Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
JBMR Plus ; 8(5): ziae002, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38596507

RESUMEN

Postfracture survival rates provide prognostic information but are rarely reported along with other mortality outcomes in adults aged ≥50 yr. The timing of survival change following a fracture also needs to be further elucidated. This population-based, matched-cohort, retrospective database study examined 98 474 patients (73% women) aged ≥66 yr with an index fracture occurring at an osteoporotic site (hip, clinical vertebral, proximal non-hip non-vertebral [pNHNV], and distal non-hip non-vertebral [dNHNV]) from 2011 to 2015, who were matched (1:1) to nonfracture individuals based on sex, age, and comorbidities. All-cause 1- and 5-yr overall survival and relative survival ratios (RSRs) were assessed, and time trends in survival changes were characterized starting immediately after a fracture. In both sexes, overall survival was markedly decreased over 6 yr of follow-up after hip, vertebral, and pNHNV fractures, and as expected, worse survival rates were observed in older patients and males. The lowest 5-yr RSRs were observed after hip fractures in males (66-85 yr, 51.9%-63.9%; ≥86 yr, 34.5%), followed by vertebral fractures in males (66-85 yr, 53.2%-69.4%; ≥86 yr, 35.5%), and hip fractures in females (66-85 yr, 69.8%-79.0%; ≥86 yr, 52.8%). Although RSRs did not decrease as markedly after dNHNV fractures in younger patients, relatively low 5-yr RSRs were observed in females (75.9%) and males (69.5%) aged ≥86 yr. The greatest reduction in survival occurred within the initial month after hip, vertebral, and pNHNV fractures, indicating a high relative impact of short-term factors, with survival-reduction effects persisting over time. Therefore, the most critical period for implementing interventions aimed at improving post-fracture prognosis appears to be immediately after a fracture; however, considering the immediate need for introducing such interventions, primary fracture prevention is also crucial to prevent the occurrence of the initial fracture in high-risk patients.

2.
Adv Healthc Mater ; : e2304186, 2024 Apr 27.
Artículo en Catalán | MEDLINE | ID: mdl-38676697

RESUMEN

In viral infections, natural killer (NK) cells exhibit anti-viral activity by inducing apoptosis in infected host cells and impeding viral replication through heightened cytokine release. Extracellular vesicles derived from NK cells (NK-EVs) also contain the membrane composition, homing capabilities, and cargo that enable anti-viral activity. These characteristics, and their biocompatibility and low immunogenicity, give NK-EVs the potential to be a viable therapeutic platform. This study characterizes the size, EV-specific protein expression, cell internalization, biocompatibility, and anti-viral miRNA cargo to evaluate the anti-viral properties of NK-EVs. After 48 h of NK-EV incubation in inflamed A549 lung epithelial cells, or conditions that mimic lung viral infections such as during COVID-19, cells treated with NK-EVs exhibit upregulated anti-viral miRNA cargo (miR-27a, miR-27b, miR-369-3p, miR-491-5p) compared to the non-treated controls and cells treated with control EVs derived from lung epithelial cells. Additionally, NK-EVs effectively reduce expression of viral RNA and pro-inflammatory cytokine (TNF-α, IL-8) levels in SARS-CoV-2 infected Vero E6 kidney epithelial cells and in infected mice without causing tissue damage while significantly decreasing pro-inflammatory cytokine compared to non-treated controls. Herein, this work elucidates the potential of NK-EVs as safe, anti-viral nanomaterials, offering a promising alternative to conventional NK cell and anti-viral therapies.

3.
Int J Mol Sci ; 25(6)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38542115

RESUMEN

Cluster of differentiation 44 (CD44), a cell surface adhesion molecule overexpressed in cancer stem cells, has been implicated in chemoresistance. This scoping review, following PRISMA-ScR guidelines, systematically identified and evaluated clinical studies on the impact of CD44 expression on chemotherapy treatment outcomes across various cancer types. The search encompassed PubMed (1985-2023) and SCOPUS (1936-2023) databases, yielding a total of 12,659 articles, of which 40 met the inclusion criteria and were included in the qualitative synthesis using a predefined data extraction table. Data collected included the cancer type, sample size, interventions, control, treatment outcome, study type, expression of CD44 variants and isoforms, and effect of CD44 on chemotherapy outcome. Most of the studies demonstrated an association between increased CD44 expression and negative chemotherapeutic outcomes such as shorter overall survival, increased tumor recurrence, and resistance to chemotherapy, indicating a potential role of CD44 upregulation in chemoresistance in cancer patients. However, a subset of studies also reported non-significant relationships or conflicting results. In summary, this scoping review highlighted the breadth of the available literature investigating the clinical association between CD44 and chemotherapeutic outcomes. Further research is required to elucidate this relationship to aid clinicians in managing CD44-positive cancer patients.


