Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Brain Sci ; 14(7)2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39061454

RESUMEN

Speech-language therapy (SLT) is the most effective technique to improve language performance in persons with aphasia. However, residual language impairments remain even after intensive SLT. Recent studies suggest that combining transcranial direct current stimulation (tDCS) with SLT may improve language performance in persons with aphasia. However, our understanding of how tDCS and SLT impact brain and behavioral relation in aphasia is poorly understood. We investigated the impact of tDCS and SLT on a behavioral measure of scripted conversation and on functional connectivity assessed with multiple methods, both resting-state functional magnetic resonance imaging (rs-fMRI) and resting-state electroencephalography (rs-EEG). An individual with aphasia received 15 sessions of 20-min cathodal tDCS to the right angular gyrus concurrent with 40 min of SLT. Performance during scripted conversation was measured three times at baseline, twice immediately post-treatment, and at 4- and 8-weeks post-treatment. rs-fMRI was measured pre-and post-3-weeks of treatment. rs-EEG was measured on treatment days 1, 5, 10, and 15. Results show that both communication performance and left hemisphere functional connectivity may improve after concurrent tDCS and SLT. Results are in line with aphasia models of language recovery that posit a beneficial role of left hemisphere perilesional areas in language recovery.

2.
Brain Topogr ; 37(5): 659-683, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38598019

RESUMEN

Electroencephalogram (EEG) recorded as response to transcranial magnetic stimulation (TMS) can be highly informative of cortical reactivity and connectivity. Reliable EEG interpretation requires artifact removal as the TMS-evoked EEG can contain high-amplitude artifacts. Several methods have been proposed to uncover clean neuronal EEG responses. In practice, determining which method to select for different types of artifacts is often difficult. Here, we used a unified data cleaning framework based on beamforming to improve the algorithm selection and adaptation to the recorded signals. Beamforming properties are well understood, so they can be used to yield customized methods for EEG cleaning based on prior knowledge of the artifacts and the data. The beamforming implementations also cover, but are not limited to, the popular TMS-EEG cleaning methods: independent component analysis (ICA), signal-space projection (SSP), signal-space-projection-source-informed-reconstruction method (SSP-SIR), the source-estimate-utilizing noise-discarding algorithm (SOUND), data-driven Wiener filter (DDWiener), and the multiple-source approach. In addition to these established methods, beamforming provides a flexible way to derive novel artifact suppression algorithms by considering the properties of the recorded data. With simulated and measured TMS-EEG data, we show how to adapt the beamforming-based cleaning to different data and artifact types, namely TMS-evoked muscle artifacts, ocular artifacts, TMS-related peripheral responses, and channel noise. Importantly, beamforming implementations are fast to execute: We demonstrate how the SOUND algorithm becomes orders of magnitudes faster via beamforming. Overall, the beamforming-based spatial filtering framework can greatly enhance the selection, adaptability, and speed of EEG artifact removal.


Asunto(s)
Algoritmos , Artefactos , Electroencefalografía , Estimulación Magnética Transcraneal , Humanos , Electroencefalografía/métodos , Estimulación Magnética Transcraneal/métodos , Procesamiento de Señales Asistido por Computador , Encéfalo/fisiología , Adulto , Masculino , Femenino
4.
Clin Neurophysiol ; 154: 169-193, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37634335

