Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Asunto principal
Intervalo de año de publicación
1.
Clin Oral Investig ; 27(9): 5439-5448, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37479870

RESUMEN

OBJECTIVE: To investigate the characteristics of particle generation and dispersion during dental procedure using digital inline holography (DIH) METHODS: Particles at two locations, near-field and far-field, which represent the field closer to the procedure location and within 0.5 m from the procedure location respectively, are studied using two different DIH systems. The effect of three parameters namely rotational speed, coolant flow rate, and bur angle on particle generation and dispersion are evaluated by using 10 different operating conditions. The particle characteristics at different operating conditions are estimated from the holograms using machine learning-based analysis. RESULTS: The particle concentration decreased by at least two orders of magnitude between the near-field and far-field locations across the 10 different operating conditions, indicating significant dispersion of the particles. High rotational speed is found to produce a larger number of smaller particles, while lower rotational speeds generate larger particles. Coolant flow rate is found to have a greater impact on particle transport to the far-field location. Irregular shape dental particles account for 29% of total particles at far-field location, with the majority of these irregular shape particles having diameters ranging from 12 to 18 µm. CONCLUSIONS: All three parameters have significant effects on particle generation and dispersion, with rotational speed having a more significant influence on particle generation at near-field and coolant flow rate playing a more important role on particle transport to the far-field. CLINICAL RELEVANCE: This study provides valuable insights on particle characteristics during high-speed drilling. It can help dental professionals minimize exposure risks for themselves and patients by optimizing clinical operating conditions.

2.
Biotechnol Bioeng ; 120(5): 1399-1410, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36710508

RESUMEN

Obtaining in situ measurements of biological microparticles is crucial for both scientific research and numerous industrial applications (e.g., early detection of harmful algal blooms, monitoring yeast during fermentation). However, existing methods are limited to offer timely diagnostics of these particles with sufficient accuracy and information. Here, we introduce a novel method for real-time, in situ analysis using machine learning (ML)-assisted digital inline holography (DIH). Our ML model uses a customized YOLOv5 architecture specialized for the detection and classification of small biological particles. We demonstrate the effectiveness of our method in the analysis of 10 plankton species with equivalent high accuracy and significantly reduced processing time compared to previous methods. We also applied our method to differentiate yeast cells under four metabolic states and from two strains. Our results show that the proposed method can accurately detect and differentiate cellular and subcellular features related to metabolic states and strains. This study demonstrates the potential of ML-driven DIH approach as a sensitive and versatile diagnostic tool for real-time, in situ analysis of both biotic and abiotic particles. This method can be readily deployed in a distributive manner for scientific research and manufacturing on an industrial scale.


Asunto(s)
Holografía , Holografía/métodos , Saccharomyces cerevisiae , Aprendizaje Automático
3.
Phys Fluids (1994) ; 33(5): 057107, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34040337

RESUMEN

Many indoor places, including aged classrooms and offices, prisons, homeless shelters, etc., are poorly ventilated but resource-limited to afford expensive ventilation upgrades or commercial air purification systems, raising concerns on the safety of opening activities in these places in the era of the COVID-19 pandemic. To address this challenge, using computational fluid dynamics, we conducted a systematic investigation of airborne transmission in a classroom equipped with a single horizontal unit ventilator (HUV) and evaluate the performance of a low-cost box fan air cleaner for risk mitigation. Our study shows that placing box fan air cleaners in the classroom results in a substantial reduction of airborne transmission risk across the entire space. The air cleaner can achieve optimal performance when placed near the asymptomatic patient. However, without knowing the location of the patient, the performance of the cleaner is optimal near the HUV with the air flowing downwards. In addition, we find that it is more efficient in reducing aerosol concentration and spread in the classroom by adding air cleaners in comparison with raising the flow rate of HUV alone. The number and placement of air cleaners need to be adjusted to maintain their efficacy for larger classrooms and to account for the thermal gradient associated with a human thermal plume and hot ventilation air during cold seasons. Overall, our study shows that box fan air cleaners can serve as an effective low-cost alternative for mitigating airborne transmission risks in poorly ventilated spaces.

4.
J Aerosol Sci ; 151: 105669, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32952210

RESUMEN

The potential airborne transmission of COVID-19 has raised significant concerns regarding the safety of musical activities involving wind instruments. However, currently, there is a lack of systematic study and quantitative information of the aerosol generation during these instruments, which is crucial for offering risk assessment and the corresponding mitigation strategies for the reopening of these activities. Collaborating with 15 musicians from the Minnesota Orchestra, we conduct a systematic study of the aerosol generation from a large variety of wind instruments under different music dynamic levels and articulation patterns. We find that the aerosol concentration from different brass and woodwinds exhibits two orders of magnitude variation. Accordingly, we categorize the instruments into low (tuba), intermediate (bassoon, piccolo, flute, bass clarinet, French horn, and clarinet) and high risk (trumpet, bass trombone, and oboe) levels based on a comparison of their aerosol generation with those from normal breathing and speaking. In addition, we observe that the aerosol generation can be affected by the changing dynamic level, articulation pattern, the normal respiratory behaviors of individuals, and even the usage of some special techniques during the instrument play. However, such effects vary substantially for different types of instrument, depending on specific breathing techniques as well as the tube structure and inlet design of the instrument. Overall, our findings can bring insights into the risk assessment of airborne decrease transmission and the corresponding mitigation strategies for various musical activities involving wind instrument plays, including orchestras, community and worship bands, music classes, etc.

5.
J Aerosol Sci ; 151: 105661, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32968325

RESUMEN

The lack of quantitative risk assessment of airborne transmission of COVID-19 under practical settings leads to large uncertainties and inconsistencies in our preventive measures. Combining in situ measurements and computational fluid dynamics simulations, we quantify the exhaled particles from normal respiratory behaviors and their transport under elevator, small classroom, and supermarket settings to evaluate the risk of inhaling potentially virus-containing particles. Our results show that the design of ventilation is critical for reducing the risk of particle encounters. Inappropriate design can significantly limit the efficiency of particle removal, create local hot spots with orders of magnitude higher risks, and enhance particle deposition causing surface contamination. Additionally, our measurements reveal the presence of a substantial fraction of faceted particles from normal breathing and its strong correlation with breathing depth.

6.
ArXiv ; 2020 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-32676520

RESUMEN

The lack of quantitative risk assessment of airborne transmission of COVID-19 under practical settings leads to large uncertainties and inconsistencies in our preventive measures. Combining in situ measurements and numerical simulations, we quantify the exhaled particles from normal respiratory behaviors and their transport under elevator, small classroom and supermarket settings to evaluate the risk of inhaling potentially virus-containing particles. Our results show that the design of ventilation is critical for reducing the risk of particle encounters. Inappropriate design can significantly limit the efficiency of particle removal, create local hot spots with orders of magnitude higher risks, and enhance particle deposition causing surface contamination. Additionally, our measurements reveal the presence of substantial fraction of crystalline particles from normal breathing and its strong correlation with breathing depth.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...