Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 61(11): 4201-22, 2016 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-27192396

RESUMEN

The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3-5% higher than the calorimetry, within the stated uncertainties.


Asunto(s)
Calorimetría/métodos , Dosis de Radiación , Dosímetros de Radiación/normas , Calibración , Calorimetría/normas , Grafito , Humanos , Radioterapia/instrumentación , Radioterapia/métodos , Estándares de Referencia , Sincrotrones , Rayos X
2.
Phys Med Biol ; 60(22): 8625-41, 2015 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-26510214

RESUMEN

Small circular beams of synchrotron radiation (0.1 mm and 0.4 mm in diameter) were used to irradiate ionization chambers of the types commonly used in radiotherapy. By scanning the chamber through the beam and measuring the ionization current, a spatial map of the dosimetric response of the chamber was recorded. The technique is able to distinguish contributions to the large-field ionization current from the chamber walls, central electrode and chamber stem. Scans were recorded for the NE 2571 Farmer chamber, the PTW 30013, IBA FC65-G Farmer-type chambers, the NE 2611A and IBA CC13 thimble chambers, the PTW 31006 and 31014 pinpoint chambers, the PTW Roos and Advanced Markus plane-parallel chambers, and the PTW 23342 thin-window soft x-ray chamber. In all cases, large contributions to the response arise from areas where the incident beam grazes the cavity surfaces. Quantitative as well as qualitative information about the relative chamber response was extracted from the maps, including the relative contribution of the central electrode. Line scans using monochromatic beams show the effect of the photon energy on the chamber response. For Farmer-type chambers, a simple Monte Carlo model was in good agreement with the measured response.


Asunto(s)
Modelos Teóricos , Fantasmas de Imagen , Radiometría/instrumentación , Radiometría/métodos , Sincrotrones/instrumentación , Electrodos , Humanos , Método de Montecarlo , Fotones , Rayos X
3.
Radiat Prot Dosimetry ; 164(3): 181-6, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25209996

RESUMEN

The authors report the results of an indirect comparison of the standards of absorbed dose to water in high-energy photon beams from a clinical linac and (60)Co radiation beam performed between the National Metrology Institute of Japan (NMIJ) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Three ionisation chambers were calibrated by the NMIJ in April and June 2013 and by the ARPANSA in May 2013. The average ratios of the calibration coefficients for the three ionisation chambers obtained by the NMIJ to those obtained by the ARPANSA were 0.9994, 1.0040 and 1.0045 for 6-, 10- and 15-MV (18 MV at the ARPANSA) high-energy photon beams, respectively. The relative standard uncertainty of the value was 7.2 × 10(-3). The ratio for (60)Co radiation was 0.9986(66), which is consistent with the results published in the key comparison of BIPM.RI(I)-K4.


Asunto(s)
Calibración/normas , Aceleradores de Partículas/normas , Fotones , Radiometría/normas , Radioterapia de Alta Energía/normas , Agua/química , Academias e Institutos , Australia , Radioisótopos de Cobalto/análisis , Radioisótopos de Cobalto/normas , Humanos , Japón , Aceleradores de Partículas/instrumentación , Radiometría/instrumentación , Radioterapia de Alta Energía/instrumentación , Estándares de Referencia , Reproducibilidad de los Resultados
4.
Australas Phys Eng Sci Med ; 37(4): 753-61, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25146559

RESUMEN

The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) maintains the Australian primary standard of absorbed dose. Until recently, the standard was used to calibrate ionisation chambers only in (60)Co gamma rays. These chambers are then used by radiotherapy clinics to determine linac output, using a correction factor (k Q) to take into account the different spectra of (60)Co and the linac. Over the period 2010-2013, ARPANSA adapted the primary standard to work in megavoltage linac beams, and has developed a calibration service at three photon beams (6, 10 and 18 MV) from an Elekta Synergy linac. We describe the details of the new calibration service, the method validation and the use of the new calibration factors with the International Atomic Energy Agency's TRS-398 dosimetry Code of Practice. The expected changes in absorbed dose measurements in the clinic when shifting from (60)Co to the direct calibration are determined. For a Farmer chamber (model 2571), the measured chamber calibration coefficient is expected to be reduced by 0.4, 1.0 and 1.1 % respectively for these three beams when compared to the factor derived from (60)Co. These results are in overall agreement with international absorbed dose standards and calculations by Muir and Rogers in 2010 of k Q factors using Monte Carlo techniques. The reasons for and against moving to the new service are discussed in the light of the requirements of clinical dosimetry.


Asunto(s)
Calibración/normas , Aceleradores de Partículas/instrumentación , Radiometría/instrumentación , Radiometría/normas , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/normas , Australia , Radioisótopos de Cobalto/análisis , Radioisótopos de Cobalto/normas , Fotones/uso terapéutico , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Med Phys ; 41(5): 052101, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24784390

RESUMEN

PURPOSE: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. METHODS: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. RESULTS: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. CONCLUSIONS: The good agreement of the graphite calorimeter and free-air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free-air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.


Asunto(s)
Calorimetría/instrumentación , Grafito , Radiometría/métodos , Sincrotrones/instrumentación , Rayos X , Aire , Algoritmos , Método de Montecarlo , Presión , Dosis de Radiación , Temperatura , Incertidumbre , Agua
6.
Radiat Prot Dosimetry ; 155(1): 100-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23152147

RESUMEN

The ARPANSA calibration service for (60)Co gamma rays is based on a primary standard graphite calorimeter that measures absorbed dose to graphite. Measurements with the calorimeter are converted to the absorbed dose to water using the calculation of the ratio of the absorbed dose in the calorimeter to the absorbed dose in a water phantom. ARPANSA has recently changed the basis of this calculation from a photon fluence scaling method to a direct Monte Carlo (MC) calculation. The MC conversion uses an EGSnrc model of the cobalt source that has been validated against water tank and graphite phantom measurements, a step that is required to quantify uncertainties in the underlying interaction coefficients in the MC code. A comparison with the Bureau International des Poids et Mesures (BIPM) as part of the key comparison BIPM.RI(I)-K4 showed an agreement of 0.9973 (53).


Asunto(s)
Radioisótopos de Cobalto , Grafito/efectos de la radiación , Método de Montecarlo , Fantasmas de Imagen , Agua/química , Absorción , Calibración , Humanos , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...