Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Antiviral Res ; 216: 105670, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37451630

RESUMEN

The hepatitis E virus (HEV) is a major cause of hepatitis, with an estimated 3.3 million symptomatic cases annually. There is no HEV-specific treatment besides the off-label use of ribavirin and a vaccine is only available in China and Pakistan. To aid the development of therapeutic and preventive strategies, there is a need for convenient HEV infection models in small laboratory animals. To this end, we make use of the rat hepatitis E virus. Human infections with this virus have been reported in recent years, making it a relevant pathogen for the establishment of a small animal infection model. We here report that oral gavage of a feces suspension, containing a pre-defined viral RNA load, results in a reproducible synchronized infection in athymic nude rats. This route of administration mimics fecal-oral transmission in a standardized fashion. The suitability of the model to study the effect of antiviral drugs was assessed by using ribavirin, which significantly reduced viral loads in the feces, liver, and other tissues.


Asunto(s)
Virus de la Hepatitis E , Hepatitis E , Animales , Ratas , Humanos , Antivirales/farmacología , Antivirales/uso terapéutico , Ribavirina/farmacología , Ribavirina/uso terapéutico , Hepatitis E/tratamiento farmacológico , ARN Viral/genética , Heces
2.
Hum Mol Genet ; 27(7): 1276-1289, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-29415125

RESUMEN

Amyotrophic lateral sclerosis (ALS) is a fatal degenerative motor neuron disorder of which the progression is influenced by several disease-modifying factors. Here, we investigated ELP3, a subunit of the elongator complex that modifies tRNA wobble uridines, as one of such ALS disease modifiers. ELP3 attenuated the axonopathy of a mutant SOD1, as well as of a mutant C9orf72 ALS zebrafish model. Furthermore, the expression of ELP3 in the SOD1G93A mouse extended the survival and attenuated the denervation in this model. Depletion of ELP3 in vitro reduced the modified tRNA wobble uridine mcm5s2U and increased abundance of insoluble mutant SOD1, which was reverted by exogenous ELP3 expression. Interestingly, the expression of ELP3 in the motor cortex of ALS patients was reduced and correlated with mcm5s2U levels. Our results demonstrate that ELP3 is a modifier of ALS and suggest a link between tRNA modification and neurodegeneration.


Asunto(s)
Esclerosis Amiotrófica Lateral , Histona Acetiltransferasas , Corteza Motora/metabolismo , Proteínas del Tejido Nervioso , ARN de Transferencia , Esclerosis Amiotrófica Lateral/genética , Esclerosis Amiotrófica Lateral/metabolismo , Animales , Proteína C9orf72/genética , Proteína C9orf72/metabolismo , Histona Acetiltransferasas/genética , Histona Acetiltransferasas/metabolismo , Proteínas del Tejido Nervioso/genética , Proteínas del Tejido Nervioso/metabolismo , Procesamiento Postranscripcional del ARN , ARN de Transferencia/genética , ARN de Transferencia/metabolismo , Superóxido Dismutasa-1/genética , Superóxido Dismutasa-1/metabolismo , Pez Cebra
3.
Talanta ; 162: 268-277, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27837829

RESUMEN

A specific and sensitive capillary liquid chromatography-ultraviolet detection (cap-LC-UV) method in combination with a micro-extraction by packed sorbent (MEPS) sample clean-up procedure has been developed and validated for the simultaneous analysis of chlorpromazine, olanzapine and their flavin-containing monooxygenase (FMO) mediated N-oxides in rat brain microdialysates. Chromatographic separation was obtained on an Acclaim Pepmap RP C18 column with an ID of 300µm. An injection volume of 20µL was used to inject the largely aqueous samples and was shown to have no influence on the obtained peak shape of the compounds of interest. Optimal conditions for MEPS extraction were obtained on a mixed-mode M1 (80% C8, 20% SCX) cartridge after diluting microdialysate samples with phosphate buffer pH 2.5 (1:3 v/v). The method was validated and lower limits of quantification (LLOQ) were determined at 0.5nM for all compounds. Linearity was demonstrated between the LLOQ and 1µM for all compounds (R2>0.995). MEPS recoveries were between 92% and 98%, with intra- and interday variabilities below 15%. The applicability of the developed method was successfully demonstrated by analysing rat brain microdialysates. The capillary LC-UV method in combination with MEPS sample treatment provides a simple, sensitive method to quantify all compounds of interest in 45min and can be applied for routine therapeutic monitoring and pharmacokinetic studies of olanzapine, chlorpromazine and their respective N-oxides.


