1.
BMC Musculoskelet Disord ; 21(1): 599, 2020 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-32900364

RESUMEN

BACKGROUND: Concerns have been raised that implants used in total hip replacements (THR) could lead to increased cancer risk. Several different materials, metals and fixation techniques are used in joint prostheses and different types of articulation can cause an increased invasion of particles or ions into the human body. METHODS: Patients with THR registered in the Norwegian Arthroplasty Register during 1987-2009 were linked to the Cancer registry of Norway. Patients with THR due to osteoarthritis, under the age of 75 at time of surgery, were included. Standardized incidence ratios (SIR) were applied to compare cancer risk for THR patients to the general population. Types of THR were divided into cemented (both components), uncemented (both components), and hybrid (cemented femoral and uncemented acetabular components). To account for selection mechanisms, time dependent covariates were applied in Cox-regression, adjusting for cancer risk the first 10 years after surgery. The analyses were adjusted for age, gender and if the patient had additional THR-surgery in the same or the opposite hip. The study follows the STROBE guidelines. RESULTS: Comparing patients with THR to the general population in Norway we found no differences in cancer risk. The overall SIR for the THR-patients after 10 years follow-up was 1.02 (95% CI: 0.97-1.07). For cemented THR, the SIR after 10 years follow-up was 0.99 (95% CI: 0.94-1.05), for uncemented, 1.16 (95% CI: 1.02-1.30), and for hybrid 1.12 (95% CI: 0.91-1.33). Adjusted Cox analyses showed that patients with uncemented THRs had an elevated risk for cancer (hazard ratio: HR = 1.24, 95% CI: 1.05-1.46, p = 0.009) when compared to patients with cemented THRs after 10 years follow-up. Stratified by gender the increased risk was only present for men. The risk for patients with hybrid THRs was not significantly increased (HR = 1.07, 95% CI: 0.85-1.35, p = 0.55) compared to patients with cemented THRs. CONCLUSIONS: THR patients had no increased risk for cancer compared to the general population. We found, however, that receiving an uncemented THR was associated with a small increased risk for cancer compared to cemented THR in males, but that this may be prone to unmeasured confounding.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Neoplasias , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Masculino , Neoplasias/diagnóstico , Neoplasias/epidemiología , Noruega/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación
2.
J Bone Joint Surg Am ; 101(2): 169-176, 2019 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-30653047

RESUMEN

BACKGROUND: The dual mobility acetabular cup (DMC) was designed to reduce prosthetic instability and has gained popularity for both primary and revision total hip arthroplasty (THA). We compared the risk of revision of primary THA for primary osteoarthritis between patients treated with a DMC and those who received a metal-on-polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearing. METHODS: A search of the Nordic Arthroplasty Register Association (NARA) database identified THAs performed with a DMC during 1995 to 2013. With use of propensity score matching, 2,277 of these patients were matched (1:1), with regard to sex, age, component fixation, and year of surgery, with patients with an MoP or CoP bearing. We estimated the cumulative incidence of revision taking death as a competing risk into consideration and performed competing risk regression with revision or death as end points. RESULTS: There was no difference in the overall risk of revision between the DMC group and the propensity-score-matched MoP/CoP group (adjusted hazard ratio [HR] = 1.18; 95% confidence interval [95% CI] = 0.87 to 1.62). Patients with a DMC bearing had a lower risk of revision due to dislocation (adjusted HR = 0.09; 95% CI = 0.03 to 0.29) but a higher risk of revision caused by infection (adjusted HR = 3.20; 95% CI = 1.49 to 6.85). CONCLUSIONS: There was no difference in overall risk of revision between the DMC and MoP/CoP groups. The DMCs protected against revision due to dislocation but THAs performed with this bearing were more commonly revised because of infection. There may have been a selection bias toward placing DMC implants in patients with greater frailty as the mortality rates were higher in the DMC group than in the age and sex-matched MoP/CoP group. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/estadística & datos numéricos , Osteoartritis/cirugía , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
3.
BMC Musculoskelet Disord ; 18(1): 544, 2017 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-29268748