RESUMEN

OBJECTIVE: Cortico-cortical paired associative stimulation (ccPAS) is a form of dual-site transcranial magnetic stimulation (TMS) entailing a series of single-TMS pulses paired at specific interstimulus intervals (ISI) delivered to distant cortical areas. The goal of this article is to systematically review its efficacy in inducing plasticity in humans focusing on stimulation parameters and hypotheses of underlying neurophysiology. METHODS: A systematic review of the literature from 2009-2023 was undertaken to identify all articles utilizing ccPAS to study brain plasticity and connectivity. Six electronic databases were searched and included. RESULTS: 32 studies were identified. The studies targeted connections within the same hemisphere or between hemispheres. 28 ccPAS studies were in healthy participants, 1 study in schizophrenia, and 1 in Alzheimer's disease (AD) patients. 2 additional studies used cortico-cortical repetitive paired associative stimulation (cc-rPAS) in generalized anxiety disorder (GAD) patients. Outcome measures include electromyography (EMG), behavioral measures, electroencephalography (EEG), and functional magnetic resonance imaging (fMRI). ccPAS seems to be able to modulate brain connectivity depending on the ISI. CONCLUSIONS: ccPAS can be used to modulate corticospinal excitability, brain activity, and behavior. Although the stimulation parameters used across studies reviewed in this paper are varied, ccPAS is a promising approach for basic research and potential clinical applications. SIGNIFICANCE: Recent advances in neuroscience have caused a shift of interest from the study of single areas to a more complex approach focusing on networks of areas that orchestrate brain activity. Consequently, the TMS community is also witnessing a change, with a growing interest in targeting multiple brain areas rather than a single locus, as evidenced by an increasing number of papers using ccPAS. In light of this new enthusiasm for brain connectivity, this review summarizes existing literature and stimulation parameters that have proven effective in changing electrophysiological, behavioral, or neuroimaging-derived measures.


Asunto(s)
Corteza Motora , Humanos , Potenciales Evocados Motores/fisiología , Estimulación Magnética Transcraneal/métodos , Encéfalo/diagnóstico por imagen , Plasticidad Neuronal/fisiología
5.
Brain Stimul ; 16(2): 567-593, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36828303

RESUMEN

Transcranial magnetic stimulation (TMS) evokes neuronal activity in the targeted cortex and connected brain regions. The evoked brain response can be measured with electroencephalography (EEG). TMS combined with simultaneous EEG (TMS-EEG) is widely used for studying cortical reactivity and connectivity at high spatiotemporal resolution. Methodologically, the combination of TMS with EEG is challenging, and there are many open questions in the field. Different TMS-EEG equipment and approaches for data collection and analysis are used. The lack of standardization may affect reproducibility and limit the comparability of results produced in different research laboratories. In addition, there is controversy about the extent to which auditory and somatosensory inputs contribute to transcranially evoked EEG. This review provides a guide for researchers who wish to use TMS-EEG to study the reactivity of the human cortex. A worldwide panel of experts working on TMS-EEG covered all aspects that should be considered in TMS-EEG experiments, providing methodological recommendations (when possible) for effective TMS-EEG recordings and analysis. The panel identified and discussed the challenges of the technique, particularly regarding recording procedures, artifact correction, analysis, and interpretation of the transcranial evoked potentials (TEPs). Therefore, this work offers an extensive overview of TMS-EEG methodology and thus may promote standardization of experimental and computational procedures across groups.


Asunto(s)
Electroencefalografía , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Reproducibilidad de los Resultados , Electroencefalografía/métodos , Potenciales Evocados/fisiología , Recolección de Datos
6.
Neuromodulation ; 26(4): 745-754, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36404214

RESUMEN

OBJECTIVE: The ability to selectively up- or downregulate interregional brain connectivity would be useful for research and clinical purposes. Toward this aim, cortico-cortical paired associative stimulation (ccPAS) protocols have been developed in which two areas are repeatedly stimulated with a millisecond-level asynchrony. However, ccPAS results in humans using bifocal transcranial magnetic stimulation (TMS) have been variable, and the mechanisms remain unproven. In this study, our goal was to test whether ccPAS mechanism is spike-timing-dependent plasticity (STDP). MATERIALS AND METHODS: Eleven healthy participants received ccPAS to the left primary motor cortex (M1) → right M1 with three different asynchronies (5 milliseconds shorter, equal to, or 5 milliseconds longer than the 9-millisecond transcallosal conduction delay) in separate sessions. To observe the neurophysiological effects, single-pulse TMS was delivered to the left M1 before and after ccPAS while cortico-cortical evoked responses were extracted from the contralateral M1 using source-resolved electroencephalography. RESULTS: Consistent with STDP mechanisms, the effects on synaptic strengths flipped depending on the asynchrony. Further implicating STDP, control experiments suggested that the effects were unidirectional and selective to the targeted connection. CONCLUSION: The results support the idea that ccPAS induces STDP and may selectively up- or downregulate effective connectivity between targeted regions in the human brain.


Asunto(s)
Corteza Motora , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Corteza Motora/fisiología , Electroencefalografía , Motivación , Potenciales Evocados Motores/fisiología , Plasticidad Neuronal/fisiología
8.
J Neurosci Methods ; 376: 109591, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35421514

RESUMEN

Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) is a technique for studying cortical excitability and connectivity in health and disease, allowing basic research and potential clinical applications. A major methodological issue, severely limiting the applicability of TMS-EEG, relates to the contamination of EEG signals by artifacts of biologic or non-biologic origin. To solve this problem, several methods, based on independent component analysis (ICA), principal component analysis (PCA), signal space projection (SSP), and other approaches, have been developed over the last decade. This article is divided into two parts. In the first part, we review the theoretical background of the currently available TMS-EEG artifact removal methods. In the second part, we formally introduce the mathematics underpinnings of the cleaning methods. We classify them into spatial and temporal filters based on their properties. Since the most frequently used TMS-EEG cleaning approach are spatial filter methods, we focus on them and introduce beamforming as a unified framework of the most popular spatial filtering techniques. This unifying approach enables the comparative assessment of these methods by highlighting their differences in terms of assumptions, challenges, and applicability for different types of artifacts and data. The different properties and challenges of the methods discussed are illustrated with both simulated and recorded data. This article targets non-mathematical and mathematical audiences. Accordingly, those readers interested in essential background information on these methods can focus on Section 2. Whereas theory-oriented readers may find Section 3 helpful for making informed decisions between existing methods and developing the methodology further.


Asunto(s)
Artefactos , Estimulación Magnética Transcraneal , Electroencefalografía/métodos , Análisis de Componente Principal , Estimulación Magnética Transcraneal/métodos
9.
Clin Neurophysiol ; 134: 129-136, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34776356

RESUMEN

OBJECTIVE: The impact of transcranial magnetic stimulation (TMS) has been shown to depend on the initial brain state of the stimulated cortical region. This observation has led to the development of paradigms that aim to enhance the specificity of TMS effects by using visual/luminance adaptation to modulate brain state prior to the application of TMS. However, the neural basis of interactions between TMS and adaptation is unknown. Here, we examined these interactions by using electroencephalography (EEG) to measure the impact of TMS over the visual cortex after luminance adaptation. METHODS: Single-pulses of neuronavigated TMS (nTMS) were applied at two different intensities over the left visual cortex after adaptation to either high or low luminance. We then analyzed the effects of adaptation on the global and local cortical excitability. RESULTS: The analysis revealed a significant interaction between the TMS-evoked responses and the adaptation condition. In particular, when nTMS was applied with high intensity, the evoked responses were larger after adaptation to high than low luminance. CONCLUSION: This result provides the first neural evidence on the interaction between TMS with visual adaptation. SIGNIFICANCE: TMS can activate neurons differentially as a function of their adaptation state.


Asunto(s)
Adaptación Fisiológica/fisiología , Potenciales Evocados/fisiología , Corteza Visual/fisiología , Adulto , Electroencefalografía , Femenino , Humanos , Masculino , Estimulación Magnética Transcraneal
10.
J Neuroeng Rehabil ; 18(1): 98, 2021 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-34112208

RESUMEN

Studying the human brain during interpersonal interaction allows us to answer many questions related to motor control and cognition. For instance, what happens in the brain when two people walking side by side begin to change their gait and match cadences? Adapted from the neuroimaging techniques used in single-brain measurements, hyperscanning (HS) is a technique used to measure brain activity from two or more individuals simultaneously. Thus far, HS has primarily focused on healthy participants during social interactions in order to characterize inter-brain dynamics. Here, we advocate for expanding the use of this electroencephalography hyperscanning (EEG-HS) technique to rehabilitation paradigms in individuals with neurological diagnoses, namely stroke, spinal cord injury (SCI), Parkinson's disease (PD), and traumatic brain injury (TBI). We claim that EEG-HS in patient populations with impaired motor function is particularly relevant and could provide additional insight on neural dynamics, optimizing rehabilitation strategies for each individual patient. In addition, we discuss future technologies related to EEG-HS that could be developed for use in the clinic as well as technical limitations to be considered in these proposed settings.