Asunto(s)
Resistencia a Antineoplásicos , Receptores de Hialuranos , Humanos , Receptores de Hialuranos/genética , Receptores de Hialuranos/metabolismo , Resultado del Tratamiento
4.
SLAS Technol ; 28(6): 384-392, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37925157

RESUMEN

Cholera is a waterborne disease caused by Vibrio cholerae bacteria generally transmitted through contaminated food or water sources. Although it has been eradicated in most Western countries, cholera continues to be a highly transmitted and lethal disease in several African and Southeast Asian countries. Unfortunately, current diagnostic methods for cholera have challenges including high cost or delayed diagnoses that can lead to increased disease transmission during pandemics, while current treatments such as therapeutic drugs and vaccines have limited efficacy against drug-resistant serogroups of Vibrio cholerae. As such, new solutions that can treat cholera in an efficient manner that avoids Vibrio cholerae's adaptive immunity are needed. Nanoparticles (NPs) are a suitable platform for enhancing current theranostic tools because of their biocompatibility and ability to improve drug circulation and targeting. Nanoparticle surfaces can also be modified with various protein receptors targeting cholera toxins produced by Vibrio cholerae. This review will address recent developments in diagnostics, therapeutics, and prevention against cholera particularly focusing on the use of metal-based nanoparticles and organic nanoparticles. We will then discuss future directions regarding nanoparticle research for cholera.


Asunto(s)
Cólera , Nanopartículas del Metal , Vibrio cholerae , Humanos , Cólera/diagnóstico , Cólera/prevención & control
5.
Spine (Phila Pa 1976) ; 48(4): E46-E53, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36130044

RESUMEN

STUDY DESIGN: Preclinical biomechanical study of topology optimization versus standard ring design for bioresorbable poly-ε-caprolactone (PCL) cervical spine fusion cages delivering bone morphogenetic protein-2 (BMP-2) using a porcine model. OBJECTIVE: The aim was to evaluate range of motion (ROM) and bone fusion, as a function of topology optimization and BMP-2 delivery method. SUMMARY OF BACKGROUND DATA: 3D printing technology enables fabrication of topology-optimized cages using bioresorbable materials, offering several advantages including customization, and lower stiffness. Delivery of BMP-2 using topology optimization may enhance the quality of fusion. METHODS: Twenty-two 6-month-old pigs underwent anterior cervical discectomy fusion at one level using 3D printed PCL cages. Experimental groups (N=6 each) included: Group 1: ring design with surface adsorbed BMP-2, Group 2: topology-optimized rectangular design with surface adsorbed BMP-2, and Group 3: ring design with BMP-2 delivery via collagen sponge. Additional specimens, two of each design, were implanted without BMP-2, as controls. Complete cervical segments were harvested six months postoperatively. Nanocomputed tomography was performed to assess complete bony bridging. Pure moment biomechanical testing was conducted in all three planes, separately. Continuous 3D motions were recorded and analyzed. RESULTS: Three subjects suffered early surgical complications and were not evaluated. Overall, ROM for experimental specimens, regardless of design or BMP-2 delivery method, was comparable, with no clinically significant differences among groups. Among experimental specimens at the level of the fusion, ROM was <1.0° in flexion and extension, indicative of fusion, based on clinically applied criteria for fusion of <2 to 4°. Despite the measured biomechanical stability, using computed tomography evaluation, complete bony bridging was observed in 40% of the specimens in Group 1, 50% of Group 2, 100% of Group 3, and none of the control specimens. CONCLUSION: A topology-optimized PCL cage with BMP-2 is capable of resulting in an intervertebral fusion, similar to a conventional ring-based design of the same bioresorbable material.


Asunto(s)
Vértebras Cervicales , Fusión Vertebral , Animales , Porcinos , Vértebras Cervicales/cirugía , Implantes Absorbibles , Cuello , Tomografía Computarizada por Rayos X , Impresión Tridimensional , Fusión Vertebral/métodos , Fenómenos Biomecánicos , Rango del Movimiento Articular
6.
J Bone Joint Surg Am ; 104(9): 796-804, 2022 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-35167500

RESUMEN

BACKGROUND: Metal debris and corrosion products generated from the taper junctions of modular joint replacements have been recognized as contributors to failure. Therefore, understanding the factors associated with increased taper wear and corrosion is fundamental to improving implant performance. METHODS: A cohort of 85 large-diameter metal-on-metal heads and cups retrieved at revision surgery, after 10 to 96 months of service, was evaluated. First, metrology was conducted to quantify head taper material loss and implant articular surface wear. Then, joint frictional moments for each retrieved head-and-cup pair were measured during 10 cycles of simulated physiological gait in a biomechanical model. Taper material loss was evaluated for correlations with frictional moments, articular wear, head diameter, head-cup clearance, and time in vivo. RESULTS: Peak resultant frictional moments ranged from 9.1 to 26.3 Nm, averaging 17.3 ± 2.7 Nm. Fretting and corrosion damage during in vivo service resulted in material loss from the head tapers ranging between 0.04 and 25.57 mm3, compared with combined head and cup articular wear of 0.80 to 351.75 mm3 in this cohort. Taper material loss was not correlated with higher frictional moments (R = -0.20 to 0.11, p = 0.07 to 0.81). Higher frictional moments from axial rotation were correlated with higher head and cup wear (R = 0.33, p < 0.01). The correlation between taper material loss and head diameter was weak and did not reach statistical significance (R = 0.20, p = 0.07). Taper material loss was not correlated with nominal head-cup clearance (R = 0.06, p = 0.6). Finally, taper material loss increased significantly over time (R = 0.34, p < 0.01). CONCLUSIONS: Despite serious concerns regarding trunnionosis, volumes of head taper wear were generally lower than those of articular surface wear. There was no statistical correlation between taper wear and frictional moments. Therefore, the results suggest that high friction in metal-on-metal implants does not contribute to higher material loss at the head taper, despite high bending moments. CLINICAL RELEVANCE: The amount of metal debris and corrosion products from taper junctions of the joint arthroplasties, widely recognized as an insidious cause of failure, was not correlated with joint frictional moments. Multiple factors affect taper wear: implant design, material, size, surface finish, and patient weight and activity level. However, in the present cohort, high friction of metal-on-metal total hip replacements likely did not contribute to increased volume of material loss at taper interfaces, despite increased moments at the locations of taper material loss.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Corrosión , Fricción , Articulación de la Cadera/cirugía , Humanos , Metales , Diseño de Prótesis , Falla de Prótesis
7.
J Orthop Res ; 40(8): 1943-1952, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34694639

RESUMEN

Femoral bone quality is a major risk factor of periprosthetic fracture after total hip arthroplasty (THA), which has mortality similar to native hip fractures but higher short-term morbidity. The goal of this study was to quantify cortical strains at the site of expected Vancouver Type-B periprosthetic fracture as a function of bone mineral density, femoral stem material, and fixation method using a series of 29 autopsy-retrieved, clinically asymptomatic hip joints with THA. Periprosthetic bone mineral content and density was assessed using dual-energy X-ray absorptiometry by Gruen Zone. Specimens then underwent combined cyclic axial and torsional loading, increasing incrementally from 100 N and ±1 Nm to peaks of 700 N and ±5 Nm. All specimens experienced significantly higher strains on the lateral surface than on the anterior surface, indicating that the bending loads in the frontal plane, rather than axial/torsional loads, had the predominant effect. Multiple significant relationships (p = 0.04, p = 0.02) were found between predicted periprosthetic strains calculated from radiographic measurements and observed principal strains. Though THA in the present study were in successful clinical service, the produced results indicated that some femurs with rigid cemented or noncemented implants were potentially at high risk for Vancouver Type-B fractures, which may be predicted radiographically.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Absorciometría de Fotón/efectos adversos , Absorciometría de Fotón/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Densidad Ósea , Fracturas del Fémur/cirugía , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Fracturas Periprotésicas/etiología
8.
J Orthop Res ; 40(5): 1053-1064, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34251706

