Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 15(20)2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36295361

RESUMEN

High entropy alloys are a promising new class of metal alloys with outstanding radiation resistance and thermal stability. The interaction with hydrogen might, however, have desired (H storage) or undesired effects, such as hydrogen-induced embrittlement or tritium retention in the fusion reactor wall. High entropy alloy WMoTaNbV and bulk W samples were used to study the quantity of irradiation-induced trapping sites and properties of D retention by employing thermal desorption spectrometry, secondary ion mass spectrometry, and elastic recoil detection analysis. The D implantation was not found to create additional hydrogen traps in WMoTaNbV as it does in W, while 90 at% of implanted D is retained in WMoTaNbV, in contrast to 35 at% in W. Implantation created damage predicted by SRIM is 0.24 dpa in WMoTaNbV, calculated with a density of 6.044×1022 atoms/cm3. The depth of the maximum damage was 90 nm. An effective trapping energy for D in WMoTaNbV was found to be about 1.7 eV, and the D emission temperature was close to 700 °C.

2.
Nucl Med Biol ; 84-85: 102-110, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32334356

RESUMEN

INTRODUCTION: Porous silicon (PSi) nanoparticles are capable of delivering therapeutic payloads providing targeted delivery and sustained release of the payloads. In this work we describe the development and proof-of-concept in vivo evaluation of thermally hydrocarbonized porous silicon (PSi) nanoparticles that are implanted with radioactive 155Tb atoms and coated with red blood cell (RBC) membrane (155Tb-THCPSi). The developed nanocomposites can be utilized as an intravenous delivery platform for theranostic radionuclides. METHODS: THCPSi thin films were implanted with 155Dy ions that decay to 155Tb at the ISOLDE radioactive ion-beam (RIB) facility at CERN. The films were processed to nanoparticles by ball-milling and sonication, and subsequently coated with either a solid lipid and RBC membrane or solely with RBC membrane. The nanocomposites were evaluated in vitro for stability and in vivo for circulation half-life and ex vivo for biodistribution in Balb/c mice. RESULTS: Nanoporous THCPSi films were successfully implanted with 155Tb and processed to coated nanoparticles. The in vitro stability of the particles in plasma and buffer solutions was not significantly different between the particle types, and therefore the RBC membrane coated particles with less laborious processing method were chosen for the biological evaluation. The RBC membrane coating enhanced significantly the blood half-life compared to bare THCPSi particles. In the ex vivo biodistribution study a pronounced accumulation to the spleen was found, with lower uptake in the liver and a minor uptake in the lung, gall bladder and bone marrow. CONCLUSIONS: We have demonstrated, using 155Tb RIB-implanted PSi nanoparticles coated with mouse RBC membranes, the feasibility of using such a theranostic nanosystem for the delivery of RIB based radionuclides with prolonged circulation time. ADVANCES IN KNOWLEDGE AND IMPLICATIONS FOR PATIENT CARE: For the first time, the RIB implantation technique has been utilized to produce PSi nanoparticle with a surface modified for better persistence in circulation. When optimized, these particles could be used in targeted radionuclide therapy with a combination of chemotherapeutic payload within the PSi structure.


Asunto(s)
Membrana Eritrocítica/química , Nanopartículas/química , Radioisótopos/química , Silicio/química , Terbio/química , Animales , Tampones (Química) , Estabilidad de Medicamentos , Semivida , Humanos , Ratones , Porosidad
3.
Nanotechnology ; 25(35): 355701, 2014 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-25116235

RESUMEN

Graphene has attracted attention as a potential strengthening material and functional component in suspended membranes as utilized in micro and nanosystems. Development of a practical and scalable fabrication process is a necessary step to allow the exceptional material properties of graphene to be fully exploited in composite structures. Using standard and scalable microfabrication processes, we fabricated free-standing chemical vapor deposition monolayer graphene-reinforced Al2O3 composite membranes, 0.5 mm in diameter, that are strong and robust. Bulge tests revealed that the graphene reinforcement increased the membrane fracture strength by a factor of at least three and maximum sustainable strain from 0.28% to at least 0.69%. We show that the graphene-reinforced membranes are even tolerant to significant cracking without loss of membrane integrity. The graphene composite membranes' freestanding area of ∼ 200 000 µm(2) is almost a thousand times larger than suspended graphene membranes reported elsewhere. The presented graphene composite membranes may be seen as representing an interesting new class of durable composite materials warranting further study and having potential for broad applicability in a variety of fields.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA