Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 125(15): 155003, 2020 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-33095614

RESUMEN

The implosion efficiency in inertial confinement fusion depends on the degree of stagnated fuel compression, density uniformity, sphericity, and minimum residual kinetic energy achieved. Compton scattering-mediated 50-200 keV x-ray radiographs of indirect-drive cryogenic implosions at the National Ignition Facility capture the dynamic evolution of the fuel as it goes through peak compression, revealing low-mode 3D nonuniformities and thicker fuel with lower peak density than simulated. By differencing two radiographs taken at different times during the same implosion, we also measure the residual kinetic energy not transferred to the hot spot and quantify its impact on the implosion performance.

2.
Rev Sci Instrum ; 89(10): 10G109, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399958

RESUMEN

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector's output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector's response to a uniform illumination. We also demonstrate that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative approach to the usual method employed to measure their modulation transfer functions.

3.
Rev Sci Instrum ; 83(10): 10E118, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126940

RESUMEN

Gated and streaked x-ray detectors generally require corrections in order to counteract instrumental effects in the data. The method of correcting for gain variations in gated cameras fielded at National Ignition Facility (NIF) is described. Four techniques for characterizing the gated x-ray detectors are described. The current principal method of characterizing x-ray instruments is the production of controlled x-ray emission by laser-generated plasmas as a dedicated shot at the NIF. A recently commissioned pulsed x-ray source has the potential to replace the other characterization systems. This x-ray source features a pulsed power source consisting of a Marx generator, capacitor bank that is charged in series and discharged in parallel, producing up to 300 kV. The pulsed x-ray source initially suffered from a large jitter (∼60 ns), but the recent addition of a pulsed laser to trigger the spark gap has reduced the jitter to ∼5 ns. Initial results show that this tool is a promising alternative to the other flat fielding techniques.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...