amongst all participants. TRIAL REGISTRATION: This trial was registered in the Clinical Trials Database on September 27, 2013, under no. NCT01955031 and bears ID-RCB number 2013-A00391-44.

16.
Diabetes Obes Metab ; 23(9): 2170-2176, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34009725

RESUMEN

A post hoc analysis of the Diabeloop WP7 multicentre, randomized controlled trial was performed to investigate the efficacy of the Diabeloop Generation-1 (DBLG1) closed-loop system in controlling the hypoglycaemia induced by physical activity (PA) in real-life conditions. Glycaemic outcomes were compared between days with and without PA in 56 patients with type 1 diabetes (T1D) using DBLG1 for 12 weeks. After the patient announces a PA, DBLG1 reduces insulin delivery and, if necessary, calculates the amount of preventive carbohydrates (CHO). Daily time spent in the interstitial glucose range less than 70 mg/dL was not significantly different between days with and without PA (2.0% ± 1.5% vs. 2.2% ± 1.1%), regardless of the intensity or duration of the PA. Preventive CHO intake recommended by the system was significantly higher in days with PA (41.1 ± 35.5 vs. 21.8 ± 28.5 g/day; P < .0001), and insulin delivery was significantly lower (31.5 ± 10.5 vs. 34.0 ± 10.5 U/day; P < .0001). The time spent in hyperglycaemia and the glycaemic variation coefficient increased significantly on days with PA. In real-life conditions, the use of DBLG1 avoids PA-induced hypoglycaemia. Insulin adjustments and preventive CHO recommendation may explain this therapeutic benefit.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Dieta , Ejercicio Físico , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
18.
Diabetes Technol Ther ; 22(12): 904-911, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32407148

RESUMEN

Background: The DIABEO® system (DS) is a telemedicine solution that combines a mobile app for patients with a web portal for health care providers. DS allows real-time monitoring of basal-bolus insulin therapy as well as therapeutic decision-making, integrating both basal and bolus dose calculation. Real-life studies have shown a very low rate of use of mobile health applications by patients. Therefore, we conducted a large randomized controlled trial study to investigate the efficacy of DS in conditions close to real life (TELESAGE study). Methods: TELESAGE was a multicenter, randomized, open study with three parallel arms: arm 1 (standard care), arm 2 (DIABEO alone), and arm 3 (DIABEO+telemonitoring by trained nurses). The primary outcome assessed the reduction in HbA1c levels after a 12-month follow-up. Results: Six hundred sixty-five patients were included in the study. Participants who used DIABEO once or more times a day (DIABEO users) showed a significant and meaningful reduction of HbA1c versus standard care after a 12-month follow-up: mean difference -0.41% for arm 2-arm 1 (P = 0.001) and -0.51% for arm 3-arm 1 (P ≤ 0.001). DIABEO users included 25.1% of participants in arm 2 and 37.6% in arm 3. In the intention-to-treat population, HbA1c changes and incidence of hypoglycemia were comparable between arms. Conclusions: A clinical and statistically significant reduction in HbA1c levels was found in those patients who used DIABEO at least once a day.


Asunto(s)
Glucemia/análisis , Diabetes Mellitus Tipo 2 , Insulina , Aplicaciones Móviles , Adulto , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Internet , Masculino , Persona de Mediana Edad , Telemetría
19.
Diabetes Obes Metab ; 22(3): 324-334, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31621186

RESUMEN

AIMS: To compare closed-loop (CL) and open-loop (OL) systems for glycaemic control in patients with type 1 diabetes (T1D) exposed to real-life challenging situations (gastronomic dinners or sustained physical exercise). METHODS: Thirty-eight adult patients with T1D were included in a three-armed randomized pilot trial (Diabeloop WP6.2 trial) comparing glucose control using a CL system with use of an OL device during two crossover 72-hour periods in one of the three following situations: large (gastronomic) dinners; sustained and repeated bouts of physical exercise (with uncontrolled food intake); or control (rest conditions). Outcomes included time in spent in the glucose ranges of 4.4-7.8 mmol/L and 3.9-10.0 mmol/L, and time in hypo- and hyperglycaemia. RESULTS: Time spent overnight in the tight range of 4.4 to 7.8 mmol/L was longer with CL (mean values: 63.2% vs 40.9% with OL; P ≤ .0001). Time spent during the day in the range of 3.9 to 10.0 mmol/L was also longer with CL (79.4% vs 64.1% with OL; P ≤ .0001). Participants using the CL system spent less time during the day with hyperglycaemic excursions (glucose >10.0 mmol/L) compared to those using an OL system (17.9% vs 31.9%; P ≤ .0001), and the proportions of time spent during the day with hyperglycaemic excursions of those using the CL system in the gastronomic dinner and physical exercise subgroups were of similar magnitude to those in the control subgroup (18.1 ± 6.3%, 17.2 ± 8.1% and 18.4 ± 12.5%, respectively). Finally, times spent in hypoglycaemia were short and not significantly different among the groups. CONCLUSIONS: The Diabeloop CL system is superior to OL devices in reducing hyperglycaemic excursions in patients with T1D exposed to gastronomic dinners, or exposed to physical exercise followed by uncontrolled food and carbohydrate intake.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Ejercicio Físico , Control Glucémico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Comidas
20.
Diabetes Ther ; 11(1): 279-291, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31833041

RESUMEN

INTRODUCTION: The impact of flash glucose monitoring technology on HbA1c in type 2 diabetes managed by basal bolus insulin is uncertain. Three parallel European retrospective non-interventional chart review studies collected data reported in medical records. Each country's study aim was to determine the effectiveness of the device on HbA1c when used by their population for 3-6 months as their standard of care for management of glycaemia in a real-world setting. METHODS: Medical records were eligible for adult patients with type 2 diabetes, on a basal bolus insulin regimen for 1 year or more, device use for 3 months or more before the start of the study, an HbA1c concentration up to 3 months prior to starting device use (patients were using blood glucose monitoring for self-management) between 64 and 108 mmol/mol (8.0-12.0%) plus an HbA1c determination 3-6 months after commencing flash glucose monitoring use. RESULTS: Records were analysed from 18 medical centres in Austria (n = 92), France (n = 88) and Germany (n = 183). Baseline HbA1c results, recorded up to 90 days before the start of device use, were comparable across the three countries and were reduced significantly by 9.6 ± 8.8 mmol/mol mean ± SD (Austria [0.9 ± 0.8%], p < 0.0001), 8.9 ± 12.5 mmol/mol (France [0.8% ± 1.1], p < 0.0001) and 10.1 ± 12.2 mmol/mol (Germany [0.9% ± 1.1], p < 0.0001). No significant differences were detected between age group, sex, BMI or duration of insulin use. CONCLUSIONS: Three European real-world, chart review studies in people with type 2 diabetes managed using basal bolus insulin therapy each concluded that HbA1c was significantly reduced after changing to use of flash glucose monitoring for 3-6 months in a real-world setting.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...