RESUMEN

Numerous animal and human studies have demonstrated the benefit of controlled interfragmentary motion on fracture healing. In this study, we quantified interfragmentary motion and load transfer in tibial fractures fixed using a novel intramedullary nail (IMN) that allows controlled axial motion. Fifty composite tibias with various fracture patterns were utilized. For all test conditions, two interlocking screws were used to fix the nail in the proximal metaphysis, and two interlocking screws through the distal metaphysis. The nail allowed either no motion (static mode) or 1 mm (dynamic mode) of cyclic axial motion between the two fracture fragments for every fracture pattern tested. As expected, strain shielding was more prominent under static nail conditions. In contrast, specimens tested under dynamic nail conditions transferred axial load between the fracture fragments such that strains near the fracture site were generally similar to those measured on an intact tibia. Maximum shear strains proximal to the fracture were significantly lower in specimens with oblique or butterfly fracture patterns (p < 0.01) compared to intact specimens. This decrease in shear strain indicates that strain shielding effects were likely present due to the implant. However, strain shielding appeared to be reduced in tensile and compressive principal strains. In summary, the novel IMN allowed controlled axial motion between the fragments in a variety of common diaphyseal tibial fracture patterns. Clinical Significance: The present in vitro biomechanical study investigated a novel intramedullary nail capable of controlled axial interfragmentary motion which may potentially enhance fracture healing.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de la Tibia , Fenómenos Biomecánicos , Clavos Ortopédicos , Humanos , Tibia/cirugía , Fracturas de la Tibia/cirugía
9.
Foot Ankle Surg ; 27(3): 316-320, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32651082

RESUMEN

INTRODUCTION: Poor long-term outcomes continue to hinder the universal adoption of total ankle replacements (TAR) for end stage arthritis. In the present study, polyethylene inserts of TARs retrieved at revision surgery were analyzed for burnishing, scratching, mechanical damage, pitting, and embedded particles. METHODS: Fourteen retrieved polyethylene inserts from a fixed bearing total ankle replacement design currently in clinical use were analyzed. Duration of time in vivo was between 11.5 months and 120.1 months. Three investigators independently graded each articular surface in quadrants for five features of damage: burnishing, scratching, mechanical damage, pitting, and embedded particles. RESULTS: No correlation was found for burnishing between the anterior and posterior aspects (p = 0.47); however, scratching and pitting were significantly higher on the posterior aspect compared to the anterior aspect (p < 0.03). There was a high correlation between burnishing and in vivo duration of the implant (anterior: R = 0.67, p = 0.01, posterior: R = 0.68, p = 0.01). CONCLUSION: The higher concentration of posterior damage on these polyethylene inserts suggested that prosthesis-related (design) or surgeon-related (technique) factors might restrict the articulation of the implant. The resulting higher stresses in the posterior articular surfaces may have contributed to the failure of retrieved implants Keywords: Retrieval, Polyethylene Damage, Total Ankle Replacement.


Asunto(s)
Artritis/cirugía , Artroplastia de Reemplazo de Tobillo/efectos adversos , Artroplastia de Reemplazo de Tobillo/métodos , Prótesis Articulares/efectos adversos , Polietileno/efectos adversos , Diseño de Prótesis/efectos adversos , Diseño de Prótesis/métodos , Humanos , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Orthop Res ; 39(4): 797-805, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33251621

RESUMEN

The International Standard Organization, ISO 22622, specifies two options for joint wear simulator evaluation of total ankle replacements (TARs): load-controlled and displacement-controlled. In the present study, the load-controlled testing parameters were applied to cadaveric specimens to quantify and compare the observed sagittal translations and axial rotations to those specified under the displacement-controlled option. Twelve cadaveric specimens were stripped of extraneous tissues, keeping surrounding ankle ligaments. A halo was used to produce plantarflexion and dorsiflexion of the talus through two screws, while a baseplate resisted axial loads. The axial force and torque were applied to the tibia and fibula under force and torque feedback control. An anterior-posterior force was applied to the tibia. Plantarflexion-dorsiflexion were applied using rotation control. To protect the cadaveric specimens, loads were applied at 50% of the specified load profile while plantarflexion-dorsiflexion rotation was applied as specified. There was variation among specimens in magnitudes of anterior-posterior displacement with peaks ranging from 3.3 mm posteriorly to 3.0 mm anteriorly. Likewise, there was variation among specimens in magnitude of axial rotation, with peaks ranging from 11° external rotation to 4.5° internal rotation. However, the mean magnitudes of AP displacement and axial rotation did not exceed those specified by ISO 22622.


Asunto(s)
Artroplastia de Reemplazo de Tobillo/instrumentación , Ensayo de Materiales , Diseño de Prótesis , Astrágalo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Artroplastia de Reemplazo de Tobillo/métodos , Tornillos Óseos , Cadáver , Diseño de Equipo , Femenino , Humanos , Ligamentos Articulares/cirugía , Masculino , Persona de Mediana Edad , Falla de Prótesis , Rotación , Estrés Mecánico , Torque , Soporte de Peso
11.
JBJS Rev ; 8(3): e0091, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32149932

RESUMEN

BACKGROUND: Numerous studies have reported the use of laboratory multistation joint simulators to successfully predict wear performance and functionality of hip and knee replacements. In contrast, few studies in the peer-reviewed literature have used joint simulation to quantify the wear performance and functionality of ankle replacements. We performed a systematic review of the literature on joint simulator studies that quantified polyethylene wear in total ankle arthroplasty. In addition to the quantified wear results, the load and motion parameters were identified and compared among the studies. METHODS: A search was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to identify articles reporting total ankle replacement polyethylene wear using joint simulators. RESULTS: Nine studies that used joint simulators and 1 study that used a computer simulation were found. Although all studies used physiological multidirectional motions (i.e., internal/external rotation, plantar flexion/dorsiflexion, anterior/posterior translation), there was large variability among the studies in the magnitudes of these motions. Among these studies, mean non-cross-linked polyethylene wear ranged from 3.3 ± 0.4 to 25.8 ± 3.1 mm per million cycles. In contrast, mean highly cross-linked polyethylene wear ranged from 2.1 ± 0.3 to 3.3 ± 0.4 mm per million cycles. The wide distribution in wear rates was attributable to the highly inconsistent kinematic parameters and loads applied as well as differences in implant design and materials. CONCLUSIONS: There is a severe lack of clinically applicable data on wear performance of total ankle replacements in the peer-reviewed literature. No universal set of kinematic load parameters has been established. Furthermore, only 2 of the published studies have validated their findings using independently derived data, such as retrieval analysis. These shortcomings make it difficult to compare findings as a function of design parameters and materials, or to draw clinically relevant conclusions from these simulations. More work is required to enhance the predictive capability of in vitro simulations of total ankle replacements. CLINICAL RELEVANCE: The results of joint wear simulator studies may not accurately represent in vivo wear of total ankle replacements. Joint simulator studies should establish that they are accurately replicating in vivo wear, thus enabling use of their predictive capabilities for new materials and designs.


Asunto(s)
Artroplastia de Reemplazo de Tobillo/instrumentación , Prótesis Articulares , Estudios de Evaluación como Asunto , Humanos
12.
Spine Deform ; 8(4): 577-584, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32026440

RESUMEN

STUDY DESIGN: Biomechanical simulation of DVR and pure-moment testing on thoracic spines. OBJECTIVES: Characterize load-deformation response of thoracic spines under DVR maneuvers until failure, and compare to pure-moment testing of same spines. Despite reports of surgical complications, few studies exist on increase in ROM under DVR torque. Biomechanical models predicting increases from surgical releases have consistently used "pure-moments", a standard established for non-destructive measurement of ROM. Yet, DVR torque is not accurately modeled using pure moments and, moreover, magnitudes of torque applied during DVR maneuvers may be substantially higher than pure-moment testing. METHODS: Cadaveric thoracic spines (N = 11) were imaged, then prepared. Polyaxial pedicle screws were implanted at T7-T10 after surgical releases. Bilateral facetectomies and Ponte osteotomies were completed at T10-T11. A custom apparatus, mounted into an 8-dof MTS load frame, was used to attach to pedicle screws, allowing simulation of surgical DVR maneuvers. Motions of vertebrae were measured using optical motion tracking. Torque was increased until rupture of the T10-T11 disc or fracture at the pedicle screw sites at any level. The torque-rotation behavior was compared to its behavior under pure-moment testing performed prior to the DVR maneuver. RESULTS: Under DVR maneuvers, failure of the T10-T11 discs accompanied in most cases by pedicle screw loosening, occurred at 13.7-54.7 Nm torque, increasing axial rotation by 1.4°-8.9°. In contrast, pure-moment testing (4 Nm) increased axial rotation by only 0.0°-0.9°. CONCLUSIONS: DVR resulted in substantially greater correction potential increases compared to pure-moment testing even at the same torque. These results suggest increased flexibility obtained by osteotomies and facetectomies is underestimated using pure-moment testing, misrepresenting clinical expectations. The present study is an important and necessary step toward the establishment of a more accurate and ultimately surgically applied model. LEVEL OF EVIDENCE: III.


Asunto(s)
Escoliosis/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Vértebras Torácicas/cirugía , Torque , Fenómenos Biomecánicos , Cadáver , Humanos , Osteotomía , Rango del Movimiento Articular , Rotación , Escoliosis/fisiopatología , Vértebras Torácicas/fisiopatología
13.
Foot Ankle Surg ; 26(1): 14-18, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30600154

RESUMEN

In recent years, total ankle replacements have gained increasing popularity as an alternative to fusion. Preclinical testing of TARs requires reliable in vitro models which, in turn, need thorough knowledge of the kinematics of the tibiotalar joint. Surprisingly few studies have been published to simulate the in vivo kinematics of the tibiotalar joint. Among these studies, there is a wide range of methods and magnitudes of applied loads. The purpose of the present review was to summarize the applied loads, positions that were tested during static simulations, and ranges of motion simulated that have been used in human cadaveric models of the tibiotalar joint. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, PubMed and Google Scholar were searched for studies pertaining to cadaveric tibiotalar joint kinematics. Our search yielded 12 appropriate articles that were included in the systematic review. While it is well known that loads at the tibiotalar joint are frequently as high as 5 times bodyweight [1], these studies reported applied loads varying from 200N-750N, below average bodyweight. Three studies used dynamic loading of custom apparatuses to drive cadaver limbs along predetermined paths to simulate gait. Conversely, the other nine studies applied static loads (∼300N), performed at discreet points during the stance phase, considerably lower than physiological conditions. The present systematic review calls for an urgent need to establish a consensus for preclinical evaluation of TARs for biomechanical function.


Asunto(s)
Articulación del Tobillo/cirugía , Artroplastia de Reemplazo de Tobillo/métodos , Marcha/fisiología , Articulación del Tobillo/fisiopatología , Fenómenos Biomecánicos , Cadáver , Humanos
14.
Foot Ankle Surg ; 25(1): 71-78, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29409256

RESUMEN

BACKGROUND: To obtain adequate fixation in treating Lisfranc soft tissue injuries, the joint is commonly stabilized using multiple transarticular screws; however iatrogenic injury is a concern. Alternatively, two parallel, longitudinally placed plates, can be used to stabilize the 1st and 2nd tarsometatarsal joints; however this may not provide adequate stability along the Lisfranc ligament. Several biomechanical studies have compared earlier methods of fixation using plates to the standard transarticular screw fixation method, highlighting the potential issue of transverse stability using plates. A novel dorsal plate is introduced, intended to provide transverse and longitudinal stability, without injury to the articular cartilage. METHODS: A biomechanical cadaver model was developed to compare the fixation stability of a novel Lisfranc plate to that of traditional fixation, using transarticular screws. Thirteen pairs of cadaveric specimens were tested intact, after a simulated Lisfranc injury, and then following implant fixation, using one method of fixation randomly assigned, on either side of each pair. Optical motion tracking was used to measure the motion between each of the following four bones: 1st metatarsal, 2nd metatarsal, 1st cuneiform, and 2nd cuneiform. Testing included both cyclic abduction loading and cyclic axial loading. RESULTS: Both the Lisfranc plate and screw fixation method provided stability such that the average 3D motions across the Lisfranc joint (between 2nd metatarsal and 1st cuneiform), were between 0.2 and 0.4mm under cyclic abduction loading, and between 0.4 and 0.5mm under cyclic axial loading. Comparing the stability of fixation between the Lisfranc plate and the screws, the differences in motion were all 0.3mm or lower, with no clinically significant differences (p>0.16). CONCLUSIONS: Diastasis at the Lisfranc joint following fixation with a novel plate or transarticular screw fixation were comparable. Therefore, the Lisfranc plate may provide adequate support without risk of iatrogenic injury to the articular cartilage.


Asunto(s)
Placas Óseas , Tornillos Óseos , Traumatismos de los Pies/cirugía , Articulaciones del Pie/cirugía , Huesos Metatarsianos/cirugía , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Traumatismos de los Pies/fisiopatología , Articulaciones del Pie/lesiones , Humanos , Ligamentos Articulares/fisiopatología , Ligamentos Articulares/cirugía , Masculino , Huesos Metatarsianos/fisiopatología
15.
Foot Ankle Spec ; 10(4): 322-328, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27881829

RESUMEN

Common surgical treatment of first tarsal-metatarsal arthritis is by first metatarsocuneiform joint arthrodesis. While crossed-screw and locking plate fixation are the most widely used methods, a novel construct was designed to alleviate soft tissue irritation while still providing stable fixation. Using anatomic first metatarsal and medial cuneiform composites, we compared 3 arthrodesis implants (crossed-screw, dorsal locking plate, and IO Fix) under 2 cyclic bending loading scenarios (cantilever and 4-point bending). Additionally, the optimal orientation (plantar-dorsal or dorsal-plantar) of the IO Fix construct was determined. Failure load, diastasis, joint space angle, and axial and angular stiffness were determined. Both crossed-screw fixation and the IO Fix constructs experienced significantly higher failure loads than the dorsal locking plate during both loading scenarios. Additionally, they had lower plantar diastasis and joint space angle at failure than the plate. Moreover, the plantar-dorsal IO Fix construct was significantly stiffer than the crossed-screw during cantilever bending. Finally, the plantar-dorsal orientation of the IO Fix device had higher failure load and lower diastasis and angle at failure than in the dorsal-plantar orientation. The results suggest that the IO Fix system can reduce motion at the interfragmentary site and ensure compression for healing comparable to that of the crossed-screw fixation. LEVELS OF EVIDENCE: Level V: Bench testing.


Asunto(s)
Artrodesis/instrumentación , Articulaciones del Pie/cirugía , Ensayo de Materiales , Huesos Metatarsianos/cirugía , Dispositivos de Fijación Ortopédica , Huesos Tarsianos/cirugía , Artrodesis/métodos , Fenómenos Biomecánicos , Diseño de Equipo , Humanos , Modelos Biológicos
16.
J Bone Joint Surg Am ; 98(19): 1598-1605, 2016 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-27707845

RESUMEN

BACKGROUND: A successful outcome for the treatment of idiopathic clubfoot is believed to require adequate adherence to brace use. Previous studies have relied on parental reporting of brace application. We used temperature sensors to determine the adherence to the bracing protocol, the accuracy of parent-reported use, and differences in adherence between patients who experienced relapse of deformity and those who did not. METHODS: Using wireless sensors attached to brace sandals, we monitored brace wear over a 3-month period in this cross-sectional study involving 48 patients in 4 age-based groups: 6 to 12 months (Group 1), >1 to 2 years (Group 2), >2 to 3 years (Group 3), and >3 to 4 years (Group 4). Parents were blinded to the purpose of the sensors. The mean number of hours of daily brace use as measured by the sensors was compared with the physician-recommended hours and parent-reported hours of brace use. RESULTS: Sensors were retrieved from 44 of 48 patients. Overall, the median brace use recorded by the sensors was 62% (range, 5% to 125%) of that recommended by the physician, and 77% (range, 6% to 213%) of that reported by the parents. For Groups 1 to 3, the difference between the physician-recommended and measured number of hours of daily brace use was significant (p ≤ 0.002), and the difference between the parent-reported and measured number of hours of daily brace use was also significant (p ≤ 0.013). Eight (18%) of the 44 patients who completed the study experienced relapse during the period of monitoring; most importantly, the mean number of hours of brace wear for these patients, 5 hours per day (median, 4; and standard deviation [SD], 3 hours per day) was significantly lower than the 8 hours per day for those who did not experience relapse (median, 9; and SD, 5 hours per day) (p = 0.045). CONCLUSIONS: The present study objectively quantified the number of daily hours of post-corrective brace wear for patients with clubfoot in varying age groups and provides an estimate of the number of hours required to avoid relapse. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Tirantes , Pie Equinovaro/terapia , Cooperación del Paciente , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Prospectivos , Resultado del Tratamiento
17.
Can J Gastroenterol ; 27(5): 281-5, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23712303

RESUMEN

Enterohemorrhagic Escherichia coli serotype O157:H7 is a food- and waterborne pathogen that causes significant morbidity and mortality in both developing and industrialized nations. The present review focuses on the history, epidemiology and evolution of the pathogen; provides a mechanistic overview of major virulence factors (including Shiga toxins, locus of enterocyte effacement pathogenicity island and pO157 plasmid); discusses host immune responses to infection; considers available animal models; and provides an overview of current and potential future management considerations.


Asunto(s)
Infecciones por Escherichia coli/terapia , Escherichia coli O157/patogenicidad , Interacciones Huésped-Patógeno , Animales , Modelos Animales de Enfermedad , Infecciones por Escherichia coli/epidemiología , Infecciones por Escherichia coli/microbiología , Escherichia coli O157/inmunología , Proteínas de Escherichia coli/metabolismo , Humanos , Fosfoproteínas/metabolismo , Plásmidos , Toxinas Shiga/metabolismo
18.
Cell Microbiol ; 15(3): 446-57, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23072252

RESUMEN

Adherent-invasive Escherichia coli (AIEC) is a pathogen isolated from the ileum of patients with Crohn disease. IFNγ is a key mediator of immunity, which regulates inflammatory responses to microbial infections. Previously, we showed enterohemorrhagic E. coli prevents STAT1 activation. The aim of this study was to determine whether activation of STAT1 by IFNγ was prevented by AIEC infection, and to define the mechanisms used. Human epithelial cells were infected with three different AIEC strains or other pathogenic and commensal E. coli strains. Following infection, cells were stimulated with IFNγ, and STAT1 activation was monitored by immunoblotting. Our data show that live AIEC with active protein synthesis machinery is able to prevent IFNγ-mediated STAT1 phosphorylation, and that a secreted factor may be involved. We conclude that the suppression of epithelial cell STAT1 signal transduction by AIEC strains isolated from patients with Crohn disease represents a novel mechanism by which the pathogen evades host immune responses to the infection.


