Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Perfusion ; 28(1): 61-5, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23042900

RESUMEN

Heparin is one of the oldest drugs still in widespread clinical use. Its discovery in 1916 predates the establishment of the Food and Drug Administration. Since 1935, over 15,000 research papers have been published on the effects of heparin. Because the exact chemical formula of heparin is unknown, synthetic manufacturing has proven difficult. In 2008, a worldwide recall of heparin occurred. Scientists determined that a contaminant known as oversulfated chondroitin sulfate was responsible for the numerous deaths and adverse events. This contaminant was first traced to a chemical plant in Changzou, China. This article will review the discovery of heparin and the adulteration process that jeopardized the world's heparin supply.


Asunto(s)
Sulfatos de Condroitina , Contaminación de Medicamentos , Recall de Medicamento , Heparina , China , Humanos
3.
Perfusion ; 12(1): 27-30, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9131718

RESUMEN

The Immediate Response Mobile Analysis (IRMA) blood analysis system (Diametrics Medical Incorporated, St Paul, MN, USA) is a new point-of-care testing device that uses technology similar to the Gem Premier (Mallinckrodt Sensor Systems Incorporated, Ann-Arbor, MI, USA), which are ion-specific electrodes. We compared these two analysers using both patient blood samples (n = 50) and aqueous quality control solutions (n = 45). Linear regression (Pearson product-moment correlation coefficient) was performed to quantify the strength of the association between results. In addition, bias and precision were determined in accordance with the method described by Bland and Altman. The results demonstrated excellent correlation between the IRMA and the Gem Premier, and bias and precision were acceptable for both patient and quality control samples. Reproducibility of results was also assessed using one level of aqueous quality control solution (n = 50). The IRMA demonstrated very little variance in parameter readings over a five-day study period.


Asunto(s)
Análisis Químico de la Sangre/instrumentación , Análisis Químico de la Sangre/métodos , Sistemas de Atención de Punto , Sangre , Humanos , Control de Calidad , Análisis de Regresión , Reproducibilidad de los Resultados , Soluciones
5.
Tex Heart Inst J ; 17(2): 142-3; discussion 143, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-15227402
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA