Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Vet Diagn Invest ; 34(1): 15-22, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34654336

RESUMEN

The ROTEM platelet device, a point-of-care whole blood platelet impedance aggregometer, is an add-on to the rotational thromboelastometry ROTEM delta device. The latter has been validated in dogs. We examined whether canine whole blood is suited for analysis with the ROTEM platelet device using adenosine-5'-diphosphate (ADP) and arachidonic acid (ARA) as agonists for platelet activation, and if there are significant differences between sample storage times and anticoagulants used. Subsequently, we determined canine reference intervals (RIs) for the ROTEM platelet device for ADP and ARA. In a pilot study, we examined whole blood from 7 dogs after 15-min and 60-min storage of lithium-heparinized samples and 40-min and 80-min storage of hirudinized samples. Statistical analysis showed no significant differences between ROTEM platelet device results for both ADP and ARA in lithium-heparin and hirudin anticoagulated canine whole blood. Lithium-heparinized blood samples analyzed after 15-min storage had the lowest coefficient of variation. RIs were determined for heparinized whole blood samples from 49 dogs after 15 min of storage.


Asunto(s)
Anticoagulantes , Plaquetas , Animales , Anticoagulantes/farmacología , Pruebas Diagnósticas de Rutina , Perros , Impedancia Eléctrica , Proyectos Piloto
2.
Res Vet Sci ; 129: 129-136, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31982776

RESUMEN

The objectives of this prospective study were determination of reference intervals (RI) for rotational thromboelastometry (ROTEM) parameters in single use reagents and to evaluate correlations between plasmatic coagulation times and ROTEM parameters. Blood was sampled from a jugular vein in 49 client-owned healthy dogs and ex-tem S, in-tem S, fib-tem S and ap-tem S parameters, prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, haematology, blood chemistry and venous blood gas analysis was performed. Determination of RI was performed using Excel add-in Reference Value Advisor and correlations between PT, aPTT and fibrinogen with selected ROTEM parameters were determined by Spearman correlation. Ex-tem S maximum clot firmness (MCF) RI are smaller compared to RI in people and liquid ex-tem in dogs while maximum lysis was comparable to those in people but smaller than previously reported in dogs. A strong correlation was found between fibrinogen measured by Clauss and fib-tem S and in-tem S MCF (r = 0.541, P < .001 and r = 0.610, P < .001, respectively). PT showed a significant but moderate correlation with ex-tem S CT (r = 0.340, P = .030), in-tem S CFT (r = 0.433, P = .003), fib-tem S CT (r = 0.426, P = .009) and ap-tem S CT (r = 0.354, P = .015) while aPTT was not significantly correlated with any of the evaluated parameters. In conclusion, this study provides single use reagent ROTEM parameter RIs that are different from RI determined with liquid reagents. Significant correlations between fibrinogen concentrations measured by Clauss and clot firmness of fib-tem S and in-tem S profiles and between PT and clotting times of all reagents were identified.


Asunto(s)
Pruebas de Coagulación Sanguínea/veterinaria , Coagulación Sanguínea/fisiología , Perros/sangre , Tromboelastografía/veterinaria , Animales , Femenino , Fibrinógeno , Humanos , Masculino , Tiempo de Tromboplastina Parcial/veterinaria , Estudios Prospectivos , Tiempo de Protrombina/veterinaria , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...