RESUMEN

BACKGROUND: The aim of this study was to assess which patient and procedure factors affected both the risk of infection as well as procedure duration. Additionally, to assess if procedure duration affected the revision risk due to deep infection in total knee arthroplasty (TKA) patients and in a subgroup of low-risk patients. METHODS: 28,262 primary TKA with 311 revisions due to deep infection were included from the Norwegian Arthroplasty Register (NAR) and analysed from primary surgery from 2005 until 31st December 2015 with a 1 and 4 year follow up. The risk of revision due to deep infection was calculated in a multivariable Cox regression model including patient and procedure related risk factors, assessing Hazard Ratio (HR) with 95% confidence interval (CI). RESULTS: Multivariate analysis showed statistically significant associations with revision due to deep infection and increased procedure duration for male patients, ASA3+ (American Society of Anesthesiologists) and perioperative complications. Procedure duration ≥110 min (75 percentile) had a higher risk of deep infection compared to duration <75 min (25 percentile), in the unadjusted analysis (HR = 1.8, 95% CI 1.3-2.5, p = 0.001) and in the adjusted analysis (HR = 1.5, 95% CI 1.0-2.1, p = 0.03). For low-risk patients, procedure duration did not increase the risk of infection. CONCLUSION: Male patients, ASA 3+ patients and perioperative complications were risk factors both for longer procedure duration and for deep infection revisions. Patients with a high degree of comorbidity, defined as ASA3+, are at risk of infection with longer procedure durations. The occurrence of perioperative complications potentially leading to a more complex and lengthy procedure was associated with a higher risk of infection. Long procedure duration in itself seems to have minor impact on infection since we found no association in the low-risk patient.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/tendencias , Tempo Operativo , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Reoperación/tendencias , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/tendencias , Falla de Prótesis/tendencias , Estudios Retrospectivos , Factores de Riesgo
4.
BMC Musculoskelet Disord ; 18(1): 388, 2017 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-28882132

RESUMEN

BACKGROUND: High procedure volume and dedication to unicompartmental knee arthroplasty (UKA) has been suggested to improve revision rates. This study aimed to quantify the annual hospital volume effect on revision risk in Oxfordu nicompartmental knee arthroplasty in the Nordic countries. METHODS: 14,496 cases of cemented medial Oxford III UKA were identified in 126 hospitals in the four countries included in the Nordic Arthroplasty Register Association (NARA) database from 2000 to 2012. Hospitals were divided by quartiles into 4 annual procedure volume groups (≤11, 12-23, 24-43 and ≥44). The outcome was revision risk after 2 and 10 years calculated using Kaplan Meier method. Multivariate Cox regression analysis was used to assess the Hazard Ratio (HR) of any revision due to specific reasons with 95% confidence intervals (CI). RESULTS: The implant survival was 80% at 10 years in the volume group ≤11 procedures per year compared to 83% in other volume groups. The HR adjusted for age category, sex, year of surgery and nation was 0.87 (95% CI: 0.76-0.99, p = 0.036) for the group 12-23 procedures per year, 0.78 (95% CI: 0.68-0.91, p = 0.002) for the group 24-43 procedures per year and 0.82 (95% CI: 0.70-0.94, p = 0.006) for the group ≥44 procedures per year compared to the low volume group. Log-rank test was p = 0.003. The risk of revision for unexplained pain was 40-50% higher in the low compared with other volume groups. CONCLUSION: Low volume hospitals performing ≤11 Oxford III UKAs per year were associated with an increased risk of revision compared to higher volume hospitals, and unexplained pain as revision cause was more common in low volume hospitals.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/tendencias , Hospitales de Alto Volumen/tendencias , Hospitales de Bajo Volumen/tendencias , Prótesis de la Rodilla/tendencias , Reoperación/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Capacidad de Camas en Hospitales , Humanos , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Países Escandinavos y Nórdicos/epidemiología
5.
Acta Orthop ; 88(5): 505-511, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28681677

RESUMEN

Background and purpose - The operative treatment of hip fractures in Norway has changed considerably during the last decade. We used data in the Norwegian Hip Fracture Register to investigate possible effects of these changes on reoperations and 1-year mortality. Patients and methods - 72,741 femoral neck (FFN) fractures and trochanteric fractures in patients 60 years or older were analyzed. The fractures were divided into 5 time periods (2005-2006, 2007-2008, 2009-2010, 2011-2012, 2013-2014). Cox regression models were used to calculate unadjusted and adjusted (age group, sex, and ASA class) relative risks (RRs) of reoperation and of 1-year mortality in the different time periods. Results - For undisplaced FFNs treatment with hemiarthroplasty increased from 2.1% to 9.7% during the study period. For displaced FFNs treatment with arthroplasty increased from 56% to 93%. The use of intramedullary nails increased from 9.1% to 26% for stable 2-fragment (AO/OTA A1) trochanteric fractures, from 15% to 33% for multifragment (AO/OTA A2) trochanteric fractures, and from 27% to 61% for intertrochanteric fractures (AO/OTA A3)/subtrochanteric fractures. Compared with the first time period the adjusted 1-year RR for reoperation was 0.43 (95% CI: 0.37-0.49) for displaced FFNs in the last time period. The adjusted 1-year mortality in the last time period was lower for all fractures (RR: 0.87 (0.83-0.91)), displaced FFNs (RR: 0.86 (0.80-0.93)), AO/OTA A1 trochanteric fractures (RR: 0.79 (0.71-0.88)), and AO/OTA A2 trochanteric fractures (RR: 0.87 (0.77-0.98)) when compared with the first study period. Interpretation - Hip fracture treatment in Norway has improved: The risk of reoperation and the 1-year mortality after displaced femoral neck fractures have decreased over a 10-year period. National registration is useful to monitor trends in treatment and outcomes after hip fractures.


Asunto(s)
Fracturas de Cadera/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Femenino , Fracturas del Cuello Femoral/mortalidad , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/estadística & datos numéricos , Fracturas de Cadera/mortalidad , Humanos , Masculino , Noruega/epidemiología , Modelos de Riesgos Proporcionales , Mejoramiento de la Calidad/estadística & datos numéricos , Sistema de Registros , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
6.
J Bone Joint Surg Am ; 99(10): 840-847, 2017 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-28509824

RESUMEN

BACKGROUND: Since 2008, there has been an increase in the use of minimally invasive surgery (MIS) through an anterior or anterolateral approach for total hip arthroplasty (THA) in Norway. We compared the MIS approaches with the conventional posterior and direct lateral approaches in terms of revision rates and risk of revision. METHODS: On the basis of data in the Norwegian Arthroplasty Register, 21,860 THAs with an uncemented stem, performed between 2008 and 2013, were identified and included in the cohort. Of these THAs, 2,017 were done through an MIS anterior approach; 2,087, through an MIS anterolateral approach; 5,961, through a posterior approach; and 11,795, through a direct lateral approach. Follow-up ended on December 31, 2015. Two and 5-year survival rates were calculated using Kaplan-Meier survival analysis. Relative risk (RR) was calculated using Cox regression analysis, with adjustment for age, sex, primary diagnosis, American Society of Anesthesiologists (ASA) grade, femoral head size, cup fixation, type of articulation, and duration of surgery and using 6 revision end points based on cause: any cause, infection, dislocation, femoral fracture, aseptic loosening, and other/unknown cause. The median duration of follow-up was 4.3 years. RESULTS: There were no significant differences among the surgical approaches with regard to the 2 and 5-year survival rates or RR of revision due to any cause. The RR of revision due to infection was 0.53 (95% confidence interval [CI] = 0.36 to 0.80, p = 0.002) for the MIS anterior and anterolateral approaches and 0.57 (95% CI = 0.40 to 0.80, p = 0.001) for the posterior approach compared with the direct lateral approach. The RR of revision due to dislocation was 2.1 (95% CI = 1.5 to 3.1, p < 0.001) for the posterior approach compared with the direct lateral approach but no significant difference in risk was found when the MIS anterior and anterolateral approaches were compared with the direct lateral approach (RR = 0.71, 95% CI = 0.40 to 1.3, p = 0.25). CONCLUSIONS: The revision rates and risk of revision associated with the MIS anterior and anterolateral approaches were not increased compared with those of the conventional posterior and direct lateral approaches. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Procedimientos Quirúrgicos Mínimamente Invasivos/estadística & datos numéricos , Falla de Prótesis , Sistema de Registros/estadística & datos numéricos , Reoperación/estadística & datos numéricos , Prótesis de Cadera/estadística & datos numéricos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Noruega/epidemiología , Factores de Riesgo
7.
Acta Orthop ; 88(4): 363-369, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28375671

RESUMEN

Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Using the Nordic Arthroplasty Register Association (NARA) database, we identified cup and liner designs where either XLPE or CPE had been used in more than 500 THAs performed for primary hip osteoarthritis. We assessed risk of revision for any reason and for aseptic loosening using Cox regression adjusted for age, sex, femoral head material and size, surgical approach, stem fixation, and presence of hydroxyapatite coating (uncemented cups). Results - The CPE version of the ZCA cup had a risk of revision for any reason similar to that of the XLPE version (p = 0.09), but showed a 6-fold higher risk of revision for aseptic loosening (p < 0.001). The CPE version of the Reflection All Poly cup had an 8-fold elevated risk of revision for any reason (p < 0.001) and a 5-fold increased risk of revision for aseptic loosening (p < 0.001). The Charnley Elite Ogee/Marathon cup and the Trilogy cup did not show such differences. Interpretation - Whether XLPE has any advantage over CPE regarding revision risk may depend on the properties of the polyethylene materials being compared, as well as the respective cup designs, fixation type, and follow-up times. Further research is needed to elucidate how cup design factors interact with polyethylene type to affect the risk of revision.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Dinamarca/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Noruega/epidemiología , Polietileno , Falla de Prótesis , Sistema de Registros , Reoperación/estadística & datos numéricos , Factores de Riesgo , Suecia/epidemiología , Resultado del Tratamiento , Adulto Joven
8.
Acta Orthop ; 88(3): 248-254, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28095724

RESUMEN

Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty Register Association (NARA) has already published 2 papers describing results of reverse hybrid THAs in different age groups. Based on data collected over 2 additional years, we wanted to perform in depth analyses of not only the reverse hybrid concept but also of the different cup/stem combinations used. Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk of revision. The main endpoint was revision for any reason. We also performed specific analyses regarding the different reasons for revision and analyses regarding the cup/stem combinations used in more than 500 cases. Results - We found a higher rate of revision for reverse hybrids than for cemented THAs, with an adjusted relative risk of revision (RR) of 1.4 (95% CI: 1.3-1.5). At 10 years, the survival rate was 94% (CI: 94-95) for cemented THAs and 92% (95% CI: 92-93) for reverse hybrids. The results for the reverse hybrid THAs were inferior to those for cemented THAs in patients aged 55 years or more (RR =1.1, CI: 1.0-1.3; p < 0.05). We found a higher rate of early revision due to periprosthetic femoral fracture for reverse hybrids than for cemented THAs in patients aged 55 years or more (RR =3.1, CI: 2.2-4.5; p < 0.001). Interpretation - Reverse hybrid THAs had a slightly higher rate of revision than cemented THAs in patients aged 55 or more. The difference in survival was mainly caused by a higher incidence of early revision due to periprosthetic femoral fracture in the reversed hybrid THAs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementación/métodos , Prótesis de Cadera , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Cementación/efectos adversos , Femenino , Fracturas del Fémur/epidemiología , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/epidemiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/cirugía , Diseño de Prótesis , Falla de Prótesis/etiología , Sistema de Registros , Reoperación/estadística & datos numéricos , Factores de Riesgo , Países Escandinavos y Nórdicos/epidemiología
9.
Acta Orthop ; 88(1): 75-81, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27841713

RESUMEN

Background and purpose - The bone cement market for total knee arthroplasty (TKA) in Norway has been dominated by a few products and distributors. Palacos with gentamicin had a market share exceeding 90% before 2005, but it was then withdrawn from the market and replaced by new slightly altered products. We have compared the survival of TKAs fixated with Palacos with gentamicin with the survival of TKAs fixated with the bone cements that took over the market. Patients and methods - Using data from the Norwegian Arthroplasty Register for the period 1997-2013, we included 26,147 primary TKAs in the study. The inclusion criteria were TKAs fixated with the 5 most used bone cements and the 5 most common total knee prostheses for that time period. 6-year Kaplan-Meier survival probabilities were established for each cement product. The Cox proportional hazards regression model was used to assess the association between bone cement product and revision risk. Separate analyses were performed with revision for any reason and revision due to deep infection within 1 year postoperatively as endpoints. Adjustments were made for age, sex, diagnosis, and prosthesis brand. Results - Survival was similar for the prostheses in the follow-up period, between the 5 bone cements included: Palacos with gentamicin, Refobacin Palacos R, Refobacin Bone Cement R (Refobacin BCR), Optipac Refobacin Bone Cement R (Optipac Refobacin BCR), and Palacos R + G. Interpretation - According to our findings, the use of the new bone cements led to a survival rate that was as good as with the old bone cement (Palacos with gentamicin).


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Prótesis de la Rodilla , Anciano , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Noruega/epidemiología , Diseño de Prótesis , Falla de Prótesis/tendencias , Estudios Retrospectivos , Factores de Tiempo
10.
Acta Orthop ; 88(1): 29-34, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27805460

RESUMEN

Background and purpose - Hemiarthroplasty (HA) is the most common treatment for displaced femoral neck fractures in many countries. In Norway, there has been a tradition of using the direct lateral surgical approach, but worldwide a posterior approach is more often used. Based on data from the Norwegian Hip Fracture Register, we compared the results of HA operated through the posterior and direct lateral approaches regarding patient-reported outcome measures (PROMs) and reoperation rate. Patients and methods - HAs due to femoral neck fracture in patients aged 60 years and older were included from the Norwegian Hip Fracture Register (2005-2014). 18,918 procedures were reported with direct lateral approach and 1,990 with posterior approach. PROM data (satisfaction, pain, quality of life (EQ-5D), and walking ability) were reported 4, 12, and 36 months postoperatively. The Cox regression model was used to calculate relative risk (RR) of reoperation. Results - There were statistically significant differences in PROM data with less pain, better satisfaction, and better quality of life after surgery using the posterior approach than using the direct lateral approach. The risk of reoperation was similar between the approaches. Interpretation - Hemiarthroplasty for hip fracture performed through a posterior approach rather than a direct lateral approach results in less pain, with better patient satisfaction and better quality of life. The risk of reoperation was similar with both approaches.


