Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Chem Soc ; 135(11): 4191-4, 2013 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-23477541

RESUMEN

A new homogeneous chemiluminescent immunoassay method featuring the use of specific binding members separately labeled with an acridan-based chemiluminescent compound and a peroxidase is reported. Formation of an immunocomplex brings the chemiluminescent compound and the peroxidase into close proximity. Without any separation steps, a chemiluminescent signal is generated upon addition of a trigger solution, and the intensity is directly correlated to the quantity of the analyte.


Asunto(s)
Acridinas/química , Inmunoensayo/métodos , Sustancias Luminiscentes/química , Mediciones Luminiscentes/métodos , Animales , Anticuerpos Inmovilizados/química , AMP Cíclico/análisis , Peroxidasa de Rábano Silvestre/análisis , Humanos , Interleucina-8/análisis , Ratones , Antígeno Prostático Específico/análisis , Ratas , Ovinos
2.
J Immunol Methods ; 293(1-2): 97-106, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15541280

RESUMEN

E. coli O157:H7 is a pathogenic microorganism that has been implicated in numerous cases of foodborne illnesses. A variety of rapid methods exist that show promise for the presumptive detection of this pathogen without the immediate need for incubating test samples for hours to days in microbial enrichment and culture media. In recent years, highly sensitive chemiluminescence has become a more affordable and portable detection method. Chemiluminescent detection has been coupled with the selectivity of antibodies, magnetic microparticle separation/isolation, and enzymatic signal amplification in order to develop a rapid method, termed enzyme-linked immunomagnetic chemiluminescence (ELIMCL). This work presents the application of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline with a detection limit of 7.6 x 10(3) for live cells in approx. 75 min assay time. The blocking agent casein and the surfactant Tween 20 were used to lower background luminescence and thus maximize signal-to-noise ratios. After 5.5 h of enrichment culture, ELIMCL was demonstrated to detect E. coli O157:H7 inoculated in ground beef at 10 CFU/g in a total assay time of about 7 h.


Asunto(s)
Escherichia coli O157/aislamiento & purificación , Separación Inmunomagnética , Mediciones Luminiscentes , Ensayo de Inmunoadsorción Enzimática , Escherichia coli O157/inmunología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...