Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Can Assoc Radiol J ; : 8465371241268426, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39239934

RESUMEN

Purpose: Peripartum cardiomyopathy (PPCM) affects women in late pregnancy and postpartum. Cardiovascular magnetic resonance (CMR) can contribute to PPCM diagnosis and management. We explored CMR findings in PPCM, including myocardial strain and late gadolinium enhancement (LGE) patterns. Materials and Methods: This retrospective single-centre study included patients with PPCM who underwent CMR from 2010 to 2018. Exclusions were other cardiomyopathy causes. CMR parameters, including ventricular function, LGE, and myocardial strain, were compared between the PPCM group and healthy controls. Transthoracic echocardiographic data were reviewed to assess functional improvement in PPCM patients. Results: Thirty-two women with PPCM (mean age 42 ± 6 years) and 26 controls (mean age 43 ± 14 years) were included. PPCM patients had significantly lower left ventricular (LV) ejection fractions (median 37.5% vs 60.5%, P < .001), higher LV end-diastolic volumes (median 108 ml/m² vs 76 ml/m², P < .001), and reduced global LV strain compared to controls. Eighteen PPCM patients (58%) had non-ischaemic pattern LGE, with no LGE in controls besides hingepoint LGE (23%). LGE was most prevalent in the basal and mid anteroseptum. LGE patterns included linear mid-wall, subepicardial, and right ventricular side of the septum. Twenty-four patients (92%) showed improvement in LVEF at follow-up echocardiogram (mean LVEF 28% ± 1.9% at diagnosis and 45% ± 3% at follow-up, P < .001). Conclusion: We identified a non-ischaemic pattern LGE that is nonspecific in isolation but could suggest PPCM in the correct clinical context along with abnormal CMR strain values. Future studies should evaluate the clinical application of these findings to facilitate earlier diagnosis and enhance management.

2.
BMC Cardiovasc Disord ; 24(1): 254, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750460

RESUMEN

INTRODUCTION: The aim of this study is to analyze the diagnostic value of global longitudinal strain (GLS) in detecting inducible myocardial ischemia in patients with chest pain undergoing treadmill contrast-enhanced stress echocardiography (SE). METHODS: We retrospectively enrolled all patients who underwent invasive coronary angiography after treadmill contrast-enhanced SE. Rest and peak-stress myocardial GLS, segmental LS, and LS of 4-chamber (CH), 2-CH, and 3-CH views were reported. Luminal stenosis of more than 70% or fractional flow reserve (FFR) of < 0.8 was considered significant. RESULTS: In total 33 patients were included in the final analysis, among whom sixteen patients (48.4%) had significant coronary artery stenosis. Averaged GLS, 3-CH, and 4-CH LS were significantly lower in patients with critical coronary artery stenosis compared to those without significant stenosis (-17.1 ± 7.1 vs. -24.2 ± 7.2, p = 0.041), (-18.2 ± 8.9 vs. -24.6 ± 8.2, p = 0.045) and (-14.8 ± 6.2 vs. -22.8 ± 7.8, p = 0.009), respectively. Receiver operating characteristic (ROC) analysis of ischemic and non-ischemic segments demonstrated that a cut-off value of -20% of stress LS had 71% sensitivity and 60% specificity for ruling out inducible myocardial ischemia (Area under the curve was AUC = 0.72, P < 0.0001). CONCLUSION: Myocardial LS measured with treadmill contrast-enhanced stress echocardiography demonstrates potential value in identifying patients with inducible myocardial ischemia.


Asunto(s)
Medios de Contraste , Angiografía Coronaria , Estenosis Coronaria , Ecocardiografía de Estrés , Valor Predictivo de las Pruebas , Humanos , Masculino , Femenino , Ecocardiografía de Estrés/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Medios de Contraste/administración & dosificación , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Reproducibilidad de los Resultados , Contracción Miocárdica , Función Ventricular Izquierda , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico
4.
Front Cardiovasc Med ; 8: 706123, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722653

RESUMEN

Concomitant tricuspid regurgitation (TR) is common in patients with mitral regurgitation (MR). While current guidelines recommend repair of both valves at the time of surgery when feasible, high risk patients are often undertreated, leading to significant morbidity and mortality. With advances in transcatheter edge-to-edge repair (TEER) devices and technique, combined TEER for treating significant MR and TR has emerged as a new tool for heart failure management. Recent evidence has shed light on which patients with severe TR should be targeted for transcatheter intervention either in isolation or in combination with a MV TEER procedure and allows for expanded treatment options in patients who otherwise would be limited to medical management. Technological advancements remain ahead of robust clinical data, and thus randomized clinical studies in patients with severe MR and TR will be instrumental in determining the best approach in treating these patients with transcatheter therapies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA