Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Philos Trans A Math Phys Eng Sci ; 376(2116)2018 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-29459412

RESUMEN

The goal of the ASACUSA-CUSP collaboration at the Antiproton Decelerator of CERN is to measure the ground-state hyperfine splitting of antihydrogen using an atomic spectroscopy beamline. A milestone was achieved in 2012 through the detection of 80 antihydrogen atoms 2.7 m away from their production region. This was the first observation of 'cold' antihydrogen in a magnetic field free region. In parallel to the progress on the antihydrogen production, the spectroscopy beamline was tested with a source of hydrogen. This led to a measurement at a relative precision of 2.7×10-9 which constitutes the most precise measurement of the hydrogen hyperfine splitting in a beam. Further measurements with an upgraded hydrogen apparatus are motivated by CPT and Lorentz violation tests in the framework of the Standard Model Extension. Unlike for hydrogen, the antihydrogen experiment is complicated by the difficulty of synthesizing enough cold antiatoms in the ground state. The first antihydrogen quantum states scan at the entrance of the spectroscopy apparatus was realized in 2016 and is presented here. The prospects for a ppm measurement are also discussed.This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'.

2.
Orthop Traumatol Surg Res ; 104(2): 177-183, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29274859

RESUMEN

BACKGROUND: Rotational allowance at the tibiofemoral joint would be required during deep flexion. However, the amount of flexion and rotation has not been investigated in modern total knee arthroplasty (TKA) designs. The present study aimed to determine the contact stress in five posterior-stabilized fixed-bearing TKA designs. HYPOTHESIS: We hypothesized that the contact area and stresses at the tibiofemoral articular surfaces vary according to the type of implant design and tested condition. MATERIALS AND METHODS: The contact area and mean and peak contact stresses at the tibiofemoral articular surfaces were determined when a compressive load of 1200N was applied to a NexGen LPS Flex, Scorpio NRG, Genesis II, PFC Sigma, and Foundation implant. Measurements were performed at 0° and 45° flexion with 0°, 5°, 10°, and 15° rotation, and at 90° and 135° flexion with 0, 5°, 10°, 15°, and 20° rotation. RESULTS: The LPS Flex showed that the femoral component could not achieve 20° rotation at 135° flexion. The Scorpio NRG showed less than 20MPa of contact stress at all conditions. The Genesis II showed higher contact stress than 20MPa at 135° flexion with 20° rotation. The PFC Sigma showed that the femoral component could not achieve >10° rotation at any flexion angle. The Foundation showed more than 20MPa of contact stress at 90° flexion with 20° rotation and at 135° flexion with 10°, 15°, and 20° rotation. DISCUSSION: Surgeons should be more aware of the variable contact conditions of the tibiofemoral articular surfaces in individual TKA designs. LEVEL OF EVIDENCE: Level IV, basic science study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Diseño de Prótesis , Estrés Mecánico , Fenómenos Biomecánicos , Fémur , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Ensayo de Materiales , Rango del Movimiento Articular , Rotación , Tibia
3.
J Hand Surg Asian Pac Vol ; 22(2): 208-213, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28506161

RESUMEN

BACKGROUND: The fatigue strength of three peripheral suture techniques for flexor tendon repair was compared by cyclic loading of the repairs in the porcine flexor digitorum tendon. METHODS: Thirty-six tendons were sutured using only peripheral sutures with 6-0 Nylon. An initial cyclic load of 10 N for 500 cycles was applied and increased by 10 N for an additional 500 cycles at each new load until rupture. RESULTS: The fatigue strength of the symmetric running peripheral suture was 85.0% and 144.8% greater than that of the two kinds of the asymmetric running peripheral sutures. CONCLUSIONS: Symmetric running sutures can enhance the suture strength and appears to be a useful technique for increasing the strength of the peripheral suture.


Asunto(s)
Técnicas de Sutura , Suturas , Tendones/cirugía , Animales , Fenómenos Biomecánicos , Caprolactama/análogos & derivados , Polímeros , Porcinos , Resistencia a la Tracción , Técnicas de Cultivo de Tejidos
4.
Phys Rev E ; 94(4-1): 043204, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27841648

RESUMEN

The existence of autoresonances for m=2 diocotron oscillations of non-neutral electron plasmas in a uniform magnetic field was predicted by particle-in-cell simulations and it was confirmed in experiments. The obtained results show clear deviations from the standard threshold amplitude dependence on the sweep rate. The threshold amplitude approaches a constant at a lower sweep rate when there is a damping force. It was also found that the aspect ratio for the oval cross section of the confined plasma can be controlled by the frequency of the externally applied driving force.

5.
Nat Commun ; 5: 3089, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24448273

RESUMEN

Antihydrogen, a positron bound to an antiproton, is the simplest antiatom. Its counterpart-hydrogen--is one of the most precisely investigated and best understood systems in physics research. High-resolution comparisons of both systems provide sensitive tests of CPT symmetry, which is the most fundamental symmetry in the Standard Model of elementary particle physics. Any measured difference would point to CPT violation and thus to new physics. Here we report the development of an antihydrogen source using a cusp trap for in-flight spectroscopy. A total of 80 antihydrogen atoms are unambiguously detected 2.7 m downstream of the production region, where perturbing residual magnetic fields are small. This is a major step towards precision spectroscopy of the ground-state hyperfine splitting of antihydrogen using Rabi-like beam spectroscopy.

6.
J Bone Joint Surg Br ; 94(1): 56-61, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22219248

RESUMEN

In posterior stabilised total knee replacement (TKR) a larger femoral component is sometimes selected to manage the increased flexion gap caused by resection of the posterior cruciate ligament. However, concerns remain regarding the adverse effect of the increased anteroposterior dimensions of the femoral component on the patellofemoral (PF) joint. Meanwhile, the gender-specific femoral component has a narrower and thinner anterior flange and is expected to reduce the PF contact force. PF contact forces were measured at 90°, 120°, 130° and 140° of flexion using the NexGen Legacy Posterior Stabilized (LPS)-Flex Fixed Bearing Knee system using Standard, Upsized and Gender femoral components during TKR. Increasing the size of the femoral component significantly increased mean PF forces at 120°, 130° and 140° of flexion (p = 0.005, p < 0.001 and p < 0.001, respectively). No difference was found in contact force between the Gender and the Standard components. Among the patients who had overhang of the Standard component, mean contact forces with the Gender component were slightly lower than those of the Standard component, but no statistical difference was found at 90°, 120°, 130° or 140° of flexion (p = 0.689, 0.615, 0.253 and 0.248, respectively). Upsized femoral components would increase PF forces in deep knee flexion. Gender-specific implants would not reduce PF forces.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Articulación Patelofemoral/fisiopatología , Anciano , Anciano de 80 o más Años , Antropometría/métodos , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Rango del Movimiento Articular/fisiología , Factores Sexuales , Estrés Mecánico
7.
J Hand Surg Eur Vol ; 36(7): 584-9, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21546417

RESUMEN

The gap formation of five core plus peripheral suture techniques for flexor tendon repair was evaluated by cyclic load testing. Fifty pairs of dental roll tendon models were sutured using six-strand Pennington modified Kessler core suture with 4-0 Polypropylene. One-half or three-fourths circumferential interlocking cross-stitch, or three complete circumferential peripheral suture techniques were performed using 6-0 Polypropylene. An initial cyclic load of 10 N for 500 cycles was applied and increased by 5 N for an additional 500 cycles at each new load until rupture. The complete circumferential interlocking cross-stitch had the greatest fatigue strength. The partial circumferential cross-stitches resulted in significantly larger gap formations at both the repaired and unrepaired sides than the complete circumferential sutures, and were also associated with early rupture. The full circumference of the cut tendon must be sutured using an interlocking cross-stitch peripheral suture to improve strength and avoid gap formation.


Asunto(s)
Traumatismos de los Dedos/cirugía , Técnicas de Sutura , Traumatismos de los Tendones/cirugía , Fenómenos Biomecánicos , Traumatismos de los Dedos/fisiopatología , Humanos , Polipropilenos , Estrés Mecánico , Traumatismos de los Tendones/fisiopatología , Resultado del Tratamiento
8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 81(1 Pt 2): 016401, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20365479

RESUMEN

Low-energy non-neutral electron plasmas were confined with an electrostatic potential and a magnetic mirror field of the mirror ratio up to 5. Using a conventional phosphor screen and the unique multiring trap, both radial and axial density profiles of plasmas were measured. With the present experimental parameters, it was confirmed that a plasma density increased at higher field with an electrostatic confinement and that it decreased at higher field with a magnetic mirror confinement. The electrostatic potentials along the magnetic field were estimated with computer simulations.

9.
Phys Rev Lett ; 105(24): 243401, 2010 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-21231524

RESUMEN

We report here the first successful synthesis of cold antihydrogen atoms employing a cusp trap, which consists of a superconducting anti-Helmholtz coil and a stack of multiple ring electrodes. This success opens a new path to make a stringent test of the CPT symmetry via high precision microwave spectroscopy of ground-state hyperfine transitions of antihydrogen atoms.

10.
J Hand Surg Eur Vol ; 35(1): 46-50, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19786410

RESUMEN

The fatigue strength of three peripheral suture techniques for flexor tendon repair was compared by cyclic loading of repairs in a cotton dental roll tendon model. Thirty pairs of dental roll were sutured using only peripheral sutures with 6-0 polypropylene. An initial cyclic load of 5 N for 500 cycles was applied and increased by 5 N for an additional 500 cycles at each new load until rupture. The fatigue strength of an interlocking cross-stitch suture was 113% greater than a running suture and 36% greater than a standard cross-stitch suture. Interlocking the cross-stitch prevented shortening of the transverse portions under load and appears to be a useful technique for increasing the strength of the peripheral suture.


Asunto(s)
Técnicas de Sutura , Tendones/cirugía , Resistencia a la Tracción , Fenómenos Biomecánicos , Modelos Anatómicos , Soporte de Peso
11.
J Bone Joint Surg Br ; 90(9): 1180-5, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18757957

RESUMEN

Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the anterior tibial post was evaluated in vivo in three dimensions during gait using radiologically-based image-matching techniques. Impingement was observed in all images of the patients during the stance phase, although the NexGen LPS was designed to accommodate 14 degrees of hyperextension of the component before impingement occurred. Impingement arises as a result of posterior translation of the femur during the stance phase. Further attention must therefore be given to the configuration of the anterior portion of the femoral component and the polyethylene post when designing posteriorly-stabilised total knee replacements.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Marcha , Prótesis de la Rodilla/efectos adversos , Diseño de Prótesis/efectos adversos , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Pierna/diagnóstico por imagen , Huesos de la Pierna/diagnóstico por imagen , Masculino , Radiografía
12.
Phys Rev E Stat Nonlin Soft Matter Phys ; 75(6 Pt 2): 066401, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17677366

RESUMEN

A low energy non-neutral electron plasma was confined with a magnetic mirror field and an electrostatic potential to investigate the basic confinement properties of a simple magnetic mirror trap. The mirror ratio of the magnetic field was increased up to 5. As expected the confinement time became longer as a function of the mirror ratio. The axially integrated radial density profiles in equilibrium were measured and compared with a theoretical model. The axial electrostatic oscillations of a confined electron plasma were also observed.

13.
Phys Rev Lett ; 97(5): 055001, 2006 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-17026107

RESUMEN

Off-axis electron-cyclotron heating in an axisymmetric barrier mirror produces a cylindrical layer with energetic electrons, which flow through the central cell and into the end region. The layer, producing a localized bumped ambipolar potential Phi(C), forms a strong shear of radial electric fields E(r) and peaked vorticity with the direction reversal of E(r)xB sheared flow near the Phi(C) peak. Intermittent vortexlike turbulent structures near the layer are suppressed in the central cell by this actively produced transverse energy-transport barrier; this results in T(e) and T(i) rises surrounded by the layer.

14.
Phys Rev Lett ; 94(8): 085002, 2005 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-15783899

RESUMEN

Vortexlike turbulent structures in hot-ion mode plasmas with several keV are observed in the case with a radially produced weak shear of electric fields E(r). However, a strong E(r) shear formation due to a high ion-confining potential phi(c) production clears up these vortices together with plasma-confinement improvement and disappearance of both drift-wave and turbulencelike Fourier spectral signals. These findings are based on three-time progress in phi(c) in comparison to phi(c) attained 1992-2002. The significant advance of phi(c) is well extended in line with proposed potential-formation physics scalings.

15.
J Bone Joint Surg Br ; 87(4): 483-8, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15795197

RESUMEN

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90 degrees, 120 degrees, and 150 degrees of flexion both in neutral rotation and 10 degrees of internal rotation of the tibial component. Peak contact stresses at 90 degrees, 120 degrees, and 150 degrees were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Articulación de la Rodilla/fisiología , Diseño de Prótesis , Rango del Movimiento Articular , Estrés Mecánico
16.
Phys Rev Lett ; 94(2): 023401, 2005 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-15698175

RESUMEN

We have used a radio frequency quadrupole decelerator to decelerate antiprotons emerging from the CERN Antiproton Decelerator from MeV- to keV-scale energy, and collected five decelerated pulses in a multiring trap. Some 5 x 10(6) antiprotons were stacked in this way. Cooling of the trapped antiprotons by a simultaneously trapped electron plasma was studied nondestructively via shifts in plasma mode frequencies. We have also demonstrated the first step in extracting a 10-500 eV antiproton beam from the trap.

17.
Phys Rev E Stat Nonlin Soft Matter Phys ; 70(2 Pt 2): 026501, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15447603

RESUMEN

Radial compression of a proton cloud was performed in a multiring trap which was designed to trap and cool a large number of antiprotons for the production of low-energy ( 10-1000 eV ) antiproton beams. The resonance frequency for the radial compression was almost constant from 3 x 10(5) to 3 x 10(6) protons. The collision process of the trapped protons was also investigated to estimate the energy of the protons inside the trap. This technique will be applied to the ASACUSA experiment at the antiproton decelerator, CERN, to extract ultraslow antiprotons with good emittance.

18.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(4 Pt 2B): 046410, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12006026

RESUMEN

Electron cooling of energetic protons in a multiring trap was investigated experimentally with a tank circuit monitoring electron-plasma oscillations in the trap. The energy of protons was determined by time-of-flight measurements. It is found that a simple model can explain the qualitative behavior of both electron and proton energy when the initial energy of protons is less than 2 keV. Monitoring the electron-plasma temperature with a tank circuit can be an effective tool when energetic particles are electron cooled in a multiring trap.

19.
J Bone Miner Res ; 16(4): 722-30, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11316000

RESUMEN

Adaptive modeling and remodeling are controlled by the activities of osteoblasts and osteoclasts, which are capable of sensing their mechanical environments and regulating deposition or resorption of bone matrix. The effects of mechanical stimuli on isolated osteoclasts have been scarcely examined because it has proven to be difficult to prepare a number of pure osteoclasts and to cultivate them on mineralized substratum during mechanical stimulation. Recently, we developed an apparatus for applying mechanical stretching to the ivory slice/plastic plate component on which cells could be cultured. The loading frequency, strain rate, and generated strain over an ivory surface could be controlled by a personal computer. Using this apparatus, we examined the role of mechanical stretching on the bone-resorbing activity of the osteoclasts. Mature and highly enriched osteoclasts were cultured for 2, 12, and 24 h on the ivory/plate component while being subjected to intermittent tensile strain. The stretched osteoclasts showed enhanced messenger RNA (mRNA) expression levels of osteoclast marker enzymes, tartrate-resistant acid phosphatase (TRAP), and cathepsin K and increases of resorbed-pit formation, suggesting that the mechanical stretching up-regulated the bone-resorbing activity of the osteoclasts. A stretch-activated cation (SA-cat) channel blocker significantly inhibited the increases of the mRNA level and pit formation after 24 h of stretching. This study suggested the possibility that the mature osteoclasts responded to mechanical stretching through a mechanism involving a SA-cat channel in the absence of mesenchymal cells and, as a result, up-regulated their bone-resorbing activity.


Asunto(s)
Fosfatasa Ácida/biosíntesis , Resorción Ósea , Catepsinas/biosíntesis , Regulación de la Expresión Génica , Isoenzimas/biosíntesis , Osteoclastos/metabolismo , ARN Mensajero/biosíntesis , Estrés Mecánico , Fosfatasa Ácida/genética , Animales , Biomarcadores , Catepsina K , Catepsinas/genética , Cationes/metabolismo , Adhesión Celular , Células Cultivadas , Inducción Enzimática , Gadolinio/farmacología , Gliceraldehído-3-Fosfato Deshidrogenasas/biosíntesis , Gliceraldehído-3-Fosfato Deshidrogenasas/genética , Canales Iónicos/metabolismo , Transporte Iónico , Isoenzimas/genética , Conejos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Fosfatasa Ácida Tartratorresistente
20.
J Orthop Res ; 18(5): 835-40, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11117308

RESUMEN

Dipalmitoyl phosphatidylcholine, a highly surface-active polar lipid, has been implicated as a potential boundary lubricant for synovial joints. We examined the effects of dipalmitoyl phosphatidylcholine on the flexor tendon and its protective effect against postoperative adhesion in two experimental steps. First, the flexor digitorum fibularis and the distal pulley of rabbits were set for a friction test. The test was performed with saline solution, sodium hyaluronate, or a mixture of dipalmitoyl phosphatidylcholine and sodium hyaluronate as the lubricant. The friction coefficient was significantly lower with the mixture of dipalmitoyl phosphatidylcholine and sodium hyaluronate than with saline solution or sodium hyaluronate. We concluded that the decreased friction coefficient indicates that dipalmitoyl phosphatidylcholine could complement the boundary-lubricating ability of the tendon. In the second experiment, we used an experimental adhesion model of the flexor digitorum fibularis in the rabbit. During the operation, either saline solution, sodium hyaluronate, or a mixture of dipalmitoyl phosphatidylcholine and sodium hyaluronate was injected into the tendon sheath. The specimen was sent to another tester, and the work required to tear off the adhesion was measured. The work required was significantly greater for the tendons that had been injected with saline solution than for those given injections of dipalmitoyl phosphatidylcholine and sodium hyaluronate. Our findings suggest that dipalmitoyl phosphatidylcholine plays an important role in the boundary lubrication of the tendon and that after tendon injury, the administration of a mixture of dipalmitoyl phosphatidylcholine and sodium hyaluronate may improve tendon lubrication and prevent adhesion formation.


Asunto(s)
1,2-Dipalmitoilfosfatidilcolina/farmacología , Ácido Hialurónico/farmacología , Complicaciones Posoperatorias/prevención & control , Tendones/efectos de los fármacos , Adherencias Tisulares/prevención & control , Animales , Quimioterapia Combinada , Fricción , Miembro Posterior , Microscopía Electrónica de Rastreo , Modelos Animales , Complicaciones Posoperatorias/patología , Conejos , Estrés Mecánico , Articulaciones Tarsianas/patología , Articulaciones Tarsianas/cirugía , Tendones/cirugía , Tendones/ultraestructura , Adherencias Tisulares/patología , Soporte de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...