Asunto(s)
Células Epiteliales/inmunología , Células Epiteliales/microbiología , Escherichia coli/patogenicidad , Interacciones Huésped-Patógeno , Evasión Inmune , Interferón gamma/inmunología , Factor de Transcripción STAT1/antagonistas & inhibidores , Línea Celular , Escherichia coli/inmunología , Humanos , Fosforilación , Procesamiento Proteico-Postraduccional
19.
Infect Immun ; 80(7): 2307-15, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22526675

RESUMEN

Enterohemorrhagic Escherichia coli (EHEC) serotype O157:H7 is a food-borne pathogen that causes significant morbidity and mortality in developing and industrialized nations. EHEC infection of host epithelial cells is capable of inhibiting the gamma interferon (IFN-γ) proinflammatory pathway through the inhibition of Stat-1 phosphorylation, which is important for host defense against microbial pathogens. The aim of this study was to determine the bacterial factors involved in the inhibition of Stat-1 tyrosine phosphorylation. Human HEp-2 and Caco-2 epithelial cells were challenged directly with either EHEC or bacterial culture supernatants and stimulated with IFN-γ, and then the protein extracts were analyzed by immunoblotting. The data showed that IFN-γ-mediated Stat-1 tyrosine phosphorylation was inhibited by EHEC secreted proteins. Using two-dimensional difference gel electrophoresis, EHEC Shiga toxins were identified as candidate inhibitory factors. EHEC Shiga toxin mutants were then generated and complemented in trans, and mutant culture supernatant was supplemented with purified Stx to confirm their ability to subvert IFN-γ-mediated cell activation. We conclude that while other factors are likely involved in the suppression of IFN-γ-mediated Stat-1 tyrosine phosphorylation, E. coli-derived Shiga toxins represent a novel mechanism by which EHEC evades the host immune system.


Asunto(s)
Escherichia coli O157/inmunología , Escherichia coli O157/patogenicidad , Evasión Inmune , Interferón gamma/inmunología , Factor de Transcripción STAT1/inmunología , Toxinas Shiga/inmunología , Toxinas Shiga/toxicidad , Western Blotting , Línea Celular , Electroforesis en Gel Bidimensional , Células Epiteliales/inmunología , Células Epiteliales/microbiología , Humanos , Interferón gamma/antagonistas & inhibidores , Fosforilación , Proteoma/análisis , Factor de Transcripción STAT1/metabolismo
20.
PLoS One ; 7(1): e30145, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22253910

RESUMEN

Enterohemorrhagic Escherichia coli serotype O157:H7 is a food borne enteric bacterial pathogen that causes significant morbidity and mortality in both developing and industrialized nations. E. coli O157:H7 infection of host epithelial cells inhibits the interferon gamma pro-inflammatory signaling pathway, which is important for host defense against microbial pathogens, through the inhibition of Stat-1 tyrosine phosphorylation. The aim of this study was to determine which bacterial factors are involved in the inhibition of Stat-1 tyrosine phosphorylation. Human epithelial cells were challenged with either live bacteria or bacterial-derived culture supernatants, stimulated with interferon-gamma, and epithelial cell protein extracts were then analyzed by immunoblotting. The results show that Stat-1 tyrosine phosphorylation was inhibited by E. coli O157:H7 secreted proteins. Using sequential anion exchange and size exclusion chromatography, YodA was identified, but not confirmed to mediate subversion of the Stat-1 signaling pathway using isogenic mutants. We conclude that E. coli O157:H7 subverts Stat-1 tyrosine phosphorylation in response to interferon-gamma through a still as yet unidentified secreted bacterial protein.


Asunto(s)
Escherichia coli O157/inmunología , Interferón gamma/farmacología , Factor de Transcripción STAT1/metabolismo , Línea Celular , Células Epiteliales/efectos de los fármacos , Células Epiteliales/metabolismo , Células Epiteliales/microbiología , Escherichia coli O157/efectos de los fármacos , Proteínas de Escherichia coli/metabolismo , Humanos , Mutación/genética , Fosforilación/efectos de los fármacos , Fosfotirosina/metabolismo , Transducción de Señal/efectos de los fármacos , Transducción de Señal/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...