Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Magn Reson Med ; 91(2): 803-818, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37849048

RESUMEN

PURPOSE: To present a Swin Transformer-based deep learning (DL) model (SwinIR) for denoising single-delay and multi-delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) and other Transformer-based methods. METHODS: SwinIR and CNN-based spatial denoising models were developed for single-delay ASL. The models were trained on 66 subjects (119 scans) and tested on 39 subjects (44 scans) from three different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi-delay ASL. A range of input conditions was tested for denoising single and multi-delay ASL, respectively. The performance was evaluated using similarity metrics, spatial SNR and quantification accuracy of cerebral blood flow (CBF), and arterial transit time (ATT). RESULTS: SwinIR outperformed CNN and other Transformer-based networks, whereas pseudo-3D models performed better than 2D models for denoising single-delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo-3D models and further improved when using M0 as input, but introduced greater biases for CBF quantification. Pseudo-3D models with three slices achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi-delay ASL, spatiotemporal denoising models had better performance than spatial-only models with reduced biases in fitted CBF and ATT maps. CONCLUSIONS: SwinIR provided better performance than CNN and other Transformer-based methods for denoising both single and multi-delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Marcadores de Spin , Arterias , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos
3.
J Alzheimers Dis ; 96(2): 683-693, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37840499

RESUMEN

BACKGROUND: White matter hyperintensities (WMH) that occur in the setting of vascular cognitive impairment and dementia (VCID) may be dynamic increasing or decreasing volumes or stable over time. Quantifying such changes may prove useful as a biomarker for clinical trials designed to address vascular cognitive-impairment and dementia and Alzheimer's Disease. OBJECTIVE: Conducting multi-site cross-site inter-rater and test-retest reliability of the MarkVCID white matter hyperintensity growth and regression protocol. METHODS: The NINDS-supported MarkVCID Consortium evaluated a neuroimaging biomarker developed to track WMH change. Test-retest and cross-site inter-rater reliability of the protocol were assessed. Cognitive test scores were analyzed in relation to WMH changes to explore its construct validity. RESULTS: ICC values for test-retest reliability of WMH growth and regression were 0.969 and 0.937 respectively, while for cross-site inter-rater ICC values for WMH growth and regression were 0.995 and 0.990 respectively. Word list long-delay free-recall was negatively associated with WMH growth (p < 0.028) but was not associated with WMH regression. CONCLUSIONS: The present data demonstrate robust ICC validity of a WMH growth/regression protocol over a one-year period as measured by cross-site inter-rater and test-retest reliability. These data suggest that this approach may serve an important role in clinical trials of disease-modifying agents for VCID that may preferentially affect WMH growth, stability, or regression.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Demencia Vascular , Sustancia Blanca , Humanos , Sustancia Blanca/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética , Enfermedad de Alzheimer/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Biomarcadores
4.
Front Neuroinform ; 17: 1174156, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37533796

RESUMEN

The biomedical research community is motivated to share and reuse data from studies and projects by funding agencies and publishers. Effectively combining and reusing neuroimaging data from publicly available datasets, requires the capability to query across datasets in order to identify cohorts that match both neuroimaging and clinical/behavioral data criteria. Critical barriers to operationalizing such queries include, in part, the broad use of undefined study variables with limited or no annotations that make it difficult to understand the data available without significant interaction with the original authors. Using the Brain Imaging Data Structure (BIDS) to organize neuroimaging data has made querying across studies for specific image types possible at scale. However, in BIDS, beyond file naming and tightly controlled imaging directory structures, there are very few constraints on ancillary variable naming/meaning or experiment-specific metadata. In this work, we present NIDM-Terms, a set of user-friendly terminology management tools and associated software to better manage individual lab terminologies and help with annotating BIDS datasets. Using these tools to annotate BIDS data with a Neuroimaging Data Model (NIDM) semantic web representation, enables queries across datasets to identify cohorts with specific neuroimaging and clinical/behavioral measurements. This manuscript describes the overall informatics structures and demonstrates the use of tools to annotate BIDS datasets to perform integrated cross-cohort queries.

5.
Aging Dis ; 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37307817

RESUMEN

The diffusion tensor image analysis along the perivascular space (DTI-ALPS) method was proposed to evaluate glymphatic system (GS) function. However, few studies have validated its reliability and reproducibility. Fifty participants' DTI data from the MarkVCID consortium were included in this study. Two pipelines by using DSI studio and FSL software were developed for data processing and ALPS index calculation. The ALPS index was obtained by the average of bilateral ALPS index and was used for testing the cross-vendor, inter-rater and test-retest reliability by using R studio software. The ALPS index demonstrated favorable inter-scanner reproducibility (ICC=0.77 to 0.95, P < 0.001), inter-rater reliability (ICC=0.96 to 1, P< 0.001) and test-retest repeatability (ICC=0.89 to 0.95, P< 0.001), offering a potential biomarker for in vivo evaluation of GS function.

6.
medRxiv ; 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37162975

RESUMEN

Purpose: To present a Swin Transformer-based deep learning (DL) model for denoising of single-delay and multi-delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) methods. Methods: Swin Transformer and CNN-based spatial denoising models were developed for single-delay ASL. The models were trained on 59 subjects (104 scans) and tested on 44 subjects (57 scans) from 3 different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi-delay ASL. A range of input conditions was tested for denoising single and multi-delay ASL respectively. The performance was evaluated using similarity metrics, spatial signal-to-noise ratio (SNR) and quantification accuracy of cerebral blood flow (CBF) and arterial transit time (ATT). Results: Swin Transformer outperformed CNN-based networks, whereas pseudo-3D models showed better performance than 2D models for denoising single-delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo-3D models, and further improved when using M0 as input but introduced greater biases for CBF quantification. Pseudo-3D models with 3 slices as input achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi-delay, spatiotemporal denoising models had better performance than spatial-only models with reduced biases in fitted CBF and ATT maps. Conclusions: Swin Transformer DL models provided better performance than CNN methods for denoising both single and multi-delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.

7.
Lancet Neurol ; 22(7): 602-618, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37236211

RESUMEN

Cerebral small vessel disease (SVD) is common during ageing and can present as stroke, cognitive decline, neurobehavioural symptoms, or functional impairment. SVD frequently coexists with neurodegenerative disease, and can exacerbate cognitive and other symptoms and affect activities of daily living. Standards for Reporting Vascular Changes on Neuroimaging 1 (STRIVE-1) categorised and standardised the diverse features of SVD that are visible on structural MRI. Since then, new information on these established SVD markers and novel MRI sequences and imaging features have emerged. As the effect of combined SVD imaging features becomes clearer, a key role for quantitative imaging biomarkers to determine sub-visible tissue damage, subtle abnormalities visible at high-field strength MRI, and lesion-symptom patterns, is also apparent. Together with rapidly emerging machine learning methods, these metrics can more comprehensively capture the effect of SVD on the brain than the structural MRI features alone and serve as intermediary outcomes in clinical trials and future routine practice. Using a similar approach to that adopted in STRIVE-1, we updated the guidance on neuroimaging of vascular changes in studies of ageing and neurodegeneration to create STRIVE-2.


Asunto(s)
Enfermedades de los Pequeños Vasos Cerebrales , Disfunción Cognitiva , Enfermedades Neurodegenerativas , Humanos , Actividades Cotidianas , Neuroimagen , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen
8.
Alzheimers Dement (Amst) ; 14(1): e12362, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523847

RESUMEN

Introduction: To evaluate the clinical validity of free water (FW), a diffusion tensor imaging-based biomarker kit proposed by the MarkVCID consortium, by investigating the association between mean FW (mFW) and executive function. Methods: Baseline mFW was related to a baseline composite measure of executive function (EFC), adjusting for relevant covariates, in three MarkVCID sub-cohorts, and replicated in five, large, independent legacy cohorts. In addition, we tested whether baseline mFW predicted accelerated EFC score decline (mean follow-up time: 1.29 years). Results: Higher mFW was found to be associated with lower EFC scores in MarkVCID legacy and sub-cohorts (p-values < 0.05). In addition, higher baseline mFW was associated significantly with accelerated decline in EFC scores (p = 0.0026). Discussion: mFW is a sensitive biomarker of cognitive decline, providing a strong clinical rational for its use as a marker of white matter (WM) injury in multi-site observational studies and clinical trials of vascular cognitive impairment and dementia (VCID).

9.
Alzheimers Dement (Amst) ; 14(1): e12261, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35382232

RESUMEN

Introduction: To describe the protocol and findings of the instrumental validation of three imaging-based biomarker kits selected by the MarkVCID consortium: free water (FW) and peak width of skeletonized mean diffusivity (PSMD), both derived from diffusion tensor imaging (DTI), and white matter hyperintensity (WMH) volume derived from fluid attenuation inversion recovery and T1-weighted imaging. Methods: The instrumental validation of imaging-based biomarker kits included inter-rater reliability among participating sites, test-retest repeatability, and inter-scanner reproducibility across three types of magnetic resonance imaging (MRI) scanners using intra-class correlation coefficients (ICC). Results: The three biomarkers demonstrated excellent inter-rater reliability (ICC >0.94, P-values < .001), very high agreement between test and retest sessions (ICC >0.98, P-values < .001), and were extremely consistent across the three scanners (ICC >0.98, P-values < .001). Discussion: The three biomarker kits demonstrated very high inter-rater reliability, test-retest repeatability, and inter-scanner reproducibility, offering robust biomarkers suitable for future multi-site observational studies and clinical trials in the context of vascular cognitive impairment and dementia (VCID).

10.
Neuroimage ; 245: 118754, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34826595

RESUMEN

Cerebrovascular reactivity (CVR), which measures the ability of cerebral blood vessels to dilate or constrict in response to vasoactive stimuli such as CO2 inhalation, is an important index of the brain's vascular health. Quantification of CVR using BOLD MRI with hypercapnia challenge has shown great promises in research and clinical studies. However, in order for it to be used as a potential imaging biomarker in large-scale and multi-site studies, the reliability of CO2-CVR quantification across different MRI acquisition platforms and researchers/raters must be examined. The goal of this report from the MarkVCID small vessel disease biomarkers consortium is to evaluate the reliability of CO2-CVR quantification in three studies. First, the inter-rater reliability of CO2-CVR data processing was evaluated by having raters from 5 MarkVCID sites process the same 30 CVR datasets using a cloud-based CVR data processing pipeline. Second, the inter-scanner reproducibility of CO2-CVR quantification was assessed in 10 young subjects across two scanners of different vendors. Third, test-retest repeatability was evaluated in 20 elderly subjects from 4 sites with a scan interval of less than 2 weeks. In all studies, the CO2 CVR measurements were performed using the fixed inspiration method, where the subjects wore a nose clip and a mouthpiece and breathed room air and 5% CO2 air contained in a Douglas bag alternatively through their mouth. The results showed that the inter-rater CoV of CVR processing was 0.08 ± 0.08% for whole-brain CVR values and ranged from 0.16% to 0.88% in major brain regions, with ICC of absolute agreement above 0.9959 for all brain regions. Inter-scanner CoV was found to be 6.90 ± 5.08% for whole-brain CVR values, and ranged from 4.69% to 12.71% in major brain regions, which are comparable to intra-session CoVs obtained from the same scanners on the same day. ICC of consistency between the two scanners was 0.8498 for whole-brain CVR and ranged from 0.8052 to 0.9185 across major brain regions. In the test-retest evaluation, test-retest CoV across different days was found to be 18.29 ± 17.12% for whole-brain CVR values, and ranged from 16.58% to 19.52% in major brain regions, with ICC of absolute agreement ranged from 0.6480 to 0.7785. These results demonstrated good inter-rater, inter-scanner, and test-retest reliability in healthy volunteers, and suggested that CO2-CVR has suitable instrumental properties for use as an imaging biomarker of cerebrovascular function in multi-site and longitudinal observational studies and clinical trials.


Asunto(s)
Circulación Cerebrovascular , Hipercapnia/diagnóstico por imagen , Administración por Inhalación , Anciano , Envejecimiento , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Dióxido de Carbono/farmacología , Femenino , Voluntarios Sanos , Humanos , Hipercapnia/metabolismo , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Adulto Joven
11.
Alzheimers Dement ; 17(4): 716-725, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33480157

RESUMEN

The MarkVCID consortium was formed under cooperative agreements with the National Institute of Neurologic Diseases and Stroke (NINDS) and National Institute on Aging (NIA) in 2016 with the goals of developing and validating biomarkers for the cerebral small vessel diseases associated with the vascular contributions to cognitive impairment and dementia (VCID). Rigorously validated biomarkers have consistently been identified as crucial for multicenter studies to identify effective strategies to prevent and treat VCID, specifically to detect increased VCID risk, diagnose the presence of small vessel disease and its subtypes, assess prognosis for disease progression or response to treatment, demonstrate target engagement or mechanism of action for candidate interventions, and monitor disease progression during treatment. The seven project sites and central coordinating center comprising MarkVCID, working with NINDS and NIA, identified a panel of 11 candidate fluid- and neuroimaging-based biomarker kits and established harmonized multicenter study protocols (see companion paper "MarkVCID cerebral small vessel consortium: I. Enrollment, clinical, fluid protocols" for full details). Here we describe the MarkVCID neuroimaging protocols with specific focus on validating their application to future multicenter trials. MarkVCID procedures for participant enrollment; clinical and cognitive evaluation; and collection, handling, and instrumental validation of fluid samples are described in detail in a companion paper. Magnetic resonance imaging (MRI) has long served as the neuroimaging modality of choice for cerebral small vessel disease and VCID because of its sensitivity to a wide range of brain properties, including small structural lesions, connectivity, and cerebrovascular physiology. Despite MRI's widespread use in the VCID field, there have been relatively scant data validating the repeatability and reproducibility of MRI-based biomarkers across raters, scanner types, and time intervals (collectively defined as instrumental validity). The MRI protocols described here address the core MRI sequences for assessing cerebral small vessel disease in future research studies, specific sequence parameters for use across various research scanner types, and rigorous procedures for determining instrumental validity. Another candidate neuroimaging modality considered by MarkVCID is optical coherence tomography angiography (OCTA), a non-invasive technique for directly visualizing retinal capillaries as a marker of the cerebral capillaries. OCTA has theoretical promise as a unique opportunity to visualize small vessels derived from the cerebral circulation, but at a considerably earlier stage of development than MRI. The additional OCTA protocols described here address procedures for determining OCTA instrumental validity, evaluating sources of variability such as pupil dilation, and handling data to maintain participant privacy. MRI protocol and instrumental validation The core sequences selected for the MarkVCID MRI protocol are three-dimensional T1-weighted multi-echo magnetization-prepared rapid-acquisition-of-gradient-echo (ME-MPRAGE), three-dimensional T2-weighted fast spin echo fluid-attenuated-inversion-recovery (FLAIR), two-dimensional diffusion-weighted spin-echo echo-planar imaging (DWI), three-dimensional T2*-weighted multi-echo gradient echo (3D-GRE), three-dimensional T2 -weighted fast spin-echo imaging (T2w), and two-dimensional T2*-weighted gradient echo echo-planar blood-oxygenation-level-dependent imaging with brief periods of CO2 inhalation (BOLD-CVR). Harmonized parameters for each of these core sequences were developed for four 3 Tesla MRI scanner models in widespread use at academic medical centers. MarkVCID project sites are trained and certified for their instantiation of the consortium MRI protocols. Sites are required to perform image quality checks every 2 months using the Alzheimer's Disease Neuroimaging Initiative phantom. Instrumental validation for MarkVCID MRI-based biomarkers is operationally defined as inter-rater reliability, test-retest repeatability, and inter-scanner reproducibility. Assessments of these instrumental properties are performed on individuals representing a range of cerebral small vessel disease from mild to severe. Inter-rater reliability is determined by distribution of an independent dataset of MRI scans to each analysis site. Test-retest repeatability is determined by repeat MRI scans performed on individual participants on a single MRI scanner after a short (1- to 14-day) interval. Inter-scanner reproducibility is determined by repeat MRI scans performed on individuals performed across four MRI scanner models. OCTA protocol and instrumental validation The MarkVCID OCTA protocol uses a commercially available, Food and Drug Administration-approved OCTA apparatus. Imaging is performed on one dilated and one undilated eye to assess the need for dilation. Scans are performed in quadruplicate. MarkVCID project sites participating in OCTA validation are trained and certified by this biomarker's lead investigator. Inter-rater reliability for OCTA is assessed by distribution of OCTA datasets to each analysis site. Test-retest repeatability is assessed by repeat OCTA imaging on individuals on the same day as their baseline OCTA and a different-day repeat session after a short (1- to 14-day) interval. Methods were developed to allow the OCTA data to be de-identified by the sites before transmission to the central data management system. The MarkVCID neuroimaging protocols, like the other MarkVCID procedures, are designed to allow translation to multicenter trials and as a template for outside groups to generate directly comparable neuroimaging data. The MarkVCID neuroimaging protocols are available to the biomedical community and intended to be shared. In addition to the instrumental validation procedures described here, each of the neuroimaging MarkVCID kits will undergo biological validation to determine its ability to measure important aspects of VCID such as cognitive function. The analytic methods for the neuroimaging-based kits and the results of these validation studies will be published separately. The results will ultimately determine the neuroimaging kits' potential usefulness for multicenter interventional trials in small vessel disease-related VCID.


Asunto(s)
Biomarcadores , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Neuroimagen/normas , Anciano , Angiografía , Encéfalo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Tomografía de Coherencia Óptica
12.
Alzheimers Dement ; 17(4): 704-715, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33480172

