Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eng Life Sci ; 19(10): 681-690, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32624961

RESUMEN

Monoclonal antibodies have become an increasingly important part of fundamental research and medical applications. To meet the high market demand for monoclonal antibodies in the biopharmaceutical sector, industrial manufacturing needs to be achieved by large scale, highly productive and consistent production processes. These are subject to international guidelines and have to be monitored intensely due to high safety standards for medical applications. Surface plasmon resonance spectroscopy - a fast, real-time, and label-free bio-sensing method - represents an interesting alternative to the quantification of monoclonal antibody concentrations by enzyme-linked immunosorbent assay during monoclonal antibody production. For the application of monitoring bioactive and total monoclonal antibody concentrations in cell culture samples, a surface plasmon resonance assay using a target-monoclonal antibody model system was developed. In order to ensure the subsequent detection of bioactive monoclonal antibody concentrations, suitable immobilization strategies of the target were identified. A significant decrease of the limit of detection was achieved by using an adapted affinity method compared to the commonly used amine coupling. Furthermore, the system showed limit of detection in the low ng/mL range similar to control quantifications by enzyme-linked immunosorbent assay. Moreover, the comparison of total to bioactive monoclonal antibody concentrations allows analysis of antibody production efficiency. The development of an alternative quantification system to monitor monoclonal antibody production was accomplished using surface plasmon resonance with the advantage of low analyte volume, shorter assay time, and biosensor reusability by target-layer regeneration. The established method provides the basis for the technical development of a surface plasmon resonance-based system for continuous process monitoring.

2.
Biosensors (Basel) ; 5(1): 27-36, 2015 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-25607476

RESUMEN

We used the interaction between human serum albumin (HSA) and a high-affinity antibody to evaluate binding affinity measurements by the bench-top liSPR system (capitalis technology GmbH). HSA was immobilized directly onto a carboxylated sensor layer, and the mechanism of interaction between the antibody and HSA was investigated. The bivalence and heterogeneity of the antibody caused a complex binding mechanism. Three different interaction models (1:1 binding, heterogeneous analyte, bivalent analyte) were compared, and the bivalent analyte model best fit the curves obtained from the assay. This model describes the interaction of a bivalent analyte with one or two ligands (A + L ↔ LA + L ↔ LLA). The apparent binding affinity for this model measured 37 pM for the first reaction step, and 20 pM for the second step.

3.
FEMS Microbiol Lett ; 351(2): 162-9, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24372686

RESUMEN

The genetically and antigenically diverse group of noroviruses is the major cause of human viral epidemic gastroenteritis worldwide. Virus detection and control are thus crucial topics when aiming at containing and preventing the resulting large and often persisting outbreaks. Aptamers provide a promising alternative to antibodies concerning their ability to bind and thus detect and influence bio-active molecules. These small, single-stranded oligonucleotides are able to bind to a multitude of possible target molecules with high affinity. For a specific target the highest affinity aptamers are found by screening a randomized library. In this work a DNA aptamer capable of binding to the norovirus genotype II.4 capsid protein VP1 was found. The general approach is thereby not limited to norovirus capsid, but could be extended to almost any kind of biologically relevant molecule. The development of the library enrichment was further computationally analyzed in order to describe the enrichment during screening. This is the basis for a later extensive characterization of both target and aptamers that could lead to insights regarding the functional coherence of both partners. An abstract model describing this coherence could be utilized to generate a target-specific library, from which future aptamer screening runs could benefit.


Asunto(s)
Aptámeros de Nucleótidos/aislamiento & purificación , Aptámeros de Nucleótidos/metabolismo , Proteínas de la Cápside/metabolismo , Norovirus/metabolismo , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/genética , Proteínas de la Cápside/química , Proteínas de la Cápside/genética , Biología Computacional , Norovirus/química , Norovirus/genética , Unión Proteica , Técnica SELEX de Producción de Aptámeros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...