Asunto(s)
Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Hemiartroplastia/métodos , Medición de Resultados Informados por el Paciente , Calidad de Vida , Sistema de Registros , Encuestas y Cuestionarios , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Satisfacción del Paciente , Resultado del Tratamiento
11.
Acta Orthop ; 87(6): 546-553, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27550058

RESUMEN

Background and purpose - According to previous Nordic Arthroplasty Register Association (NARA) data, the 10-year implant survival of cemented total hip arthroplasties (THAs) is 94% in patients aged 65-74 and 96% in patients aged 75 or more. Here we report a brand-level comparison of cemented THA based on the NARA database, which has not been done previously. Patients and methods - We determined the rate of implant survival of the 9 most common cemented THAs in the NARA database. We used Kaplan-Meier analysis with 95% CI to study implant survival at 10 and 15 years, and Cox multiple regression to assess survival and hazard ratios (HRs), with revision for any reason as endpoint and with adjustment for age, sex, diagnosis, and femoral head material. Results - Spectron EF THA (89.9% (CI: 89.3-90.5)) and Elite THA (89.8% (CI: 89.0-90.6)) had the lowest 10-year survivorship. Lubinus (95.7% survival, CI: 95.5-95.9), MS 30 (96.6%, CI: 95.8-97.4), and C-stem THA (95.8%, CI: 94.8-96.8) had a 10-year survivorship of at least 95%. Lubinus (revision risk (RR) = 0.77, CI: 0.73-0.81), Müller (RR =0.83, CI: 0.70-0.99), MS-30 (RR =0.73, CI: 0.63-0.86), C-stem (RR =0.70, CI: 0.55-0.90), and Exeter Duration THA (RR =0.84, CI: 0.77-0.90) had a lower risk of revision than Charnley THA, the reference implant. Interpretation - The Spectron EF THA and the Elite THA had a lower implant survival than the Charnley, Exeter, and Lubinus THAs. Implant survival of the Müller, MS 30, CPT, and C-stem THAs was above the acceptable limit for 10-year survival.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Supervivencia de Injerto , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Sistema de Registros , Anciano , Dinamarca , Femenino , Finlandia , Humanos , Masculino , Noruega , Diseño de Prótesis , Falla de Prótesis , Reoperación , Factores de Riesgo , Suecia
12.
Hip Int ; 26(1): 43-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26743037

RESUMEN

PURPOSE: Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? METHODS: We designed a decision model for a cost-utility analysis of a cemented cup with acetabular impaction bone grafting versus an uncemented cup, in terms of cost per quality-adjusted life year (QALY) for the young adult with acetabular bone deficiency, in need for a primary total hip arthroplasty. Outcome probabilities and effectiveness were derived from the Radboud University Nijmegen Medical Centre and the Norwegian Hip Register. Multiple sensitivity analyses were used to assess the contribution of the included variables in the model's outcome. RESULTS: Cemented cups with impaction bone grafting were more cost-effective compared to the uncemented option in terms of costs per QALY. A scenario suggesting equal primary survival rates of both cemented and uncemented cups still showed an effect gain of the cemented cup with impaction bone grafting, but at higher costs. CONCLUSIONS: Based on this model, the first choice of treatment of the acetabular bone deficient osteoarthritic hip in a young patient is reconstruction with impaction bone grafting and a cemented cup.


Asunto(s)
Artroplastia de Reemplazo de Cadera/economía , Artroplastia de Reemplazo de Cadera/métodos , Trasplante Óseo/economía , Prótesis de Cadera/economía , Osteoartritis de la Cadera/cirugía , Acetábulo/patología , Acetábulo/cirugía , Adulto , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/instrumentación , Cementación , Análisis Costo-Beneficio , Técnicas de Apoyo para la Decisión , Humanos , Persona de Mediana Edad , Osteoartritis de la Cadera/economía , Osteoartritis de la Cadera/patología , Falla de Prótesis , Años de Vida Ajustados por Calidad de Vida , Adulto Joven
13.
Acta Orthop ; 86(6): 714-20, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26179889

