Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Int Soc Sports Nutr ; 21(1): 2341903, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38626029

RESUMEN

Protein supplementation often refers to increasing the intake of this particular macronutrient through dietary supplements in the form of powders, ready-to-drink shakes, and bars. The primary purpose of protein supplementation is to augment dietary protein intake, aiding individuals in meeting their protein requirements, especially when it may be challenging to do so through regular food (i.e. chicken, beef, fish, pork, etc.) sources alone. A large body of evidence shows that protein has an important role in exercising and sedentary individuals. A PubMed search of "protein and exercise performance" reveals thousands of publications. Despite the considerable volume of evidence, it is somewhat surprising that several persistent questions and misconceptions about protein exist. The following are addressed: 1) Is protein harmful to your kidneys? 2) Does consuming "excess" protein increase fat mass? 3) Can dietary protein have a harmful effect on bone health? 4) Can vegans and vegetarians consume enough protein to support training adaptations? 5) Is cheese or peanut butter a good protein source? 6) Does consuming meat (i.e., animal protein) cause unfavorable health outcomes? 7) Do you need protein if you are not physically active? 8) Do you need to consume protein ≤ 1 hour following resistance training sessions to create an anabolic environment in skeletal muscle? 9) Do endurance athletes need additional protein? 10) Does one need protein supplements to meet the daily requirements of exercise-trained individuals? 11) Is there a limit to how much protein one can consume in a single meal? To address these questions, we have conducted a thorough scientific assessment of the literature concerning protein supplementation.


Asunto(s)
Proteínas en la Dieta , Resistencia Física , Humanos , Resistencia Física/fisiología , Ejercicio Físico/fisiología , Suplementos Dietéticos , Músculo Esquelético/fisiología
2.
Nutrients ; 16(5)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38474845

RESUMEN

This study compared flavored kefir (KFR) and flavored milk (MLK) as a recovery drink in endurance master athletes. Using a randomized, placebo-controlled, non-blinded crossover design, 11 males and females completed three testing visits whilst acutely ingesting either KFR, MLK, or water as a placebo (PLA). KFR supplementation occurred for 14 days before the KFR-testing day, followed by a 3-week washout period. Testing visits consisted of an exhausting-exercise (EE) bout, a 4-h rest period where additional carbohydrate feeding was provided, and a treadmill 5 km time trial (TT). The Gastrointestinal Symptom Rating Scale (GSRS) survey was assessed at four timepoints. Blood was collected at baseline and after the TT and was analyzed for I-FABP levels. No significant difference (PLA: 33:39.1 ± 6:29.0 min, KFR: 33:41.1 ± 5:44.4 min, and MLK: 33:36.2 ± 6:40.5 min, p = 0.99) was found between the groups in TT performance. The KFR GSRS total score was significantly lower than the PLA after EE (p = 0.005). No differences in I-FABP were observed between conditions. In conclusion, acute KFR supplementation did not impact TT performance or I-FABP levels but may have reduced subjective GI symptoms surrounding exercise when compared to MLK or PLA.


Asunto(s)
Kéfir , Carrera , Masculino , Femenino , Humanos , Animales , Leche , Agua , Atletas , Poliésteres , Resistencia Física , Estudios Cruzados
4.
Front Sports Act Living ; 5: 1239121, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37841887

RESUMEN

The prevalence of dietary supplement use among athletes continues to rise with 60-80% of athletes often reporting current or previous use of dietary supplements. While select dietary ingredients have been shown to improve acute performance and enhance training adaptations over time, it is important to still consider the risk vs. reward for athletes before opting to consume a dietary supplement. Previous work has indicated that certain dietary supplements may pose risks for inadvertent doping, may be susceptible to mislabelling, could be banned by certain governing bodies of sport, or pose health risks for certain populations. The purpose of the current narrative review is to summarize the prevalence of adulteration in dietary sport supplement products, outline the risks of inadvertent doping for athletes, and highlight best practices regarding safe supplementation strategies. Analytical studies have found anywhere from 14 to 50% of samples analyzed from dietary supplement products have tested positive for anabolic agents or other prohibited substances. It is important for the consumer to adhere to safe supplementation strategies, which include following serving size recommendations, cross-referencing ingredient profiles with the list of prohibited substances, choosing quality products that have been verified by a third-party certification program, and being cognizant of consuming multiple dietary supplement products with overlapping ingredient profiles. Once these practices have been considered, it is reasonable for an athlete to utilize dietary supplements as a strategy to optimize performance and health, with a low risk of failing a drug test (adverse analytical finding) and experiencing adverse events.

5.
J Acad Nutr Diet ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37742826

RESUMEN

BACKGROUND: Pre-exercise meal frequency is commonly believed to impact exercise performance, but little is known about its impact on resistance training. OBJECTIVE: This study investigated the impact of breakfast consumption on afternoon resistance training performance in habitual breakfast consumers and nonconsumers. DESIGN: A randomized, crossover study was conducted in Lubbock, TX between November 2021 and May 2022. PARTICIPANTS: Thirty-nine resistance-trained male (n = 20) and female (n = 19) adults (mean ± SD age 23.0 ± 4.7 years) who habitually consumed (≥5 d/wk; n = 19) or did not consume (≥5 d/wk; n = 20) breakfast completed the study. INTERVENTION: After the establishment of 1-repetition maximums at the first visit, participants completed 2 additional visits, each of which included 4 sets of barbell back squat, bench press, and deadlift, using 80% of their 1-repetition maximum after either consuming breakfast and lunch or the same food at lunch only. MAIN OUTCOME MEASURES: Repetitions, along with average and peak average concentric velocity and power, were measured for all repetitions throughout each exercise session. Visual analog scales were used to assess feelings of fatigue, energy, focus, hunger, desire to eat, and fullness throughout each exercise session. STATISTICAL ANALYSES PERFORMED: Data were analyzed using linear mixed-effects models. RESULTS: No interactions or main effects involving condition or habitual breakfast consumption were observed for resistance training outcomes, although sex differences were noted. Male participants performed significantly fewer repetitions on sets 2, 3, and 4 (P < .014) for total repetitions, on sets 2 and 4 for barbell back squat (P < .023), and set 4 for deadlift (P = .006), with no observed differences between sexes for bench press repetitions. Male participants displayed reductions in average power across all sets and exercises except deadlift. CONCLUSIONS: These data suggest that alterations in pre-exercise meal frequency may not influence afternoon resistance training performance provided similar total nutritional intake is consumed.

6.
J Electr Bioimpedance ; 14(1): 3-12, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37416523

RESUMEN

This study evaluated the influence of novel beverage formulations on bioimpedance- and urine-based hydration markers. Thirty young healthy adults (n=16 females, n=14 males; age: 23.2±3.7 years; BMI: 24.3±3.3 kg/m2) participated in a randomized, double-blind, placebo-controlled, crossover study. Participants completed three conditions with baseline bioimpedance, urine, and body mass assessments, followed by ingestion of one liter of a test beverage over a 30-minute period. The three beverages were: active hydration formulation in still (AFstill) or sparkling (AFspark) water and a still water control. The active formulations were identical in concentrations of alpha-cyclodextrin and complexing agents. Following beverage ingestion, bioimpedance assessments were performed every 15 minutes for two hours, followed by final urinary and body mass assessments. The primary bioimpedance outcomes were phase angle at 50 kHz, resistance of the extra-cellular compartment (R0), and resistance of the intracellular compartment (Ri). Data were analyzed using linear mixed effects models, Friedman tests, and Wilcoxon tests. Statistically significant changes in phase angle values were observed at 30 (p=0.004) and 45 minutes (p=0.024) following the initiation of beverage ingestion in the AFstill condition as compared to the reference model (i.e., control condition at baseline). Although differences between conditions were not statistically significant at later time points, the data were consistent with AFstill having greater elevations in phase angle throughout the monitoring period. At the 30-minute time point only, statistically significant differences in R0 for AFspark (p<0.001) and in Ri for AFstill (p=0.008) were observed. When averaged across post-ingestion time points, there was a trend (p=0.08) for Ri differences between conditions. The net fluid balance was greater than zero, indicating retention of ingested fluid, for AFstill (p=0.02) and control (p=0.03), with a trend for AFspark (p=0.06). In conclusion, an active formulation containing alpha-cyclodextrin in still water demonstrated potential benefits for enhancing hydration markers in humans.

