Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
R Soc Open Sci ; 9(5): 212022, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35592762

RESUMEN

There is ongoing and rapid advancement in approaches to modelling the fate of exhaled particles in different environments relevant to disease transmission. It is important that models are verified by comparison with each other using a common set of input parameters to ensure that model differences can be interpreted in terms of model physics rather than unspecified differences in model input parameters. In this paper, we define parameters necessary for such benchmarking of models of airborne particles exhaled by humans and transported in the environment during breathing and speaking.

2.
Curr Res Food Sci ; 3: 304-313, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33336192

RESUMEN

The perception of some food attributes is related to mechanical stimulation and friction experienced in the tongue-palate contact during mastication. This paper reports a new bench test to measure friction in the simulated tongue-palate contact. The test consists of a flat PDMS disk, representing the tongue loaded and reciprocating against a stationary lower glass surface representing the palate. The test was applied to molten chocolate samples with and without artificial saliva. Friction was measured over the first few rubbing cycles, simulating mechanical degradation of chocolate in the tongue-palate region. The effects of chocolate composition (cocoa solids content ranging between 28 â€‹wt% and 85 â€‹wt%) and structure (micro-aeration/non-aeration 0-15 â€‹vol%) were studied. The bench test clearly differentiates between the various chocolate samples. The coefficient of friction increases with cocoa solids percentage and decreases with increasing micro-aeration level. The presence of artificial saliva in the contact reduced the friction for all chocolate samples, however the relative ranking remained the same.

3.
Appl Opt ; 54(14): 4566-79, 2015 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-25967518

RESUMEN

Schlieren [Schlieren and Shadowgraphy Techniques (McGraw-Hill, 2001); Optics of Flames (Butterworths, 1963)] is a non-intrusive technique that can be used to detect density variations in a medium, and thus, under constant pressure and mixture concentration conditions, measure whole-field temperature distributions. The objective of the current work was to design a schlieren system to measure line-of-sight (LOS)-averaged temperature distribution with the final aim to determine the temperature distribution inside the cylinder of internal combustion (IC) engines. In a preliminary step, we assess theoretically the errors arising from the data reduction used to determine temperature from a schlieren measurement and find that the total error, random and systematic, is less than 3% for typical conditions encountered in the present experiments. A Z-type, curved-mirror schlieren system was used to measure the temperature distribution from a hot air jet in an open air environment in order to evaluate the method. Using the Abel transform, the radial distribution of the temperature was reconstructed from the LOS measurements. There was good agreement in the peak temperature between the reconstructed schlieren and thermocouple measurements. Experiments were then conducted in a four-stroke, single-cylinder, optical spark ignition engine with a four-valve, pentroof-type cylinder head to measure the temperature distribution of the reaction zone of an iso-octane-air mixture. The engine optical windows were designed to produce parallel rays and allow accurate application of the technique. The feasibility of the method to measure temperature distributions in IC engines was evaluated with simulations of the deflection angle combined with equilibrium chemistry calculations that estimated the temperature of the reaction zone at the position of maximum ray deflection as recorded in a schlieren image. Further simulations showed that the effects of exhaust gas recirculation and air-to-fuel ratio on the schlieren images were minimal under engine conditions compared to the temperature effect. At 20 crank angle degrees before top dead center (i.e., 20 crank angle degrees after ignition timing), the measured temperature of the flame front was in agreement with the simulations (730-1320 K depending on the shape of the flame front). Furthermore, the schlieren images identified the presence of hot gases ahead of the reaction zone due to diffusion and showed that there were no hot spots in the unburned mixture.

4.
Opt Lett ; 37(11): 2040-2, 2012 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-22660114

RESUMEN

The laser measurement technique based on the ratio between the laser induced fluorescence (LIF) and the scattered light (Mie) intensities of droplets is presently limited to the evaluation of the Sauter mean diameter of the droplets. The important measurement of the droplet size spread is currently missing. An extension of the LIF/Mie technique for the measurement of droplet size spread is proposed here and is evaluated numerically. The method is based on the imperfect relationships between the scattered light intensity and the droplet surface area or the fluorescent light intensity and the droplet volume, which convey additional information that can be used to evaluate the droplet size spread.

5.
Appl Opt ; 50(20): 3622-37, 2011 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-21743575

RESUMEN

The droplet sizing accuracy of the laser technique, based on the ratio of laser-induced fluorescence (LIF) and scattered light (Mie) intensities from droplets, is examined. We develop an analytical model of the ratio of fluorescent to scattered light intensities of droplets, which shows that the LIF/Mie technique is susceptible to sizing errors that depend on the mean droplet size and the spread of the droplet size distribution. The sizing uncertainty due to the oscillations of the scattered light intensity as a function of droplet size is first quantified. Then, a new data processing method is proposed that can improve the sizing uncertainty of the technique for the sprays that were examined in this study by more than 5% by accounting for the size spread of the measured droplets, while improvements of 25% are possible when accounting for the mean droplet size. The sizing accuracy of the technique is evaluated in terms of the refractive index of liquid, scattering angle, and dye concentration in the liquid. It is found that the proposed approach leads to sizing uncertainty of less than 14% when combined with light collection at forward scattering angles close to 60° and the lowest fluorescent dye concentration in the liquid for all refractive indices.


Asunto(s)
Microscopía Fluorescente/métodos , Refractometría/instrumentación , Algoritmos , Calibración , Diseño de Equipo , Colorantes Fluorescentes/farmacología , Luz , Modelos Estadísticos , Oscilometría/métodos , Fotometría/métodos , Reproducibilidad de los Resultados , Dispersión de Radiación
6.
Nanoscale Res Lett ; 6(1): 391, 2011 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-21711932

RESUMEN

This paper contains the results of a concise statistical review analysis of a large amount of publications regarding the anomalous heat transfer modes of nanofluids. The application of nanofluids as coolants is a novel practise with no established physical foundations explaining the observed anomalous heat transfer. As a consequence, traditional methods of performing a literature review may not be adequate in presenting objectively the results representing the bulk of the available literature. The current literature review analysis aims to resolve the problems faced by researchers in the past by employing an unbiased statistical analysis to present and reveal the current trends and general belief of the scientific community regarding the anomalous heat transfer modes of nanofluids. The thermal performance analysis indicated that statistically there exists a variable enhancement for conduction, convection/mixed heat transfer, pool boiling heat transfer and critical heat flux modes. The most popular proposed mechanisms in the literature to explain heat transfer in nanofluids are revealed, as well as possible trends between nanofluid properties and thermal performance. The review also suggests future experimentation to provide more conclusive answers to the control mechanisms and influential parameters of heat transfer in nanofluids.

7.
Appl Opt ; 50(9): 1197-209, 2011 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-21460991

RESUMEN

The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60° rather than the commonly used angle of 90°. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90°) and for droplets with refractive indices around 1.4.

8.
Phys Rev Lett ; 97(14): 144501, 2006 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-17155255

RESUMEN

By applying fractal electromagnetic force fields on a thin layer of brine, we generate steady quasi-two-dimensional laminar flows with multiscale stagnation point topology. This topology is shown to control the evolution of pair separation (Delta) statistics by imposing a turbulentlike locality based on the sizes and strain rates of hyperbolic stagnation points when the flows are fast enough, in which case Delta(2) approximately t(gamma) is a good approximation with gamma close to 3. Spatially multiscale laminar flows with turbulentlike spectral and stirring properties are a new concept with potential applications in efficient and microfluidic mixing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...