Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Radiol ; 163: 110832, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37059005

RESUMEN

PURPOSE: Accumulating evidence from epidemiological studies that pediatric computed tomography (CT) examinations can be associated with a small but non-zero excess risk for developing leukemia or brain tumor highlights the need to optimize doses of pediatric CT procedures. Mandatory dose reference levels (DRL) can support reduction of collective dose from CT imaging. Regular surveys of applied dose-related parameters are instrumental to decide when technological advances and optimized protocol design allow lower doses without sacrificing image quality. Our aim was to collect dosimetric data to support adapting current DRL to changing clinical practice. METHOD: Dosimetric data and technical scan parameters from common pediatric CT examinations were retrospectively collected directly from Picture Archiving and Communication Systems (PACS), Dose Management Systems (DMS), and Radiological Information Systems (RIS). RESULTS: We collected data from 17 institutions on 7746 CT series from the years 2016 to 2018 from examinations of the head, thorax, abdomen, cervical spine, temporal bone, paranasal sinuses and knee in patients below 18 years of age. Most of the age-stratified parameter distributions were lower than distributions from previously-analyzed data from before 2010. Most of the third quartiles were lower than German DRL at the time of the survey. CONCLUSIONS: Directly interfacing PACS, DMS, and RIS installations allows large-scale data collection but relies on high data-quality at the documentation stage. Data should be validated by expert knowledge or guided questionnaires. Observed clinical practice in pediatric CT imaging suggests lowering some DRL in Germany is reasonable.


Asunto(s)
Tomografía Computarizada por Rayos X , Niño , Humanos , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Encuestas y Cuestionarios , Alemania/epidemiología , Valores de Referencia
2.
Radiat Res ; 196(1): 74-99, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33914893

RESUMEN

Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exposure characteristics were reconstructed for patients within specific age groups who received scans of the same body region, based on categories of machines with common technology used over the time period in each of the 276 participating hospitals. A carefully designed method for assessing uncertainty combined with the National Cancer Institute Dosimetry System for CT (NCICT, a CT organ dose calculator), was employed to estimate absorbed dose to individual organs for each CT scan received. The two-dimensional Monte Carlo sampling method, which maintains a separation of shared and unshared error, allowed us to characterize uncertainty both on individual doses as well as for the entire cohort dose distribution. Provided here are summaries of estimated doses from CT imaging per scan and per examination, as well as the overall distribution of estimated doses in the cohort. Doses are provided for five selected tissues (active bone marrow, brain, eye lens, thyroid and female breasts), by body region (i.e., head, chest, abdomen/pelvis), patient age, and time period (1977-1990, 1991-2000, 2001-2014). Relatively high doses were received by the brain from head CTs in the early 1990s, with individual mean doses (mean of 200 simulated values) of up to 66 mGy per scan. Optimization strategies implemented since the late 1990s have resulted in an overall decrease in doses over time, especially at young ages. In chest CTs, active bone marrow doses dropped from over 15 mGy prior to 1991 to approximately 5 mGy per scan after 2001. Our findings illustrate patterns of age-specific doses and their temporal changes, and provide suitable dose estimates for radiation-induced risk estimation in epidemiological studies.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Adolescente , Niño , Preescolar , Estudios de Cohortes , Europa (Continente)/epidemiología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Fantasmas de Imagen
3.
J Radiol Prot ; 40(4)2020 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-32668420

RESUMEN

The HARMONIC project (Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Paediatrics) is a European study aiming to improve our understanding of the long-term health risks from radiation exposures in childhood and early adulthood. Here, we present the study design for the cardiac fluoroscopy component of HARMONIC. A pooled cohort of approximately 100 000 patients who underwent cardiac fluoroscopy procedures in Belgium, France, Germany, Italy, Norway, Spain or the UK, while aged under 22 years, will be established from hospital records and/or insurance claims data. Doses to individual organs will be estimated from dose indicators recorded at the time of examination, using a lookup-table-based dosimetry system produced using Monte Carlo radiation transport simulations and anatomically realistic computational phantom models. Information on beam geometry and x-ray energy spectra will be obtained from a representative sample of radiation dose structured reports. Uncertainties in dose estimates will be modelled using 2D Monte Carlo methods. The cohort will be followed up using national registries and insurance records to determine vital status and cancer incidence. Information on organ transplantation (a major risk factor for cancer development in this patient group) and/or other conditions predisposing to cancer will be obtained from national or local registries and health insurance data, depending on country. The relationship between estimated radiation dose and cancer risk will be investigated using regression modelling. Results will improve information for patients and parents and aid clinicians in managing and implementing changes to reduce radiation risks without compromising medical benefits.


Asunto(s)
Neoplasias , Radiometría , Adulto , Anciano , Niño , Fluoroscopía/efectos adversos , Humanos , Método de Montecarlo , Neoplasias/radioterapia , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos , Factores de Riesgo
4.
Int J Environ Res Public Health ; 10(2): 717-28, 2013 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-23429160

RESUMEN

The increasing worldwide use of paediatric computed tomography (CT) has led to increasing concerns regarding the subsequent effects of exposure to radiation. In response to this concern, the international EPI-CT project was developed to study the risk of cancer in a large multi-country cohort. In radiation epidemiology, accurate estimates of organ-specific doses are essential. In EPI-CT, data collection is split into two time periods--before and after introduction of the Picture Archiving Communication System (PACS) introduced in the 1990s. Prior to PACS, only sparse information about scanner settings is available from radiology departments. Hence, a multi-level approach was developed to retrieve information from a questionnaire, surveys, scientific publications, and expert interviews. For the years after PACS was introduced, scanner settings will be extracted from Digital Imaging and Communications in Medicine (DICOM) headers, a protocol for storing medical imaging data. Radiation fields and X-ray interactions within the body will be simulated using phantoms of various ages and Monte-Carlo-based radiation transport calculations. Individual organ doses will be estimated for each child using an accepted calculation strategy, scanner settings, and the radiation transport calculations. Comprehensive analyses of missing and uncertain dosimetry data will be conducted to provide uncertainty distributions of doses.


Asunto(s)
Neoplasias/epidemiología , Dosis de Radiación , Tomografía Computarizada por Rayos X , Adolescente , Niño , Preescolar , Europa (Continente)/epidemiología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Método de Montecarlo , Encuestas y Cuestionarios , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...