Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(5): 984-993, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38486082

RESUMEN

INTRODUCTION: Little is known about very early atrial fibrillation (AF) ablation after first AF detection. METHODS: We evaluated patients with AF ablation <4 months from newly diagnosed paroxysmal AF (NEWPaAF) and newly diagnosed persistent AF (NEWPeAF). We compared the two patient populations and compared ablation outcomes to those undergoing later ablation. RESULTS: Ablation was done <4 months from AF diagnosis in 353 patients (135 = paroxysmal, 218 = persistent). Early ablation outcome was best for NEWPaAF versus NEWPeAF for initial (p = 0.030) but not final (p = 0.102) ablation. Despite recent AF diagnosis in both groups, they were clinically quite different. NEWPaAF patients were younger (64.3 ± 13.0 vs. 67.3 ± 10.9, p = 0.0020), failed fewer drugs (0.39 vs. 0.60, p = 0.007), had smaller LA size (4.12 ± 0.58 vs. 4.48 ± 0.59 cm, p < 0.0001), lower BMI (28.8 ± 5.0 vs. 30.3 ± 6.0, p = 0.016), and less CAD (3.7% vs. 11.5%, p = 0.007), cardiomyopathies (2.2% vs. 22.9%, p = 0.0001), hypertension (46.7% vs. 67.4%, p < 0.0001), diabetes (8.1% vs. 17.4%, p = 0.011) and sleep apnea (20.0% vs. 30.3%, p = 0.031). For NEWPaAF, early ablation AF-free outcome was no better than later ablation (p = 0.314). For NEWPeAF, AF-free outcomes were better for early ablation than later ablation (p < 0.0001). Delaying ablation allowed more strokes/TIAs in both AF types (paroxysmal p = 0.014, persistent p < 0.0001). CONCLUSIONS: Patients presenting for early ablation after newly diagnosed persistent AF have more pre-existing comorbidities and worse initial ablation outcomes than patients with NEWPaAF. For NEWPaAF, there was no advantage to early ablation, as long as the AF remained paroxysmal. For NEWPeAF, early ablation gave better outcomes than later ablation and they should undergo early ablation. For both AF types, waiting was associated with more neurologic events, suggesting all patients should consider earlier ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Ablación por Catéter/efectos adversos , Femenino , Persona de Mediana Edad , Factores de Tiempo , Anciano , Factores de Riesgo , Resultado del Tratamiento , Frecuencia Cardíaca , Tiempo de Tratamiento , Potenciales de Acción , Estudios Retrospectivos
2.
J Interv Card Electrophysiol ; 52(1): 1-8, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29460232

RESUMEN

PURPOSE: The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. METHODS: We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. RESULTS: A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. CONCLUSIONS: Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Tempo Operativo , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Ablación por Catéter/métodos , Estudios de Cohortes , Electrocardiografía/métodos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...