Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Nutrients ; 16(2)2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38257177

RESUMEN

Obesity is a pediatric epidemic that is more prevalent in children with developmental disabilities. We hypothesize that soy protein-based diets increase weight gain and alter neurobehavioral outcomes. Our objective herein was to test matched casein- and soy protein-based purified ingredient diets in a mouse model of fragile X syndrome, Fmr1KO mice. The experimental methods included assessment of growth; 24-7 activity levels; motor coordination; learning and memory; blood-based amino acid, phytoestrogen and glucose levels; and organ weights. The primary outcome measure was body weight. We find increased body weight in male Fmr1KO from postnatal day 6 (P6) to P224, male wild type (WT) from P32-P39, female Fmr1KO from P6-P18 and P168-P224, and female Fmr1HET from P9-P18 as a function of soy. Activity at the beginning of the light and dark cycles increased in female Fmr1HET and Fmr1KO mice fed soy. We did not find significant differences in rotarod or passive avoidance behavior as a function of genotype or diet. Several blood-based amino acids and phytoestrogens were significantly altered in response to soy. Liver weight was increased in WT and adipose tissue in Fmr1KO mice fed soy. Activity levels at the beginning of the light cycle and testes weight were greater in Fmr1KO versus WT males irrespective of diet. DEXA analysis at 8-months-old indicated increased fat mass and total body area in Fmr1KO females and lean mass and bone mineral density in Fmr1KO males fed soy. Overall, dietary consumption of soy protein isolate by C57BL/6J mice caused increased growth, which could be attributed to increased lean mass in males and fat mass in females. There were sex-specific differences with more pronounced effects in Fmr1KO versus WT and in males versus females.


Asunto(s)
Cetonas , Proteínas de Soja , Humanos , Niño , Animales , Ratones , Femenino , Masculino , Lactante , Ratones Endogámicos C57BL , Proteínas de Soja/farmacología , Fenotipo , Genotipo , Obesidad , Proteína de la Discapacidad Intelectual del Síndrome del Cromosoma X Frágil/genética
2.
J Pediatr ; 259: 113469, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37182660

RESUMEN

OBJECTIVE: To evaluate distribution profiles of total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), and apolipoprotein B (apoB) as candidate markers of familial hypercholesterolemia in newborns, taking into consideration potential confounding factors, such as gestational age, birth weight, sex, and race. STUDY DESIGN: TC, LDL-C, and apoB were measured from 10 000 residual deidentified newborn dried blood spot cards. Concentrations for each biomarker were reported as multiples of the median, with emphasis on describing the 99th percentile values based on birth weight, gestational age, sex, and race. Seasonal variation of biomarkers was also explored. RESULTS: LDL-C and apoB had distribution curves with tails showing extreme elevation, whereas the distribution of TC was less elevated and had the smallest range. Neonates born at early gestational age and low birth weight had significantly greater 99th percentile of multiples of the median values for apoB but not TC or LDL-C. Differences in biomarker concentration based on sex and race were minimal. All biomarkers showed greatest concentrations in the winter as compared with summer months. CONCLUSIONS: LDL-C and apoB had distribution curves supporting candidacy for neonatal familial hypercholesterolemia screening. Future studies are needed to correlate newborn screening results with molecular testing to validate these 2 biomarkers, along with measured cholesterol levels later in childhood.


Asunto(s)
Hiperlipoproteinemia Tipo II , Humanos , Recién Nacido , LDL-Colesterol , Peso al Nacer , Hiperlipoproteinemia Tipo II/diagnóstico , Biomarcadores , Apolipoproteínas B
3.
Animals (Basel) ; 12(24)2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36552368

RESUMEN

Animal husbandry conditions, including rodent diet, constitute an example highlighting the importance of reporting experimental variables to enhance scientific rigor. In the present study, we examine the effects of three common rodent diets including two chows (Purina 5015 and Teklad 2019) and one purified ingredient diet (AIN-76A) on growth anthropometrics (body weight), behavior (nest building, actigraphy, passive avoidance) and blood biomarkers (ketones, glucose, amino acid profiles) in male and female C57BL/6J mice. We find increased body weight in response to the chows compared to purified ingredient diet albeit selectively in male mice. We did not find significantly altered behavior in female or male wild type C57BL/6J mice. However, amino acid profiles changed as an effect of sex and diet. These data contribute to a growing body of knowledge indicating that rodent diet impacts experimental outcomes and needs to be considered in study design and reporting.

4.
Int J Neonatal Screen ; 8(4)2022 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-36412583

RESUMEN

To improve the positive predictive value (PPV) of newborn screening for 21-hydroxylase deficiency (21OHD), co-variates have been used to modify 17-hydroxyprogesterone (17OHP) cutoffs. The objective of this study is to evaluate whether 17OHP screening cutoffs adjusted for both collection time (CT) and birth weight (BW) improved the sensitivity and PPV of 21OHD screening. Unaffected newborn screening samples were stratified based on BW and CT to establish 17OHP concentration cutoffs at the 95th and 99th percentile. These cutoffs were applied to a cohort of confirmed cases of 21OHD to determine the sensitivity and PPV of the modified screening parameters. 17OHP cutoffs at the 99th percentile, adjusted for BW and CT, had a sensitivity of 96.3% and a specificity of 98.9%, but a relatively low PPV (0.130) for the identification of 21OHD and did not detect all cases. Use of the 95th percentile further increased sensitivity to 98.1% but resulted in a notably lower PPV (0.027). Alternative approaches that do not rely exclusively on 17OHP are needed to improve newborn screening accuracy for 21OHD.

5.
Int J Neonatal Screen ; 8(1)2022 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-35225935

RESUMEN

Wisconsin's newborn screening program implemented second-tier testing on specimens with elevated propionylcarnitine (C3) to aid in the identification of newborns with propionic and methylmalonic acidemias. The differential diagnosis for elevated C3 also includes acquired vitamin B12 deficiency, which is currently categorized as a false positive screen. The goal of this study was to summarize screening data and evaluate their effectiveness at establishing diagnoses and categorizing false positive cases. All Wisconsin newborns born between 2013 and 2019 with a positive first-tier screen for C3 were included in this study. For each case the first- and second-tier newborn screening data and confirmatory test results were compiled. The clinical determination for each case was reviewed and categorized into groups: inborn error of metabolism, maternal B12 deficiency, infant B12 deficiency, and false positive. A review of the screening data showed a significant overlap in the concentration of biomarkers for newborns with genetic versus acquired disease. Additionally, a review of confirmatory test results showed incomplete ascertainment of maternal vitamin B12 status. The Wisconsin newborn screening program recommended a confirmatory testing algorithm to aid in the diagnosis of inborn errors of metabolism and acquired vitamin B12 deficiency.

6.
Int J Neonatal Screen ; 8(1)2022 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-35225936

RESUMEN

Heterozygous familial hypercholesterolemia (HeFH) is a common, treatable genetic disorder characterized by premature atherosclerosis and cardiovascular disease, yet the majority of affected individuals remain undiagnosed. Newborn screening could play a role in identification of at-risk individuals and provide an opportunity for early intervention, prior to the onset of symptoms. The objective of this study was to develop and validate assays for quantification of candidate HeFH biomarkers in dried blood spots (DBS). Commercially available enzyme assay kits for quantification of serum total cholesterol (TC) and low-density lipoprotein-cholesterol (LDL-C) were modified for high-throughput analysis of DBS. Apolipoprotein B (ApoB) concentrations in DBS were measured using an immunoassay with modifications from published studies. All three assays were validated according to the College of American Pathologists guidelines for clinical laboratories. The performance of TC, LDL-C, and ApoB assays was assessed by precision, recovery, limit of quantification (LOQ) and linearity. Precision studies yielded coefficients of variation (CV) of less than 15%, with recovery greater than 75% for all three assays. The determined LOQ and linearity were comparable to serum-based assays. In a direct comparison between serum and DBS concentrations, positive correlations were demonstrated for TC, LDL-C, and ApoB. Additionally, the initial evaluation of the three biomarker concentrations within the unaffected population was similar to values obtained in previous published studies. This study reports on methods for quantification of TC, LDL-C, and ApoB in DBS. Assay validation results were within acceptable limits for newborn screening. This is an important first step toward the identification of newborns with HeFH.

7.
J Pediatr ; 242: 213-219.e1, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34780778

RESUMEN

OBJECTIVES: To assess whether 21-deoxycortisol (21deoxy) can be used to predict 21-hydroxylase deficiency (21OHD) in newborns and to evaluate the influence of gestational age and the timing of collection on 21deoxy concentrations. STUDY DESIGN: 17-hydroxyprogesterone (17OHP) and 21deoxy levels were measured in 906 newborn screening specimens (851 unaffected newborns, 55 confirmed cases of 21OHD) to compare their ability to identify babies with 21OHD. In addition, these 2 steroids were assessed in the unaffected cohort to determine the influence of gestational age (ranging from 23 to 42 weeks) and the timing of specimen collection on the measured concentrations. RESULTS: The gestational age of the newborn impacted both 17OHP and 21deoxy concentrations, but the degree of influence was more substantial for 17OHP. Timing of collection did not affect 21deoxy concentration. Moreover, 21deoxy was a better predictor of 21OHD status compared with 17OHP, with little overlap in concentrations between the unaffected population and confirmed cases of 21OHD. A streamlined decision tree using solely 21deoxy (cutoff value, 0.85 ng/mL) yielded a 91.7% positive predictive value for 21OHD screening. CONCLUSIONS: Our findings demonstrate that 21deoxy is a key disease marker of 21OHD and can be used to improve the accuracy of newborn screening for this disorder.


Asunto(s)
Hiperplasia Suprarrenal Congénita , Cortodoxona , 17-alfa-Hidroxiprogesterona , Hiperplasia Suprarrenal Congénita/diagnóstico , Biomarcadores , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Tamizaje Neonatal
8.
Int J Neonatal Screen ; 6(3): 67, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33117906

RESUMEN

Newborn screening for 21-hydroxylase deficiency (21OHD), the most common form of congenital adrenal hyperplasia, has been performed routinely in the United States and other countries for over 20 years. Screening provides the opportunity for early detection and treatment of patients with 21OHD, preventing salt-wasting crisis during the first weeks of life. However, current first-tier screening methodologies lack specificity, leading to a large number of false positive cases, and adequate sensitivity to detect all cases of classic 21OHD that would benefit from treatment. This review summarizes the pathology of 21OHD and also the key stages of fetal hypothalamic-pituitary-adrenal axis development and adrenal steroidogenesis that contribute to limitations in screening accuracy. Factors leading to both false positive and false negative results are highlighted, along with specimen collection best practices used by laboratories in the United States and worldwide. This comprehensive review provides context and insight into the limitations of newborn screening for 21OHD for laboratorians, primary care physicians, and endocrinologists.

9.
Int J Neonatal Screen ; 6(3): 75, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33123642

RESUMEN

Newborn screening (NBS) laboratories cannot accurately compare mass spectrometry-derived results and cutoff values due to differences in testing methodologies. The objective of this study was to assess harmonization of laboratory proficiency test (PT) results using quality control (QC) data. Newborn Screening Quality Assurance Program (NSQAP) QC and PT data reported from 302 laboratories in 2019 were used to compare results among laboratories. QC materials were provided as dried blood spot cards which included a base pool and the base pool enriched with specific concentrations of metabolites in a linear range. QC data reported by laboratories were regressed on QC data reported by the Centers for Disease Control and Prevention (CDC), and laboratory's regression parameters were used to harmonize their PT result. In general, harmonization tended to reduce overall variation in PT data across laboratories. The metabolites glutarylcarnitine (C5DC), tyrosine, and phenylalanine were displayed to highlight inter- and intra-method variability in NBS results. Several limitations were identified using retrospective data for harmonization, and future studies will address these limitations to further assess feasibility of using NSQAP QC data to harmonize PT data. Harmonizing NBS data using common QC materials appears promising to aid result comparison between laboratories.

10.
J Clin Endocrinol Metab ; 105(8)2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32525982

RESUMEN

PURPOSE: Newborn screening laboratories are challenged to develop reporting algorithms that accurately identify babies at increased risk for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency (21OHD). Screening algorithms typically use cutoff values for a key steroid(s) and include considerations for covariates, such as gestational age or birth weight, but false-positive and false-negative results are still too frequent, preventing accurate assessments. Principal component analysis (PCA) is a statistical method that reduces high-dimensional data to a small number of components, capturing patterns of association that may be relevant to the outcome of interest. To our knowledge, PCA has not been evaluated in the newborn screening setting to determine whether it can improve the positive predictive value of 21OHD screening. METHODS: PCA was applied to a data set of 920 newborns with measured concentrations of 5 key steroids that are known to be perturbed in patients with 21OHD. A decision tree for the known outcomes (confirmed 21OHD cases and unaffected individuals) was created with 2 principal components as predictors. The effectiveness of the PCA-derived decision tree was compared with the current algorithm. RESULTS: PCA improved the positive predictive value of 21OHD screening from 20.0% to 66.7% in a retrospective study comparing the current algorithm to a tree-based algorithm using PCA-derived variables. The streamlined PCA-derived decision tree, comprising only 3 assessment points, greatly simplified the 21OHD reporting algorithm. CONCLUSIONS: This first report of PCA applied to newborn screening for 21OHD demonstrates enhanced detection of affected individuals within the unaffected population.


Asunto(s)
Hiperplasia Suprarrenal Congénita/diagnóstico , Técnicas de Diagnóstico Endocrino , Tamizaje Neonatal/métodos , Análisis de Componente Principal , Esteroides/sangre , Hiperplasia Suprarrenal Congénita/sangre , Algoritmos , Biomarcadores/sangre , Interpretación Estadística de Datos , Reacciones Falso Positivas , Femenino , Edad Gestacional , Humanos , Recién Nacido , Masculino , Valor Predictivo de las Pruebas , Valores de Referencia , Estudios Retrospectivos
11.
Clin Perinatol ; 47(1): 155-170, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32000923

RESUMEN

Metabolic disorders are disruptions in nutrient metabolism or basic cellular processes that can result in severe neonatal crisis. Basic laboratory findings may reveal hypoglycemia, acidosis, or hyperammonemia, but may also be normal even in infants with severe metabolic decompensation. Breast milk or milk-based formulas often contain the nutrient that precipitates the metabolic crisis and may need to be held during acute illness. Instead, infants with suspected metabolic disorders should be administered a high glucose infusion rate with isotonic fluids to reverse catabolism. Combined advanced biochemical and molecular testing is often needed to identify specific metabolic disorders and guide ongoing treatment.


Asunto(s)
Errores Innatos del Metabolismo/diagnóstico , Errores Innatos del Metabolismo/terapia , Diagnóstico Diferencial , Humanos , Recién Nacido , Tamizaje Neonatal
12.
Public Health Rep ; 134(2_suppl): 58S-63S, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31682555

RESUMEN

The Plain community is the fastest-growing religious minority in Wisconsin. This community has a high incidence of genetic disorders, many of which are identifiable through newborn screening. We describe efforts by the Wisconsin Newborn Screening Program (WNSP) to improve health care in the Plain community by targeting early identification of, and intervention for, patients with inherited metabolic disorders. WNSP formed partnerships with families and health care providers to increase awareness of screening procedures and the intended benefits of screening, modify testing algorithms to enhance detection, and establish medical homes for patients with confirmed disorders. The estimated number of Plain newborns screened increased by 25.5% during the study period, from 547 in 2011 to 736 in 2017; 122 persons underwent carrier testing, and 143 newborns received second-tier testing. From 2014 to 2017, affected patients received 71 metabolic evaluations in their community medical home without travel to major health centers. This article demonstrates how a comprehensive public health program can help increase screening rates, enhance detection, and establish follow-up care in a hard-to-reach religious community. A key lesson learned was the importance of communication among all stakeholders to develop an effective public health program.


Asunto(s)
Comunicación , Cuidados a Largo Plazo , Enfermedades Metabólicas/diagnóstico , Enfermedades Metabólicas/epidemiología , Tamizaje Neonatal , Religión , Femenino , Humanos , Incidencia , Recién Nacido , Masculino , Enfermedades Metabólicas/genética , Aceptación de la Atención de Salud/psicología , Wisconsin/epidemiología
13.
Int J Neonatal Screen ; 5(3): 33, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33072992

RESUMEN

Newborn screening for congenital adrenal hyperplasia (CAH) has one of the highest false positive rates of any of the diseases on the Wisconsin panel. This is largely due to the first-tier immune assay cross-reactivity and physiological changes in the concentration of 17-hydroxyprogesterone during the first few days of life. To improve screening for CAH, Wisconsin developed a second-tier assay to quantify four different steroids (17-hydroxyprogesterone, 21-deoxycortisol, androstenedione, and cortisol) by liquid chromatography-tandem mass spectrometry (LC-MSMS) in dried blood spots. From validation studies which included the testing of confirmed CAH patients, Wisconsin established its own reporting algorithm that incorporates steroid concentrations as well as two different ratios-the birth weight and the collection time-to identify babies at risk for CAH. Using the newly developed method and algorithm, the false positive rate for the CAH screening was reduced by 95%. Patients with both classical forms of CAH, salt-wasting and simple virilizing, were identified. This study replicates and expands upon previous work to develop a second-tier LC-MSMS steroid profiling screening assay for CAH. The validation and prospective study results provide evidence for an extensive reporting algorithm that incorporates multiple steroids, birth weight, and collection times.

14.
Mol Genet Metab Rep ; 16: 36-38, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30013935

RESUMEN

Propionic acidemia (PA) occurs at a higher incidence within the Amish; however, sensitivity of newborn screening and its impact on long-term clinical outcomes has not been reported in this population. This study reviewed screening data and health records of 20 Wisconsin Amish patients diagnosed with PA. Newborn screening did not identify all cases; however, early detection did offer appreciable long-term protection from neurological sequelae. This is the first report summarizing PA cases within the Amish.

15.
Mol Genet Metab Rep ; 6: 21-6, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27014575

RESUMEN

INTRODUCTION: Metabolic control of phenylketonuria (PKU) and compliance with the low-phenylalanine (phe) diet are frequently assessed by measuring blood phe concentrations in dried blood spots (DBS) collected by patients instead of plasma phe concentrations. OBJECTIVE: Our objective was to investigate the difference in blood phe concentrations in DBS collected by subjects and analyzed using either a validated newborn screening tandem mass spectrometry (MS/MS) protocol or ion-exchange chromatography (IEC) compared to plasma phe concentrations obtained simultaneously and analyzed using IEC. DESIGN: Three to four fasting blood samples were obtained from 29 subjects with PKU, ages 15-49 years. Capillary blood was spotted on filter paper by each subject and the DBS analyzed using both MS/MS and IEC. Plasma was isolated from venous blood and analyzed using IEC. RESULTS: Blood phe concentrations in DBS analyzed using MS/MS are 28% ± 1% (n = 110, p < 0.0001) lower than plasma phe concentrations analyzed using IEC resulting in a blood phe concentration of 514 ± 23 µmol/L and a plasma phe concentration of 731 ± 32 µmol/L (mean ± SEM). This discrepancy is larger when plasma phe is > 600 µmol/L. Due to the large variability across subjects of 13.2%, a calibration factor to adjust blood phe concentrations is not recommended. Analysis of DBS using IEC reduced the discrepancy to 15 ± 2% lower phe concentrations compared to plasma analyzed using IEC (n = 38, p = 0.0001). This suggests that a major contributor to the discrepancy in phe concentrations is the analytical method. CONCLUSION: Use of DBS analyzed using MS/MS to monitor blood phe concentrations in individuals with PKU yields significantly lower phe levels compared to plasma phe levels analyzed using IEC. Optimization of current testing methodologies for measuring phe in DBS, along with patient education regarding the appropriate technique for spotting blood on filter paper is needed to improve the accuracy of using DBS to measure phe concentrations in PKU management.

16.
Mol Genet Metab ; 116(3): 125-32, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26293295

RESUMEN

Routine second screening of most newborns at 8-14 days of life for a panel of newborn conditions occurs in 12 U.S. states, while newborns in the other states typically undergo only a single routine newborn screen. The study objective was to evaluate screening consequences for primary congenital hypothyroidism (CH) in one- and two-screen states according to laboratory practices and medical or biochemical characteristics of screen-positive cases. Individual-level medical and biochemical data were retrospectively collected and analyzed for 2251 primary CH cases in one-screen (CA, WI) and two-screen (AL, DE, MD, OR, TX) states. Aggregate data were collected and analyzed for medical and biochemical characteristics of all screened newborns in the states. Among the states evaluated in this study, the detection rate of primary CH was higher in the one-screen states. In the two-screen states, 11.5% of cases were detected on the second screen. In multivariate analyses, only race/ethnicity was a significant predictor of cases identified on the first versus second screen, which likely reflects a physiologic difference in primary CH presentation. Newborn screening programs must heed the potential for newborns with CH not being detected by a single screen, particularly newborns of certain races/ethnicities. If the two-screen states converted to a single screen using their current algorithms, newborns currently identified on the routine second screen would presumably not be detected, resulting in probable delayed diagnosis and treatment. However, based on the one-screen state experiences, with appropriate modifications in screening method and algorithm, the two-screen states might convert to single screen operation for CH without loss in performance.


Asunto(s)
Hipotiroidismo Congénito/diagnóstico , Hipotiroidismo Congénito/epidemiología , Tamizaje Neonatal/métodos , Algoritmos , Hipotiroidismo Congénito/etnología , Humanos , Recién Nacido , Estudios Retrospectivos , Estados Unidos/epidemiología
17.
Mol Genet Metab ; 116(3): 133-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26296712

RESUMEN

There is no clear consensus among state newborn screening programs on whether routine second screening of newborns identifies clinically relevant cases of congenital adrenal hyperplasia. This retrospective study evaluated laboratory practices, along with biochemical and medical characteristics of congenital adrenal hyperplasia (CAH) cases (1) detected on the first newborn screen in one-screen compared to two-screen states, and (2) detected on the first versus the second screen in the two-screen states, to determine the effectiveness of a second screen. A total of 374 confirmed cases of CAH from 2 one-screen states and 5 two-screen states were included in this study. Demographic data and diagnostic information on each reported case were collected and analyzed. Additionally, laboratory data, including screening methodologies and algorithms, were evaluated. The one-screen states reported 99 cases of CAH out of 1,740,586 (1 in 17,500) newborns screened: 88 (89%) identified on the first screen and 5 (5%) identified on the targeted second screen. The two-screen states reported 275 cases of CAH out of 2,629,627 (1 in 9500) newborns screened: 165 (60%) identified on the first screen and 99 (36%) identified on the second screen. Using a multivariate model, the only significant predictor of whether a case was identified on the first or the second screen in the two-screen states was the type of CAH. Compared with classical salt-wasting CAH, classical simple virilizing and non-classical CAH cases were less likely to be detected on the first versus the second screen. The routine second newborn screen is important for identifying children with CAH, particularly simple virilizing and non-classical forms, which might otherwise not be captured through a single screen.


Asunto(s)
Hiperplasia Suprarrenal Congénita/diagnóstico , Hiperplasia Suprarrenal Congénita/epidemiología , Tamizaje Neonatal/métodos , Algoritmos , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Estados Unidos/epidemiología
18.
Clin Chim Acta ; 436: 149-54, 2014 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-24886687

RESUMEN

BACKGROUND: Orotic aciduria in the presence of hyperammonemia is a key indicator for a defect in the urea cycle, specifically ornithine transcarbamylase (OTC) deficiency. Current newborn screening (NBS) protocols can detect several defects of the urea cycle, but screening for OTC deficiency remains a challenge due to the lack of a suitable assay. The purpose of this study was to develop a high-throughput assay to measure orotic acid in dried blood spot (DBS) specimens as an indicator for urea cycle dysfunction, which can be readily incorporated into routine NBS. METHODS: Orotic acid was extracted from DBS punches and analyzed using flow-injection analysis tandem mass spectrometry (FIA-MS/MS) with negative-mode ionization, requiring <2 min/sample run time. This method was then multiplexed into a conventional newborn screening assay for analysis of amino acids, acylcarnitines, and orotic acid. RESULTS: We describe 2 assays which can quantify orotic acid in DBS: a stand-alone method and a combined method for analysis of orotic acid, amino acids, and acylcarnitines. Both methods demonstrated orotic acid recovery of 75-85% at multiple levels of enrichment. Precision was also comparable to traditional FIA-MS/MS methods. Analysis of residual presumptively normal NBS specimens demonstrated a 5:1 signal to noise ratio and the average concentration of orotic acid was approximately 1.2 µmol/l. The concentration of amino acids and acylcarnitines as measured by the combined method showed no significant differences when compared to the conventional newborn screening assay. In addition, retrospective analysis of confirmed patients and presumptively normal newborn screening specimens suggests potential for the methods to identify patients with OTC deficiency, as well as other urea cycle defects. CONCLUSION: The assays described here quantify orotic acid in DBS using a simple extraction and FIA-MS/MS analysis procedures that can be implemented into current NBS protocols.


Asunto(s)
Aminoácidos/sangre , Carnitina/análogos & derivados , Pruebas con Sangre Seca/métodos , Ácido Orótico/sangre , Carnitina/sangre , Femenino , Análisis de Inyección de Flujo , Humanos , Lactante , Recién Nacido , Masculino , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem , Factores de Tiempo , Trastornos Innatos del Ciclo de la Urea/sangre , Trastornos Innatos del Ciclo de la Urea/diagnóstico
19.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(26): 2695-703, 2011 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-21852206

RESUMEN

Ion-exchange chromatography (IEC) is the most widely used method for amino acid analysis in physiological fluids because it provides excellent separation and reproducibility, with minimal sample preparation. The disadvantage, however, is the long analysis time needed to chromatographically resolve all the amino acids. To overcome this limitation, we evaluated a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method, which utilizes aTRAQ reagents, for amino acid analysis in urine. aTRAQ reagents tag the primary and secondary amino groups of amino acids. Internal standards for each amino acid are also labeled with a modified aTRAQ tag and are used for quantification. Separation and identification of the amino acids is achieved by liquid chromatography tandem mass spectrometry using retention times and mass transitions, unique to each amino acid, as identifiers. The run time, injection-to-injection, is 25 min, with all amino acids eluting within the first 12 min. This method has a limit of quantification (LOQ) of 1 µmol/L, and is linear up to 1000 µmol/L for most amino acids. The Coefficient of Variation (CV) was less than 20% for all amino acids throughout the linear range. Method comparison demonstrated concordance between IEC and LC-MS/MS and clinical performance was assessed by analysis of samples from patients with known conditions affecting urinary amino acid excretion. Reference intervals established for this method were also concordant with reference intervals obtained with IEC. Overall, aTRAQ reagents used in conjunction with LC-MS/MS should be considered a comparable alternative to IEC. The most attractive features of this methodology are the decreased run time and increased specificity.


Asunto(s)
Aminoácidos/orina , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aminoácidos/aislamiento & purificación , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Modelos Lineales , Errores Innatos del Metabolismo/orina , Metaboloma , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...