Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 20(21)2020 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-33158171

RESUMEN

Current testing methods are capable of measuring strain near the surface on structural parts, for example by using strain gauges. However, stress peaks often occur within the material and can only be approximated. An alternative strain measurement incorporates fibre-optical strain sensors (Fiber Bragg Gratings, FBG) which are able to determine strains within the material. The principle has already been verified by using embedded FBGs in tensile specimens. The transition area between fibre and aluminium, however, is not yet properly investigated. Therefore, strains in tensile specimens containing FBGs were measured by neutron diffraction in gauge volumes of two different sizes around the Bragg grating. As a result, it is possible to identify and decouple elastic and plastic strains affecting the FBGs and to transfer the findings into a fully descriptive FE-model of the strain transition area.We thus accomplished closing the gap between the external load and internal straining obtained from cast-in FBG and generating valuable information about the mechanisms within the strain transition area.It was found that the porosity within the casting has a significant impact on the stiffness of the tensile specimen, the generation of excess microscopic tensions and thus the formation of permanent plastic strains, which are well recognized by the FBG. The knowledge that FBG as internal strain sensors function just as well as common external strain sensors will now allow for the application of FBG in actual structural parts and measurements under real load conditions. In the future, applications for long-term monitoring of cast parts will also be enabled and are currently under development.

2.
Eur J Orthod ; 39(3): 310-319, 2017 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-27365182

RESUMEN

Objective: The purpose of this study was to estimate the feasibility and accuracy of mesio-distal width measurements with magnetic resonance imaging (MRI) in comparison to conventional 3D imaging techniques [multi-slice CT (MSCT), cone-beam CT (CBCT), and µCT]. The measured values of the tooth widths were compared to each other to estimate the amount of radiation necessary to enable orthodontic diagnostics. Material and Methods: Two pig skulls were measured with MSCT, CBCT, µCT, and MRI. Three different judges were asked to determine the mesio-distal tooth width of 14 teeth in 2D tomographic images and in 3D segmented images via a virtual ruler in every imaging dataset. Results: Approximately 19% (27/140) of all test points in 2D tomographic slice images and 12% (17/140) of the test points in 3D segmented images showed a significant difference (P ≤ 0.05). The largest significant difference was 1.6mm (P < 0.001). There were fewer significant differences in the measurement of the tooth germs than in erupted teeth. Conclusions: Measurement of tooth width by MRI seems to be clinically equivalent to the conventional techniques (CBCT and MSCT). Tooth germs are better illustrated than erupted teeth on MRI. Three-dimensional segmented images offer only a slight advantage over 2D tomographic slice images. MRI, which avoids radiation, is particularly appealing in adolescents if these data can be corroborated in further studies.


Asunto(s)
Odontometría/métodos , Diente/anatomía & histología , Puntos Anatómicos de Referencia , Animales , Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Maxilares/anatomía & histología , Maxilares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Variaciones Dependientes del Observador , Dosis de Radiación , Reproducibilidad de los Resultados , Sus scrofa , Tomografía Computarizada por Rayos X/métodos , Diente/diagnóstico por imagen , Germen Dentario/anatomía & histología , Germen Dentario/diagnóstico por imagen
3.
J Orofac Orthop ; 77(4): 251-61, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27098643

RESUMEN

OBJECTIVES: To examine the relative usefulness and suitability of magnetic resonance imaging (MRI) in daily clinical practice as compared to various technologies of computed tomography (CT) in addressing questions of orthodontic interest. METHODS: Three blinded raters evaluated 2D slices and 3D reconstructions created from scans of two pig heads. Five imaging modalities were used, including three CT technologies-multislice (MSCT), cone-beam CT (CBCT), and industrial (µCT)-and two MRI protocols with different scan durations. Defined orthodontic parameters were rated one by one on the 2D slices and the 3D reconstructions, followed by final overall ratings for each modality. A mixed linear model was used for statistical analysis. RESULTS: Based on the 2D slices, the parameter of visualizing tooth-germ topography did not yield any significantly different ratings for MRI versus any of the CT scans. While some ratings for the other parameters did involve significant differences, how these should be interpreted depends greatly on the relevance of each parameter. Based on the 3D reconstructions, the only significant difference between technologies was noted for the parameter of visualizing root-surface morphology. Based on the final overall ratings, the imaging performance of the standard MRI protocol was noninferior to the performance of the three CT technologies. CONCLUSIONS: On comparing the imaging performance of MRI and CT scans, it becomes clear that MRI has a huge potential for applications in daily clinical practice. Given its additional benefits of a good contrast ratio and complete absence of ionizing radiation, further studies are needed to explore this clinical potential in greater detail.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Maxilares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada Multidetector/métodos , Radiografía Dental/métodos , Diente/diagnóstico por imagen , Animales , Industrias/métodos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego , Porcinos , Evaluación de la Tecnología Biomédica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...