Asunto(s)
Electroencefalografía , Neuroimagen , Encéfalo/diagnóstico por imagen , Cognición , Humanos , Relaciones Interpersonales
11.
J Neural Eng ; 18(5)2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33721852

RESUMEN

Objectives. This paper aims to investigate the feasibility and the validity of applying deep convolutional neural networks (CNN) to identify motor unit (MU) spike trains and estimate the neural drive to muscles from high-density electromyography (HD-EMG) signals in real time. Two distinct deep CNNs are compared with the convolution kernel compensation (CKC) algorithm using simulated and experimentally recorded signals. The effects of window size and step size of the input HD-EMG signals are also investigated.Approach. The MU spike trains were first identified with the CKC algorithm. The HD-EMG signals and spike trains were used to train the deep CNN. Then, the deep CNN decomposed the HD-EMG signals into MU discharge times in real time. Two CNN approaches are compared with the CKC: (a) multiple single-output deep CNN (SO-DCNN) with one MU decomposed per network, and (b) one multiple-output deep CNN (MO-DCNN) to decompose all MUs (up to 23) with one network.Main results. The MO-DCNN outperformed the SO-DCNN in terms of training time (3.2-21.4 s epoch-1vs 6.5-47.8 s epoch-1, respectively) and prediction time (0.04 vs 0.27 s sample-1, respectively). The optimal window size and step size for MO-DCNN were 120 and 20 data points, respectively. It results in sensitivity of 98% and 85% with simulated and experimentally recorded HD-EMG signals, respectively. There is a high cross-correlation coefficient between the neural drive estimated with CKC and that estimated with MO-DCNN (range ofr-value across conditions: 0.88-0.95).Significance. We demonstrate the feasibility and the validity of using deep CNN to accurately identify MU activity from HD-EMG with a latency lower than 80 ms, which falls within the lower bound of the human electromechanical delay. This method opens many opportunities for using the neural drive to interface humans with assistive devices.


Asunto(s)
Algoritmos , Redes Neurales de la Computación , Electromiografía/métodos , Humanos
12.
J Neuroeng Rehabil ; 18(1): 33, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-33588841

RESUMEN

Interventions to reduce tremor in essential tremor (ET) and Parkinson's disease (PD) clinical populations often utilize pharmacological or surgical therapies. However, there can be significant side effects, decline in effectiveness over time, or clinical contraindications for these interventions. Therefore, alternative approaches must be considered and developed. Some non-pharmacological strategies include assistive devices, orthoses and mechanical loading of the tremorgenic limb, while others propose peripheral electrical stimulation. Specifically, peripheral electrical stimulation encompasses strategies that activate motor and sensory pathways to evoke muscle contractions and impact sensorimotor function. Numerous studies report the efficacy of peripheral electrical stimulation to alter tremor generation, thereby opening new perspectives for both short- and long-term tremor reduction. Therefore, it is timely to explore this promising modality in a comprehensive review. In this review, we analyzed 27 studies that reported the use of peripheral electrical stimulation to reduce tremor and discuss various considerations regarding peripheral electrical stimulation: the stimulation strategies and parameters, electrodes, experimental designs, results, and mechanisms hypothesized to reduce tremor. From our review, we identified a high degree of disparity across studies with regard to stimulation patterns, experimental designs and methods of assessing tremor. Having standardized experimental methodology is a critical step in the field and is needed in order to accurately compare results across studies. With this review, we explore peripheral electrical stimulation as an intervention for tremor reduction, identify the limitations and benefits of the current state-of-the-art studies, and provide ideas to guide the development of novel approaches based on the neural circuitries and mechanical properties implied in tremor generation.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Temblor/terapia , Humanos , Masculino , Temblor/fisiopatología
13.
Phys Med Rehabil Clin N Am ; 30(2): 319-335, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30954150

RESUMEN

It is likely that transcranial magnetic brain stimulation will be used for the clinical treatment of stroke and stroke-related impairments in the future. The anatomic target and stimulation parameters will likely vary for any clinical focus, be it weakness, pain, or cognitive or communicative dysfunction. Biomarkers may also be useful for identifying patients who will respond best, with a goal to enhance clinical decision making. Combination with drugs or specific types of therapeutic exercise may be necessary to achieve maximal response.


