Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
1.
Liver Transpl ; 30(2): 151-159, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37639286

RESUMEN

Transarterial chemoembolization (TACE) and transarterial radioembolization (TARE) are the 2 most used modalities for patients with HCC while awaiting liver transplant. The purpose of this study is to perform a cost-effectiveness analysis comparing TACE and TARE for downstaging (DS) patients with HCC. A cost-effectiveness analysis was performed comparing TACE and TARE in DS HCC over a 5-year time horizon from a payer's perspective. The clinical course, including those who achieved successful DS leading to liver transplant and those who failed DS with possible disease progression, was obtained from the United Network for Organ Sharing. Costs and effectiveness were measured in US dollars and quality-adjusted life years (QALYs). Probabilistic and deterministic sensitivity analyses were performed. TARE achieved a higher effectiveness of 2.51 QALY (TACE: 2.29 QALY) at a higher cost of $172,162 (TACE: $159,706), with the incremental cost-effectiveness ratio of $55,964/QALY, making TARE the more cost-effective strategy. The difference in outcome was equivalent to 104 days (nearly 3.5 months) in compensated cirrhosis state. Probabilistic sensitivity analyses showed that TARE was more cost-effective in 91.69% of 10,000 Monte Carlo simulations. TARE was more effective if greater than 48.2% of patients who received TACE or TARE were successfully downstaged (base case: 74.6% from the pooled analysis of multiple published cohorts). TARE became more cost-effective when the cost of TACE exceeded $4,831 (base case: $12,722) or when the cost of TARE was lower than $43,542 (base case: $30,609). Subgroup analyses identified TARE to be the more cost-effective strategy if the TARE cohort required 1 fewer locoregional therapy than the TACE cohort. TARE is the more cost-effective DS strategy for patients with HCC exceeding Milan criteria compared to TACE.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Trasplante de Hígado , Humanos , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Análisis de Costo-Efectividad , Trasplante de Hígado/efectos adversos , Resultado del Tratamiento
2.
Radiology ; 309(3): e230555, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38085076

RESUMEN

Background Benign prostatic hyperplasia (BPH) is a disease that affects millions of U.S. men and is costly to treat. Purpose To compare the cost-effectiveness of four minimally invasive therapies (MITs) and medical management for the treatment of BPH. Materials and Methods A cost-effectiveness analysis from a payer's perspective with Markov modeling was performed, comparing prostatic artery embolization (PAE), prostatic urethral lift, aquablation, water vapor thermal therapy, and medical management for BPH spanning a time horizon of 5 years. The model incorporated the probability of procedural complications and recurrent symptoms necessitating retreatment, which were extracted from published studies with long-term follow-up. Costs were based on Medicare reimbursements using CPT codes for ambulatory surgery centers. Outcomes were measured using the quality-adjusted life year (QALY), incorporating both life quality and expectancy. Statistical analyses included a base case calculation (using the most probable value of each parameter) and probabilistic and deterministic sensitivity analyses. Results In the base case calculation, outcomes for the strategies were comparable, with a difference of 0.030 QALY (11 days of life in perfect health) between the most (PAE) and least (medical management) effective strategies. PAE was the most cost-effective strategy relative to medical management, with an incremental cost-effectiveness ratio of $64 842 per QALY. Probabilistic sensitivity analysis showed PAE was more cost-effective compared with prostatic urethral lift, aquablation, water vapor therapy, and medical management in pairwise comparisons. In sensitivity analysis of retreatment risk, PAE remained the most cost-effective strategy until its repeat treatment rates exceeded 2.30% per 6 months, at which point water vapor therapy became the optimal choice. PAE was the most cost-effective procedure when its procedural cost was lower than $4755. Aquablation and prostatic urethral lift became more cost-effective when their procedural costs were lower than $3015 and $1097, respectively. Conclusion This modeling-based study showed that PAE appears to be a cost-effective modality among medical management and MITs for patients with BPH, with comparable outcomes to prostatic urethral lift, water vapor therapy, and aquablation at a lower expected cost. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Gemmete in this issue.


Asunto(s)
Embolización Terapéutica , Síntomas del Sistema Urinario Inferior , Hiperplasia Prostática , Resección Transuretral de la Próstata , Estados Unidos , Masculino , Humanos , Anciano , Próstata/cirugía , Hiperplasia Prostática/cirugía , Hiperplasia Prostática/complicaciones , Análisis de Costo-Efectividad , Resección Transuretral de la Próstata/efectos adversos , Resección Transuretral de la Próstata/métodos , Embolización Terapéutica/métodos , Vapor , Medicare , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento , Síntomas del Sistema Urinario Inferior/etiología
3.
Cardiovasc Intervent Radiol ; 46(9): 1221-1230, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36977902

RESUMEN

OBJECTIVE: To compare the cost-effectiveness of drug-coated balloon angioplasty (DCB) versus plain old balloon angioplasty (POBA) for treatment of arteriovenous fistula (AVF) stenosis. METHODS: A Markov model was created to compare DCB versus POBA for AVF stenosis over a 2-year time horizon from a United States payer's perspective. Probabilities related to complications, restenosis, retreatment, and all-cause mortality were obtained from published literature. Costs were calculated using Medicare reimbursement rates and data from published cost analyses, inflation-adjusted to 2021. Health outcomes were measured with quality-adjusted life years (QALY). Probabilistic and deterministic sensitivity analyses were performed with a willingness-to-pay threshold of $100,000/QALY. RESULTS: Base case calculation showed better quality-of-life outcomes but increased cost with POBA compared to DCB, with an incremental cost-effectiveness ratio of $27,413/QALY, making POBA the more cost-effective strategy in the base case model. Sensitivity analyses showed that DCB becomes cost-effective if the 24-month mortality rate after DCB is no more than 3.4% higher than that after POBA. In secondary analyses where mortality rates were equalized, DCB was more cost-effective than POBA until its additional cost reached more than $4213 per intervention. CONCLUSION: When modeled from a payer's perspective over 2 years, the cost utility of DCB versus POBA varies with mortality outcomes. POBA is cost-effective if 2-year all-cause mortality after DCB is greater than 3.4% higher than after POBA. If 2-year mortality after DCB is less than 3.4% higher than after POBA, DCB is cost-effective until its additional cost per procedure exceeds $4213 more than POBA. LEVEL OF EVIDENCE IV: HISTORICALLY CONTROLLED STUDY.: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Asunto(s)
Angioplastia de Balón , Fístula Arteriovenosa , Enfermedad Arterial Periférica , Anciano , Humanos , Estados Unidos , Análisis Costo-Beneficio , Constricción Patológica , Resultado del Tratamiento , Medicare , Angioplastia de Balón/métodos , Materiales Biocompatibles Revestidos , Paclitaxel , Enfermedad Arterial Periférica/terapia
4.
J Vasc Interv Radiol ; 34(7): 1237-1246.e3, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36804296

RESUMEN

PURPOSE: To assess the cost effectiveness of 3 main locoregional therapies (LRTs) (transarterial chemoembolization [TACE], transarterial radioembolization [TARE], and percutaneous ablation) as bridging therapy. MATERIALS AND METHODS: A cost-effectiveness analysis was performed comparing the 3 LRTs for patients with a single hepatocellular carcinoma (HCC) with a diameter of 3 cm or less over a 5-year time horizon from a payer's perspective. The clinical courses, including transplantation, decompensation resulting in delisting, and the need for a second LRT, were based on data from the United Network for Organ Sharing (2016-2019). Costs and effectiveness were measured in U.S. dollars and quality-adjusted life-years, respectively. Probabilistic and deterministic sensitivity analyses were performed. RESULTS: A total of 2,594, 1,576, and 903 patients underwent TACE, ablation, and TARE, respectively. Ablation was the dominant strategy, with the lowest expected cost and highest effectiveness. The probabilistic sensitivity analysis demonstrated that ablation was the most cost-effective strategy in 93.9% of simulations. A subgroup analysis was performed for different wait times, with ablation remaining the most cost-effective strategy. The sensitivity analysis showed that ablation was most effective if the risk of waitlist dropout was less than 2.00% and the rate of transplantation was more than 15.1% quarterly. TARE was most effective if the risk of dropout was less than 1.19% and the rate of transplantation was more than 24.0%. TACE was most effective if the risk of dropout was less than 1.01% and the rate of transplantation was more than 45.7%. Ablation remained the most cost-effective modality until its procedural cost was more than $34,843. CONCLUSIONS: Ablation is the most cost-effective bridging strategy for patients with a single, small (≤3 cm) HCC prior to liver transplantation. The conclusion remained robust in multiple sensitivity analyses.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Trasplante de Hígado , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/métodos , Análisis de Costo-Efectividad , Quimioembolización Terapéutica/efectos adversos , Quimioembolización Terapéutica/métodos , Resultado del Tratamiento
5.
J Vasc Interv Radiol ; 34(5): 815-823.e1, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36693521