RESUMEN

The concept of vascular contributions to cognitive impairment and dementia (VCID) derives from more than two decades of research indicating that (1) most older individuals with cognitive impairment have post mortem evidence of multiple contributing pathologies and (2) along with the preeminent role of Alzheimer's disease (AD) pathology, cerebrovascular disease accounts for a substantial proportion of this contribution. Contributing cerebrovascular processes include both overt strokes caused by etiologies such as large vessel occlusion, cardioembolism, and embolic infarcts of unknown source, and frequently asymptomatic brain injuries caused by diseases of the small cerebral vessels. Cerebral small vessel diseases such as arteriolosclerosis and cerebral amyloid angiopathy, when present at moderate or greater pathologic severity, are independently associated with worse cognitive performance and greater likelihood of dementia, particularly in combination with AD and other neurodegenerative pathologies. Based on this evidence, the US National Alzheimer's Project Act explicitly authorized accelerated research in vascular and mixed dementia along with frontotemporal and Lewy body dementia and AD itself. Biomarker development has been consistently identified as a key step toward translating scientific advances in VCID into effective prevention and treatment strategies. Validated biomarkers can serve a range of purposes in trials of candidate interventions, including (1) identifying individuals at increased VCID risk, (2) diagnosing the presence of cerebral small vessel disease or specific small vessel pathologies, (3) stratifying study participants according to their prognosis for VCID progression or treatment response, (4) demonstrating an intervention's target engagement or pharmacodynamic mechanism of action, and (5) monitoring disease progression during treatment. Effective biomarkers allow academic and industry investigators to advance promising interventions at early stages of development and discard interventions with low success likelihood. The MarkVCID consortium was formed in 2016 with the goal of developing and validating fluid- and imaging-based biomarkers for the cerebral small vessel diseases associated with VCID. MarkVCID consists of seven project sites and a central coordinating center, working with the National Institute of Neurologic Diseases and Stroke and National Institute on Aging under cooperative agreements. Through an internal selection process, MarkVCID has identified a panel of 11 candidate biomarker "kits" (consisting of the biomarker measure and the clinical and cognitive data used to validate it) and established a range of harmonized procedures and protocols for participant enrollment, clinical and cognitive evaluation, collection and handling of fluid samples, acquisition of neuroimaging studies, and biomarker validation. The overarching goal of these protocols is to generate rigorous validating data that could be used by investigators throughout the research community in selecting and applying biomarkers to multi-site VCID trials. Key features of MarkVCID participant enrollment, clinical/cognitive testing, and fluid biomarker procedures are summarized here, with full details in the following text, tables, and supplemental material, and a description of the MarkVCID imaging biomarker procedures in a companion paper, "MarkVCID Cerebral small vessel consortium: II. Neuroimaging protocols." The procedures described here address a range of challenges in MarkVCID's design, notably: (1) acquiring all data under informed consent and enrollment procedures that allow unlimited sharing and open-ended analyses without compromising participant privacy rights; (2) acquiring the data in a sufficiently wide range of study participants to allow assessment of candidate biomarkers across the various patient groups who might ultimately be targeted in VCID clinical trials; (3) defining a common dataset of clinical and cognitive elements that contains all the key outcome markers and covariates for VCID studies and is realistically obtainable during a practical study visit; (4) instituting best fluid-handling practices for minimizing avoidable sources of variability; and (5) establishing rigorous procedures for testing the reliability of candidate fluid-based biomarkers across replicates, assay runs, sites, and time intervals (collectively defined as the biomarker's instrumental validity). Participant Enrollment Project sites enroll diverse study cohorts using site-specific inclusion and exclusion criteria so as to provide generalizable validation data across a range of cognitive statuses, risk factor profiles, small vessel disease severities, and racial/ethnic characteristics representative of the diverse patient groups that might be enrolled in a future VCID trial. MarkVCID project sites include both prospectively enrolling centers and centers providing extant data and samples from preexisting community- and population-based studies. With approval of local institutional review boards, all sites incorporate MarkVCID consensus language into their study documents and informed consent agreements. The consensus language asks prospectively enrolled participants to consent to unrestricted access to their data and samples for research analysis within and outside MarkVCID. The data are transferred and stored as a de-identified dataset as defined by the Health Insurance Portability and Accountability Act Privacy Rule. Similar human subject protection and informed consent language serve as the basis for MarkVCID Research Agreements that act as contracts and data/biospecimen sharing agreements across the consortium. Clinical and Cognitive Data Clinical and cognitive data are collected across prospectively enrolling project sites using common MarkVCID instruments. The clinical data elements are modified from study protocols already in use such as the Alzheimer's Disease Center program Uniform Data Set Version 3 (UDS3), with additional focus on VCID-related items such as prior stroke and cardiovascular disease, vascular risk factors, focal neurologic findings, and blood testing for vascular risk markers and kidney function including hemoglobin A1c, cholesterol subtypes, triglycerides, and creatinine. Cognitive assessments and rating instruments include the Clinical Dementia Rating Scale, Geriatric Depression Scale, and most of the UDS3 neuropsychological battery. The cognitive testing requires ≈60 to 90 minutes. Study staff at the prospectively recruiting sites undergo formalized training in all measures and review of their first three UDS3 administrations by the coordinating center. Collection and Handling of Fluid Samples Fluid sample types collected for MarkVCID biomarker kits are serum, ethylenediaminetetraacetic acid-plasma, platelet-poor plasma, and cerebrospinal fluid (CSF) with additional collection of packed cells to allow future DNA extraction and analyses. MarkVCID fluid guidelines to minimize variability include fasting morning fluid collections, rapid processing, standardized handling and storage, and avoidance of CSF contact with polystyrene. Instrumental Validation for Fluid-Based Biomarkers Instrumental validation of MarkVCID fluid-based biomarkers is operationally defined as determination of intra-plate and inter-plate repeatability, inter-site reproducibility, and test-retest repeatability. MarkVCID study participants both with and without advanced small vessel disease are selected for these determinations to assess instrumental validity across the full biomarker assay range. Intra- and inter-plate repeatability is determined by repeat assays of single split fluid samples performed at individual sites. Inter-site reproducibility is determined by assays of split samples distributed to multiple sites. Test-retest repeatability is determined by assay of three samples acquired from the same individual, collected at least 5 days apart over a 30-day period and assayed on a single plate. The MarkVCID protocols are designed to allow direct translation of the biomarker validation results to multicenter trials. They also provide a template for outside groups to perform analyses using identical methods and therefore allow direct comparison of results across studies and centers. All MarkVCID protocols are available to the biomedical community and intended to be shared. In addition to the instrumental validation procedures described here, each of the MarkVCID kits will undergo biological validation to determine whether the candidate biomarker measures important aspects of VCID such as cognitive function. Analytic methods and results of these validation studies for the 11 MarkVCID biomarker kits will be published separately. The results of this rigorous validation process will ultimately determine each kit's potential usefulness for multicenter interventional trials aimed at preventing or treating small vessel disease related VCID.


Asunto(s)
Biomarcadores , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico , Disfunción Cognitiva/diagnóstico , Selección de Paciente , Proyectos de Investigación , Anciano , Demencia/etiología , Progresión de la Enfermedad , Femenino , Humanos , Difusión de la Información , Masculino , Pruebas Neuropsicológicas , Accidente Cerebrovascular/etiología
13.
Front Neurosci ; 12: 133, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29568257

RESUMEN

As the sharing of data is mandated by funding agencies and journals, reuse of data has become more prevalent. It becomes imperative, therefore, to develop methods to characterize the similarity of data. While users can group data based on the acquisition parameters stored in the file headers, these gives no indication whether a file can be combined with other data without increasing the variance in the data set. Methods have been implemented that characterize the signal-to-noise ratio or identify signal drop-outs in the raw image files, but potential users of data often have access to calculated metric maps and these are more difficult to characterize and compare. Here we describe a histogram-distance-based method applied to diffusion metric maps of fractional anisotropy and mean diffusivity that were generated using data extracted from a repository of clinically-acquired MRI data. We describe the generation of the data set, the pitfalls specific to diffusion MRI data, and the results of the histogram distance analysis. We find that, in general, data from GE scanners are less similar than are data from Siemens scanners. We also find that the distribution of distance metric values is not Gaussian at any selection of the acquisition parameters considered here (field strength, number of gradient directions, b-value, and vendor).

14.
Sci Data ; 3: 160102, 2016 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-27922621

RESUMEN

Only a tiny fraction of the data and metadata produced by an fMRI study is finally conveyed to the community. This lack of transparency not only hinders the reproducibility of neuroimaging results but also impairs future meta-analyses. In this work we introduce NIDM-Results, a format specification providing a machine-readable description of neuroimaging statistical results along with key image data summarising the experiment. NIDM-Results provides a unified representation of mass univariate analyses including a level of detail consistent with available best practices. This standardized representation allows authors to relay methods and results in a platform-independent regularized format that is not tied to a particular neuroimaging software package. Tools are available to export NIDM-Result graphs and associated files from the widely used SPM and FSL software packages, and the NeuroVault repository can import NIDM-Results archives. The specification is publically available at: http://nidm.nidash.org/specs/nidm-results.html.


Asunto(s)
Mapeo Encefálico/estadística & datos numéricos , Encéfalo/fisiología , Difusión de la Información/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Interpretación Estadística de Datos , Humanos , Almacenamiento y Recuperación de la Información , Modelos Lineales , Metaanálisis como Asunto , Reproducibilidad de los Resultados
15.
Tomography ; 2(4): 396-405, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28105469

RESUMEN

Previous research has shown that system-dependent gradient nonlinearity (GNL) introduces a significant spatial bias (nonuniformity) in apparent diffusion coefficient (ADC) maps. Here, the feasibility of centralized retrospective system-specific correction of GNL bias for quantitative diffusion-weighted imaging (DWI) in multisite clinical trials is demonstrated across diverse scanners independent of the scanned object. Using corrector maps generated from system characterization by ice-water phantom measurement completed in the previous project phase, GNL bias correction was performed for test ADC measurements from an independent DWI phantom (room temperature agar) at two offset locations in the bore. The precomputed three-dimensional GNL correctors were retrospectively applied to test DWI scans by the central analysis site. The correction was blinded to reference DWI of the agar phantom at magnet isocenter where the GNL bias is negligible. The performance was evaluated from changes in ADC region of interest histogram statistics before and after correction with respect to the unbiased reference ADC values provided by sites. Both absolute error and nonuniformity of the ADC map induced by GNL (median, 12%; range, -35% to +10%) were substantially reduced by correction (7-fold in median and 3-fold in range). The residual ADC nonuniformity errors were attributed to measurement noise and other non-GNL sources. Correction of systematic GNL bias resulted in a 2-fold decrease in technical variability across scanners (down to site temperature range). The described validation of GNL bias correction marks progress toward implementation of this technology in multicenter trials that utilize quantitative DWI.

16.
Magn Reson Med ; 75(3): 1312-23, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25940607

RESUMEN

PURPOSE: Characterize system-specific bias across common magnetic resonance imaging (MRI) platforms for quantitative diffusion measurements in multicenter trials. METHODS: Diffusion weighted imaging (DWI) was performed on an ice-water phantom along the superior-inferior (SI) and right-left (RL) orientations spanning ± 150 mm. The same scanning protocol was implemented on 14 MRI systems at seven imaging centers. The bias was estimated as a deviation of measured from known apparent diffusion coefficient (ADC) along individual DWI directions. The relative contributions of gradient nonlinearity, shim errors, imaging gradients, and eddy currents were assessed independently. The observed bias errors were compared with numerical models. RESULTS: The measured systematic ADC errors scaled quadratically with offset from isocenter, and ranged between -55% (SI) and 25% (RL). Nonlinearity bias was dependent on system design and diffusion gradient direction. Consistent with numerical models, minor ADC errors (± 5%) due to shim, imaging and eddy currents were mitigated by double echo DWI and image coregistration of individual gradient directions. CONCLUSION: The analysis confirms gradient nonlinearity as a major source of spatial DW bias and variability in off-center ADC measurements across MRI platforms, with minor contributions from shim, imaging gradients and eddy currents. The developed protocol enables empiric description of systematic bias in multicenter quantitative DWI studies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/instrumentación , Imagen de Difusión por Resonancia Magnética/métodos , Estudios Multicéntricos como Asunto/normas , Dinámicas no Lineales , Fantasmas de Imagen , Sesgo
17.
J Neurosurg ; 121(6): 1331-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25280091

RESUMEN

Current research on concussion is primarily focused on injury identification and treatment. Prevention initiatives are, however, important for reducing the incidence of brain injury. This report examines the development and implementation of an interactive electronic teaching program (an e-module) that is designed specifically for concussion education within an adolescent population. This learning tool and the accompanying consolidation rubric demonstrate that significant engagement occurs in addition to the knowledge gained among participants when it is used in a school curriculum setting.


Asunto(s)
Traumatismos en Atletas/diagnóstico , Traumatismos en Atletas/prevención & control , Conmoción Encefálica/diagnóstico , Conmoción Encefálica/prevención & control , Educación en Salud/métodos , Educación y Entrenamiento Físico/métodos , Adolescente , Traumatismos en Atletas/epidemiología , Conmoción Encefálica/epidemiología , Niño , Curriculum , Educación en Salud/organización & administración , Conocimientos, Actitudes y Práctica en Salud , Humanos , Incidencia , Educación y Entrenamiento Físico/organización & administración , Servicios de Salud Escolar/organización & administración
18.
J Neurosurg ; 120(4): 873-81, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24490785

RESUMEN

OBJECT: Concussion is a common injury in ice hockey and a health problem for the general population. Traumatic axonal injury has been associated with concussions (also referred to as mild traumatic brain injuries), yet the pathological course that leads from injury to recovery or to long-term sequelae is still not known. This study investigated the longitudinal course of concussion by comparing diffusion MRI (dMRI) scans of the brains of ice hockey players before and after a concussion. METHODS: The 2011-2012 Hockey Concussion Education Project followed 45 university-level ice hockey players (both male and female) during a single Canadian Interuniversity Sports season. Of these, 38 players had usable dMRI scans obtained in the preseason. During the season, 11 players suffered a concussion, and 7 of these 11 players had usable dMRI scans that were taken within 72 hours of injury. To analyze the data, the authors performed free-water imaging, which reflects an increase in specificity over other dMRI analysis methods by identifying alterations that occur in the extracellular space compared with those that occur in proximity to cellular tissue in the white matter. They used an individualized approach to identify alterations that are spatially heterogeneous, as is expected in concussions. RESULTS: Paired comparison of the concussed players before and after injury revealed a statistically significant (p < 0.05) common pattern of reduced free-water volume and reduced axial and radial diffusivities following elimination of free-water. These free-water-corrected measures are less affected by partial volumes containing extracellular water and are therefore more specific to processes that occur within the brain tissue. Fractional anisotropy was significantly increased, but this change was no longer significant following the free-water elimination. CONCLUSIONS: Concussion during ice hockey games results in microstructural alterations that are detectable using dMRI. The alterations that the authors found suggest decreased extracellular space and decreased diffusivities in white matter tissue. This finding might be explained by swelling and/or by increased cellularity of glia cells. Even though these findings in and of themselves cannot determine whether the observed microstructural alterations are related to long-term pathology or persistent symptoms, they are important nonetheless because they establish a clearer picture of how the brain responds to concussion.


Asunto(s)
Traumatismos en Atletas/patología , Conmoción Encefálica/patología , Encéfalo/patología , Hockey/lesiones , Fibras Nerviosas Mielínicas/patología , Adolescente , Adulto , Canadá , Femenino , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino
19.
J Neurosurg ; 120(4): 864-72, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24490839

RESUMEN

OBJECT: Concussion, or mild traumatic brain injury (mTBI), is a commonly occurring sports-related injury, especially in contact sports such as hockey. Cerebral microbleeds (CMBs), which appear as small, hypointense lesions on T2*-weighted images, can result from TBI. The authors use susceptibility-weighted imaging (SWI) to automatically detect small hypointensities that may be subtle signs of chronic and acute damage due to both subconcussive and concussive injury. The goal was to investigate how the burden of these hypointensities changes over time, over a playing season, and postconcussion, in comparison with subjects who did not suffer a medically observed and diagnosed concussion. METHODS: Images were obtained in 45 university-level adult male and female ice hockey players before and after a single Canadian Interuniversity Sports season. In addition, 11 subjects (5 men and 6 women) underwent imaging at 72 hours, 2 weeks, and 2 months after concussion. To identify subtle changes in brain tissue and potential CMBs, nonvessel clusters of hypointensities on SWI were automatically identified, and a hypointensity burden index was calculated for all subjects at the beginning of the season (BOS), the end of the season (EOS), and at postconcussion time points (where applicable). RESULTS: A statistically significant increase in the hypointensity burden, relative to the BOS, was observed for male subjects with concussions at the 2-week postconcussion time point. A smaller, nonsignificant rise in the burden for female subjects with concussions was also observed within the same time period. There were no significant changes in burden for nonconcussed subjects of either sex between the BOS and EOS time points. However, there was a statistically significant difference in the burden between male and female subjects in the nonconcussed group at both the BOS and EOS time points, with males having a higher burden. CONCLUSIONS: This method extends the utility of SWI from the enhancement and detection of larger (> 5 mm) CMBs, which are often observed in more severe cases of TBI, to cases involving smaller lesions in which visual detection of injury is difficult. The hypointensity burden metric proposed here shows statistically significant changes over time in the male subjects. A smaller, nonsignificant increase in the burden metric was observed in the female subjects.


Asunto(s)
Traumatismos en Atletas/diagnóstico , Conmoción Encefálica/diagnóstico , Encéfalo/patología , Hockey/lesiones , Hemorragias Intracraneales/diagnóstico , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Pruebas Neuropsicológicas , Factores de Riesgo , Factores Sexuales
20.
J Neurosurg ; 120(4): 882-90, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24471841

RESUMEN

OBJECT: The aim of this study was to examine the brain's white matter microstructure by using MR diffusion tensor imaging (DTI) in ice hockey players with a history of clinically symptomatic concussion compared with players without a history of concussion. METHODS: Sixteen players with a history of concussion (concussed group; mean age 21.7 ± 1.5 years; 6 female) and 18 players without a history of concussion (nonconcussed group; mean age 21.3 ± 1.8 years, 10 female) underwent 3-T DTI at the end of the 2011-2012 Canadian Interuniversity Sports ice hockey season. Tract-based spatial statistics (TBSS) was used to test for group differences in fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), and the measure "trace," or mean diffusivity. Cognitive evaluation was performed using the Immediate Postconcussion Assessment and Cognitive Test (ImPACT) and the Sport Concussion Assessment Tool-2 (SCAT2). RESULTS: TBSS revealed a significant increase in FA and AD, and a significant decrease in RD and trace in several brain regions in the concussed group, compared with the nonconcussed group (p < 0.05). The regions with increased FA and decreased RD and trace included the right posterior limb of the internal capsule, the right corona radiata, and the right temporal lobe. Increased AD was observed in a small area in the left corona radiata. The DTI measures correlated with neither the ImPACT nor the SCAT2 scores. CONCLUSIONS: The results of the current study indicate that a history of concussion may result in alterations of the brain's white matter microstructure in ice hockey players. Increased FA based on decreased RD may reflect neuroinflammatory or neuroplastic processes of the brain responding to brain trauma. Future studies are needed that include a longitudinal analysis of the brain's structure and function following a concussion to elucidate further the complex time course of DTI changes and their clinical meaning.


Asunto(s)
Conmoción Encefálica/fisiopatología , Encéfalo/fisiopatología , Hockey/lesiones , Fibras Nerviosas Mielínicas/fisiología , Adulto , Anisotropía , Imagen de Difusión Tensora , Femenino , Humanos , Cápsula Interna/lesiones , Cápsula Interna/fisiopatología , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...