Asunto(s)
Rehabilitación de Accidente Cerebrovascular , Estimulación Magnética Transcraneal , Humanos , Accidente Cerebrovascular/fisiopatología , Rehabilitación de Accidente Cerebrovascular/métodos , Estimulación Magnética Transcraneal/métodos
14.
Neuroimage ; 147: 934-951, 2017 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-27771347

RESUMEN

The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS-EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS-EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS-EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS-EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS-EEG research.


Asunto(s)
Artefactos , Encéfalo/fisiología , Electroencefalografía/métodos , Potenciales Evocados/fisiología , Estimulación Magnética Transcraneal/métodos , Electroencefalografía/normas , Humanos , Estimulación Magnética Transcraneal/normas
15.
Neuroimage ; 142: 645-655, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27431760

RESUMEN

OBJECTIVES: Auditory and visual deviant stimuli evoke mismatch negativity (MMN) responses, which can be recorded with electroencephalography (EEG) and magnetoencephalography (MEG). However, little is known about the role of neuronal oscillations in encoding of rare stimuli. We aimed at verifying the existence of a mechanism for the detection of deviant visual stimuli on the basis of oscillatory responses, so-called visual mismatch oscillatory response (vMOR). METHODS: Peripheral visual stimuli in an oddball paradigm, standard vs. deviant (7:1), were presented to twenty healthy subjects. The oscillatory responses to an infrequent change in the direction of moving peripheral stimuli were recorded with a 60-channel EEG system. In order to enhance the detection of oscillatory responses, we used the common spatial pattern (CSP) algorithm, designed for the optimal extraction of changes in the amplitude of oscillations. RESULTS: Both standard and deviant visual stimuli produced Event-Related Desynchronization (ERD) and Synchronization (ERS) primarily in the occipito-parietal cortical areas. ERD and ERS had overlapping time-courses and peaked at about 500-730 ms. These oscillatory responses, however, were significantly stronger for the deviant than for the standard stimuli. A difference between the oscillatory responses to deviant and standard stimuli thus reflects the presence of vMOR. CONCLUSIONS: The present study shows that the detection of visual deviant stimuli can be reflected in both synchronization and desynchronization of neuronal oscillations. This broadens our knowledge about the brain mechanisms encoding deviant sensory stimuli.


Asunto(s)
Sincronización de Fase en Electroencefalografía/fisiología , Potenciales Evocados/fisiología , Lóbulo Occipital/fisiología , Lóbulo Parietal/fisiología , Procesamiento de Señales Asistido por Computador , Percepción Visual/fisiología , Adulto , Femenino , Humanos , Masculino
17.
Artículo en Inglés | MEDLINE | ID: mdl-26736242

RESUMEN

The artifact problem in TMS-evoked EEG is analyzed in an attempt to clarify the nature of the problem and to present solutions. The best way to deal with artifacts is to avoid them; the removal or suppression of the unavoidable artifacts should be based on accurate information about their characteristics and the properties of the signal of interest.


Asunto(s)
Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Estimulación Magnética Transcraneal/métodos , Artefactos , Humanos
18.
Front Hum Neurosci ; 8: 660, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25228868

RESUMEN

Transcranial magnetic stimulation (TMS) has been used to induce speech disturbances and to affect speech performance during different naming tasks. Lately, repetitive navigated TMS (nTMS) has been used for non-invasive mapping of cortical speech-related areas. Different naming tasks may give different information that can be useful for presurgical evaluation. We studied the sensitivity of object and action naming tasks to nTMS and compared the distributions of cortical sites where nTMS produced naming errors. Eight healthy subjects named pictures of objects and actions during repetitive nTMS delivered to semi-random left-hemispheric sites. Subject-validated image stacks were obtained in the baseline naming of all pictures before nTMS. Thereafter, nTMS pulse trains were delivered while the subjects were naming the images of objects or actions. The sessions were video-recorded for offline analysis. Naming during nTMS was compared with the baseline performance. The nTMS-induced naming errors were categorized by error type and location. nTMS produced no-response errors, phonological paraphasias, and semantic paraphasias. In seven out of eight subjects, nTMS produced more errors during object than action naming. Both intrasubject and intersubject analysis showed that object naming was significantly more sensitive to nTMS. When the number of errors was compared according to a given area, nTMS to postcentral gyrus induced more errors during object than action naming. Object naming is apparently more easily disrupted by TMS than action naming. Different stimulus types can be useful for locating different aspects of speech functions. This provides new possibilities in both basic and clinical research of cortical speech representations.