7.
J Int Soc Sports Nutr ; 20(1): 2211958, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37162193

RESUMEN

BACKGROUND: Thermogenic supplements are often consumed by individuals seeking to improve energy levels and reduce body fat. These supplements are sold in powdered or ready-to-drink (RTD) forms and consist of a blend of ingredients such as caffeine, green tea extract, and other botanical compounds. While there is evidence that thermogenic supplements can positively affect resting energy expenditure (REE), the effect varies based on the combination of active ingredients. Additionally, there is some concern that thermogenic supplements may cause unwanted side effects on hemodynamic variables, like heart rate (HR) and blood pressure (BP). Therefore, further investigation into the efficacy and safety of commercially available products is warranted. METHODS: Twenty-eight individuals (14 F, 14 M; age: 23.3 ± 3.9 yrs; height: 169.4 ± 8.6 cm; body mass: 73.3 ± 13.1 kg) completed two visits in a randomized, double-blind, crossover fashion. Each visit began with baseline REE, HR, and BP assessments, which were followed by ingestion of an active RTD thermogenic beverage (RTD; OxyShred Ultra Energy) or placebo (PL). Assessments were repeated at the intervals of 35-50- and 85-100-minutes post-ingestion. In addition, subjective outcomes of energy, focus, concentration, alertness, and mood were collected five times throughout each visit. Repeated-measures analysis of variance was performed with condition and time specified as within-subjects factors and sex and resistance training (RT) status as between-subjects factors. Statistical significance was accepted at p < 0.05. RESULTS: A significant condition × time interaction was observed for REE (p < 0.001). Higher REE values were demonstrated at 35-50 min (0.08 ± 0.02 kcal/min; p = 0.001; 5.2% difference) and 85-100 min (0.08 ± 0.02 kcal/min; p = 0.001; 5.5% difference) after RTD ingestion as compared to PL. No significant condition × time interactions were observed for respiratory quotient, HR, or BP. Condition main effects indicated lower HR (3.0 ± 0.9 bpm; p = 0.003), higher SBP (3.5 ± 1.1 mm Hg; p = 0.003) and higher DBP (3.5 ± 0.9 mm Hg; p < 0.001) in RTD as compared to PL, irrespective of time. Condition × time interactions were observed for all subjective outcomes (p ≤ 0.02). Post hoc tests indicated statistically significant benefits of the RTD over PL for energy, focus, concentration, and alertness, without significant differences for mood after correction for multiple comparisons. Sex and RT status were not involved in interactions for any outcomes, except for a Sex × RT status interaction for energy, indicating higher energy ratings in non-resistance-trained vs. resistance-trained males. CONCLUSIONS: These data suggest that acute ingestion of a thermogenic RTD beverage significantly increases REE, and this elevated caloric expenditure is sustained for at least 100 minutes following ingestion. Furthermore, the RTD beverage increased measures of energy, focus, concentration, and alertness as compared to placebo. While minor differences in hemodynamic variables were observed between conditions, all values stayed within normal ranges. Individuals aiming to increase energy expenditure may benefit from acute ingestion of an RTD thermogenic supplement.


Asunto(s)
Metabolismo Energético , Hemodinámica , Masculino , Humanos , Adulto Joven , Adulto , Presión Sanguínea , Frecuencia Cardíaca , Bebidas , Método Doble Ciego , Estudios Cruzados
8.
Int J Exerc Sci ; 16(1): 429-447, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37123458

RESUMEN

The purpose of this preliminary analysis was to determine if there are relationships between anthropometric characteristics (arm length, torso length, thigh length, and shank length) and conventional deadlift (CDL) kinematics and kinetics during a 5 sets of 5 repetitions (5 × 5) CDL routine in resistance-trained males. Eleven males who had experience with the deadlift exercise were included in this analysis (age: 21.5 ± 1.4 y; height: 180.7 ± 5.7 cm; body mass: 89.9 ± 16.0 kg). Anthropometrics were measured by a 3-dimensional optical scanner. The participants underwent a 5 × 5 CDL workout using a self-selected load corresponding to a rating of perceived exertion (RPE) of 8 out of 10. Performance outcomes were measured synchronously using a 3-dimensional 12-camera motion capture system and two force platforms. Outcomes were averaged across all sets and analyzed using multiple linear regression. The selected anthropometric variables were not significantly related to the CDL performance outcomes, except for concentric ankle work. However, in the overall model, anthropometric predictors did not significantly predict ankle concentric work (p = 0.11; R 2 = 0.67; R_2adj = 0.45). Independently, thigh length significantly correlated with ankle concentric work (p = 0.03). In this model, thigh length accounted for 55% of the normalized variance in ankle concentric work. The results from this preliminary study suggest that arm length, torso length, and shank length may not play a clear role in the examined CDL outcomes, but thigh length may be positively correlated with ankle concentric work during a 5 × 5 CDL routine in resistance-trained males.

9.
J Int Soc Sports Nutr ; 20(1): 2171314, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36862943

RESUMEN

Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature regarding the effects of energy drink (ED) or energy shot (ES) consumption on acute exercise performance, metabolism, and cognition, along with synergistic exercise-related performance outcomes and training adaptations. The following 13 points constitute the consensus of the Society and have been approved by the Research Committee of the Society: Energy drinks (ED) commonly contain caffeine, taurine, ginseng, guarana, carnitine, choline, B vitamins (vitamins B1, B2, B3, B5, B6, B9, and B12), vitamin C, vitamin A (beta carotene), vitamin D, electrolytes (sodium, potassium, magnesium, and calcium), sugars (nutritive and non-nutritive sweeteners), tyrosine, and L-theanine, with prevalence for each ingredient ranging from 1.3 to 100%. Energy drinks can enhance acute aerobic exercise performance, largely influenced by the amount of caffeine (> 200 mg or >3 mg∙kg bodyweight [BW-1]) in the beverage. Although ED and ES contain several nutrients that are purported to affect mental and/or physical performance, the primary ergogenic nutrients in most ED and ES based on scientific evidence appear to be caffeine and/or the carbohydrate provision. The ergogenic value of caffeine on mental and physical performance has been well-established, but the potential additive benefits of other nutrients contained in ED and ES remains to be determined. Consuming ED and ES 10-60 minutes before exercise can improve mental focus, alertness, anaerobic performance, and/or endurance performance with doses >3 mg∙kg BW-1. Consuming ED and ES containing at least 3 mg∙kg BW-1 caffeine is most likely to benefit maximal lower-body power production. Consuming ED and ES can improve endurance, repeat sprint performance, and sport-specific tasks in the context of team sports. Many ED and ES contain numerous ingredients that either have not been studied or evaluated in combination with other nutrients contained in the ED or ES. For this reason, these products need to be studied to demonstrate efficacy of single- and multi-nutrient formulations for physical and cognitive performance as well as for safety. Limited evidence is available to suggest that consumption of low-calorie ED and ES during training and/or weight loss trials may provide ergogenic benefit and/or promote additional weight control, potentially through enhanced training capacity. However, ingestion of higher calorie ED may promote weight gain if the energy intake from consumption of ED is not carefully considered as part of the total daily energy intake. Individuals should consider the impact of regular coingestion of high glycemic index carbohydrates from ED and ES on metabolic health, blood glucose, and insulin levels. Adolescents (aged 12 through 18) should exercise caution and seek parental guidance when considering the consumption of ED and ES, particularly in excessive amounts (e.g. > 400 mg), as limited evidence is available regarding the safety of these products among this population. Additionally, ED and ES are not recommended for children (aged 2-12), those who are pregnant, trying to become pregnant, or breastfeeding and those who are sensitive to caffeine. Diabetics and individuals with preexisting cardiovascular, metabolic, hepatorenal, and/or neurologic disease who are taking medications that may be affected by high glycemic load foods, caffeine, and/or other stimulants should exercise caution and consult with their physician prior to consuming ED. The decision to consume ED or ES should be based upon the beverage's content of carbohydrate, caffeine, and other nutrients and a thorough understanding of the potential side effects. Indiscriminate use of ED or ES, especially if multiple servings per day are consumed or when consumed with other caffeinated beverages and/or foods, may lead to adverse effects. The purpose of this review is to provide an update to the position stand of the International Society of Sports Nutrition (ISSN) integrating current literature on ED and ES in exercise, sport, and medicine. The effects of consuming these beverages on acute exercise performance, metabolism, markers of clinical health, and cognition are addressed, as well as more chronic effects when evaluating ED/ES use with exercise-related training adaptions.


Asunto(s)
Bebidas Energéticas , Adolescente , Niño , Femenino , Embarazo , Humanos , Cafeína , Vitaminas , Nutrientes , Ácido Ascórbico
10.
Br J Nutr ; 130(5): 827-840, 2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-36404739

RESUMEN

The purpose of this investigation was to expand upon the limited existing research examining the test-retest reliability, cross-sectional validity and longitudinal validity of a sample of bioelectrical impedance analysis (BIA) devices as compared with a laboratory four-compartment (4C) model. Seventy-three healthy participants aged 19-50 years were assessed by each of fifteen BIA devices, with resulting body fat percentage estimates compared with a 4C model utilising air displacement plethysmography, dual-energy X-ray absorptiometry and bioimpedance spectroscopy. A subset of thirty-seven participants returned for a second visit 12-16 weeks later and were included in an analysis of longitudinal validity. The sample of devices included fourteen consumer-grade and one research-grade model in a variety of configurations: hand-to-hand, foot-to-foot and bilateral hand-to-foot (octapolar). BIA devices demonstrated high reliability, with precision error ranging from 0·0 to 0·49 %. Cross-sectional validity varied, with constant error relative to the 4C model ranging from -3·5 (sd 4·1) % to 11·7 (sd 4·7) %, standard error of the estimate values of 3·1-7·5 % and Lin's concordance correlation coefficients (CCC) of 0·48-0·94. For longitudinal validity, constant error ranged from -0·4 (sd 2·1) % to 1·3 (sd 2·7) %, with standard error of the estimate values of 1·7-2·6 % and Lin's CCC of 0·37-0·78. While performance varied widely across the sample investigated, select models of BIA devices (particularly octapolar and select foot-to-foot devices) may hold potential utility for the tracking of body composition over time, particularly in contexts in which the purchase or use of a research-grade device is infeasible.


Asunto(s)
Composición Corporal , Humanos , Reproducibilidad de los Resultados , Impedancia Eléctrica , Estudios Transversales , Absorciometría de Fotón/métodos
11.
Nutrients ; 14(16)2022 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-36014827

RESUMEN

Multivitamin/mineral (MVM) supplements are one of the most popular dietary supplement categories. The purpose of this analysis was to determine if a novel liposomal delivery mechanism improves mineral absorption from an MVM product. In a randomized crossover trial, 25 healthy participants (12 females, 13 males) completed two testing sessions in which blood samples were collected at baseline and 2, 4, and 6 h following the ingestion of either a liposomal MVM or a nutrient-matched standard MVM. Analysis of MVM products indicated an elemental iron content of 9.4 and 10.1 mg (~50% U.S. FDA Daily Value) and an elemental magnesium content of 22.0 and 23.3 mg (~5% U.S. FDA Daily Value) in the liposomal and standard MVM products, respectively. Blood samples were analyzed for concentrations of iron and magnesium using colorimetric assays. Changes in mineral concentrations were analyzed using linear mixed models, and pharmacokinetic parameters were compared between conditions. For iron, statistically significant condition × time interactions were observed for percent change from baseline (p = 0.002), rank of percent change from baseline (p = 0.01), and raw concentrations (p = 0.02). Follow-up testing indicated that the liposomal condition exhibited larger changes from baseline than the standard MVM condition at 4 (p = 0.0001; +14.3 ± 18.5% vs. -6.0 ± 13.1%) and 6 h (p = 0.0002; +1.0 ± 20.9% vs. -21.0 ± 15.3%) following MVM ingestion. These changes were further supported by a 50% greater mean incremental area under the curve in the liposomal condition (33.2 ± 30.9 vs. 19.8 ± 19.8 mcg/dL × 6 h; p = 0.02, Cohen's d effect size = 0.52). In contrast, no differential effects for magnesium absorption were observed. In conclusion, iron absorption from an MVM product is enhanced by a liposomal delivery mechanism.


Asunto(s)
Magnesio , Minerales , Estudios Cruzados , Suplementos Dietéticos , Femenino , Humanos , Hierro , Masculino , Vitaminas
12.
J Electr Bioimpedance ; 13(1): 10-20, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35646197

RESUMEN

This study evaluated the influence of acute water ingestion and maintaining an upright posture on raw bioimpedance and subsequent estimates of body fluids and composition. Twenty healthy adults participated in a randomized crossover study. In both conditions, an overnight food and fluid fast was followed by an initial multi-frequency bioimpedance assessment (InBody 770). Participants then ingested 11 mL/kg of water (water condition) or did not (control condition) during a 5-minute period. Thereafter, bioimpedance assessments were performed every 10 minutes for one hour with participants remaining upright throughout. Linear mixed effects models were used to examine the influence of condition and time on raw bioimpedance, body fluids, and body composition. Water consumption increased impedance of the arms but not trunk or legs. However, drift in leg impedance was observed, with decreasing values over time in both conditions. No effects of condition on body fluids were detected, but total body water and intracellular water decreased by ~0.5 kg over time in both conditions. Correspondingly, lean body mass did not differ between conditions but decreased over the measurement duration. The increase in body mass in the water condition was detected exclusively as fat mass, with final fat mass values ~1.3 kg higher than baseline and also higher than the control condition. Acute water ingestion and prolonged standing exert practically meaningful effects on relevant bioimpedance variables quantified by a modern, vertical multi-frequency analyzer. These findings have implications for pre-assessment standardization, methodological reporting, and interpretation of assessments.

13.
J Strength Cond Res ; 36(8): 2212-2217, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35612943

RESUMEN

ABSTRACT: Brandner, CF, Harty, PS, Luedke, JA, Erickson, JL, and Jagim, AR. Sport differences in fat-free mass index among a diverse sample of NCAA Division III collegiate athletes. J Strength Cond Res 36(8): 2212-2217, 2022-Fat-free mass index (FFMI) is becoming a popular metric to determine an athlete's potential for future fat-free mass accrual or to identify athletes who may be at risk for low fat-free mass (FFM). The aim of the current study was to examine sport-specific differences in FFMI among a cohort of collegiate athletes. NCAA Division III male ( n = 98; age: 20.1 ± 1.6 years, height: 1.82 ± 0.06 m, body mass: 92.7 ± 17.5 kg, %BF: 15.6 ± 8.8%) and female ( n = 92; age: 19.45 ± 1.1 years, height: 1.68 ± 0.06 m, body mass: 65.16 ± 11.04 kg, %BF: 22.71 ± 5.9%) athletes completed a body composition assessment using air displacement plethysmography. Fat-free mass index was calculated by dividing FFM by height squared. The mean ± SD FFMI was significantly higher ( p < 0.05) for males (23.37 ± 2.41 kg·m -2 ) compared with females (17.54 ± 1.8 kg·m -2 ). There was a significant main effect for sport category. Post hoc analysis indicated that throwers had a higher ( p < 0.001) FFMI (mean difference, 95% confidence interval) compared with sprinters and soccer athletes (4.17, 2.03-6.32 kg·m -2 ), endurance and weight-sensitive athletes (4.91, 2.67-7.14 kg·m -2 ), and court sport athletes (4.39, 1.97-6.81 kg·m -2 ), respectively, among female athletes. Post hoc analysis indicated that football players had a higher ( p < 0.01) FFMI than distance runners (3.89, 2.15, 5.62) and wrestlers (2.23, 0.78, 3.68), among male athletes. These findings indicate that sex differences in FFMI exist, with differences identified between sports. These findings can guide strength and nutritional programming decisions by providing sport-specific normative data profiles.


Asunto(s)
Atletas , Deportes , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Absorciometría de Fotón , Composición Corporal , Pletismografía
14.
J Int Soc Sports Nutr ; 19(1): 126-149, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35599920

RESUMEN

Background: There is substantial consumer and practitioner interest in an emerging supplement class known as multi-ingredient pre-workout supplements (MIPS), largely due to their prevalence in resistance training communities as well as research findings demonstrating the ergogenic impact of caffeine on muscular performance. However, limited research has examined the potential efficacy of non-caffeinated MIPS, despite their growing popularity among those who are caffeine-sensitive or who train later in the day. Methods: Twenty-four resistance-trained college-aged males (n = 12) and females (n = 12) completed three visits in which they ingested either a caffeinated MIPS (C), an otherwise identical non-caffeinated MIPS (NC), or placebo in a double-blind, counterbalanced, crossover fashion. Squat isometric peak force (PFiso), rate of force development (RFD), and isokinetic performance were assessed. Upper and lower body maximal muscular strength and endurance were evaluated using the bench press and leg press, respectively. Visual analog scales for energy, focus, and fatigue were completed five times throughout the testing protocol. The effects of supplementation and biological sex on all variables were examined using linear mixed effects models. Results: Significantly greater PFiso was observed in both C (b: 0.36 transformed units [0.09, 0.62]) and NC (b: 0.32 transformed units [95% CI: 0.05, 0.58]) conditions, relative to placebo. Early RFD (RFD50) may have been higher with supplementation, particularly in females, with no effects for late RFD (RFD200) or peak RFD. In addition, increases in subjective energy after supplement ingestion were noted for C, but not NC. No effects of supplementation on traditional resistance exercise performance or isokinetic squat performance were observed, other than a lower leg press one-repetition maximum for males in the NC condition. Conclusions: These data indicate that acute ingestion of either a caffeinated or non-caffeinated pre-workout formulation improved maximal force production during an isometric squat test but did not provide additional benefit to leg press, bench press, or isokinetic squat performance over placebo, within the context of a laboratory environment. The consumption of a caffeinated, but not non-caffeinated, MIPS increased subjective ratings of energy over placebo when assessed as part of a testing battery.


Asunto(s)
Sustancias para Mejorar el Rendimiento , Entrenamiento de Fuerza , Cafeína/farmacología , Suplementos Dietéticos , Método Doble Ciego , Femenino , Humanos , Masculino , Fuerza Muscular , Sustancias para Mejorar el Rendimiento/farmacología , Entrenamiento de Fuerza/métodos , Fenómenos Fisiológicos en la Nutrición Deportiva , Adulto Joven
15.
Nutr Rev ; 80(3): 439-452, 2022 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-35142356

RESUMEN

Intermittent fasting (IF) is a dietary strategy that involves alternating periods of abstention from calorie consumption with periods of ad libitum food intake. There is significant interest in the body of literature describing longitudinal adaptations to IF. Less attention has been given to the acute physiological responses that occur during the fasting durations that are commonly employed by IF practitioners. Thus, the purpose of this review was to examine the physiological responses - including alterations in substrate metabolism, systemic hormones, and autophagy - that occur throughout an acute fast. Literature searches were performed to locate relevant research describing physiological responses to acute fasting and short-term starvation. A single fast demonstrated the ability to alter glucose and lipid metabolism within the initial 24 hours, but variations in protein metabolism appeared to be minimal within this time frame. The ability of an acute fast to elicit significant increases in autophagy is still unknown. The information summarized in this review can be used to help contextualize existing research and better inform development of future IF interventions.


Asunto(s)
Ingestión de Energía , Ayuno , Glucemia , Dieta , Ayuno/fisiología , Glucosa , Humanos , Metabolismo de los Lípidos
16.
Nutrients ; 14(2)2022 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-35057494

RESUMEN

BACKGROUND: Energy drinks are one of the most popular packaged beverage products consumed within the United States (US). Energy drinks are considered a functional beverage, a category that also includes sports drinks and nutraceutical beverages. PURPOSE: The focus of the current study was to examine the nutrition fact panels of the top selling commercially available energy drink and energy shot products within the US to characterize common ingredient profiles to help establish a standard definition and ingredient profile of energy drinks and energy shots for consumers, health care practitioners, and researchers. METHODS: The top 75 commercially available energy drinks and shots were identified and compiled from multiple commercial retail websites as of September 2021. For the purpose of this study, an energy drink must have met the following criteria: (A) marketed as an energy drink; (B) purported to improve energy, focus, or alertness; (C) not sold as a dietary supplement (no supplement fact panels); (D) manufactured as a pre-packaged and ready-to-drink beverage; and (E) contains at least three of (1) caffeine, (2) B-vitamins, (3) sugar, (4) taurine, (5) creatine, (6) quercetin, (7) guarana, (8) ginseng, (9) coenzyme Q10, or (10) branched chain amino acids. Energy shots must have met similar criteria to be included: (A) marketed as an energy shot; (B) purported to improve energy, focus, or alertness; (C) sold as a dietary supplement; (D) manufactured as a pre-packaged beverage with a small volume (<3.5 mL); and (E) contains at least three of the ingredients stated above. RESULTS: Twenty energy shots and fifty-five energy drinks were included in this analysis. The number of ingredients per product (mean ± SD) was 18.2 ± 5.7, with 15 products containing proprietary blends with undisclosed ingredient amounts. The relative prevalence and average amounts of the top ingredients were as follows: caffeine (100%; 174.4 ± 81.1 mg), vitamin B6 (72%; 366.9 ± 648.1 percent daily value (%DV)), vitamin B3 (67%; 121.44 ± 69.9% DV), vitamin B12 (67%; 5244.5 ± 10,474.6% DV), vitamin B5 (37.3%; 113.6 ± 76.6% DV), and taurine (37.3%; amounts undisclosed). CONCLUSIONS: Our findings suggest a high prevalence of caffeine and B-vitamins in these energy products, with many of the formulations containing well above the recommended daily value of B-vitamins.


Asunto(s)
Cafeína/análisis , Bebidas Energéticas/análisis , Etiquetado de Alimentos , Taurina/análisis , Complejo Vitamínico B/análisis , Estados Unidos , Vitaminas
17.
J Strength Cond Res ; 36(11): 3093-3104, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34172636

RESUMEN

ABSTRACT: Rodriguez, C, Harty, PS, Stratton, MT, Siedler, MR, Smith, RW, Johnson, BA, Dellinger, JR, Williams, AD, White, SJ, Benavides, ML, and Tinsley, GM. Comparison of indirect calorimetry and common prediction equations for evaluating changes in resting metabolic rate induced by resistance training and a hypercaloric diet. J Strength Cond Res 36(11): 3093-3104, 2022-The ability to accurately identify resting metabolic rate (RMR) changes over time allows practitioners to prescribe appropriate adjustments to nutritional intake. However, there is a lack of data concerning the longitudinal utility of commonly used RMR prediction equations. The purpose of this study was to evaluate the validity of several commonly used prediction equations to track RMR changes during a hypercaloric nutritional intervention and supervised resistance exercise training program. Twenty resistance-trained men completed the study. The protocol lasted 6 weeks, and subjects underwent RMR assessments by indirect calorimetry (IC) preintervention and postintervention to obtain reference values. Existing RMR prediction equations based on body mass (BM) or dual-energy X-ray absorptiometry fat-free mass (FFM) were also evaluated. Equivalence testing was used to evaluate whether each prediction equation demonstrated equivalence with IC. Null hypothesis significance testing was also performed, and Bland-Altman analysis was used alongside linear regression to assess the degree of proportional bias. Body mass and FFM increased by 3.6 ± 1.7 kg and 2.4 ± 1.6 kg, respectively. Indirect calorimetry RMR increased by 165 ± 97 kcal·d -1 , and RMR:FFM increased by 5.6 ± 5.2%. All prediction equations underestimated mean RMR changes relative to IC, with magnitudes ranging from 75 to 155 kcal·d -1 , while also displaying unacceptable levels of negative proportional bias. In addition, no equation demonstrated equivalence with IC. Common RMR prediction equations based on BM or FFM did not fully detect the increase in RMR observed with resistance training plus a hypercaloric diet. Overall, the evaluated prediction equations are unsuitable for estimating RMR changes in the context of this study.


Asunto(s)
Metabolismo Basal , Entrenamiento de Fuerza , Masculino , Humanos , Calorimetría Indirecta/métodos , Absorciometría de Fotón , Dieta , Composición Corporal
18.
J Strength Cond Res ; 36(12): 3551-3561, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34593729

RESUMEN

ABSTRACT: Harty, PS, Friedl, KE, Nindl, BC, Harry, JR, Vellers, HL, and Tinsley, GM. Military body composition standards and physical performance: historical perspectives and future directions. J Strength Cond Res 36(12): 3551-3561, 2022-US military physique and body composition standards have been formally used for more than 100 years. These metrics promote appropriate physical fitness, trim appearance, and long-term health habits in soldiers, although many specific aspects of these standards have evolved as evidence-based changes have emerged. Body composition variables have been shown to be related to many physical performance outcomes including aerobic capacity, muscular endurance, strength and power production, and specialized occupational tasks involving heavy lifting and load carriage. Although all these attributes are relevant, individuals seeking to improve military performance should consider emphasizing strength, hypertrophy, and power production as primary training goals, as these traits appear vital to success in the new Army Combat Fitness Test introduced in 2020. This fundamental change in physical training may require an adjustment in body composition standards and methods of measurement as physique changes in modern male and female soldiers. Current research in the field of digital anthropometry (i.e., 3-D body scanning) has the potential to dramatically improve performance prediction algorithms and potentially could be used to inform training interventions. Similarly, height-adjusted body composition metrics such as fat-free mass index might serve to identify normal weight personnel with inadequate muscle mass, allowing for effective targeted nutritional and training interventions. This review provides an overview of the origin and evolution of current US military body composition standards in relation to military physical readiness, summarizes current evidence relating body composition parameters to aspects of physical performance, and discusses issues relevant to the emerging modern male and female warrior.


Asunto(s)
Personal Militar , Masculino , Femenino , Humanos , Aptitud Física/fisiología , Composición Corporal/fisiología , Prueba de Esfuerzo/métodos , Estatura , Fuerza Muscular/fisiología , Resistencia Física/fisiología
19.
Br J Nutr ; 127(11): 1656-1674, 2022 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-34325758

RESUMEN

The present study reports the validity of multiple assessment methods for tracking changes in body composition over time and quantifies the influence of unstandardised pre-assessment procedures. Resistance-trained males underwent 6 weeks of structured resistance training alongside a hyperenergetic diet, with four total body composition evaluations. Pre-intervention, body composition was estimated in standardised (i.e. overnight fasted and rested) and unstandardised (i.e. no control over pre-assessment activities) conditions within a single day. The same assessments were repeated post-intervention, and body composition changes were estimated from all possible combinations of pre-intervention and post-intervention data. Assessment methods included dual-energy X-ray absorptiometry (DXA), air displacement plethysmography, three-dimensional optical imaging, single- and multi-frequency bioelectrical impedance analysis, bioimpedance spectroscopy and multi-component models. Data were analysed using equivalence testing, Bland-Altman analysis, Friedman tests and validity metrics. Most methods demonstrated meaningful errors when unstandardised conditions were present pre- and/or post-intervention, resulting in blunted or exaggerated changes relative to true body composition changes. However, some methods - particularly DXA and select digital anthropometry techniques - were more robust to a lack of standardisation. In standardised conditions, methods exhibiting the highest overall agreement with the four-component model were other multi-component models, select bioimpedance technologies, DXA and select digital anthropometry techniques. Although specific methods varied, the present study broadly demonstrates the importance of controlling and documenting standardisation procedures prior to body composition assessments across distinct assessment technologies, particularly for longitudinal investigations. Additionally, there are meaningful differences in the ability of common methods to track longitudinal body composition changes.


Asunto(s)
Composición Corporal , Humanos , Masculino , Impedancia Eléctrica , Reproducibilidad de los Resultados , Antropometría/métodos , Absorciometría de Fotón/métodos
20.
Clin Physiol Funct Imaging ; 41(6): 514-522, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34549507

RESUMEN

The present study examined cross-sectional and longitudinal relationships between total and segmental subcutaneous tissue thicknesses from ultrasonography (US) and total and segmental fat mass (FM) estimates from dual-energy X-ray absorptiometry (DXA). Traditional US FM estimates were also examined. Twenty resistance-trained males (mean ± SD; age: 22.0 ± 2.6 years; body mass: 74.8 ± 11.5 kg; DXA fat: 17.5 ± 4.5%) completed a 6-week supervised resistance training programme while consuming a hypercaloric diet. Pre- and post-intervention body composition was assessed by DXA and B-mode US. Data were analysed using Pearson's correlation (r), Lin's correlation coefficient (CCC), paired t-tests, Wilcoxon signed-rank tests and Bland-Altman analysis, as appropriate. Cross-sectionally, correlations were observed between total DXA FM and total subcutaneous tissue thickness (r = 0.88). Longitudinally, a correlation was observed between total DXA FM changes and total subcutaneous tissue changes (r = 0.49, CCC = 0.38). Correlations of similar magnitudes were observed for the upper body and trunk estimates, but DXA FM changes were unrelated to subcutaneous tissue changes for the lower body and arms. Cross-sectionally, US 2-compartment FM and DXA FM were correlated (r = 0.91, CCC = 0.83). Longitudinally, a weaker correlation was observed (r = 0.47, CCC = 0.33). In summary, longitudinal associations between US and DXA are weaker than cross-sectional relationships; additionally, correlations between US subcutaneous tissue and whole-body DXA FM appear to be driven by the trunk region rather than appendages. Reporting raw skinfold thicknesses rather than FM estimates alone may improve the utility of techniques based on subcutaneous tissue thickness, such as US and skinfolds.


Asunto(s)
Tejido Adiposo , Composición Corporal , Absorciometría de Fotón , Adulto , Impedancia Eléctrica , Humanos , Masculino , Grosor de los Pliegues Cutáneos , Grasa Subcutánea/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...