RESUMEN

PURPOSE: To determine whether transarterial radioembolization (TARE) is associated with longer survival of patients with intrahepatic cholangiocarcinoma (ICC) and whether access to TARE is influenced by socioeconomic factors. MATERIALS AND METHODS: Retrospective review of patients with ICC in the National Cancer Database from 2004 to 2018 was performed with Cox regression analysis to identify predictors of survival. Overall survival (OS) was estimated using the Kaplan-Meier method. Socioeconomic factors were compared between 2 groups using the Wilcoxon rank-sum test and χ2 test. Propensity score-matched cohorts were created between patients with ICC who did and did not undergo TARE. RESULTS: The number of patients receiving TARE for ICC increased over time from 1 in 2004 to 210 in 2018. Patients in the TARE group were more likely to be White (87.9% vs 84.3%; P = .012) and less likely to be Hispanic/Latino (7.7% vs 11.0%; P = .009). Fewer patients who underwent TARE were uninsured (0.9% vs 2.8%; P = .012). Older age, male sex, non-White race, higher tumor grade size, and stage, earlier year of diagnosis, lack of treatment with surgery or systemic therapy, and presence of lymphatic or vascular invasion exhibited significant associations with decreased survival (P < .05 for all). Patients who underwent TARE had longer survival in both unadjusted and adjusted cohorts, with an OS of 17.5 months (vs 7.2 months in the non-TARE group) after propensity matching. CONCLUSIONS: Patients with ICC who had undergone TARE experienced significantly longer survival than that experienced by those who had not after adjusting for measurable confounders. Significant socioeconomic disparities in access to TARE remain.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Humanos , Masculino , Neoplasias Hepáticas/patología , Puntaje de Propensión , Análisis de Supervivencia , Estudios Retrospectivos , Colangiocarcinoma/radioterapia , Neoplasias de los Conductos Biliares/radioterapia , Conductos Biliares Intrahepáticos , Radioisótopos de Itrio , Carcinoma Hepatocelular/patología
6.
J Vasc Interv Radiol ; 33(12): 1605-1615, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35964881

RESUMEN

PURPOSE: To compare the cost effectiveness of prostatic artery embolization (PAE) with that of transurethral resection of the prostate (TURP) for the treatment of medically refractory benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: A cost-effectiveness analysis with Markov modeling was performed, comparing the clinical course after PAE with that after TURP for 3 years. Probabilities were obtained from the available literature, and costs were based on Medicare reimbursements and published cost analyses. Outcomes were measured using quality-adjusted life-year (QALY). Statistical analyses included base case calculation, probabilistic sensitivity analysis, and deterministic sensitivity analysis to assess the robustness of the conclusion under different clinical scenarios. RESULTS: Base case calculation showed comparable outcomes (PAE, 2.845 QALY; TURP, 2.854 QALY), with a cost difference of $3,104 (PAE, $2,934; TURP, $6,038). The incremental cost-effectiveness ratio was $360,249/QALY. PAE was dominant in 23.2% and more cost effective in 48.4% of the probabilistic sensitivity analysis simulations. PAE was better if its recurrence risk was <20.4% per year and even when the TURP recurrence risk was assumed to be 0%. TURP would be more cost effective when its procedural cost was <$3,367 or the PAE procedural cost >$4,409. PAE remained cost effective when varying the risks and costs of the minor and major short-term or long-term adverse events of both procedures. TURP would be the better strategy if the utility of BPH recurrence was <0.85 QALY. CONCLUSIONS: PAE is a cost-effective strategy to treat medically refractory BPH, resulting in comparable health benefits at a lower cost than that of TURP even when accounting for extreme alterations in adverse events, costs, and recurrence rates.


Asunto(s)
Embolización Terapéutica , Hiperplasia Prostática , Resección Transuretral de la Próstata , Anciano , Estados Unidos , Masculino , Humanos , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/terapia , Resección Transuretral de la Próstata/efectos adversos , Análisis Costo-Beneficio , Próstata/irrigación sanguínea , Embolización Terapéutica/métodos , Resultado del Tratamiento , Medicare , Arterias
7.
Harm Reduct J ; 19(1): 70, 2022 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-35780103

RESUMEN

BACKGROUND: The opioid epidemic is a progressively worsening public health crisis that continues to impact healthcare system strategies such as overdose reversal and destigmatization. Even among healthcare professionals, there remains a lack of confidence in naloxone administration and a prevalence of stigma. While training can play a major impact in reducing these shortcomings, the long-term effectiveness has yet to be characterized in training healthcare professionals. This study examined the long-term retention of opioid overdose awareness and reversal training (OOART) by evaluating performance at two-time intervals, immediately post-training and at a 3-month follow-up. METHODS: Voluntary training was offered to first-year (M1) medical students at the Drexel University College of Medicine in 2021. At this training, 118 students completed training, 95 completed the post-training survey, and 42 completed the 3-month follow-up. RESULTS: Opioid reversal knowledge questions assessed significantly increased scores post-training and at the 3-month follow-up. In three of the attitude questions, scores were improved at both follow-up timepoints. In addition, three attitude questions indicating a participant's confidence to respond to an opioid overdose situation increased directly after the training, but regressed at the 3-month follow-up. The remaining questions did not show any statistical difference across the survey intervals. CONCLUSIONS: This study establishes that while OOART provides participants with the knowledge of how to respond to an opioid overdose, the retention of this knowledge at a 3-month interval is reduced. The results were mixed for longitudinal assessment of participant's attitudes toward people with opioid use disorder. Some positive increases in attitudes were retained at the 3-month interval, while others trended back toward pre-training levels. These results support the effectiveness of the training but also provide evidence that OOART must be reinforced often.


Asunto(s)
Sobredosis de Opiáceos , Estudiantes de Medicina , Analgésicos Opioides , Humanos , Estudios Longitudinales , Naloxona/uso terapéutico
8.
Electrophoresis ; 43(16-17): 1784-1798, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35753078

RESUMEN

Cancer is a highly heterogenous disease that requires precise detection tools and active surveillance methods. Liquid biopsy assays provide an agnostic way to follow the complex trajectory of cancer, providing better patient stratification tools for optimized treatment. Here, we present the development of a low-volume liquid biopsy assay called cyc-DEP (cyclic immunofluorescent imaging on dielectrophoretic chip) to profile biomarkers collected on a dielectrophoretic microfluidic chip platform. To enable on-chip cyclic imaging, we optimized a fluorophore quenching method and sequential rounds of on-chip staining with fluorescently conjugated primary antibodies. cyc-DEP allows for the quantification of a multiplex array of proteins using 25 µl of a patient plasma sample. We utilized nanoparticles from a prostate adenocarcinoma (LNCaP) cell line and a panel of six target proteins to develop our proof-of-concept technique. We then used cyc-DEP to quantify blood plasma levels of target proteins from healthy individuals, low-grade and high-grade prostate cancer patients (n = 3 each) in order to demonstrate that our platform is suitable for liquid biopsy analysis in its present form. To ensure accurate quantification of signal intensities and comparisons between different samples, we incorporated a signal intensity normalization method (fluorescent beads) and a custom signal intensity quantification algorithm that account for the distribution of signal across hundreds of collection regions on each chip. Our technique enabled a threefold improvement in multiplicity for detecting proteins associated with fluid samples, opening doors for early detection, and active surveillance through quantification of a multiplex array of biomarkers from low-volume liquid biopsies.


Asunto(s)
Bioensayo , Microfluídica , Electroforesis/métodos , Técnica del Anticuerpo Fluorescente , Humanos , Coloración y Etiquetado
9.
Cardiovasc Intervent Radiol ; 45(7): 972-982, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35292833

RESUMEN

PURPOSE: To compare the cost-effectiveness of tunneled peritoneal catheter (TPC) versus serial large-volume paracenteses (LVP) for patients with recurrent ascites. MATERIALS AND METHODS: Retrospective, single-institution analysis of 100 consecutive patients undergoing LVP and eventual TPC placement (2015-2018) was performed with extraction of procedural complications and hospital admissions. LVPs were associated with 17 adverse events (AEs) while only 9 AEs occurred after TPC placement. While undergoing routine LVP, the patients had 30 hospitalizations monthly (177 days in total) and 10 hospitalizations monthly (51 days) after TPC placement. A cost-effectiveness analysis with Markov modeling was performed comparing TPC and LVP. Costs were based on Medicare reimbursement rates. Statistical analyses include base case calculation, Monte Carlo simulations, and deterministic sensitivity analyses. RESULTS: TPC placement was the dominant strategy with a comparable health benefit of 0.08060 quality-adjusted life-years (QALY) (LVP: 0.08057 QALY) at a lower cost of $4151 (LVP: $8401). Probabilistic sensitivity analysis showed TPC was superior in 97.49% of simulations. Deterministic sensitivity analysis demonstrated the superiority of TPC compared to LVP if the TPC complication rate was < 9.47% per week and the complication rate for LVP was > 1.32% per procedure. TPC was more cost-effective when its procedural cost was < $5427 (base case: 1174.5), and remained as such when the cost of LVP was varied as much as $10,000 (base case: $316.48). CONCLUSION: In this study, TPC was more cost-effective than LVP in patients with recurrent ascites due to the reduced risk of infection, emergency department visits, and length of hospitalization stays.


Asunto(s)
Ascitis , Paracentesis , Anciano , Ascitis/complicaciones , Ascitis/terapia , Catéteres de Permanencia/efectos adversos , Análisis Costo-Beneficio , Humanos , Medicare , Paracentesis/efectos adversos , Estudios Retrospectivos , Estados Unidos
10.
Gynecol Oncol ; 164(3): 639-644, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35086684

RESUMEN

OBJECTIVE: To compare the cost-effectiveness of tunneled peritoneal catheter (TPC) versus repeated large-volume paracentesis (LVP) for patients with recurrent ascites secondary to gynecological malignancy. METHODS: A retrospective cohort study was performed at a single institution from 2016 through 2019 of patients with recurrent ascites from gynecologic malignancies that underwent either TPC or LVP. Data on procedural complications and hospital admissions were extracted. A cost-effectiveness analysis with Markov modeling was performed comparing TPC and LVP. Statistical analyses include base case calculation, Monte Carlo simulations and deterministic sensitivity analyses. RESULTS: There were no significant differences between the cohorts in the average number of hospital days (p = 0.21) or emergency department visits (p = 0.69) related to ascites. Palliative care was more often involved in the care of patients who had a TPC. The base case calculation showed TPC to be the more cost-effective strategy with a slightly lower health benefit (0.22980 versus 0.22982 QALY) and lower cost ($3043 versus $3868) relative to LVP (ICER of LVP compared to TPC: $44,863,103/QALY). Probabilistic sensitivity analysis showed TPC was the more cost-effective strategy in 8028/10,000 simulations. Deterministic sensitivity analysis showed TPC to be more cost-effective if its complication risk was >0.81% per 22 days or its procedural cost of TPC insertion was >$1997. When varying the cost of complications, TPC was more cost-effective if the cost of its complication was less than $49,202. CONCLUSIONS: TPC is the more cost-effective strategy when compared to LVP in patients with recurrent ascites from gynecological malignancy.


Asunto(s)
Neoplasias de los Genitales Femeninos , Paracentesis , Ascitis/etiología , Ascitis/terapia , Catéteres de Permanencia/efectos adversos , Análisis Costo-Beneficio , Femenino , Neoplasias de los Genitales Femeninos/complicaciones , Neoplasias de los Genitales Femeninos/terapia , Humanos , Paracentesis/efectos adversos , Estudios Retrospectivos
11.
Radiographics ; 42(1): 289-301, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34890274

RESUMEN

Roughly 37% of Americans 60 years of age and older experience chronic pain due to osteoarthritis (OA) of the knee. After conservative treatment (pharmacologic, physical therapy, and joint injections) fails, patients often require total knee arthroplasty to alleviate pain and regain knee function. Given the high economic burden of surgery paired with its invasive nature, many patients with this degenerative joint disease seek alternative treatment. Moreover, many patients with severe knee OA who also have comorbidities that preclude surgery-most often morbid obesity-are left without options. Geniculate artery embolization (GAE) is a minimally invasive intra-arterial intervention that was originally developed for the treatment of knee hemarthrosis that has recently been adapted for symptomatic knee OA. Through selective embolization of geniculate branches corresponding to the site of knee pain, GAE inhibits the neovascularity that contributes to the catabolic and inflammatory drive of OA. Preliminary trials over the past decade have demonstrated promising clinical results, including decreased pain and improved function and quality of life after treatment. Given such success, GAE provides another minimally invasive treatment option for knee OA to patients who feel reluctant to undergo or are ineligible for surgery. The authors review the radiographic manifestations and current standard of treatment of OA and hemarthrosis of the knee. Procedural technique, embolic selection, and clinical evidence for GAE in the treatment of OA and hemarthrosis of the knee are also explored. The online slide presentation from the RSNA Annual Meeting is available for this article. ©RSNA, 2021.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Arterias , Artroplastia de Reemplazo de Rodilla/efectos adversos , Hemartrosis/etiología , Hemartrosis/terapia , Humanos , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/terapia , Calidad de Vida
12.
Abdom Radiol (NY) ; 46(8): 3648-3659, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33837453

RESUMEN

The incidence of hepatocellular carcinoma continues to increase worldwide. Fortunately, there have been notable recent advances in locoregional and systemic therapy. In this current review, we will highlight these new developments and future directions of hepatocellular carcinoma treatment and address the importance of a multidisciplinary approach to treatment.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia
14.
Electrophoresis ; 42(5): 539-564, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33191521

RESUMEN

The 20th century has seen tremendous innovation of dielectrophoresis (DEP) technologies, with applications being developed in areas ranging from industrial processing to micro- and nanoscale biotechnology. From 2010 to present day, there have been 981 publications about DEP. Of over 2600 DEP patents held by the United States Patent and Trademark Office, 106 were filed in 2019 alone. This review focuses on DEP-based technologies and application developments between 2010 and 2020, with an aim to highlight the progress and to identify potential areas for future research. A major trend over the last 10 years has been the use of DEP techniques for biological and clinical applications. It has been used in various forms on a diverse array of biologically derived molecules and particles to manipulate and study them including proteins, exosomes, bacteria, yeast, stem cells, cancer cells, and blood cells. DEP has also been used to manipulate nano- and micron-sized particles in order to fabricate different structures. The next 10 years are likely to see the increase in DEP-related patent applications begin to result in a greater level of technology commercialization. Also during this time, innovations in DEP technology will likely be leveraged to continue the existing trend to further biological and medical-focused applications as well as applications in microfabrication. As a tool leveraged by engineering and imaginative scientific design, DEP offers unique capabilities to manipulate small particles in precise ways that can help solve problems and enable scientific inquiry that cannot be addressed using conventional methods.


Asunto(s)
Biotecnología , Electroforesis , Nanotecnología , Animales , Separación Celular , Células Cultivadas , Humanos , Ratones , Tamaño de la Partícula
15.
Cardiovasc Intervent Radiol ; 44(1): 127-133, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33078233

RESUMEN

PURPOSE: To characterize perceptions of palliative versus futile care in interventional radiology (IR) as a roadmap for quality improvement. METHODS: Interventional radiologists (IRs) and referring physicians were recruited for anonymous interviews and/or focus groups to discuss their perceptions and experiences related to palliative verse futile care in IR. Sessions were recorded, transcribed, and systematically analyzed using dedicated software, content analysis, and grounded theory. Data collection and analysis continued simultaneously until additional interviews stopped revealing new themes: 24 IRs (21 males, 3 females, 1-39 years of experience) and 7 referring physicians (3 males, 4 females, 6-14 years of experience) were analyzed. RESULTS: Many IRs (75%) perceived futility as an important issue. Years of experience (r = 0.60, p = 0.03) and being in academics (r = 0.62, p = 0.04) correlated with greater perceived importance. Perceptions of futility and whether a potentially inappropriate procedure was performed involved a balance between four sets of factors (patient, clinician, procedural, and cultural). These assessments tended to be qualitative in nature and are challenged by a lack of data, education, and consistent workflows. Referring clinicians were unaware of this issue and assumed IR had guidelines for differentiating between palliation and futility. CONCLUSION: This study characterized the complexity and qualitative nature of assessments of palliative verses futile care in IR while highlighting potential means of improving current practices. This is important given the number of critically ill patients referred to IR and costs of potentially inappropriate interventions.