19.
Neuroimage ; 101: 425-39, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25067813

RESUMEN

INTRODUCTION: The combination of transcranial magnetic stimulation and electroencephalography (TMS-EEG) is emerging as a powerful tool for causally investigating cortical mechanisms and networks. However, various artefacts contaminate TMS-EEG recordings, particularly over regions such as the dorsolateral prefrontal cortex (DLPFC). The aim of this study was to substantiate removal of artefacts from TMS-EEG recordings following stimulation of the DLPFC and motor cortex using independent component analysis (ICA). METHODS: 36 healthy volunteers (30.8 ± 9 years, 9 female) received 75 single TMS pulses to the left DLPFC or left motor cortex while EEG was recorded from 57 electrodes. A subset of 9 volunteers also received 50 sham pulses. The large TMS artefact and early muscle activity (-2 to ~15 ms) were removed using interpolation and the remaining EEG signal was processed in two separate ICA runs using the FastICA algorithm. Five sub-types of TMS-related artefacts were manually identified: remaining muscle artefacts, decay artefacts, blink artefacts, auditory-evoked potentials and other noise-related artefacts. The cause of proposed blink and auditory-evoked potentials was assessed by concatenating known artefacts (i.e. voluntary blinks or auditory-evoked potentials resulting from sham TMS) to the TMS trials before ICA and evaluating grouping of resultant independent components (ICs). Finally, we assessed the effect of removing specific artefact types on TMS-evoked potentials (TEPs) and TMS-evoked oscillations. RESULTS: Over DLPFC, ICs from proposed muscle and decay artefacts correlated with TMS-evoked muscle activity size, whereas proposed TMS-evoked blink ICs combined with voluntary blinks and auditory ICs with auditory-evoked potentials from sham TMS. Individual artefact sub-types characteristically distorted each measure of DLPFC function across the scalp. When free of artefact, TEPs and TMS-evoked oscillations could be measured following DLPFC stimulation. Importantly, characteristic TEPs following motor cortex stimulation (N15, P30, N45, P60, N100) could be recovered from artefactual data, corroborating the reliability of ICA-based artefact correction. CONCLUSIONS: Various different artefacts contaminate TMS-EEG recordings over the DLPFC and motor cortex. However, these artefacts can be removed with apparent minimal impact on neural activity using ICA, allowing the study of TMS-evoked cortical network properties.


Asunto(s)
Artefactos , Electroencefalografía/normas , Potenciales Evocados/fisiología , Corteza Motora/fisiología , Corteza Prefrontal/fisiología , Estimulación Magnética Transcraneal/normas , Adulto , Interpretación Estadística de Datos , Electroencefalografía/métodos , Femenino , Humanos , Masculino , Estimulación Magnética Transcraneal/métodos , Adulto Joven
20.
J Neurosci Methods ; 209(1): 144-57, 2012 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-22687937

RESUMEN

Transcranial magnetic stimulation (TMS) combined with electroencephalography (EEG) is a powerful tool for studying cortical excitability and connectivity. To enhance the EEG interpretation, independent component analysis (ICA) has been used to separate the data into independent components (ICs). However, TMS can evoke large artifacts in EEG, which may greatly distort the ICA separation. The removal of such artifactual EEG from the data is a difficult task. In this paper we study how badly the large artifacts distort the ICA separation, and whether the distortions could be avoided without removing the artifacts. We first show that, in the ICA separation, the time courses of the ICs are not affected by the large artifacts, but their topographies could be greatly distorted. Next, we show how this distortion can be circumvented. We introduce a novel technique of suppression, by which the EEG data are modified so that the ICA separation of the suppressed data becomes reliable. The suppression, instead of removing the artifactual EEG, rescales all the data to about the same magnitude as the neural EEG. For the suppressed data, ICA returns the original time courses, but instead of the original topographies, it returns modified ones, which can be used, e.g., for the source localization. We present three suppression methods based on principal component analysis, wavelet analysis, and whitening of the data matrix, respectively. We test the methods with numerical simulations. The results show that the suppression improves the source localization.


Asunto(s)
Artefactos , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Estimulación Magnética Transcraneal/métodos , Algoritmos , Mapeo Encefálico/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA