Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 351
Filtrar
1.
EuroIntervention ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38752714

RESUMEN

The 2023 European Bifurcation Club (EBC) meeting took place in Warsaw in October, and the latest evidence for the use of intravascular ultrasound (IVUS) and optical coherence tomography (OCT) to optimise percutaneous coronary interventions (PCI) on coronary bifurcation lesions (CBLs) was a major focus. The topic generated deep discussions and general appraisal on the potential benefits of IVUS and OCT in PCI procedures. Nevertheless, despite an increasing recognition of IVUS and OCT capabilities and their recognised central role for guidance in complex CBL and left main PCI, it is expected that angiography will continue to be the primary guidance modality for CBL PCI, principally due to educational and economic barriers. Mindful of the restricted access/adoption of intracoronary imaging for CBL PCI, the EBC board decided to review and describe a series of tips and tricks which can help to optimise angiography-guided PCI for CBLs. The identified key points for achieving an optimal angiography-guided PCI include a thorough analysis of pre-PCI images (computed tomography angiography, multiple angiographic views, quantitative coronary angiography vessel estimation), a systematic application of the technical steps suggested for a given selected technique, an intraprocedural or post-PCI use of stent enhancement and a low threshold for bailout use of intravascular imaging.

2.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

3.
Clin Res Cardiol ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619575

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

4.
Eur Heart J ; 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38596853

RESUMEN

BACKGROUND AND AIMS: Older patients with non-ST-elevation acute coronary syndrome (NSTEACS) are less likely to receive guideline-recommended care including coronary angiography and revascularization. Evidence-based recommendations regarding interventional management strategies in this patient cohort are scarce. This meta-analysis aimed to assess the impact of routine invasive vs. conservative management of NSTEACS by using individual patient data (IPD) from all available randomized controlled trials (RCTs) including older patients. METHODS: MEDLINE, Web of Science and Scopus were searched between 1 January 2010 and 11 September 2023. RCTs investigating routine invasive and conservative strategies in persons >70 years old with NSTEACS were included. Observational studies or trials involving populations outside the target range were excluded. The primary endpoint was a composite of all-cause mortality and myocardial infarction (MI) at 1 year. One-stage IPD meta-analyses were adopted by use of random-effects and fixed-effect Cox models. This meta-analysis is registered with PROSPERO (CRD42023379819). RESULTS: Six eligible studies were identified including 1479 participants. The primary endpoint occurred in 181 of 736 (24.5%) participants in the invasive management group compared with 215 of 743 (28.9%) participants in the conservative management group with a hazard ratio (HR) from random-effects model of 0.87 (95% CI 0.63-1.22; P = .43). The hazard for MI at 1 year was significantly lower in the invasive group compared with the conservative group (HR from random-effects model 0.62, 95% CI 0.44-0.87; P = .006). Similar results were seen for urgent revascularization (HR from random-effects model 0.41, 95% CI 0.18-0.95; P = .037). There was no significant difference in mortality. CONCLUSIONS: No evidence was found that routine invasive treatment for NSTEACS in older patients reduces the risk of a composite of all-cause mortality and MI within 1 year compared with conservative management. However, there is convincing evidence that invasive treatment significantly lowers the risk of repeat MI or urgent revascularisation. Further evidence is needed from ongoing larger clinical trials.

5.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479966

RESUMEN

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Accidente Cerebrovascular Isquémico/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
6.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38533944

RESUMEN

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Diabetes Mellitus , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros , Diálisis Renal , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
7.
Interv Cardiol ; 19: e02, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38532943

RESUMEN

Percutaneous left atrial appendage occlusion aims to reduce the risk of stroke in patients with AF, particularly those who are not good candidates for systemic anticoagulation. The procedure has been studied in large international randomised trials and registries and was approved by the National Institute for Health and Care Excellence in 2014 and by NHS England in 2018. This position statement summarises the evidence for left atrial appendage occlusion and presents the current indications. The options and consensus on best practice for pre-procedure planning, undertaking a safe and effective implant and appropriate post-procedure management and follow-up are described. Standards regarding procedure volume for implant centres and physicians, the role of multidisciplinary teams and audits are highlighted.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38544812

RESUMEN

Percutaneous left atrial appendage occlusion aims to reduce the risk of stroke in patients with AF, particularly those who are not good candidates for systemic anticoagulation. The procedure has been studied in large international randomised trials and registries and was approved by the National Institute for Health and Care Excellence in 2014 and by NHS England in 2018. This position statement summarises the evidence for left atrial appendage occlusion and presents the current indications. The options and consensus on best practice for pre-procedure planning, undertaking a safe and effective implant and appropriate post-procedure management and follow-up are described. Standards regarding procedure volume for implant centres and physicians, the role of multidisciplinary teams and audits are highlighted.

9.
Open Heart ; 11(1)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38242557

RESUMEN

BACKGROUND: In patients with distal bifurcation left main stem lesions requiring intervention, the European Bifurcation Club Left Main Coronary Stent Study trial found a non-significant difference in major adverse cardiac events (MACEs, composite of all-cause death, non-fatal myocardial infarction and target lesion revascularisation) favouring the stepwise provisional strategy, compared with the systematic dual stenting. AIMS: To estimate the 1-year cost-effectiveness of stepwise provisional versus systematic dual stenting strategies. METHODS: Costs in France and the UK, and MACE were calculated in both groups to estimate the incremental cost-effectiveness ratio (ICER). Uncertainty was explored by probabilistic bootstrapping. The analysis was conducted from the perspective of the healthcare provider with a time horizon of 1 year. RESULTS: The cost difference between the two groups was €-755 (€5700 in the stepwise provisional group and €6455 in the systematic dual stenting group, p value<0.01) in France and €-647 (€6728 and €7375, respectively, p value=0.08) in the UK. The point estimates for the ICERs found that stepwise provisional strategy was cost saving and improved outcomes with a probabilistic sensitivity analysis confirming dominance with an 80% probability. CONCLUSION: The stepwise provisional strategy at 1 year is dominant compared with the systematic dual stenting strategy on both economic and clinical outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Análisis Costo-Beneficio , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Stents
11.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38180419

RESUMEN

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pandemias , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Resultado del Tratamiento , COVID-19/epidemiología , Sistema de Registros , Factores de Riesgo
12.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37968032

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Asunto(s)
Fibrilación Atrial , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Constricción Patológica/etiología , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Hemodinámica , Sistema de Registros , Diseño de Prótesis
13.
EuroIntervention ; 2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37946522

RESUMEN

BACKGROUND: The multicentre European Bifurcation Club Trial (EBC TWO) showed no significant differences in 12-month clinical outcomes between patients randomised to a provisional stenting strategy or systematic culotte stenting in non-left main true bifurcations. AIMS: This study aimed to investigate the 5-year clinical results of the EBC TWO Trial. METHODS: A total of 200 patients undergoing stent implantation for non-left main bifurcation lesions were recruited into EBC TWO. Inclusion criteria required a side branch diameter ≥2.5 mm and side branch lesion length >5 mm. Five-year follow-up was completed for 197 patients. The primary endpoint was the composite of all-cause mortality, myocardial infarction, or target vessel revascularisation. RESULTS: The mean side branch stent diameter was 2.7±0.3 mm and mean side branch lesion length was 10.3±7.2 mm. At 5-year follow-up, the primary endpoint occurred in 18.4% of provisional and 23.7% of systematic culotte patients (hazard ratio [HR] 0.75, 95% confidence interval [CI]: 0.41-1.38). No significant differences were identified individually for all-cause mortality (7.8% vs 7.2%, HR 1.11, 95% CI: 0.40-3.05), myocardial infarction (8.7% vs 13.4%, HR 0.64, 95% CI: 0.27-1.50) or target vessel revascularisation (6.8% vs 9.3%, HR 1.12, 95% CI: 0.37-3.34). Stent thrombosis rates were also similar (1.9% vs 3.1%, HR 0.63, 95% CI: 0.11-3.75). There was no significant interaction between the extent of side branch disease and the primary outcome (p=0.34). CONCLUSIONS: In large non-left main true bifurcation lesions, the use of a systematic culotte strategy showed no benefit over provisional stenting for the composite outcome of all-cause mortality, myocardial infarction, or target vessel revascularisation at 5 years. The stepwise provisional approach may be considered preferable for the majority of true coronary bifurcation lesions. CLINICALTRIALS: gov: NCT01560455.

14.
Circ Cardiovasc Interv ; 16(11): e013296, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988436

RESUMEN

BACKGROUND: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI. METHODS: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed. Bench-top analysis of Redo TAVI was performed using different contemporary THVs. Procedural and outcome data were obtained from 10 patients who had undergone Redo TAVI for Lotus bioprosthetic valve failure in 5 centers. Recommendations for performing Redo TAVI in Lotus are made, based on these findings. RESULTS: The Lotus leaflets extend from the frame inflow, with a Neoskirt of only 13 mm, hence a low risk of coronary obstruction during Redo TAVI. The Lotus frame posts prevent full apposition of the Redo prosthesis in the upper part of the frame, while implantation of the Redo THV above the Lotus inflow leads to inadequate apposition of the Lotus leaflets. Inflow-to-inflow positioning is therefore recommended for effective sealing and leaflet pinning. The Lotus locking mechanism prevents overexpansion of the frame, limiting Redo THV oversizing. Redo TAVI was favorable with SAPIEN 3, Evolut, and Navitor THVs on bench-top analysis but not with ACURATE Neo 2 due to the upper crowns and short stent preventing inflow-to-inflow deployment. Case review demonstrated satisfactory outcomes in 10 patients treated with Evolut (n=6), SAPIEN 3 (n=3), and Portico (n=1) valves, with no mortality, major morbidity, or coronary obstruction. Three patients had residual mean gradient ≥20 mm Hg, including 2 of 3 SAPIEN cases. Guidance on procedural planning, valve choice, sizing, and positioning is provided. CONCLUSIONS: Redo TAVI in Lotus requires an understanding of unique design characteristics, and adherence to key procedural recommendations, but can be safely and effectively performed with most contemporary valve types.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
15.
J Invasive Cardiol ; 35(7): E355-E364, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37769621

RESUMEN

BACKGROUND: Percutaneous transaxillary access is used as an alternative to the transfemoral approach for transcatheter aortic valve implantation in patients with severe peripheral vascular disease. The left transaxillary approach is usually preferred due to ease of valve alignment with the aortic annulus. Some patients have anatomical and physiological factors which preclude this approach. Moreover, most catheterization lab layouts make left-sided approaches to the heart awkward for imaging, visualization, procedural ease, and radiation protection. AIMS: The authors describe novel adaptations to allow successful right transaxillary access for implantation of the transcatheter heart valve using the Edwards Sapien 3 system (Edwards Lifesciences). METHODS: We searched our local structural heart database for all patients who underwent transcatheter aortic valve implantation via axillary access, from January 2021 to January 2022. Patients with left axillary access were excluded. RESULTS: We report 6 percutaneous right transaxillary cases performed in the last year using steps which allow smooth delivery of the SAPIEN 3 Ultra valve down the greater curvature of the aorta and providing co-axial alignment of the valve. Only one patient had a vascular complication with arterial dissection at the closure point managed with 8 mm x 37 mm Bentley uncovered stent at the access site. CONCLUSION: With the modifications described in our article, the right transaxillary approach has now become our preferred secondary access route for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Diseño de Prótesis
16.
JACC Cardiovasc Interv ; 16(17): 2065-2082, 2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37704294

RESUMEN

Knowledge in the field of bifurcation lesions and chronic total occlusions (CTOs) has progressively improved over the past 20 years. Therefore, the European Bifurcation Club and the EuroCTO Club have decided to write a joint consensus statement to share general knowledge and practical approaches in this complex field. When percutaneously treating CTOs, bifurcation lesions with relevant side branches (SBs) are found in approximately one-third of cases (35% at the proximal cap, 38% at the distal cap, and 27% within the CTO body). Occlusion of a relevant SB is not rare and has been shown to be associated with procedural complications and adverse outcomes. Simple bifurcation rules are very useful to prevent SB occlusion, and provisional SB stenting is the recommended approach in the majority of cases: protect the SB as soon as possible by wiring it, respect the fractal anatomy of the bifurcation by using the 3-diameter rule, and avoid using dissection and re-entry techniques. A systematic 2-stent approach can be used if needed or sometimes to connect both branches of the bifurcation. The retrograde approach can be very useful to save a relevant SB, especially in the case of a bifurcation at the distal cap or within the CTO body. Intravascular ultrasound is also a very important tool to address the difficulties with bifurcations at the proximal or distal cap and sometimes also within the CTO segment. Double-lumen microcatheters and angulated microcatheters are crucial tools to resolve access difficulties to the SB or the main branch.


Asunto(s)
Disección , Enfermedades Vasculares , Humanos , Resultado del Tratamiento , Consenso , Stents
17.
Interv Cardiol ; 18: e13, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37398870

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an effective and established treatment for symptomatic aortic stenosis. However, there is a lack of consensus concerning the need for peri- and post-procedural anti-thrombotic medication. Contemporary guidelines recommend that anti-thrombotic therapy is balanced against a patient's bleeding risk following TAVI, but do not fully consider the evolving evidence base. The purpose of the Delphi panel recommendations presented here is to provide a consensus elicited from a panel of experts who regularly prescribe anti-thrombotic therapy post-TAVI. The goal was to address evidence gaps across four key topics: anti-thrombotic therapy (anti-platelet and/or anti-coagulant) in TAVI patients in sinus rhythm; anti-thrombotic therapy in TAVI patients with AF; direct oral anti-coagulants versus vitamin K antagonists; and the need for UK/Ireland specific guidance. This consensus statement aims to inform clinical decision-making by providing a concise, evidence-based summary of best practice for prescribing anti-thrombotic therapies following TAVI and highlights areas where further research is needed.

18.
Catheter Cardiovasc Interv ; 102(3): 430-439, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37464969

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) for bifurcation lesions can be technically challenging and is associated with higher risk. There is little data on sex-based differences in strategy and outcomes in bifurcation PCI. AIMS: We sought to assess whether differences exist between women and men in the treatment and outcomes of bifurcation PCI. METHODS: We collected data on 4006 patients undergoing bifurcation PCI, from the e-ULTIMASTER study, a prospective, multicentre study enrolling patients from 2014 to 2018. We divided the bifurcation cohort according to sex, with 1-year follow-up of outcomes (target lesion failure [TLF], target vessel failure [TVF], and patient-oriented composite endpoint [POCE]). FINDINGS: Women were older (69.2 ± 10.9 years vs. 64.4 ± 11.0 years), with a greater burden of cardiovascular comorbidities. For true and non-true bifurcation lesions, women and men were equally likely to undergo a single stent approach (true: 63.2% vs. 63.6%, p = 0.79, non-true: 95.4% vs. 94.3%, p = 0.32), with similar rates of final kissing balloon (FKB) (37.2% vs. 35.5%, p = 0.36) and proximal optimization (POT) (34.4% vs. 34.2%, p = 0.93) in cases where two stents were used. Lastly, after propensity score matching, there was no difference between women and men in the incidence of the composite endpoints of TLF (5.5% vs. 5.2%, RR 1.05 [95% CI 0.77-1.44], p = 0.75), TVF (6.2% vs. 6.3%, RR 0.99 [95% CI 0.74-1.32], p = 0.96), and POCE (9.9% vs. 9.5%, RR 1.05 [95% CI 0.83-1.31], p = 0.70). CONCLUSION: In this contemporary, real-world study of bifurcation PCI, we report no difference in stent strategy between women and men, with similar outcomes at 1-year.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Masculino , Humanos , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Stents , Sistema de Registros , Angiografía Coronaria
19.
EuroIntervention ; 19(7): 571-579, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37482940

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) for chronic total coronary occlusions (CTO) improves clinical symptoms and quality of life. The longer-term safety of PCI compared to optimal medical therapy (OMT) remains uncertain. AIMS: We sought to evaluate the long-term safety of PCI for CTO in a randomised trial as compared to OMT. METHODS: A total of 396 patients with a symptomatic CTO were enrolled into a randomised, multicentre clinical trial comparing PCI and OMT. Half of the patients had a single CTO; the others had multivessel disease. Non-CTO lesions were treated prior to randomisation (2:1 ratio). During follow-up, crossover from OMT to PCI occurred in 7.3% (1 year) and 17.5% (3 years) of patients. RESULTS: At 3 years, the incidence of cardiovascular death or nonfatal myocardial infarction was not significantly different between the groups (OMT 3.7% vs PCI 6.2%; p=0.29). By per-protocol analysis, the difference remained non-significant (OMT 5.7% vs PCI 4.7%; p=0.67). Overall, major adverse cardiovascular events (MACE) were more frequent with OMT (OMT 21.2% vs PCI 11.2%), largely because of ischaemia-driven revascularisation. The rates of stroke or hospitalisation for bleeding were not different between the groups. CONCLUSIONS: At 3 years there was no difference in the rate of cardiovascular death or myocardial infarction between PCI or OMT among patients with a remaining single coronary CTO. The MACE rate was higher in the OMT group due largely to ischaemia-driven revascularisation. CTO PCI appears to be a safe option for patients with a single remaining significant coronary CTO. CinicalTrials.gov: NCT01760083.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Calidad de Vida , Infarto del Miocardio/terapia , Enfermedad Crónica , Factores de Riesgo
20.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...