1.
Biosens Bioelectron ; 150: 111837, 2020 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-31735622

RESUMEN

This is the first report on the fabrication, characterisation and application of an electrochemical (bio)sensor system for the simultaneous measurement of skatole and androstenone. A biosensor for androstenone was fabricated using a Meldola's Blue modified SPCE (MB-SPCE) by depositing NADH and the enzyme 3α-hydroxysteroid dehydrogenase onto the MB-SPCE surface; samples of adipose tissue were analysed using the biosensors in conjunction with chronoamperometry. Cyclic voltammetry was used to investigate the electrochemical behaviour of skatole at a screen-printed carbon electrode (SPCE vs. Ag/AgCl). An oxidation peak was observed around +0.55 V (vs. Ag/AgCl) and differential pulse voltammetry was applied for quantification of skatole in adipose tissue (in-situ). Quantitative analysis was achieved using calibration plots obtained from fortified meat samples. The concentrations obtained by the electrochemical and gas chromatographic (GC) methods demonstrated a good positive correlation. The (bio)sensor system completed both measurements within 60 s, as compared to several hours for GC, and at a considerably reduced cost and complexity. Consequently, the novel (bio)sensor system should have applications for analysis of carcasses on the abattoir processing line.


Asunto(s)
Androsterona/aislamiento & purificación , Técnicas Biosensibles , Carne/análisis , Escatol/aislamiento & purificación , Tejido Adiposo/química , Androsterona/química , Animales , Humanos , Masculino , Escatol/química , Porcinos
2.
Talanta ; 181: 13-18, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29426491

RESUMEN

This paper describes the development of a novel electrochemical assay for the measurement of water-soluble vitamins in food and pharmaceutical products. The optimum conditions for the determination of vitamin B1 (thiamine), B2 (riboflavin) and B6 (pyridoxine) in phosphate buffer were established using cyclic voltammetry in conjunction with screen printed carbon electrodes (SPCEs). The optimum current response for all three vitamins was achieved in 0.1M phosphate buffer pH 11 using an initial potential of -1.0V. Using square wave voltammetry, the linear ranges for thiamine, riboflavin, and pyridoxine were found to be: 15-110µg/ml, 0.1-20µg/ml, and 2-80µg/ml respectively. The application of the method to a commercial food product yielded a recovery of 95.78% for riboflavin, with a coefficient of variation (CV) of 3.38% (n = 5). The method was also applied to a multi-vitamin supplement for the simultaneous determination of thiamine, riboflavin and pyridoxine. In both cases only simple dilution with buffer followed by centrifugation was required prior to analysis. The resulting square wave voltammetric signals were completely resolved with Ep values of -0.7V, +0.2V, and +0.6V respectively. The recoveries determined for the vitamin B complex in a commercial supplement product were found to be 110%, 114%, and 112% respectively (CV = 7.14%, 6.28%. 5.66% respectively, n = 5).


Asunto(s)
Técnicas Biosensibles/métodos , Carbono/química , Suplementos Dietéticos/análisis , Técnicas Electroquímicas/métodos , Análisis de los Alimentos/métodos , Complejo Vitamínico B/análisis , Reproducibilidad de los Resultados , Riboflavina/análisis , Tiamina/análisis , Vitamina B 6/análisis
3.
Methods Mol Biol ; 1572: 1-12, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28299677

RESUMEN

A reagentless biosensor has been successfully developed to measure glutamate in food and clinical samples. The enzyme, glutamate dehydrogenase (GLDH) and the cofactor, nicotinamide adenine dinucleotide (NAD+) are fully integrated onto the surface of a Meldola's Blue screen-printed carbon electrode (MB-SPCE). The biological components are immobilized by utilizing unpurified multi-walled carbon nanotubes (MWCNT's) mixed with the biopolymer chitosan (CHIT), which are drop-coated onto the surface of the MB-SPCE in a layer-by-layer fashion. Meldola's Blue mediator is also incorporated into the biosensor cocktail in order to increase and facilitate electron shuttling between the reaction layers and the surface of the electrode. The loadings of each component are optimized by using amperometry in stirred solution at a low fixed potential of +0.1 V. The optimum temperature and pH are also determined using this technique. Quantification of glutamate in real samples is performed using the method of standard addition. The method of standard addition involves the addition of a sample containing an unknown concentration of glutamate, followed by additions of known concentrations of glutamate to a buffered solution in the cell. The currents generated by each addition are then plotted and the resulting line is extrapolated in order to determine the concentration of glutamate in the sample (Pemberton et al., Biosens Bioelectron 24:1246-1252, 2009). This layer-by-layer approach holds promise as a generic platform for the fabrication of reagentless biosensors.


Asunto(s)
Biomarcadores/análisis , Técnicas Biosensibles/métodos , Análisis de los Alimentos/métodos , Ácido Glutámico/análisis , Ácido Glutámico/sangre , Técnicas Biosensibles/instrumentación , Electrodos , Enzimas Inmovilizadas , Diseño de Equipo , Análisis de los Alimentos/instrumentación , Glutamato Deshidrogenasa/química , Humanos , Hidrodinámica , Nanotubos de Carbono , Oxazinas
4.
Anal Chim Acta ; 933: 82-8, 2016 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-27497000

RESUMEN

A reagentless glutamate biosensor was applied to the determination of glutamate released from liver hepatocellular carcinoma cells (HepG2) in response to toxic challenge from various concentrations of paracetamol. A screen printed carbon electrode (SPCE) containing the electrocatalyst Meldola's Blue (MB-SPCE) served as the electron mediator for the oxidation of NADH. A mixture of the enzyme glutamate dehydrogenase (GLDH), cofactor nicotinamide adenine dinucleotide (NAD(+)) and the biopolymer chitosan (CHIT) were drop-coated onto the surface of the transducer (MB-SPCE) in a simple one step fabrication process. The reagentless biosensor was used with amperometry in stirred solution at an applied potential of +0.1 V (vs. Ag/AgCl). All experiments were carried out at the following conditions: pH 7, temperature 37 °C, atmosphere 5% CO2. The linear range of the device was found to be 25-125 µM in phosphate buffer (75 mM, containing 0.05 M NaCl) and 25-150 µM in cell culture medium. The limits of detection (LOD) were found to be 1.2 µM and 4.2 µM based on three times signal to noise, using PBS and culture medium respectively. The sensitivity was calculated to be 106 nA µM(-1) cm(-2) and 210 nA µM(-1) cm(-2) in PBS and cell medium respectively. The response time was ∼60 s in an agitated solution. HepG2 cells were exposed to various concentrations of paracetamol (1 mM, 5 mM and 10 mM) in order to investigate the drug-induced release of glutamate into the culture medium in real time. Two toxicity studies were investigated using different methods of exposure and analysis. The first method consisted of a single measurement of the glutamate concentration, using the method of standard addition, after 24 h incubation. The concentrations of glutamate were found to be 52 µM, 93 µM and 177 µM, released on exposure to 1 mM, 5 mM and 10 mM paracetamol respectively. The second method involved the continuous monitoring of glutamate released from HepG2 cells upon exposure to paracetamol over 8 h. The concentrations of glutamate released in the presence of 1 mM, 5 mM and 10 mM paracetamol, increased in proportion to the drug concentration, ie: 16 µM, 28 µM and 62 µM respectively. This result demonstrates the feasibility of using this approach to monitor early metabolic changes after exposure to a model toxic compound.


Asunto(s)
Acetaminofén/toxicidad , Técnicas Biosensibles , Ácido Glutámico/análisis , Proliferación Celular/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Ácido Glutámico/metabolismo , Células Hep G2 , Humanos , Factores de Tiempo , Células Tumorales Cultivadas
5.
Biosens Bioelectron ; 42: 668-77, 2013 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-23265827

RESUMEN

A water-based carbon screen-printing ink formulation, containing the redox mediator cobalt phthalocyanine (CoPC) and the enzyme glucose oxidase (GOx), was investigated for its suitability to fabricate glucose microbiosensors in a 96-well microplate format: (1) the biosensor ink was dip-coated onto a platinum (Pt) wire electrode, leading to satisfactory amperometric performance; (2) the ink was deposited onto the surface of a series of Pt microelectrodes (10-500 µm diameter) fabricated on a silicon substrate using MEMS (microelectromechanical systems) microfabrication techniques: capillary deposition proved to be successful; a Pt microdisc electrode of ≥100 µm was required for optimum biosensor performance; (3) MEMS processing was used to fabricate suitably sized metal (Pt) tracks and pads onto a silicon 96 well format base chip, and the glucose biosensor ink was screen-printed onto these pads to create glucose microbiosensors. When formed into microwells, using a 340 µl volume of buffer, the microbiosensors produced steady-state amperometric responses which showed linearity up to 5 mM glucose (CV=6% for n=5 biosensors). When coated, using an optimised protocol, with collagen in order to aid cell adhesion, the biosensors continued to show satisfactory performance in culture medium (linear range to 2 mM, dynamic range to 7 mM, CV=5.7% for n=4 biosensors). Finally, the operation of these collagen-coated microbiosensors, in 5-well 96-well format microwells, was tested using a 5-channel multipotentiostat. A relationship between amperometric response due to glucose, and cell number in the microwells, was observed. These results indicate that microphotolithography and screen-printing techniques can be combined successfully to produce microbiosensors capable of monitoring glucose metabolism in 96 well format cell cultures. The potential application areas for these microbiosensors are discussed.


Asunto(s)
Técnicas Biosensibles/métodos , Técnicas de Cultivo de Célula , Glucosa/aislamiento & purificación , Microtecnología/métodos , Línea Celular , Electroquímica/métodos , Glucosa/química , Glucosa Oxidasa/química , Indoles/química , Microelectrodos , Compuestos Organometálicos/química , Agua/química
6.
Anal Biochem ; 428(1): 39-43, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22705172

RESUMEN

A screen-printed carbon electrode (SPCE) incorporating the electrocatalyst cobalt phthalocyanine (CoPC), fabricated using a water-based ink formulation, has been investigated as the base transducer for a uric acid biosensor. A sandwich biosensor was fabricated by first depositing cellulose acetate (CA) onto this transducer (CoPC-SPCE), followed by uricase (UOX) and finally a polycarbonate (PC) membrane; this device is designated PC-UOX-CA-CoPC-SPCE. This biosensor was used in conjunction with chronoamperometry to optimize the conditions for the analysis of urine: temperature, 35°C; buffer, pH 9.2; ionic strength, 50 mM; uricase, 0.6 U; incubation time, 180 s. The proposed biosensor was applied to urine from a healthy subject. The precision determined on unspiked urine (n=6) was 5.82%. Urine was fortified with 0.225 mM UA, and the resulting precision and recovery were 4.21 and 97.3%, respectively. The linear working range of the biosensor was found to be 0.015 to 0.25 mM (the former represents the detection limit), and the sensitivity was calculated to be 2.10 µA/mM.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Electroquímica/instrumentación , Electroquímica/métodos , Ácido Úrico/orina , Urinálisis/instrumentación , Urinálisis/métodos , Tampones (Química) , Calibración , Humanos
7.
Biosens Bioelectron ; 26(6): 2847-51, 2011 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-21163641

RESUMEN

Organophosphate pesticides present serious risks to human and environmental health. A rapid reliable, economical and portable analytical system will be of great benefit in the detection and prevention of contamination. A biosensor array based on six acetylcholinesterase enzymes for use in a novel automated instrument incorporating a neural network program is described. Electrochemical analysis was carried out using chronoamperometry and the measurement was taken 10s after applying a potential of 0 V vs. Ag/AgCl. The total analysis time for the complete assay was less than 6 min. The array was used to produce calibration data with six organophosphate pesticides (OPs) in the concentration range of 10(-5) M to 10(-9) M to train a neural network. The output of the neural network was subsequently evaluated using different sample matrices. There were no detrimental matrix effects observed from water, phosphate buffer, food or vegetable extracts. Furthermore, the sensor system was not detrimentally affected by the contents of water samples taken from each stage of the water treatment process. The biosensor system successfully identified and quantified all samples where an OP was present in water, food and vegetable extracts containing different OPs. There were no false positives or false negatives observed during the evaluation of the analytical system. The biosensor arrays and automated instrument were evaluated in situ in field experiments where the instrument was successfully applied to the analysis of a range of environmental samples. It is envisaged that the analytical system could provide a rapid detection system for the early warning of contamination in water and food.


Asunto(s)
Técnicas Biosensibles/instrumentación , Organofosfatos/análisis , Plaguicidas/análisis , Acetilcolinesterasa , Automatización , Técnicas Biosensibles/métodos , Técnicas Biosensibles/estadística & datos numéricos , Técnicas Electroquímicas , Enzimas Inmovilizadas , Diseño de Equipo , Contaminación de Alimentos/análisis , Humanos , Redes Neurales de la Computación , Contaminantes Químicos del Agua/análisis
8.
Biosens Bioelectron ; 26(5): 2448-53, 2011 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-21081270

RESUMEN

Microband biosensors, screen-printed from a water-based carbon ink containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, were used to monitor glucose levels continuously in buffer and culture medium. Five biosensors were operated amperometrically (E(app) of +0.4V), in a 12-well tissue culture plate system at 37°C, using a multipotentiostat. After 24 h, a linear calibration plot was obtained from steady-state current responses for glucose concentrations up to 10 mM (dynamic range 30 mM). Within the linear region, a correlation coefficient (R(2)) of 0.981 was obtained between biosensor and spectrophotometric assays. Over 24 h, an estimated 0.15% (89 nmol) of the starting glucose concentration (24 mM) was consumed by the microbiosensor. The sensitivity of the biosensor response in full culture medium was stable between pHs 7.3 and 8.4. Amperometric responses for HepG2 monolayer cultures decreased with time in inverse proportionality to cell number (for 0 to 10(6) cell/ml), as glucose was being metabolised. HepG2 3D cultures (spheroids) were also shown to metabolise glucose, at a rate which was independent of spheroid age (between 6 and 15 days). Spheroids were used to assay the effect of a typical hepatotoxin, paracetamol. At 1 mM paracetamol, glucose uptake was inhibited by 95% after 6 h in culture; at 500 µM, around 15% inhibition was observed after 16 h. This microband biosensor culture system could form the basis for an in vitro toxicity testing system.


Asunto(s)
Acetaminofén/toxicidad , Bioensayo/instrumentación , Técnicas Biosensibles/instrumentación , Supervivencia Celular/efectos de los fármacos , Conductometría/instrumentación , Glucosa/análisis , Sistemas de Computación , Diseño de Equipo , Análisis de Falla de Equipo , Células Hep G2 , Humanos
9.
J Cardiovasc Surg (Torino) ; 51(6): 799-806, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21124276

RESUMEN

Over the past several years, there has been continued significant interest in refinement of patient selection, devices, procedures and protocols in an effort to optimize the outcome of percutaneous intervention for carotid bifurcation stenosis, including: ongoing National Institutes of Health and manufacturer trials and registries; the further refinement of existing devices and emergence of new platforms to attain distal embolic protection; ongoing study of what really constitutes a high-risk carotid surgery or stenting patient; and attention to device characteristics and patient-device matching. Within the latter area, considerable interest has focused on stent characteristics that have the potential to impact short and long-term outcome when compared with other stent design strategies when studied in large series. The stent in carotid artery intervention occupies a unique role in that after the embolic protection system has been removed, it is the main line of defense (in concert with aggressive dual antiplatelet therapy) from embolic and thromboembolic complications that may arise from the newly remodeled plaque after post-stent angioplasty. In this review, we aim to update the current status of efforts to relate stent design strategy to outcome in intervention for extracranial carotid artery disease with a focus primarily on the function of "free cell area" (typically lower with closed-cell stents and higher with open-cell stents) in analyses of outcome in carotid artery stenting. Also, the potential role of closed-cell vs. open-cell stent selection in other reports related to carotid artery stenting outcome or complications is reviewed. Rigorous studies have examined the issue of free cell area and arrived at disparate conclusions. Randomized data on the impact of free cell area and cell design strategy on carotid intervention are presently lacking. However, we believe sufficient data and rationale exist 1) to warrant ongoing study of the impact of stent design on outcome in carotid intervention; and 2) to make consideration of closed-cell (low free cell area) stent use a reasonable approach to device selection--when patient factors, lesion characteristics, or device availability make doing so possible.


Asunto(s)
Angioplastia/instrumentación , Estenosis Carotídea/terapia , Infarto Cerebral/prevención & control , Stents , Angioplastia/efectos adversos , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Infarto Cerebral/etiología , Infarto Cerebral/patología , Humanos , Imagen por Resonancia Magnética , Selección de Paciente , Diseño de Prótesis , Radiografía , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Ultrasonografía Intervencional
10.
Talanta ; 82(1): 34-7, 2010 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-20685431

RESUMEN

A biosensor for the measurement of lactate in serum has been developed, which is based on a screen-printed carbon electrode, modified with Meldola's Blue-Reinecke Salt (MBRS-SPCE), coated with the enzyme lactate dehydrogenase NAD(+) dependent (from Porcine heart), and NAD(+). A cellulose acetate layer was deposited on the top of the device to act as a permselective membrane. The biosensor was incorporated into a commercially available, thin-layer, amperometric flow cell operated at a potential of only +0.05 V vs. Ag/AgCl. The mobile phase consisted of 0.2 M phosphate buffer pH 10 containing 0.1 M potassium chloride solution; a flow rate of 0.8 ml min(-1) was used throughout the investigation. The biosensor response was linear over the range 0.55-10 mM lactate; the former represents the detection limit. The precision of the system was determined by carrying out 10 repeat injections of 10 mM l(+)lactic acid standard; the calculated coefficient of variation was 4.28%. It was demonstrated that this biosensor system could be applied to the direct measurement of lactate in serum without pre-treatment; therefore, this would allow high throughput-analysis, at low cost, for this clinically important analyte.


Asunto(s)
Técnicas Biosensibles/métodos , Carbono/química , L-Lactato Deshidrogenasa/metabolismo , Ácido Láctico/análisis , NAD/metabolismo , Oxazinas/química , Tiocianatos/química , Animales , Bovinos , Electroquímica , Electrodos , Análisis de Inyección de Flujo , Concentración de Iones de Hidrógeno , Ácido Láctico/sangre , Impresión , Porcinos
11.
Anal Biochem ; 396(2): 269-74, 2010 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19766585

RESUMEN

A biosensor for the measurement of glucose in serum has been developed, based on a screen-printed carbon electrode modified with Meldola's Blue-Reinecke salt, coated with the enzyme glucose dehydrogenase (from Bacillus sp.), and nicotinamide adenine dinucleotide coenzyme (NAD+). A cellulose acetate layer was deposited on top of the device to act as a permselective membrane. The biosensor was incorporated into a commercially available, thin-layer, amperometric flow cell operated at a potential of only +0.05 V versus Ag/AgCl. The mobile phase consisted of 0.2 M phosphate buffer (pH 7.0) containing 0.1 M potassium chloride solution, and a flow rate of 0.8 ml min(-1) was used throughout the investigation. The biosensor response was linear over the range of 0.075-30 mM glucose, with the former representing the detection limit. The precision of the system was determined by carrying out 20 repeat injections of a 5-mM glucose standard, and the calculated coefficient of variation was 3.9%. It was demonstrated that this biosensor system could be applied to the direct measurement of glucose in serum without pretreatment. Therefore, this would allow high-throughput analysis, at low cost, for this clinically important analyte.


Asunto(s)
Técnicas Biosensibles/instrumentación , Glucemia/análisis , Carbono/química , Análisis de Inyección de Flujo/métodos , Glucosa 1-Deshidrogenasa/metabolismo , Oxazinas/química , Tiocianatos/química , Técnicas Biosensibles/métodos , Celulosa/análogos & derivados , Celulosa/química , Electrodos , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Glucosa 1-Deshidrogenasa/química , Ensayos Analíticos de Alto Rendimiento/métodos , Límite de Detección , NAD/química , NAD/metabolismo
12.
Anal Biochem ; 393(2): 242-7, 2009 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-19576165

RESUMEN

An amperometric assay for the determination of inorganic phosphate (Pi) in urine has been developed without the need for sample preparation. A screen-printed carbon electrode modified with the electrocatalyst cobalt phthalocyanine (CoPC-SPCE) and covered with a cellulose acetate membrane (CAM) serves as the sensor. The sensor detects hydrogen peroxide (H(2)O(2)), which is produced as a result of the oxidative decarboxylation of pyruvate, catalyzed by pyruvate oxidase (PyOd), in the presence of Pi, oxygen, and cofactors. Following optimization of solution conditions, and in the presence of a urine sample, a linear range was found to exist between the rate of current increase and phosphate concentration over the range of 2.27 x 10(-5) to 1.81 x 10(-4)M, and the limit of detection was found to be 4.27 x 10(-6)M. The assay was applied to the determination of phosphate ions in the urine of a normal subject, and the mean concentration in unspiked urine was found to be 3.40 x 10(-5)M with a coefficient of variation of 8.0% (n=5). The mean recovery of phosphate added to urine samples was 98.7% with a coefficient of variation of 5.5% (n=3). To the authors' knowledge, this is the first report of an amperometric assay for Pi that incorporates a CoPC-SPCE as the sensing device.


Asunto(s)
Técnicas Biosensibles/instrumentación , Electrodos de Iones Selectos , Microquímica/instrumentación , Fosfatos/orina , Piruvato Oxidasa/metabolismo , Calibración , Carbono , Celulosa/análogos & derivados , Coenzimas/metabolismo , Descarboxilación , Enzimas Inmovilizadas , Humanos , Peróxido de Hidrógeno/análisis , Concentración de Iones de Hidrógeno , Indoles , Membranas Artificiales , Compuestos Organometálicos , Ácido Pirúvico , Temperatura
13.
Biosens Bioelectron ; 24(5): 1246-52, 2009 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-18778930

RESUMEN

Microband glucose biosensors were fabricated by screen-printing a water-based carbon ink formulation containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, then insulating and sectioning through the thick (20mum) film to expose a 3mm-long working electrode edge. The performance of these biosensors for glucose analysis was investigated at 25 degrees C. Voltammetry in glucose-containing buffer solutions established that an operating potential of +0.4V vs. Ag/AgCl was suitable for analysis under both stirring and quiescent conditions. The influence of pH on biosensor performance was established and an operational pH of 8.0 was selected. Steady-state responses were obtained under quiescent conditions, suggesting a mixed mechanism predominated by radial diffusion, indicative of microelectrode behaviour. Calibration studies obtained with these biosensors showed steady-state currents that were linearly dependent on glucose concentration from the limit of detection (0.27mM) up to 2.0mM, with a precision for replicate biosensors of 6.2-10.7%. When applied to the determination of glucose in human serum, the concentration compared favourably to that determined by a spectroscopic method. These results have demonstrated a simple means of fabricating biosensors for glucose measurement and determination in situations where low-current real-time monitoring under quiescent conditions would be desirable.


Asunto(s)
Técnicas Biosensibles/instrumentación , Análisis Químico de la Sangre/instrumentación , Glucemia/análisis , Carbono/química , Electroquímica/instrumentación , Microelectrodos , Técnicas Biosensibles/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Tinta , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Agua/química
14.
Talanta ; 77(3): 1149-54, 2009 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19064104

RESUMEN

The present study demonstrated for the first time that screen-printed carbon microband electrodes fabricated from water-based ink can readily detect H(2)O(2) and that the same ink, with the addition of lactate oxidase, can be used to construct microband biosensors to measure lactate. These microband devices were fabricated by a simple cutting procedure using conventional sized screen-printed carbon electrodes (SPCEs) containing the electrocatalyst cobalt phthalocyanine (CoPC). These devices were characterised with H(2)O(2) using several electrochemical techniques. Cyclic voltammograms were found to be sigmoidal; a current density value of 4.2 mA cm(-2) was obtained. A scan rate study revealed that the mass transport mechanism was a mixture of radial and planar diffusion. However, a further amperometric study under quiescent and hydrodynamic conditions indicated that radial diffusion predominated. A chronoamperometric study indicated that steady-state currents were obtained with these devices for a variety of H(2)O(2) concentrations and that the currents were proportional to the analyte concentration. Lactate microband biosensors were then fabricated by incorporating lactate oxidase into the water-based formulation prior to printing and then cutting as described. Voltammograms demonstrated that lactate oxidase did not compromise the integrity of the electrode for H(2)O(2) detection. A potential of +400 mV was selected for a calibration study, which showed that lactate could be measured over a dynamic range of 1-10mM which was linear up to 6mM; a calculated lower limit of detection of 289 microM was ascertained. This study provides a platform for monitoring cell metabolism in-vitro by measuring lactate electrochemically via a microband biosensor.


Asunto(s)
Técnicas Biosensibles/métodos , Carbono/química , Tinta , Ácido Láctico/análisis , Ácido Láctico/química , Impresión , Agua/química , Tampones (Química) , Calibración , Catálisis , Electrodos , Peróxido de Hidrógeno/química , Concentración de Iones de Hidrógeno
15.
Anal Biochem ; 385(2): 334-41, 2009 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-19027709

RESUMEN

Microband glucose biosensors were produced by insulating and sectioning through a screen-printed, water-based carbon electrode containing cobalt phthalocyanine redox mediator and glucose oxidase enzyme. Under quiescent conditions at 37 degrees C, at an operating potential of +0.4V, they produced an amperometric response to glucose in buffer solutions with a sensitivity of 26.4 nA/mM and a linear range of 0.45 to 9.0 mM. An optimal pH value of 8.5 was obtained under these conditions, and a value for activation energy of 40.55 kJ mol(-1) was calculated. In culture medium (pH 7.3), a sensitivity of 13 nA/mM was obtained and the response was linear up to 5 mM with a detection limit of 0.5 mM. The working concentration was up to 20 mM glucose with a precision of 11.3% for replicate biosensors (n=4). The microband biosensors were applied to determine end-point glucose concentrations in culture medium by monitoring steady-state current responses 400 s after transfer of the biosensors into different sample solutions. In conjunction with cultures of HepG2 (human Caucasian hepatocyte carcinoma) cells, current responses obtained in 24-h supernatants showed an inverse correlation (R(2)=0.98) with cell number, indicating that the biosensors were applicable for monitoring glucose metabolism by cells and of quantifying cell number. Glucose concentrations determined using the biosensor assay were in good agreement, for concentrations up to 20mM, with those determined spectrophotometrically (R(2)=0.99). This method of end-point glucose determination was used to provide an estimated rate of glucose uptake for HepG2 cells of 7.9 nmol/(10(6) cells min) based on a 24-h period in culture.


Asunto(s)
Técnicas Biosensibles/métodos , Recuento de Células/instrumentación , Glucosa/análisis , Técnicas Biosensibles/instrumentación , Línea Celular Tumoral , Electroquímica/instrumentación , Electroquímica/métodos , Humanos , Reproducibilidad de los Resultados
16.
Talanta ; 75(5): 1221-6, 2008 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-18585205

RESUMEN

This paper reports on the development of a novel electrochemical assay for Zn(2+) in human sweat, which involves the use of disposable screen-printed carbon electrodes (SPCEs). Initially, SPCEs were used in conjunction with cyclic voltammetry to study the redox characteristics of Zn(2+) in a selection of supporting electrolytes. The best defined cathodic and anodic peaks were obtained with 0.1 M NaCl/0.1 M acetate buffer pH 6.0. The anodic peak was sharp and symmetrical which is typical for the oxidation of a thin metal film on the electrode surface. This behaviour was exploited in the development of a differential pulse anodic stripping voltammetric (DPASV) assay for zinc. It was shown that a deposition potential of -1.6 V versus Ag/AgCl and deposition time of 60 s with stirring (10 s equilibration) produced a well-defined stripping peak with E(pa) = -1.2 V versus Ag/AgCl. Using these conditions, the calibration plot was linear over the range 1x10(-8) to 5x10(-6) M Zn(2+). The precision was examined by carrying out six replicate measurements at a concentration of 2x10(-6) M; the coefficient of variation was calculated to be 5.6%. The method was applied to the determination of the analyte in sweat from 10 human volunteers. The concentrations were between 0.39 and 1.56 microg/mL, which agrees well with previously reported values. This simple, low-cost sensitive assay should have application in biomedical studies and for stress and fatigue in sports studies.


Asunto(s)
Bioensayo/métodos , Técnicas Biosensibles/métodos , Carbono/química , Mercurio/química , Sudor/química , Zinc/análisis , Bioensayo/instrumentación , Técnicas Biosensibles/instrumentación , Tampones (Química) , Electroquímica , Electrodos , Humanos , Concentración de Iones de Hidrógeno , Sensibilidad y Especificidad , Plata/química , Compuestos de Plata/química , Deportes/fisiología
17.
J Biochem Biophys Methods ; 63(3): 201-12, 2005 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-15975659

RESUMEN

Investigations into the development of a prototype electrochemical immunosensor for estradiol (E(2)) are described. After optimising reagent loadings in a 96-well enzyme-linked immunosorbent assay (ELISA), antibodies (rabbit anti-mouse IgG and monoclonal mouse anti-E(2)) were immobilised by passive adsorption onto the surface of screen-printed carbon electrodes (SPCEs). A competitive immunoassay was then performed using an alkaline-phosphatase (ALP)-labelled E(2) conjugate. Calibration plots for E(2) buffer standards, performed colorimetrically on the SPCEs using a para-nitrophenyl phosphate substrate solution, were in good agreement with ELISA calibration plots. Electrochemical measurements were then performed using differential pulse voltammetry (DPV) following the production of 1-naphthol from 1-naphthyl phosphate. The calibration plot of DPV peak current versus E(2) concentration showed a measurable range of 25-500 pg/ml with a detection limit of 50 pg/ml. A coefficient of variation of between 13.0 and 15.6% was obtained for repeat measurements. The immunosensor was applied to the determination of E(2) in spiked serum, following an extraction step with diethyl ether. A mean recovery for the method of 102.5% was obtained with a CV of 19.1%. The options available for further development of the sensor regarding precision, limit of detection and direct sample analysis are discussed.


Asunto(s)
Carbono/química , Electroquímica/métodos , Estradiol/sangre , Anticuerpos Monoclonales/química , Biotinilación , Calibración , Colorimetría , Electrodos , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunoensayo , Inmunoglobulina G/química , Modelos Químicos , Naftalenos/química , Naftoles/química , Compuestos Organofosforados/química
18.
Biosens Bioelectron ; 19(4): 305-12, 2003 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-14615087

RESUMEN

Screen-printed carbon electrodes (SPCEs) have been successfully exploited as disposable sensors for the measurement of 2,6-dinitrotoluene (2,6-DNT) using a stripping voltammetric method. Initial investigations were undertaken using cyclic voltammetry (CV) to characterise the redox behaviour at the SPCEs. Further studies were then performed to deduce the optimum applied potential and accumulation time for the stripping voltammetric procedure. In addition, a study was carried out to ascertain whether small volumes of samples could be reliably used for analysis. From these studies it was shown that a 100 microl aliquot of sample could be analysed and the calibration plot was linear from 161 ng ml(-1) to 137 microg ml(-1) (R(2)=0.9991), the former concentration being the detection limit. The effects of the major components of human saliva at concentrations normally present were investigated. Of the individual components tested, only Cl(-) and albumen were found to interfere. The presence of the latter could be easily overcome by the addition of (NH(4))(2)SO(4). An interference study was also carried out on some inorganic and organic species that may be present in water samples. The sensors were evaluated by carrying out 2,6-DNT determinations on spiked and unspiked human saliva, dust wipe and potable water samples. Mean recoveries of 47.5, 73.4 and 102.4% were obtained; coefficients of variation of 7.88, 6.63 and 6.42% were calculated for a concentration of 9.1 microg ml(-1) in water, 10.6 microg ml(-1) saliva samples, and 141.1 ng cm(-2) for dust wipe samples, respectively. The performance characteristics show that the method holds promise and reliable data may be obtained for 2,6-DNT in bioanalysis and public health.


Asunto(s)
Carbono/química , Dinitrobencenos/análisis , Dinitrobencenos/química , Electroquímica/métodos , Microquímica/métodos , Saliva/química , Contaminantes Químicos del Agua/análisis , Polvo/análisis , Electroquímica/instrumentación , Electrodos , Humanos , Microquímica/instrumentación , Exposición Profesional/análisis , Vigilancia de la Población/métodos , Reproducibilidad de los Resultados , Medidas de Seguridad , Sensibilidad y Especificidad , Terrorismo/prevención & control
19.
J Vasc Surg ; 37(5): 1091-3, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12756359

RESUMEN

Iliac arteriovenous (AV) fistula is rare after lumbar disk surgery. Traditionally, open repair through the arterial lumen was performed. We report endovascular exclusion of an iliac AV fistula in a 41-year-old woman 8 years after lumbar diskectomy. An angiogram showed an AV fistula connecting the right common iliac artery and vein. This was repaired with placement of two covered wall stents in the right common artery and external iliac artery, and embolization of the right internal iliac artery. Contrast medium-enhanced computed tomography scan at 5 months confirmed elimination of the AV fistula and right iliac artery patency. This technique should be considered in management of iliac AV fistulas.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Arteria Ilíaca/cirugía , Vena Ilíaca/cirugía , Disco Intervertebral/cirugía , Adulto , Derivación Arteriovenosa Quirúrgica/efectos adversos , Discectomía , Femenino , Humanos , Vértebras Lumbares/cirugía , Reoperación
20.
Biosens Bioelectron ; 17(5): 389-94, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-11888729

RESUMEN

The possibility of developing amperometric biosensors for the measurement of SO(2) in flowing gas streams has been examined. Screen-printed carbon electrodes (SPCEs) were tailored with the enzyme sulfite oxidase and cytochrome c and the response is generated through the resulting enzymatic and electrocatalytic reactions involving SO(3)(2-), formed when SO(2) gas is dissolved in the supporting electrolyte. Two methods of integrating the enzyme and cytochrome c with the SPCE were investigated. In one design (b-type biosensor), the components were mixed thoroughly with the same ink used to produce the SPCEs, then the modified ink was spread over the working electrode. In the second approach the bio-components were dissolved in the supporting electrolyte and simply deposited on top of the transducer (s-type biosensor). Both devices gave linear responses over the range 4--50 ppm but the sensitivity of the s-type was approximately twice that of the b-type biosensor. In addition, the time taken to reach 90% of the maximum response (t(90%)) was 110 s for the s-type biosensor compared with 200 s for the b-type biosensor. These studies illustrate the successful use of biosensors for the detection of sulfur dioxide at the relatively low potential of +0.3 V versus Ag.AgCl and should provide useful alternatives for decentralised environmental studies.


Asunto(s)
Técnicas Biosensibles , Dióxido de Azufre/análisis , Técnicas Biosensibles/instrumentación , Carbono , Grupo Citocromo c , Electrodos , Electrónica Médica , Monitoreo del Ambiente/instrumentación , Diseño de Equipo , Concentración de Iones de Hidrógeno , Oxidorreductasas actuantes sobre Donantes de Grupos Sulfuro , Transductores
SELECCIÓN DE REFERENCIAS