RESUMEN

BACKGROUND AND PURPOSE: There have been few comparative studies on total knee replacement (TKR) with cemented tibia and uncemented femur (hybrid TKR). Previous studies have not shown any difference in revision rate between cemented and hybrid fixation, but these studies had few hybrid prostheses. We have evaluated the outcome of hybrid TKR based on data from the Norwegian Arthroplasty Register (NAR). PATIENTS AND METHODS: We compared 4,585 hybrid TKRs to 20,095 cemented TKRs with risk of revision for any cause as the primary endpoint. We included primary TKRs without patella resurfacing that were reported to the NAR during the years 1999-2012. To minimize the possible confounding effect of prosthesis brands, only brands that were used both as hybrids and cemented in more than 200 cases were included. Kaplan-Meier survival analysis and Cox regression analysis were done with adjustment for age, sex, and preoperative diagnosis. To include death as a competing risk, cumulative incidence function estimates were calculated. RESULTS: Estimated survival at 11 years was 94.3% (95% CI: 93.9-94.7) in the cemented TKR group and 96.3% (CI: 95.3-97.3) in the hybrid TKR group. The adjusted Cox regression analysis showed a lower risk of revision in the hybrid group (relative risk = 0.58, CI: 0.48-0.72, p < 0.001). The hybrid group included 3 brands of prostheses: LCS classic, LCS complete, and Profix. Profix hybrid TKR had lower risk of revision than cemented TKR, but the LCS classic and LCS complete did not. Kaplan-Meier estimated survival at 11 years was 96.8% (CI: 95.6-98.0) in the hybrid Profix group and 95.2% (CI: 94.6-95.8) in the cemented Profix group. Mean operating time was 17 min longer in the cemented group. INTERPRETATION: Survivorship of the hybrid TKR at 11 years was better than that for cemented TKR, or the same, depending on the brand of prosthesis. Hybrid fixation appears to be a safe and time-efficient alternative to cemented fixation in total knee replacement surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Anciano , Cementos para Huesos/uso terapéutico , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Noruega/epidemiología , Modelos de Riesgos Proporcionales , Falla de Prótesis/etiología , Sistema de Registros , Factores de Riesgo
14.
Acta Orthop ; 86(6): 734-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26058747

RESUMEN

BACKGROUND AND PURPOSE: Previous studies have found different outcomes after revision of knee arthroplasties performed after high tibial osteotomy (HTO). We evaluated the risk of revision of total knee arthroplasty with or without previous HTO in a large registry material. PATIENTS AND METHODS: 31,077 primary TKAs were compared with 1,399 TKAs after HTO, using Kaplan-Meier 10-year survival percentages and adjusted Cox regression analysis. RESULTS: The adjusted survival analyses showed similar survival in the 2 groups. The Kaplan-Meier 10-year survival was 93.8% in the primary TKA group and 92.6% in the TKA-post-HTO group. Adjusted RR was 0.97 (95% CI: 0.77-1.21; p = 0.8). INTERPRETATION: In this registry-based study, previous high tibial osteotomy did not appear to compromise the results regarding risk of revision after total knee arthroplasty compared to primary knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Osteotomía/efectos adversos , Falla de Prótesis/etiología , Reoperación/estadística & datos numéricos , Tibia/cirugía , Factores de Edad , Anciano , Australia/epidemiología , Análisis de Falla de Equipo , Femenino , Humanos , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Polietileno , Sistema de Registros , Factores de Riesgo , Factores de Tiempo
15.
Acta Orthop ; 86(4): 491-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25782042

RESUMEN

BACKGROUND AND PURPOSE: Medical treatment of rheumatoid arthritis (RA) has changed dramatically over the last 15 years, including immune modulation. We investigated the risk of revision for infection after primary total hip replacement (THR) in patients with rheumatoid arthritis over a 16-year period, and compared it with that in THR patients with osteoarthritis (OA). PATIENTS AND METHODS: We identified 13,384 THRs in RA patients and 377,287 THRs in OA patients from 1995 through 2010 in a dataset from the Nordic Arthroplasty Register Association (NARA). Kaplan-Meier survival curves, with revision for infection as the endpoint, were constructed. Cox regression analyses were performed to calculate the relative risk (RR) of revision for infection adjusted for age, sex, fixation technique, and year of primary surgery. RESULTS: RA patients had a 1.3 times (95% CI 1.0-1.6) higher risk of revision for infection. After 2001, this risk increased more for RA patients than for OA patients. During the first 3 months and from 8 years postoperatively, the risk of revision for infection was higher in RA patients with THRs fixated with antibiotic-loaded cement than in corresponding OA patients. INTERPRETATION: We found a slightly higher overall risk of revision for infection in RA patients than in OA patients, but this difference was only present after 2001. In THRs with antibiotic-loaded cement, the risk of very early and late infections leading to revision was higher in RA patients than in OA patients.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/microbiología , Osteoartritis de la Cadera/cirugía , Infecciones Relacionadas con Prótesis/epidemiología , Anciano , Estudios de Cohortes , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Sistema de Registros , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Factores de Riesgo , Países Escandinavos y Nórdicos/epidemiología , Factores de Tiempo
16.
Acta Orthop ; 86(4): 469-76, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25715878

RESUMEN

BACKGROUND AND PURPOSE: Data from the national joint registries in Australia and England and Wales have revealed inferior medium-term survivorship for metal-on-metal (MoM) total hip arthroplasty (THA) than for metal-on-polyethylene (MoP) THA. Based on data from the Nordic Arthroplasty Register Association (NARA), we compared the revision risk of cementless stemmed THA with MoM and MoP bearings and we also compared MoM THA to each other. PATIENTS AND METHODS: We identified 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). The patients were followed until revision, death, emigration, or the end of the study period (December 31, 2011), and median follow-up was 3.6 (interquartile range (IQR): 2.4-4.8) years for MoM bearings and 3.4 (IQR: 2.0-5.8) years for MoP bearings. Multivariable regression in the presence of competing risk of death was used to assess the relative risk (RR) of revision for any reason (with 95% confidence interval (CI)). RESULTS: The cumulative incidence of revision at 8 years of follow-up was 7.0% (CI: 6.0-8.1) for MoM bearings and 5.1% (CI: 4.7-5.6) for MoP bearings. At 6 years of follow-up, the RR of revision for any reason was 1.5 (CI: 1.3-1.7) for MoM bearings compared to MoP bearings. The RR of revision for any reason was higher for the ASR (adjusted RR = 6.4, CI: 5.0-8.1), the Conserve Plus (adjusted RR = 1.7, CI: 1.1-2.5) and "other" acetabular components (adjusted RR = 2.4, CI: 1.5-3.9) than for MoP THA at 6 years of follow-up. INTERPRETATION: At medium-term follow-up, the survivorship for cementless stemmed MoM THA was inferior to that for MoP THA, and metal-related problems may cause higher revision rates for MoM bearings with longer follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Metales , Reoperación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Polietileno , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Países Escandinavos y Nórdicos
17.
Acta Orthop ; 86(1): 18-25, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25175664

RESUMEN

BACKGROUND AND PURPOSE: It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. PATIENTS AND METHODS: We identified 152,410 THA procedures using uncemented stems that were performed between 1995 and 2011 and registered in the Nordic Arthroplasty Register Association (NARA) database. We excluded 19,446 procedures that used stem brands less than 500 times in each country, procedures performed due to diagnoses other than osteoarthritis or pediatric hip disease, and procedures with missing information on the type of coating. 22 stem brands remained (which were used in 116,069 procedures) for analysis of revision of any component. 79,192 procedures from Denmark, Norway, and Sweden were analyzed for the endpoint stem revision. Unadjusted survival rates were calculated according to Kaplan-Meier, and Cox proportional hazards models were fitted in order to calculate hazard ratios (HRs) for the risk of revision with 95% confidence intervals (CIs). RESULTS: Unadjusted 10-year survival with the endpoint revision of any component for any reason was 92.1% (CI: 91.8-92.4). Unadjusted 10-year survival with the endpoint stem revision due to aseptic loosening varied between the stem brands investigated and ranged from 96.7% (CI: 94.4-99.0) to 99.9% (CI: 99.6-100). Of the stem brands with the best survival, stems with and without HA coating were found. The presence of HA coating was not associated with statistically significant effects on the adjusted risk of stem revision due to aseptic loosening, with an HR of 0.8 (CI: 0.5-1.3; p = 0.4). The adjusted risk of revision due to infection was similar in the groups of THAs using HA-coated and non-HA-coated stems, with an HR of 0.9 (CI: 0.8-1.1; p = 0.6) for the presence of HA coating. The commonly used Bimetric stem (n = 25,329) was available both with and without HA coating, and the adjusted risk of stem revision due to aseptic loosening was similar for the 2 variants, with an HR of 0.9 (CI: 0.5-1.4; p = 0.5) for the HA-coated Bimetric stem. INTERPRETATION: Uncemented HA-coated stems had similar results to those of uncemented stems with porous coating or rough sand-blasted stems. The use of HA coating on stems available both with and without this surface treatment had no clinically relevant effect on their outcome, and we thus question whether HA coating adds any value to well-functioning stem designs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementación/métodos , Materiales Biocompatibles Revestidos/uso terapéutico , Hidroxiapatitas/uso terapéutico , Osteoartritis de la Cadera/cirugía , Sistema de Registros , Anciano , Estudios de Cohortes , Dinamarca , Femenino , Luxación Congénita de la Cadera/cirugía , Humanos , Estimación de Kaplan-Meier , Enfermedad de Legg-Calve-Perthes/cirugía , Masculino , Persona de Mediana Edad , Noruega , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación/estadística & datos numéricos , Suecia , Resultado del Tratamiento
19.
Acta Orthop ; 86(1): 63-70, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25386737

