Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Front Physiol ; 12: 687046, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34248674

RESUMEN

Mounting evidence from animal models of inflammatory and neuropathic pain suggests that inflammation regulates the resolution of pain by producing specialized pro-resolving mediators (SPMs), such as resolvin D1 (RvD1). However, it remains unclear how SPMs are induced in the central nervous system and whether these mechanisms can be reconciled with outcomes of neuromodulation therapies for pain, such as spinal cord stimulation. Here, we show that in a male rat model of neuropathic pain produced by spared nerve injury (SNI), 1 kHz spinal cord stimulation (1 kHz SCS) alone was sufficient to reduce mechanical allodynia and increase RvD1 in the cerebrospinal fluid (CSF). SNI resulted in robust and persistent mechanical allodynia and cold allodynia. Spinal cord electrode implantation was conducted at the T11-T13 vertebral level 1 week after SNI. The spinal locations of the implanted electrodes were validated by X-Ray radiography. 1 kHz SCS was applied for 6 h at 0.1 ms pulse-width, and this stimulation alone was sufficient to effectively reduce nerve injury-induced mechanical allodynia during stimulation without affecting SNI-induced cold allodynia. SCS alone significantly reduced interleukin-1ß levels in both serum and CSF samples. Strikingly, SCS significantly increased RvD1 levels in the CSF but not serum. Finally, intrathecal injection of RvD1 (100 and 500 ng, i.t.) 4 weeks after nerve injury reduced SNI-induced mechanical allodynia in a dose-dependent manner. Our findings suggest that 1 kHz SCS may alleviate neuropathic pain via reduction of IL-1ß and via production and/or release of RvD1 to control SNI-induced neuroinflammation.

2.
eNeuro ; 7(6)2020.
Artículo en Inglés | MEDLINE | ID: mdl-33328248

RESUMEN

Understanding the cellular mechanisms of kilohertz (kHz) electrical stimulation is of broad interest in neuromodulation including forms of transcranial electrical stimulation, interferential stimulation, and high-rate spinal cord stimulation (SCS). Yet, the well-established low-pass filtering by neuronal membranes suggests minimal neuronal polarization in respond to charge-balanced kHz stimulation. The hippocampal brain slice model is among the most studied systems in neuroscience and exhaustively characterized in screening the effects of electrical stimulation. High-frequency electric fields of varied amplitudes (1-150 V/m), waveforms (sinusoidal, symmetrical pule, asymmetrical pulse) and frequencies (1 and10 kHz) were tested. Changes in single or paired-pulse field EPSPs (fEPSP) in CA1 were measured in response to radial-directed and tangential-directed electric fields, with brief (30 s) or long (30 min) application times. The effects of kHz stimulation on ongoing endogenous network activity were tested in carbachol-induced γ oscillation of CA3a and CA3c. Across 23 conditions evaluated, no significant changes in fEPSP were resolved, while responses were detected for within-slice control direct current (DC) fields; 1-kHz sinusoidal and pulse stimulation (≥60 V/m), but not 10 kHz, induced changes in oscillating neuronal network. We thus report no responses to low-amplitude 1-kHz or any 10-kHz fields, suggesting that any brain sensitivity to these fields is via yet to be-determined mechanism(s) of action which were not identified in our experimental preparation.


Asunto(s)
Hipocampo , Estimulación Transcraneal de Corriente Directa , Encéfalo , Estimulación Eléctrica , Neuronas
3.
Neuromodulation ; 23(5): 687-697, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31747105

RESUMEN

OBJECTIVE: To identify relationships between clinical assessments of chronic pain to enable the generation of a multivariate model to predict patient satisfaction with spinal cord stimulation (SCS) treatment. MATERIALS AND METHODS: Data from an exploratory clinical trial of sub-perception SCS (SPSCS) were reviewed. Forty-seven subjects tested multiple SPSCS programs for three to four days each. At the end of each program period, subjects recorded pain intensity, patient satisfaction with treatment (PSWT), modified patient global impression of change, and physical activity tolerance times. Twelve outcome variables were evaluated. Pearson's correlation coefficient was used to assess pair-wise correlations. Multigenerational mixed effects modeling was performed to create a model to best explain relationships between those variables. RESULTS: A final model was generated that predicted PSWT using evening pain intensity (EPI) and the interaction between EPI and walking tolerance time. The mixed effects model allows for visualization of the interactions between EPI, walking tolerance time, and patient satisfaction with SCS. CONCLUSIONS: Patient-centered outcomes are desirable when evaluating complex multidimensional health impairments but accurately predicting patient satisfaction with treatment remains a challenge. Understanding the variables that predict (either by causation or association) satisfaction would be useful for clinicians. The results of this study suggest that a composite measure of activity tolerance (i.e., walking tolerance) and pain intensity can predict patient satisfaction with SCS therapy. This study highlights the utility of composite outcomes metrics in evaluating the benefits of SCS for chronic low back and leg pain.


Asunto(s)
Dolor Crónico , Satisfacción del Paciente , Estimulación de la Médula Espinal , Dolor Crónico/terapia , Humanos , Pierna , Dolor de la Región Lumbar/terapia , Evaluación de Resultado en la Atención de Salud , Psicometría , Médula Espinal , Resultado del Tratamiento
4.
J Physiol ; 597(8): 2131-2137, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30816558

RESUMEN

Characterizing the cellular targets of kHz (1-10 kHz) electrical stimulation remains a pressing topic in neuromodulation because expanding interest in clinical application of kHz stimulation has surpassed mechanistic understanding. The presumed cellular targets of brain stimulation do not respond to kHz frequencies according to conventional electrophysiology theory. Specifically, the low-pass characteristics of cell membranes are predicted to render kHz stimulation inert, especially given the use of limited-duty-cycle biphasic pulses. Precisely because kHz frequencies are considered supra-physiological, conventional instruments designed for neurophysiological studies such as stimulators, amplifiers and recording microelectrodes do not operate reliably at these high rates. Moreover, for pulsed waveforms, the signal frequency content is well above the pulse repetition rate. Thus, the very tools used to characterize the effects of kHz electrical stimulation may themselves be confounding factors. We illustrate custom equipment design that supports reliable electrophysiological recording during kHz-rate stimulation. Given the increased importance of kHz stimulation in clinical domains and compelling possibilities that mechanisms of actions may reflect yet undiscovered neurophysiological phenomena, attention to suitable performance of electrophysiological equipment is pivotal.


Asunto(s)
Estimulación Eléctrica/instrumentación , Fenómenos Electrofisiológicos , Microelectrodos
5.
Brain Stimul ; 12(1): 62-72, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30482674

RESUMEN

INTRODUCTION: Kilohertz frequency spinal cord stimulation (kHz-SCS) deposits significantly more power in tissue compared to SCS at conventional frequencies, reflecting increased duty cycle (pulse compression). We hypothesize kHz-SCS increases local tissue temperature by joule heat, which may influence the clinical outcomes. METHODS: To establish the role of tissue heating in KHZ-SCS, a decisive first step is to characterize the range of temperature changes expected during conventional and KHZ-SCS protocols. Fiber optic probes quantified temperature increases around an experimental SCS lead in a bath phantom. These data were used to verify a SCS lead heat-transfer model based on joule heat. Temperature increases were then predicted in a seven-compartment (soft tissue, vertebral bone, fat, intervertebral disc, meninges, spinal cord with nerve roots) geometric human spinal cord model under varied parameterization. RESULTS: The experimentally constrained bio-heat model shows SCS waveform power (waveform RMS) determines tissue heating at the spinal cord and surrounding tissues. For example, we predict temperature increased at dorsal spinal cord of 0.18-1.72 °C during 3.5 mA peak 10 KHz stimulation with a 40-10-40 µs biphasic pulse pattern, 0.09-0.22 °C during 3.5 mA 1 KHz 100-100-100 µs stimulation, and less than 0.05 °C during 3.5 mA 50 Hz 200-100-200 µs stimulation. Notably, peak heating of the spinal cord and other tissues increases superlinearly with stimulation power and so are especially sensitive to incremental changes in SCS pulse amplitude or frequency (with associated pulse compression). Further supporting distinct SCS intervention strategies based on heating; the spatial profile of temperature changes is more uniform compared to electric fields, which suggests less sensitivity to lead position. CONCLUSIONS: Tissue heating may impact short and long-term outcomes of KHZ-SCS, and even as an adjunct mechanism, suggests distinct strategies for lead position and programming optimization.


Asunto(s)
Temperatura Corporal , Calor , Estimulación de la Médula Espinal/efectos adversos , Humanos , Médula Espinal/fisiología , Estimulación de la Médula Espinal/métodos
6.
Pain Med ; 19(7): 1425-1435, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29474648

RESUMEN

OBJECTIVE: Despite the high prevalence of chronic multisite pain, there is little consensus on methods to characterize it. Commonly used assessments report only one dimension of pain, that is, intensity, thus ignoring the spatial aspect of pain. We developed a novel pain quantification index, the Integrated Pain Quantification Index (IPQI), on a scale of 0 to 1 that integrates multiple distinct pain measures into a single value, thus representing multidimensional pain information with a single value. DESIGN: Single-visit, noninterventional, epidemiological study. SETTING: Fourteen outpatient multidisciplinary pain management programs. PATIENTS: Patients with chronic pain of the trunk and/or limbs for at least six months with average overall pain intensity of at least 5 on the numeric rating scale. METHODS: Development of IPQI was performed in a large population (N = 810) of chronic pain patients from the Multiple Areas of Pain (MAP) study. RESULTS: Prevalence of two or more noncontiguous painful areas was at 88.3% (95% confidence interval [CI] = 0.86-0.90), with a mean of 6.3 areas (SD = 5.57 areas). Prevalence of more than 10% body area in pain was at 52.8% (95% CI = 0.49-0.56), with a mean at 16.1% (17.16%). On average, IPQI values were near the middle of the scale, with mean and median IPQI at 0.52 (SD = 0.13) and 0.55, respectively. The IPQI was generalizable and clinically relevant across all domains recommended by the Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials. CONCLUSIONS: IPQI provided a single pain score for representing complex, multidimensional pain information on one scale and has implications for comparing pain populations across longitudinal clinical trials.


Asunto(s)
Dolor Crónico/diagnóstico , Dimensión del Dolor/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios , Adulto Joven
7.
Med Biol Eng Comput ; 49(7): 765-74, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21528381

RESUMEN

To understand the theoretical effects of pulse width (PW) programming in spinal cord stimulation (SCS), we implemented a mathematical model of electrical fields and neural activation in SCS to gain insight into the effects of PW programming. The computational model was composed of a finite element model for structure and electrical properties, coupled with a nonlinear double-cable axon model to predict nerve excitation for different myelinated fiber sizes. Mathematical modeling suggested that mediolateral lead position may affect chronaxie and rheobase values, as well as predict greater activation of medial dorsal column fibers with increased PW. These modeling results were validated by a companion clinical study. Thus, variable PW programming in SCS appears to have theoretical value, demonstrated by the ability to increase and even 'steer' spatial selectivity of dorsal column fiber recruitment. It is concluded that the computational SCS model is a valuable tool to understand basic mechanisms of nerve fiber excitation modulated by stimulation parameters such as PW and electric fields.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Modelos Neurológicos , Médula Espinal/fisiología , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/fisiología , Parestesia/fisiopatología
8.
Pain Physician ; 13(4): 321-35, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20648201

RESUMEN

BACKGROUND: With advances in spinal cord stimulation (SCS) technology, particularly rechargeable implantable, patients are now being offered a wider range of parameters to treat their pain. In particular, pulse width (PW) programming ranges of rechargeable implantable pulse generators now match that of radiofrequency systems (with programmability up to 1000 microseconds. The intent of the present study was to investigate the effects of varying PW in SCS. OBJECTIVE: To understand the effects of PW programming in spinal cord stimulation (SCS). DESIGN: Single-center, prospective, randomized, single-blind evaluation of the technical and clinical outcomes of PW programming. SETTING: Acute, outpatient follow-up. METHODS: Subjects using fully-implanted SCS for > 3 months to treat chronic intractable low back and/or leg pain. Programming of a wide range (50-1000 microseconds) of programmed PW settings using each patient's otherwise unchanged 'walk-in' program. OUTCOME MEASURES: Paresthesia thresholds (perception, maximum comfortable, discomfort), paresthesia coverage and patient choice of tested programs. RESULTS: We found strength-duration parameters of chronaxie and rheobase to be 295 (242 - 326) microseconds and 2.5 (1.3 - 3.3) mA, respectively. The median PW of all patients' 'walk-out' programs was 400 microseconds, approximately 48% higher than median chronaxie (p = 0.01), suggesting that chronaxie may not relate to patient-preferred stimulation settings. We found that 7/19 patients selected new PW programs, which significantly increased their paresthesia-pain overlap by 56% on average (p = 0.047). We estimated that 10/19 patients appeared to have greater paresthesia coverage, and 8/19 patients appeared to display a 'caudal shift' of paresthesia coverage with increased PW. LIMITATIONS: Small number of patients. CONCLUSIONS: Variable PW programming in SCS appears to have clinical value, demonstrated by some patients improving their paresthesia-pain overlap, as well as the ability to increase and even 'steer' paresthesia coverage.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Dolor de la Región Lumbar/terapia , Implantación de Prótesis/métodos , Ciática/terapia , Programas Informáticos , Médula Espinal/cirugía , Terapia por Estimulación Eléctrica/efectos adversos , Electrodos Implantados/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud/métodos , Dimensión del Dolor/métodos , Parestesia/etiología , Parestesia/prevención & control , Estudios Prospectivos , Implantación de Prótesis/instrumentación , Método Simple Ciego , Programas Informáticos/normas , Resultado del Tratamiento
9.
J Org Chem ; 68(16): 6387-91, 2003 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-12895075

RESUMEN

The effects of lithium dialkylamide structure, mixed aggregate formation, and solvation on the stereoselectivity of ketone enolization were examined. Of the lithium dialkylamides examined, lithium tetramethylpiperidide (LiTMP) in THF resulted in the best enolization selectivity. The stereoselectivity was further improved in the presence of a LiTMP-butyllithium mixed aggregate. The use of less polar solvents reduced the enolization stereoselectivity. Ab initio calculations predict LDA and LiTMP to form mixed cyclic dimers in ethereal solvents. The calculations also predict LiTMP-alkyllithium mixed aggregates to competitively inhibit the formation of less stereoselective LiTMP-lithium enolate mixed aggregates.


Asunto(s)
Cetonas/química , Compuestos de Litio/química , Fenómenos Químicos , Química Física , Cromatografía de Gases y Espectrometría de Masas , Espectroscopía de Resonancia Magnética , Conformación Molecular , Compuestos Organometálicos/química , Propilaminas/química , Solventes , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA