Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Radiol Med ; 123(6): 456-462, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29380261

RESUMEN

BACKGROUND: Intracranial arterial calcifications (ICAC) are often detected on unenhanced CT of patients with an age > 60. However, association with the subsequent occurrence of major adverse cardiovascular events (MACE) has not yet been evaluated. PURPOSE: This study aimed at evaluating the association of ICAC with subsequent MACE and overall mortality. METHODS: In this retrospective, IRB approved study, we included 175 consecutive patients (89 males, mean age 78.3 ± 8.5 years) of age > 60 years who underwent an unenhanced CT of the head due to minor trauma or neurological disorders. Presence of ICAC was determined in seven intracranial arteries using a semi-quantitative scale, which resulted in the calcified plaque score (CPS). Clinical follow-up information was obtained by questionnaires and telephone interviews. MACE was defined as myocardial infarction or revascularization, stroke or death due to cardiovascular event. RESULTS: Mean follow-up time was 39.8 ± 7.8 months, resulting in 579.7 patient-years of follow-up. Overall, 36 MACE occurred during follow-up (annual event rate = 6.2%/year). Mean CPS was significantly higher in subjects with MACE during follow-up compared to subjects without MACE (p < 0.01). In 15 patients CPS was 0; in none of these patients MACE was registered. Kaplan-Meier-analysis revealed that patients with a low plaque burden (CPS < 5) had a significant longer MACE-free and overall survival than patients with a high plaque burden (CPS ≥ 5) (p < 0.01). CONCLUSION: Patients with ICAC have an increased risk for future cardio- or cerebrovascular events. Therefore, ICAC might be a prognostic factor to determine the risk for these events in older patients.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Trastornos Cerebrovasculares/complicaciones , Trastornos Cerebrovasculares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/complicaciones , Calcificación Vascular/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/mortalidad , Femenino , Humanos , Entrevistas como Asunto , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Encuestas y Cuestionarios , Tasa de Supervivencia , Calcificación Vascular/mortalidad
2.
Neuroradiology ; 58(6): 569-576, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26906110

RESUMEN

INTRODUCTION: The aims of the present study are to evaluate the potential of high-resolution black-blood MRI (hr-bb-cMRI) to differentiate common cervical arteriopathies and to evaluate interobserver reproducibility. METHODS: Forty-three consecutive patients with distinct cervical arteriopathies were examined with cervical hr-bb-cMRI at 3.0 Te with fat-saturated pre- and post-contrast T1w, T2w, and TOF images using dedicated carotid surface coils at our institution. Twenty-three patients had atherosclerotic disease, causing significant stenosis in 12 patients while 11 patients had moderate stenosis. Eight patients presented with cervical vasculitis, and five patients had arterial dissection. Furthermore, seven control subjects with no evidence of carotid disease were included. Two experienced readers blinded to all clinical information reviewed all MR images and classified both carotid and vertebral arteries as affected either by atherosclerosis, dissection, vasculitis, or no disease. Finally, a consensus reading was performed. RESULTS: On a per-vessel level, test performance parameters (sensitivity, specificity, positive predictive value, negative predictive value) were 95, 97.7, 92.9, and 98.5 % for atherosclerotic disease; 91, 100, 100, and 98.7 % for vasculitis; and 100, 100, 100, and 100 % for dissection, respectively. On a per-patient level, performance parameters were 95.7, 85.7, 97.2, and 85.7 % for the diagnosis of atherosclerosis and 100, 100, 100, and 100 % for the diagnosis of dissection and of vasculitis, respectively. Accuracy rates were all above 95 % for all entities. There was a high agreement between observers both in a per-vessel (κ = 0.83) and in a per-patient analysis (κ = 0.82). CONCLUSION: This study demonstrates that hr-bb-cMRI is able to non-invasively differentiate between the most common cervical arteriopathies with an excellent interreader reproducibility.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Angiografía Cerebral/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
PLoS One ; 9(8): e105413, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25144396

RESUMEN

BACKGROUND AND PURPOSE: While penumbra assessment has become an important part of the clinical decision making for acute stroke patients, there is a lack of studies measuring the reliability and reproducibility of defined assessment techniques in the clinical setting. Our aim was to determine reliability and reproducibility of different types of three-dimensional penumbra assessment methods in stroke patients who underwent whole brain CT perfusion imaging (WB-CTP). MATERIALS AND METHODS: We included 29 patients with a confirmed MCA infarction who underwent initial WB-CTP with a scan coverage of 100 mm in the z-axis. Two blinded and experienced readers assessed the flow-volume-mismatch twice and in two quantitative ways: Performing a volumetric mismatch analysis using OsiriX imaging software (MM(VOL)) and visual estimation of mismatch (MM(EST)). Complementarily, the semiquantitative Alberta Stroke Programme Early CT Score for CT perfusion was used to define mismatch (MM(ASPECTS)). A favorable penumbral pattern was defined by a mismatch of ≥ 30% in combination with a cerebral blood flow deficit of ≤ 90 ml and an MM(ASPECTS) score of ≥ 1, respectively. Inter- and intrareader agreement was determined by Kappa-values and ICCs. RESULTS: Overall, MM(VOL) showed considerably higher inter-/intrareader agreement (ICCs: 0.751/0.843) compared to MM(EST) (0.292/0.749). In the subgroup of large (≥ 50 mL) perfusion deficits, inter- and intrareader agreement of MM(VOL) was excellent (ICCs: 0.961/0.942), while MM(EST )interreader agreement was poor (0.415) and intrareader agreement was good (0.919). With respect to penumbra classification, MM(VOL) showed the highest agreement (interreader agreement: 25 agreements/4 non-agreements/κ: 0.595; intrareader agreement 27/2/0.833), followed by MM(EST) (22/7/0.471; 23/6/0.577), and MM(ASPECTS) (18/11/0.133; 21/8/0.340). CONCLUSION: The evaluated approach of volumetric mismatch assessment is superior to pure visual and ASPECTS penumbra pattern assessment in WB-CTP and helps to precisely judge the extent of 3-dimensional mismatch in acute stroke patients.


Asunto(s)
Encéfalo/metabolismo , Imagen de Perfusión , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/metabolismo , Tetraspaninas/metabolismo , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/patología , Femenino , Humanos , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/metabolismo , Masculino , Persona de Mediana Edad , Accidente Cerebrovascular/patología , Factores de Tiempo
4.
Invest Radiol ; 49(11): 720-7, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24901546

RESUMEN

OBJECTIVES: The aim of this study was to compare single-slice and 3-dimensional (3D) analysis for magnetic resonance renography (plasma flow [FP], plasma volume [VP], and glomerular filtration rate [GFR]) and for dynamic contrast-enhanced magnetic resonance imaging (MRI) of renal tumors (FP, VP, permeability-surface area product), respectively. MATERIAL AND METHODS: We prospectively included 22 patients (43 kidneys with 22 suspicious renal lesions) and performed preoperative and postoperative imaging before and after partial nephrectomy, respectively. Of the 22 renal lesions, 15 turned out to be renal cell carcinoma and were included in the tumor analysis, altogether leading to 86 renal and 15 tumor MRI scans, respectively. Dynamic contrast-enhanced MRI was performed with a time-resolved angiography with stochastic trajectories sequence (spatial resolution, 2.6 × 2.6 × 2.6 mm3; temporal resolution, 2.5 seconds) at 3 T (Magnetom Verio; Siemens Healthcare Sector) after injection of 0.05 mmol/kg body weight Gadobutrol (Bayer Healthcare Pharmaceuticals). Analysis was performed using regions of interest encompassing a single central slice and the whole kidney/tumor, respectively. A 2-compartment model yielding FP, VP, GFR, or tumor permeability-surface area product was used for kinetic modelling. Modelling was performed based on relative contrast enhancement to account for coil-related inhomogeneity. Significance in difference, agreement, and goodness of fit of the data to the curve was assessed with paired t tests, Bland-Altman plots, and χ2 test, respectively. RESULTS: Bland-Altman analysis revealed a good agreement between both types of measurement for kidneys and tumors, respectively. Results between single-slice and whole-kidney regions of interest showed significant differences for Fp (single slice, 256.1 ± 104.1 mL/100 mL/min; whole kidney, 217.2 ± 92.5 mL/100 mL/min; P < 0.01). Regarding VP and GFR, no significant differences were observed. The χ2 test showed a significantly better goodness of fit of the data to the curve for whole kidneys (0.30% ± 0.18%) than for single slices (0.43% ± 0.26%) (P < 0.01). In contrast to renal assessment, tumor analysis showed no significant differences regarding functional parameters and χ test, respectively. CONCLUSION: In dynamic contrast-enhanced MRI of the kidney, both 3D whole-organ/tumor and single-slice analyses provide roughly comparable values in functional analysis. However, 3D assessment is considerably more precise and should be preferred if available.


Asunto(s)
Carcinoma de Células Renales/diagnóstico , Medios de Contraste , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Renales/diagnóstico , Imagen por Resonancia Magnética/métodos , Femenino , Tasa de Filtración Glomerular , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Riñón/patología , Enfermedades Renales/diagnóstico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
5.
Acad Radiol ; 20(6): 685-93, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23664397

RESUMEN

PURPOSE: To investigate a multiparametric magnetic resonance imaging (MRI) approach comprising diffusion-weighted imaging (DWI), blood oxygen-dependent (BOLD), and dynamic contrast-enhanced (DCE) MRI for characterization and differentiation of primary renal cell carcinoma (RCC). MATERIAL AND METHODS: Fourteen patients with clear-cell carcinoma and four patients with papillary RCC were examined with DWI, BOLD MRI, and DCE MRI at 1.5T. The apparent diffusion coefficient (ADC) was calculated with a monoexponential decay. The spin-dephasing rate R2* was derived from parametric R2* maps. DCE-MRI was analyzed using a two-compartment exchange model allowing separation of perfusion (plasma flow [FP] and plasma volume [VP]), permeability (permeability surface area product [PS]), and extravascular extracellular volume (VE). Statistical analysis was performed with Wilcoxon signed-rank test, Pearson's correlation coefficient, and receiver operating characteristic curve analysis. RESULTS: Clear-cell RCC showed higher ADC and lower R2* compared to papillary subtypes, but differences were not significant. FP of clear-cell subtypes was significantly higher than in papillary RCC. Perfusion parameters showed moderate but significant inverse correlation with R2*. VE showed moderate inverse correlation with ADC. Fp and Vp showed best sensitivity for histological differentiation. CONCLUSION: Multiparametric MRI comprising DWI, BOLD, and DCE MRI is feasible for assessment of primary RCC. BOLD moderately correlates to DCE MRI-derived perfusion. ADC shows moderate correlation to the extracellular volume, but does not correlate to tumor oxygenation or perfusion. In this preliminary study DCE-MRI appeared superior to BOLD and DWI for histological differentiation.


Asunto(s)
Carcinoma de Células Renales/metabolismo , Carcinoma de Células Renales/patología , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias Renales/metabolismo , Neoplasias Renales/patología , Angiografía por Resonancia Magnética/métodos , Oxígeno/sangre , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oximetría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
6.
Invest Radiol ; 48(2): 79-85, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23288014

RESUMEN

OBJECTIVES: The objective of this study was to determine whether automated quantification of lung perfused blood volume (PBV) in dual-energy computed tomographic pulmonary angiography (DE-CTPA) can be used to assess the severity and regional distribution of pulmonary hypoperfusion in emphysema. MATERIALS AND METHODS: We retrospectively analyzed 40 consecutive patients (mean age, 67 [13] years) with pulmonary emphysema, who have no cardiopulmonary comorbidities, and a DE-CTPA negative for pulmonary embolism. Automated quantification of global and regional pulmonary PBV was performed using the syngo Dual Energy application (Siemens Healthcare). Similarly, the global and regional degrees of parenchymal hypodensity were assessed automatically as the percentage of voxels with a computed tomographic density less than -900 Hounsfield unit. Emphysema severity was rated visually, and pulmonary function tests were obtained by chart review, if available. RESULTS: Global PBV generated by automated quantification of pulmonary PBV in the DE-CTPA data sets showed a moderately strong but highly significant negative correlation with residual volume in percentage of the predicted residual volume (r = -0.62; P = 0.002; n = 23) and a positive correlation with forced expiratory volume in 1 second in percentage of the predicted forced expiratory volume in 1 second (r = 0.67; P < 0.001; n = 23). Global PBV values strongly correlated with diffusing lung capacity for carbon monoxide (r = 0.80; P < 0.001; n = 15). Pulmonary PBV values decreased with visual emphysema severity (r = -0.46, P = 0.003, n = 40). Moderate negative correlations were found between global PBV values and parenchymal hypodensity both in a per-patient (r = -0.63; P < 0.001; n = 40) and per-region analyses (r = -0.62; P < 0.001; n = 40). CONCLUSIONS: Dual-energy computed tomographic pulmonary angiography allows simultaneous assessment of lung morphology, parenchymal density, and pulmonary PBV. In patients with pulmonary emphysema, automated quantification of pulmonary PBV in DE-CTPA can be used for a quick, reader-independent estimation of global and regional pulmonary perfusion, which correlates with several lung function parameters.


Asunto(s)
Imagen de Perfusión/métodos , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/fisiopatología , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/métodos , Volumen Sanguíneo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Eur Radiol ; 22(10): 2110-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22610534

RESUMEN

OBJECTIVE: To show the feasibility of dual-energy CT (DECT) and dynamic CT for ventilation imaging of the paranasal sinuses in a nasal cast. METHODS: In a first trial, xenon gas was administered to a nasal cast with a laminar flow of 7 L/min. Dynamic CT acquisitions of the nasal cavity and the sinuses were performed. This procedure was repeated with pulsating xenon flow. Local xenon concentrations in the different compartments of the model were determined on the basis of the enhancement levels. In a second trial, DECT measurements were performed both during laminar and pulsating xenon administration and the xenon concentrations were quantified directly. RESULTS: Neither with dynamic CT nor DECT could xenon-related enhancement be detected in the sinuses during laminar airflow. Using pulsating flow, dynamic imaging showed a xenon wash-in and wash-out in the sinuses that followed a mono-exponential function with time constants of a few seconds. Accordingly, DECT revealed xenon enhancement in the sinuses only after pulsating xenon administration. CONCLUSION: The feasibility of xenon-enhanced DECT for ventilation imaging was proven in a nasal cast. The superiority of pulsating gas flow for the administration of gas or aerosolised drugs to the paranasal sinuses was demonstrated. KEY POINTS : • Ventilation of the paranasal sinuses is poorly understood. • Dual-energy CT ventilation imaging has been explored using phantom simulation. • Xenon can be seen in the paranasal sinuses using pulsating xenon flow. • Dual-energy CT uses a lower radiation dose compared with dynamic ventilation CT.


Asunto(s)
Senos Paranasales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad , Modelos Anatómicos , Respiración , Xenón
8.
Eur Radiol ; 22(2): 269-78, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21913059

RESUMEN

OBJECTIVE: To correlate a Dual Energy (DE)-based visual perfusion defect scoring system with established CT-based and clinical parameters of pulmonary embolism (PE) severity. METHODS: In 63 PE patients, DE perfusion maps were visually scored for perfusion defects (P-score). Vascular obstruction was quantified using the Mastora score. Both scores were correlated with short-axis diameters of the right and left ventricle, their ratio (RV/LV ratio), width of the pulmonary trunk, a number of clinical parameters and each other. Univariate and multivariate analyses were performed. Times to generate both scores were recorded. RESULTS: After univariate and multivariate analysis, a significant (p < 0.05) correlation with the P-score was shown for the Mastora score (r = 0.65), RV/LV ratio (r = 0.47), width of the pulmonary trunk (r = 0.26), troponin I (r = 0.43) and PaO(2) (r = -0.50). For the left ventricular diameter, only univariate analysis showed a significant correlation. Mastora score correlated significantly with RV/LV ratio (r = 0.36), width of the pulmonary trunk (r = 0.27), PaO(2) (r = -0.41) and troponin I (r = 0.37). Mean time for generating the P-score was significantly shorter than for the Mastora score. CONCLUSIONS: A DE-based P-score correlates with a number of parameters of PE severity. It might be easier and faster to perform than some traditional CT scoring methods for vascular obstruction.


Asunto(s)
Sangre/metabolismo , Cardiología/métodos , Pulmón/metabolismo , Oxígeno/metabolismo , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Derecha/metabolismo , Anciano , Medios de Contraste/farmacología , Femenino , Humanos , Yohexol/análogos & derivados , Yohexol/farmacología , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Perfusión
9.
J Magn Reson Imaging ; 34(3): 595-607, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21761461

RESUMEN

PURPOSE: To measure the systematic error in perfusion and filtration parameters derived from magnetic resonance (MR) renography caused by protein binding of MR contrast agents. MATERIALS AND METHODS: Eight healthy Danish Landrace pigs were examined with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In four pigs a bolus of gadopentetate-dimeglumine (Gd-DTPA; no protein binding) was injected, followed by gadobenate-dimeglumine (Gd-BOPTA; 10% protein binding). The order was reversed in the other four pigs. A two-compartment filtration model was generalized to allow for protein binding and fitted to whole-cortex region of interest (ROI) curves. Single-kidney plasma flow and volume, tubular flow (or GFR), and tubular transit time of both agents were compared. RESULTS: The data show a strong systematic underestimation (P < 0.001) in GFR by Gd-BOPTA (33 ± 7.2%), and no significant differences (P > 0.05) in plasma flow (2.2 ± 18%), plasma volume (-1.7 ± 7.8%) and tubular transit time (3.1 ± 7.2%). The order of injection had no significant effect. CONCLUSION: Theory and experiments agree that perfusion parameters of both agents are comparable, whereas GFR is underestimated with Gd-BOPTA due to the dependence of relaxivity on protein content. Hence, GFR cannot be measured with protein-bound contrast agents, but the proposed dual-agent protocol may produce new functional indices measuring protein filtration.


Asunto(s)
Gadolinio DTPA , Tasa de Filtración Glomerular/fisiología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos , Circulación Renal/fisiología , Animales , Velocidad del Flujo Sanguíneo , Medios de Contraste , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos
10.
Invest Radiol ; 45(5): 245-54, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20375845

RESUMEN

PURPOSE: The purpose of this study was to evaluate the feasibility of diffusion tensor imaging of the kidney at a field strength of 3T. We assessed fractional anisotropy (FA) and apparent diffusion coefficients (ADC) of various acquisition protocols and determined the reproducibility of these measurements. FA, ADC, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were compared with those acquired at 1.5T. MATERIAL AND METHODS: Ten healthy volunteers were examined with a respiratory-triggered echo-planar imaging sequence (TR: 1800 ms, TE: 58 ms, b = 0, 300 s/mm(2)) on a 3-Tesla whole-body MR scanner. Protocol variations included diffusion measurements during free-breathing, in 6 or 12 directions, and an additional b-value of 50 s/mm(2). A breath-hold protocol was also integrated (TR: 820 ms, TE: 58 ms, b = 0, 300 s/mm(2)). Measurements with 2 b-values and 6 diffusion directions were also acquired at 1.5 T. SNR was calculated with the difference-image method. Statistical analysis was performed with Wilcoxon signed-rank tests. Intrareader correlation was assessed with weighted kappa coefficients and reproducibility with the root-mean-square-average and the Bland-Altman-method. RESULTS: At 3T, SNR of cortex and medulla and CNR of cortex/medulla were significantly higher than at 1.5T, leading to improved corticomedullary discrimination. There were no significant FA- and ADC differences with 2 b-values and 6 diffusion directions between measurements at 1.5T and 3T. FA of the medulla was significantly higher than that of the cortex in all measurements. Tractography visualized a typical radial diffusion direction in the medulla. Best image quality was achieved with a respiratory triggered protocol with 12 acquisition directions. Measurements with 3 b-values led to decreased ADCs. Acquisition in 12 directions resulted in decreased cortical FA. FA and ADC of breath-hold and free-breathing acquisitions were significantly higher than that of the respiratory-triggered protocol. Intrareader correlation ranged from kappa 0.60 to 0.96. Variance of the respiratory-triggered protocol was smaller than that of breath-hold and free-breathing protocols. Variance was highest for medullary FA in all protocols with reproducibility coefficients ranging from 0.36 to 0.46. CONCLUSION: Diffusion tensor imaging of the kidney at 3T is feasible and yields significantly higher SNR and CNR. FA and ADCs do not significantly differ from 1.5T. Number of b-values influences ADC-values. Acquisitions in 12 directions provide lower cortical FA-values. We recommend a respiratory-triggered protocol because of improved image quality and reproducibility.


Asunto(s)
Imagen de Difusión Tensora/métodos , Riñón/anatomía & histología , Adulto , Anisotropía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Fenómenos Fisiológicos Respiratorios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...