Asunto(s)
Inutilidad Médica/psicología , Percepción , Radiólogos/psicología , Radiología Intervencionista/educación , Derivación y Consulta , Femenino , Humanos , Masculino
16.
Front Neurol ; 11: 685, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32760343

RESUMEN

Background: Technology platforms that afford biomarker discovery in patients suffering from traumatic brain injury (TBI) remain an unmet medical need. Here, we describe an observational pilot study to explore the utility of an alternating current electrokinetic (ACE) microchip device in this context. Methods: Blood samples were collected from participating subjects with and without minor TBI. Plasma levels of glial fibrillary acidic protein (GFAP), Tau, ubiquitin C-terminal hydrolase L1 (UCH-L1), and cell-free DNA (cfDNA) were determined in subjects with and without minor TBI using ACE microchip device followed by on-chip immunofluorescent analysis. Post-concussive symptoms were assessed using the Rivermead Post Concussion Symptoms Questionnaire (RPCSQ) at one-month follow-up. Results: Highest levels of GFAP, UCH-L1, and Tau were seen in two minor TBI subjects with abnormality on head computed tomography (CT). In patients without abnormal head CT, Tau and GFAP levels discriminated between plasma from minor-TBI and non-TBI patients, with sensitivity and specificity of 64-72 and 50%, respectively. Plasma GFAP, UCH-L1, and Tau strongly correlated with the cumulative RPCSQ score. Plasma UCH-L1 and GFAP exhibited highest correlation to sensitivity to noise and light (r = 0.96 and 0.91, respectively, p < 0.001). Plasma UCH-L1 and Tau showed highest correlation with headache (r = 0.74 and 0.78, respectively, p < 0.001), sleep disturbance (r = 0.69 and 0.84, respectively, p < 0.001), and cognitive symptoms, including forgetfulness (r = 0.76 and 0.74, respectively, p < 0.001), poor concentration (r = 0.68 and 0.76, respectively, p < 0.001), and time required for information processing (r = 0.77 and 0.81, respectively, p < 0.001). cfDNA exhibited a strong correlation with depression (r = 0.79, p < 0.01) and dizziness (r = 0.69, p < 0.01). While cfDNA demonstrated positive correlation with dizziness and depression (r = 0.69 and 0.79, respectively, p < 0.001), no significant correlation was observed between cumulative RPCSQ and cfDNA (r = 0.07, p = 0.81). Conclusion: We provide proof-of-principle results supporting the utility of ACE microchip for plasma biomarker analysis in patients with minor TBI.

18.
Anal Bioanal Chem ; 412(16): 3871-3880, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32277243

RESUMEN

Though the advances in microelectronic device fabrication have realized new capabilities in integrated analytical and diagnostic platforms, there are still notable limitations in point-of-care sample preparation. AC electrokinetic devices, especially those leveraging dielectrophoresis (DEP), have shown potential to solve these limitations and allow for sample-to-answer in a single point-of-care device. However, when working directly with whole blood or other high conductance (~ 1 S/m) biological fluids, the aggressive electrochemical conditions created by the electrode can fundamentally limit the device operation. In this study, platinum wire-based electrode devices spanning circular polytetrafluorethylene (PTFE) wells and a planar microarray device with sputtered platinum electrodes were tested in plasma and PBS buffers of differing concentration across a wide range of frequencies and electric field intensities (AC voltages) to determine their respective safe regions of operation and to gain an understanding about the failure mechanisms of this class of device. At frequencies of 10 kHz and below, the upper bound of operation is the degradation of electrodes due to electrochemical attack by chlorine overcoming the native platinum oxide passivation. At higher frequencies, 100 kHz and above, the dielectric loss and subsequent heating of the buffer will boil before the electrodes suffer observable damage, due to the slow irreversible reaction kinetics. Effective dielectrophoretic capture of small biological particles at these frequencies is limited, and heat/oxidative denaturation of target material are a major concern. A new class of smaller devices, ones capable of high throughput at voltages low enough to maintain the integrity of the platinum passivation layer, is needed to mitigate these fundamental limitations.


Asunto(s)
Corrosión , Electrodos , Electroforesis/instrumentación , Platino (Metal)/química , Sistemas de Atención de Punto
19.
PLoS One ; 15(2): e0229431, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32092113

RESUMEN

BACKGROUND: Current guidelines underline the importance of high-quality chest compression during cardiopulmonary resuscitation (CPR), to improve outcomes. Contrary to this many studies show that chest compression is often carried out poorly in clinical practice, and long interruptions in compression are observed. This prospective cohort study aimed to analyse whether chest compression quality changes when a real-time feedback system is used to provide simultaneous audiovisual feedback on chest compression quality. For this purpose, pauses in compression, compression frequency and compression depth were compared. METHODS: The study included 292 out-of-hospital cardiac arrests in three consecutive study groups: first group, conventional resuscitation (no-sensor CPR); second group, using a feedback sensor to collect compression depth data without real-time feedback (sensor-only CPR); and third group, with real-time feedback on compression quality (sensor-feedback CPR). Pauses and frequency were analysed using compression artefacts on electrocardiography, and compression depth was measured using the feedback sensor. With this data, various parameters were determined in order to be able to compare the chest compression quality between the three consecutive groups. RESULTS: The compression fraction increased with sensor-only CPR (group 2) in comparison with no-sensor CPR (group 1) (80.1% vs. 87.49%; P < 0.001), but there were no further differences belonging compression fraction after activation of sensor-feedback CPR (group 3) (P = 1.00). Compression frequency declined over the three study groups, reaching the guideline recommendations (127.81 comp/min vs. 122.96 comp/min, P = 0.02 vs. 119.15 comp/min, P = 0.008) after activation of sensor-feedback CPR (group 3). Mean compression depth only changed minimally with sensor-feedback (52.49 mm vs. 54.66 mm; P = 0.16), but the fraction of compressions with sufficient depth (at least 5 cm) and compressions within the recommended 5-6 cm increased significantly with sensor-feedback CPR (56.90% vs. 71.03%; P = 0.003 and 28.74% vs. 43.97%; P < 0.001). CONCLUSIONS: The real-time feedback system improved chest compression quality regarding pauses in compression and compression frequency and facilitated compliance with the guideline recommendations. Compression depth did not change significantly after activation of the real-time feedback. Even the sole use of a CPR-feedback-sensor ("sensor-only CPR") improved performance regarding pauses in compression and compression frequency, a phenomenon known as the 'Hawthorne effect'. Based on this data real-time feedback systems can be expected to raise the quality level in some parts of chest compression quality. TRIAL REGISTRATION: International Clinical Trials Registry Platform of the World Health Organisation and German Register of Clinical Trials (DRKS00009903), Registered 09 February 2016 (retrospectively registered).


Asunto(s)
Reanimación Cardiopulmonar/normas , Sistemas de Computación , Retroalimentación Sensorial , Masaje Cardíaco/normas , Paro Cardíaco Extrahospitalario/terapia , Adulto , Anciano , Anciano de 80 o más Años , Reanimación Cardiopulmonar/instrumentación , Reanimación Cardiopulmonar/métodos , Estudios de Cohortes , Cardioversión Eléctrica , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Retroalimentación Sensorial/fisiología , Femenino , Alemania , Masaje Cardíaco/instrumentación , Masaje Cardíaco/métodos , Humanos , Masculino , Persona de Mediana Edad , Presión , Mejoramiento de la Calidad , Tórax , Factores de Tiempo
20.
J Shoulder Elbow Surg ; 29(5): 946-953, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31812584

RESUMEN

BACKGROUND: Shoulder instability in young athletes is a complex problem with higher recurrence, higher reoperation, and lower return to sport (RTS) rates after arthroscopic shoulder stabilization compared with adults. METHODS: This is a prospective case series of young athletes with anterior shoulder instability after arthroscopic stabilization surgery. Primary outcomes were RTS and revision surgery, minimum follow-up was 24 months. Exclusion criteria were more than 3 preoperative episodes of instability, significant bone loss, or primary posterior instability. Demographic data, recurrent instability, revision surgery, sports pre- and postsurgery, patient satisfaction, level of RTS, time to RTS, and Single Assessment Numeric Evaluation (SANE) scores were analyzed. RESULTS: Sixty-seven athletes met inclusion criteria, 19 females and 48 males, with a mean age of 17.5 years (range, 13-21 years). Fifty-nine (88%) athletes returned to sport at an average of 7.1 months (standard deviation, ±1.8); 50 (75%) returned to the same level or higher. Football and lacrosse were the most common sports. Four of 67 athletes (6%), all male, underwent revision stabilization at 11-36 months for recurrent instability. The overall mean SANE score was 88. CONCLUSION: This study demonstrates that when the high-risk athlete, 21 years old or younger, is appropriately selected for arthroscopic shoulder stabilization by excluding those with 3 or more preoperative shoulder instability episodes and those with off-track and engaging instability patterns, excellent outcomes can be achieved with low revision surgery rates, high RTS rates, and high patient satisfaction.


Asunto(s)
Artroscopía , Inestabilidad de la Articulación/cirugía , Reoperación/estadística & datos numéricos , Volver al Deporte , Luxación del Hombro/cirugía , Articulación del Hombro/cirugía , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...