Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Heart J Cardiovasc Imaging ; 24(12): 1583-1592, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37463125

RESUMEN

AIMS: Speckle-tracking echocardiography (STE) strain imaging has been a major advancement in myocardial function quantification. We aimed to explore current worldwide clinical application of STE. METHODS AND RESULTS: Access, feasibility, access, and clinical implementation of STE were investigated with a worldwide open-access online survey of the European Association of Cardiovascular Imaging. Participants (429 respondents and 77 countries) from tertiary centres (46%), private clinics, or public hospitals (54%) using different vendors for data acquisition and analysis were represented. Despite almost universal access (98%) to STE, only 39% of the participants performed and reported STE results frequently (>50%). Incomplete training and time constraints were the main reasons for not using STE more regularly. STE was mainly used to assess the LV (99%) and less frequently the right ventricular (57%) and the left atrial (46%) function. Cardiotoxicity (88%) and cardiac amyloidosis (87%) were the most frequent reasons for the clinical use of LV STE. Left atrial STE was used most frequently for the diagnosis of diastolic dysfunction and right ventricular STE for the assessment of right ventricle (RV) function in pulmonary hypertension (51%). Frequency of STE use, adherence to optimal techniques, and clinical appropriateness of STE differed according to training experience and across vendors. Key suggestions outlined by respondents to increase the clinical use of STE included improved reproducibility (48%) and standardization of strain values across vendors (42%). CONCLUSION: Although STE is now readily available, it is underutilized in the majority of centres. Structured training, improved reproducibility, and inter-vendor standardization may increase its uptake.


Asunto(s)
Fibrilación Atrial , Humanos , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Atrios Cardíacos , Función Ventricular Izquierda
2.
Echocardiography ; 40(8): 775-783, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37351556

RESUMEN

AIM: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. METHODS: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). RESULTS: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively. CONCLUSION: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.


Asunto(s)
Fibrilación Atrial , Humanos , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Sistema de Registros
4.
Int J Cardiol ; 370: 178-185, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36273665

RESUMEN

BACKGROUND: Congenital Heart Disease (CHD) predisposes to Infective Endocarditis (IE), but data about characterization and prognosis of IE in CHD patients is scarce. METHODS: The ESC-EORP-EURO-ENDO study is a prospective international study in IE patients (n = 3111). In this pre-specified analysis, adult CHD patients (n = 365, 11.7%) are described and compared with patients without CHD (n = 2746) in terms of baseline characteristics and mortality. RESULTS: CHD patients (73% men, age 44.8 ± 16.6 years) were younger and had fewer comorbidities. Of the CHD patients, 14% had a dental procedure before hospitalization versus 7% in non-CHD patients (p < 0.001) and more often had positive blood cultures for Streptococcus viridans (16.4% vs 8.8%, p < 0.001). As in non-CHD patients, IE most often affected the left-sided valves. For CHD patients, in-hospital mortality was 9.0% vs 18.1% in non-CHD patients (p < 0.001), and also, during the entire follow-up of 700 days, survival was more favorable (log-rank p < 0.0001), even after adjustment for age, gender and major comorbidities (Hazard Ratio (HR) 0.68; 95%CI 0.50-0.92). Within the CHD population, multivariable Cox regression revealed the following effects (HR and [95% CI]) on mortality: fistula (HR 6.97 [3.36-14.47]), cerebral embolus (HR 4.64 [2.08-10.35]), renal insufficiency (HR 3.44 [1.48-8.02]), Staphylococcus aureus as causative agent (HR 2.06 [1.11-3.81]) and failure to undertake surgery when indicated (HR 5.93 [3.15-11.18]). CONCLUSIONS: CHD patients with IE have a better outcome in terms of all-cause mortality. The observed high incidence of dental procedures prior to IE warrants further studies about the current use, need and efficacy of antibiotic prophylaxis in CHD patients.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Cardiopatías Congénitas , Masculino , Humanos , Adulto , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Factores de Riesgo , Endocarditis/diagnóstico , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/complicaciones , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/epidemiología , Estudios Retrospectivos
5.
J Clin Med ; 11(23)2022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-36498676

RESUMEN

Despite advances in medical therapy and mechanical circulatory support (MCS), heart transplant (HT) remains the gold standard therapy for end-stage heart failure. Patients in cardiogenic shock require prompt intervention to reverse hypoperfusion and end-organ damage. When medical therapy becomes insufficient, MCS should be considered. Historically, it has been reported that critically ill patients bridged with veno-arterial extracorporeal membrane oxygenation (VA-ECMO) directly to HT have worse outcomes. However, when the heart allocation system gives the highest priority to patients on VA-ECMO support, those patients have a higher incidence of HT and a lower incidence of death or removal from the transplant list. Moreover, patients with a short waiting time on VA-ECMO have a similar hazard of mortality to non-ECMO patients. According to the reported data, bridging with VA-ECMO directly to HT may be a solution in the selection of critically ill patients when the anticipated waiting list time is short. However, when a prolonged waiting time is expected, more durable MCS should be considered. Regardless of the favorable results of the direct bridging to HT with ECMO in selected patients, the superiority of this strategy compared to the bridge-to-bridge strategy (ECMO to durable MCS) has not been established and further studies are mandatory in order to clarify this issue.

6.
Coll Antropol ; 37(4): 1357-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24611357

RESUMEN

We describe a case report of a patient with cardiac arrest and Ebstein's anomaly. This case report shows us necessity for arrhythmia evaluation and sudden death risk stratification even in asymptomatic patients. Prophylactic ICD implantation in this patient population is limited to observational studies and the selection of patients is impeded by the absence of randomized trials and weak predictors.


Asunto(s)
Anomalía de Ebstein/complicaciones , Paro Cardíaco/complicaciones , Adulto , Anomalía de Ebstein/diagnóstico por imagen , Ecocardiografía , Femenino , Paro Cardíaco/diagnóstico por imagen , Humanos
8.
Regul Pept ; 156(1-3): 83-9, 2009 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-19465062

RESUMEN

Pentadecapeptide BPC 157 (GEPPPGKPADDAGLV, MW 1419) reversed congestive heart failure and various arrhythmias, influenced the NO-system and showed no proarrhythmic effect. In therapy analogy, we challenged rats with digitalis, to show attenuation by BPC 157 and the relation between the NO-system and digitalis toxicity. (i). BPC 157 prophylactic effect. Development of cumulative intravenous digitalis toxicity, BPC 157 (50 microg, 10 microg, 10 ng/kg applied intravenously immediately before a methyldigoxin increment regimen (2.0/1.5/1.5/1.0 mg/kg at 15 min-intervals, total dose 6.0 mg/kg/45 min)) reduced the number of ventricular premature beats, prolonged the time before onset of ventricular tachycardia, reduced ventricular tachycardia and AV-block duration (microg-regimes) or reduced mainly the AV-block duration (ng-regimen). (ii). BPC 157 therapy. Advanced methyldigoxin toxicity (6.0 mg/kg i.v. bolus). BPC 157 applied at the 20th second of the grade 3 AV-block shortened AV-blocks, mitigated a further digitalis toxicity course. Ventricular tachycardias were either avoided (50 microg), or markedly reduced (10 microg, 10 ng). Fatal outcome was either avoided (50 microg), reduced (10 microg), or only delayed (10 ng) (iii) BPC 157, L-NAME, l-arginine, L-NAME+l-arginine application. L-NAME-application (5 mg/kg i.p.) aggravated methyldigoxin-arrhythmias. l-arginine (200 mg/kg i.p.) alone had no effect but blunted L-NAME-exaggeration (L-NAME+l-arginine). In this respect, BPC 157 (50 microg/kg i.p.) was prophylactically and therapeutically more effective: the antagonism of L-NAME with BPC 157 produced an effect similar to BPC 157 alone. In conclusion, digitalis-induced arrhythmias in rats could be prevented and counteracted by pentadecapeptide BPC 157, mainly through an interaction with the NO-system.


Asunto(s)
Antiarrítmicos/farmacología , Arritmias Cardíacas/inducido químicamente , Frecuencia Cardíaca/efectos de los fármacos , Medigoxina/farmacología , Óxido Nítrico/metabolismo , Fragmentos de Péptidos/farmacología , Proteínas/farmacología , Animales , Antiulcerosos/farmacología , Arginina/farmacología , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/prevención & control , Masculino , NG-Nitroarginina Metil Éster/farmacología , Ratas , Ratas Wistar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...