Asunto(s)
Benzodiazepinas/análisis , Encéfalo/metabolismo , Clorpromazina/análisis , Cromatografía Líquida de Alta Presión/métodos , Soluciones para Diálisis/química , Animales , Antipsicóticos/análisis , Antipsicóticos/farmacocinética , Benzodiazepinas/farmacocinética , Clorpromazina/farmacocinética , Masculino , Microdiálisis/métodos , Olanzapina , Oxidación-Reducción , Óxidos/análisis , Oxigenasas/metabolismo , Ratas Wistar , Reproducibilidad de los Resultados
4.
Eur J Pharm Sci ; 86: 13-9, 2016 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-26928721

RESUMEN

Quality control of hospital pharmacy formulations is of the utmost importance to ensure constant quality and to avoid potential mistakes before administration to the patient. In this study we investigated the applicability of refractometry as a fast, inexpensive and easy-to-use quality control measurement. Refractive indices (RI) of a multitude of different hospital formulations with varying concentrations of active compound were measured. The samples consisted of a number of binary aqueous solutions (one compound in water), complex aqueous solutions (multiple compounds in water or in a constant matrix), two suspensions and one emulsion. For all these formulations, linear regression analysis was performed, quality control limits determined and accuracy and repeatability were checked. Subsequently, actual hospital pharmacy samples were analyzed to check whether they were within the specified limits. For both binary and complex aqueous formulations, repeatability was good and a linear correlation for all samples could be observed on condition that the concentration of the active compound was sufficiently high. The refractometer was not sensitive enough for solutions of folic acid and levothyroxine, which had too low a concentration of active compound. Due to lack of homogeneity and light scattering, emulsions and suspensions do not seem suitable for quality control by refractometry. A mathematical equation was generated to predict the refractive index of an aqueous solution containing clonidine HCl as active compound. Values calculated from the equation were compared with measured values and deviations of all samples were found to be lower than 1.3%. In order to use refractometry in a hospital pharmacy for quality control of multicomponent samples, additional intermediate measurements would be required, to overcome the fact that refractometry is not compound specific. In conclusion, we found that refractometry could potentially be useful for daily, fast quality measurements of relatively concentrated binary and more complex aqueous solutions in the hospital pharmacy.


Asunto(s)
Preparaciones Farmacéuticas/análisis , Servicio de Farmacia en Hospital , Control de Calidad , Soluciones/análisis , Refractometría
5.
Bioanalysis ; 7(22): 2927-45, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26563868

RESUMEN

Hydrophilic interaction chromatography (HILIC) is being increasingly used for the analysis of hydrophilic compounds in biological matrices. The complexity of biological samples demands adequate sample preparation procedures, specifically adjusted for HILIC analyses. Currently, most bioanalytical assays are performed on bare silica and ZIC-HILIC columns. Trends in HILIC for bioanalysis include smaller particle sizes and miniaturization of the analytical column. For complex biological samples, multidimensional techniques can separate and identify more compounds than 1D separations. The high volatility of the mobile phase, the added separation power and high sensitivity make MS the detection method of choice for bioanalysis using HILIC, although other detectors such as evaporative light scattering detection, charged aerosol detection and nuclear magnetic resonance have been reported.


Asunto(s)
Productos Biológicos/análisis , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas
6.
Methods Mol Biol ; 1274: 3-17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25673478

RESUMEN

This chapter is intended as a basic introduction to microchip-based capillary electrophoresis to set the scene for newcomers and give pointers to reference material. An outline of some commonly used setups and key concepts is given, many of which are explored in greater depth in later chapters.


Asunto(s)
Electroforesis por Microchip/métodos , Electroforesis Capilar/métodos , Humanos , Análisis por Micromatrices/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...