RESUMEN

BACKGROUND AND PURPOSE: Previously, implant survival of total shoulder prostheses was reported to be inferior to that of hemiprostheses. However, the use of total prostheses has increased in Norway due to reported good functional results. On this background, we wanted to study implant survival of 4 major shoulder prosthesis types in Norway between 1994 and 2012. PATIENTS AND METHODS: The study population comprised 4,173 patients with shoulder replacements reported to the Norwegian Arthroplasty Register, including 2,447 hemiprostheses (HPs), 444 anatomic total prostheses (ATPs), 454 resurfacing prostheses (RPs), and 828 reversed total prostheses (RTPs). Three time periods were compared: 1994-1999, 2000-2005, and 2006-2012. Kaplan-Meier failure curves were used to compare implant failure rates for subgroups of patients, and adjusted risks of revision were calculated using Cox regression analysis. RESULTS: For prostheses inserted from 2006 through 2012, the 5-year survival rates were 95% for HPs (as opposed to 94% in 1994-1999), 95% for ATPs (75% in 1994-1999), 87% for RPs (96% in 1994-1999), and 93% for RTPs (91% in 1994-1999). During the study period, the implant survival improved significantly for ATPs (p < 0.001). A tendency of better results with acute fracture and worse results in sequelae after previous fractures was seen in all time periods. INTERPRETATION: The 5-year implant survival rates were good with all prosthesis types, and markedly improved for anatomic total prostheses in the last 2 study periods. The better functional results with total shoulder prostheses than with hemiprostheses support the trend towards increased use of total shoulder prostheses.


Asunto(s)
Artroplastia de Reemplazo/métodos , Prótesis Articulares , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Noruega , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
20.
J Bone Joint Surg Am ; 96 Suppl 1: 12-8, 2014 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-25520414

RESUMEN

BACKGROUND: HXLPE (highly cross-linked polyethylene) has greater wear resistance compared with UHMWPE (ultra-high molecular weight polyethylene), which may contribute to improving the outcomes of total hip arthroplasty with a large femoral head. However, no information is available regarding the effect of femoral head size on the survivorship of HXLPE hip prostheses. The aim of the present study was to provide evidence regarding whether femoral head size has an effect on the risk of revision when an HXLPE liner is used on a metal head. METHODS: A distributed health data network was developed by the ICOR (International Consortium of Orthopaedic Registries). Six national and regional registries are participating in this network: Kaiser Permanente, HealthEast, the Emilia-Romagna region in Italy, the Catalan region in Spain, Norway, and Australia. Data from each registry were standardized and provided at an aggregate level for each of the variables of interest. Patients with osteoarthritis who were forty-five to sixty-four years of age and had undergone uncemented total hip arthroplasty were included in the present study. Analyses were performed on the basis of individual patient profiles, utilizing the variables collected from each registry. The outcome of interest was the time to the first revision (for any reason). Survival probabilities and their standard errors were extracted from each registry for each unique combination of the covariates and were combined through multivariate meta-analysis utilizing linear mixed models to compare survivorship for <32-mm, 32-mm, and >32-mm femoral head sizes. RESULTS: A total of 14,372 total hip arthroplasties were included in the study. The five-year rate of revision surgery varied from 1.9% to 3.2% among registries. The risk of revision did not differ significantly between <32-mm and 32-mm head sizes (HR [hazard ratio] = 0.91, 95% CI [confidence interval] = 0.69 to 1.19) or between >32-mm and 32-mm sizes (HR = 1.05, 95% CI = 0.70 to 1.55). CONCLUSIONS: The results of our study provide relevant data to orthopaedic surgeons deciding on the use of a larger articulation in a metal-on-polyethylene bearing. A larger head diameter should not be considered a detriment to device survival when an HXLPE liner is used. However, efforts to force the use of a large-size implant appear unsupported, as similar survivorship was observed for all head diameter groups.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Osteoartritis de la Cadera/cirugía , Femenino , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...