1.
Eur Radiol Exp ; 8(1): 51, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38517595

RESUMEN

BACKGROUND: To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS: Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-µm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS: Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS: CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT: Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS: • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.


Asunto(s)
Cateterismo de Swan-Ganz , Arteria Pulmonar , Humanos , Porcinos , Animales , Gasto Cardíaco/fisiología , Arteria Pulmonar/diagnóstico por imagen , Cateterismo de Swan-Ganz/métodos , Perfusión , Tomografía Computarizada por Rayos X
3.
J Clin Med ; 12(8)2023 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-37109088

RESUMEN

Monitoring regional blood flow distribution in the lungs appears to be useful for individually optimizing ventilation therapy. Electrical impedance tomography (EIT) can be used at the bedside for indicator-based regional lung perfusion measurement. Hypertonic saline is widely used as a contrast agent but could be problematic for clinical use due to potential side effects. In five ventilated healthy pigs, we investigated the suitability of five different injectable and clinically approved solutions as contrast agents for EIT-based lung perfusion measurement. Signal extraction success rate, signal strength, and image quality were analyzed after repeated 10 mL bolus injections during temporary apnea. The best results were obtained using NaCl 5.85% and sodium-bicarbonate 8.4% with optimal success rates (100%, each), the highest signal strengths (100 ± 25% and 64 ± 17%), and image qualities (r = 0.98 ± 0.02 and 0.95 ± 0.07). Iomeprol 400 mg/mL (non-ionic iodinated X-ray contrast medium) and Glucose 5% (non-ionic glucose solution) resulted in mostly well usable signals with above average success rates (87% and 89%), acceptable signal strength (32 ± 8% and 16 + 3%), and sufficient image qualities (r = 0.80 ± 0.19 and 0.72 ± 0.21). Isotonic balanced crystalloid solution failed due to a poor success rate (42%), low signal strength (10 ± 4%), and image quality (r = 0.43 ± 0.28). While Iomeprol might enable simultaneous EIT and X-ray measurements, glucose might help to avoid sodium and chloride overload. Further research should address optimal doses to balance reliability and potential side effects.

4.
Diagnostics (Basel) ; 12(4)2022 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-35453825

RESUMEN

Background: Electrical Impedance Tomography (EIT) is a radiation-free technique for image reconstruction. However, as the inverse problem of EIT is non-linear and ill-posed, the reconstruction of sharp conductivity images poses a major problem. With the emergence of artificial neural networks (ANN), their application in EIT has recently gained interest. Methodology: We propose an ANN that can solve the inverse problem without the presence of a reference voltage. At the end of the ANN, we reused the dense layers multiple times, considering that the EIT exhibits rotational symmetries in a circular domain. To avoid bias in training data, the conductivity range used in the simulations was greater than expected in measurements. We also propose a new method that creates new data samples from existing training data. Results: We show that our ANN is more robust with respect to noise compared with the analytical Gauss-Newton approach. The reconstruction results for EIT phantom tank measurements are also clearer, as ringing artefacts are less pronounced. To evaluate the performance of the ANN under real-world conditions, we perform reconstructions on an experimental pig study with computed tomography for comparison. Conclusions: Our proposed ANN can reconstruct EIT images without the need of a reference voltage.

5.
J Clin Med ; 10(13)2021 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-34208890

RESUMEN

RATIONALE: Individualized positive end-expiratory pressure (PEEP) titration might be beneficial in preventing tidal recruitment. To detect tidal recruitment by electrical impedance tomography (EIT), the time disparity between the regional ventilation curves (regional ventilation delay inhomogeneity [RVDI]) can be measured during controlled mechanical ventilation when applying a slow inflation of 12 mL/kg of body weight (BW). However, repeated large slow inflations may result in high end-inspiratory pressure (PEI), which might limit the clinical applicability of this method. We hypothesized that PEEP levels that minimize tidal recruitment can also be derived from EIT-based RVDI through the use of reduced slow inflation volumes. METHODS: Decremental PEEP trials were performed in 15 lung-injured pigs. The PEEP level that minimized tidal recruitment was estimated from EIT-based RVDI measurement during slow inflations of 12, 9, 7.5, or 6 mL/kg BW. We compared RVDI and PEI values resulting from different slow inflation volumes and estimated individualized PEEP levels. RESULTS: RVDI values from slow inflations of 12 and 9 mL/kg BW showed excellent linear correlation (R2 = 0.87, p < 0.001). Correlations decreased for RVDI values from inflations of 7.5 (R2 = 0.68, p < 0.001) and 6 (R2 = 0.42, p < 0.001) mL/kg BW. Individualized PEEP levels estimated from 12 and 9 mL/kg BW were comparable (bias -0.3 cm H2O ± 1.2 cm H2O). Bias and scatter increased with further reduction in slow inflation volumes (for 7.5 mL/kg BW, bias 0 ± 3.2 cm H2O; for 6 mL/kg BW, bias 1.2 ± 4.0 cm H2O). PEI resulting from 9 mL/kg BW inflations were comparable with PEI during regular tidal volumes. CONCLUSIONS: PEEP titration to minimize tidal recruitment can be individualized according to EIT-based measurement of the time disparity of regional ventilation courses during slow inflations with low inflation volumes. This sufficiently decreases PEI and may reduce potential clinical risks.

6.
Physiol Meas ; 42(8)2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34167091

RESUMEN

Objective. Electrical impedance tomography (EIT) for lung perfusion imaging is attracting considerable interest in intensive care, as it might open up entirely new ways to adjust ventilation therapy. A promising technique is bolus injection of a conductive indicator to the central venous catheter, which yields the indicator-based signal (IBS). Lung perfusion images are then typically obtained from the IBS using the maximum slope technique. However, the low spatial resolution of EIT results in a partial volume effect (PVE), which requires further processing to avoid regional bias.Approach. In this work, we repose the extraction of lung perfusion images from the IBS as a source separation problem to account for the PVE. We then propose a model-based algorithm, called gamma decomposition (GD), to derive an efficient solution. The GD algorithm uses a signal model to transform the IBS into a parameter space where the source signals of heart and lung are separable by clustering in space and time. Subsequently, it reconstructs lung model signals from which lung perfusion images are unambiguously extracted.Main results. We evaluate the GD algorithm on EIT data of a prospective animal trial with eight pigs. The results show that it enables lung perfusion imaging using EIT at different stages of regional impairment. Furthermore, parameters of the source signals seem to represent physiological properties of the cardio-pulmonary system.Significance. This work represents an important advance in IBS processing that will likely reduce bias of EIT perfusion images and thus eventually enable imaging of regional ventilation/perfusion (V/Q) ratio.


Asunto(s)
Pulmón , Tomografía , Algoritmos , Animales , Impedancia Eléctrica , Pulmón/diagnóstico por imagen , Imagen de Perfusión , Estudios Prospectivos , Porcinos
7.
J Clin Med ; 8(8)2019 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-31394721

RESUMEN

Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).

8.
J Clin Med ; 8(8)2019 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-31382559

RESUMEN

Avoiding tidal recruitment and collapse during mechanical ventilation should reduce the risk of lung injury. Electrical impedance tomography (EIT) enables detection of tidal recruitment by measuring regional ventilation delay inhomogeneity (RVDI) during a slow inflation breath with a tidal volume (VT) of 12 mL/kg body weight (BW). Clinical applicability might be limited by such high VTs resulting in high end-inspiratory pressures (PEI) during positive end-expiratory pressure (PEEP) titration. We hypothesized that RVDI can be obtained with acceptable accuracy from reduced slow inflation VTs. In seven ventilated pigs with experimental lung injury, tidal recruitment was quantified by computed tomography at PEEP levels changed stepwise between 0 and 25 cmH2O. RVDI was measured by EIT during slow inflation VTs of 12, 9, 7.5, and 6 mL/kg BW. Linear correlation of tidal recruitment and RVDI was excellent for VTs of 12 (R2 = 0.83, p < 0.001) and 9 mL/kg BW (R2 = 0.83, p < 0.001) but decreased for VTs of 7.5 (R2 = 0.76, p < 0.001) and 6 mL/kg BW (R2 = 0.71, p < 0.001). With any reduction in slow inflation VT, PEI decreased at all PEEP levels. Receiver-Operator-Characteristic curve analyses revealed that RVDI-thresholds to predict distinct amounts of tidal recruitment differ when obtained from different slow inflation VTs. In conclusion, tidal recruitment can sufficiently be monitored by EIT-based RVDI-calculation with a slow inflation of 9 mL/kg BW.

9.
Physiol Meas ; 39(6): 065004, 2018 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-29794336

RESUMEN

OBJECTIVE: Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation ([Formula: see text]) in intensive care patients at bedside. However, for improved guidance of ventilation therapy it would be beneficial to obtain regional ventilation-to-perfusion ratio ([Formula: see text]) by EIT. APPROACH: In order to further explore the feasibility, we first evaluate a model-based approach, based on semi-negative matrix factorization and a gamma-variate model, to extract regional lung perfusion ([Formula: see text]) from EIT measurements. Subsequently, a combined validation of both [Formula: see text] and [Formula: see text] measured by EIT against single-photon emission computed tomography (SPECT) is performed on data acquired as part of a porcine animal trial. Four pigs were ventilated at two different levels of positive end-expiratory pressure (PEEP 0 and 15 cm H2O, respectively) in randomized order. Repeated injections of an EIT contrast agent (NaCl 10%) and simultaneous SPECT measurements of [Formula: see text] (81mKr gas) and [Formula: see text] (99mTc-labeled albumin) were performed. MAIN RESULTS: Both [Formula: see text] and [Formula: see text] from EIT and SPECT were compared by correlation analysis. Very strong (r 2 = 0.94 to 0.95) correlations were found for [Formula: see text] and [Formula: see text] in the dorsal-ventral direction at both PEEP levels. Moderate (r 2 = 0.36 to 0.46) and moderate to strong (r 2 = 0.61 to 0.82) correlations resulted for [Formula: see text] and [Formula: see text] in the right-left direction, respectively. SIGNIFICANCE: The results of combined validation indicate that monitoring of [Formula: see text] and [Formula: see text] by EIT is possible. However, care should be taken when trying to quantify [Formula: see text] by EIT, as imaging artefacts and model bias may void necessary spatial matching.


Asunto(s)
Ventilación Pulmonar , Flujo Sanguíneo Regional , Tomografía Computarizada de Emisión de Fotón Único , Animales , Impedancia Eléctrica , Procesamiento de Imagen Asistido por Computador , Porcinos
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 3596-3599, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29060676

RESUMEN

Electrical impedance tomography (EIT) is a non-invasive imaging technique, that can be used to monitor regional lung ventilation (V̇) in intensive care units (ICU) at bedside. This work introduces a method to extract regional lung perfusion (Q̇) from EIT image streams in order to quantify regional gas exchange in the lungs. EIT data from a single porcine animal trial, recorded during injection of a contrast agent (NaCl 10%) into a central venous catheter (CVC), are used for evaluation. Using semi-negative matrix factorization (Semi-NMF) a set of source signals is extracted from the data. A subsequent non-linear fit of a gamma-variate model to the source signals results in model signals, describing contrast agent flow through the cardio-pulmonary system. A linear fit of the model signals to the EIT image stream then yields functional images ofQ̇. Additionally, a pulmonary transit function (PTF) and parameters, such as mean transit time (MTT), time to peak (TTP) and area under curve (AUC) are derived. In result, EIT was used to track changes of regional lung ventilation to perfusion ratio (V̇/Q̇) during changes of positive end-expiratory pressure (PEEP). Furthermore, correlations of MTT and AUC with cardiac output (CO) indicate that CO measurement by EIT might be possible.


Asunto(s)
Impedancia Eléctrica , Animales , Pulmón , Respiración con Presión Positiva , Porcinos , Tomografía
SELECCIÓN DE REFERENCIAS