Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neural Eng ; 16(2): 026011, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30523839

RESUMEN

OBJECTIVE: Brain-computer interfaces (BCIs) are a promising technology for the restoration of function to people with paralysis, especially for controlling coordinated reaching. Typical BCI studies decode Cartesian endpoint velocities as commands, but human arm movements might be better controlled in a joint-based coordinate frame, which may match underlying movement encoding in the motor cortex. A better understanding of BCI controlled reaching by people with paralysis may lead to performance improvements in brain-controlled assistive devices. APPROACH: Two intracortical BCI participants in the BrainGate2 pilot clinical trial performed a visual 3D endpoint virtual reality reaching task using two decoders: Cartesian and joint velocity. Task performance metrics (i.e. success rate and path efficiency) and single feature and population tuning were compared across the two decoder conditions. The participants also demonstrated the first BCI control of a fourth dimension of reaching, the arm's swivel angle, in a 4D posture matching task. MAIN RESULTS: Both users achieved significantly higher success rates using Cartesian velocity control, and joint controlled trajectories were more variable and significantly more curved. Neural tuning analyses showed that most single feature activity was best described by a Cartesian kinematic encoding model, and population analyses revealed only slight differences in aggregate activity between the decoder conditions. Simulations of a BCI user reproduced trajectory features seen during closed-loop joint control when assuming only Cartesian-tuned features passed through a joint decoder. With minimal training, both participants controlled the virtual arm's swivel angle to complete a 4D posture matching task, and achieved significantly higher success using a Cartesian + swivel velocity decoder compared to a joint velocity decoder. SIGNIFICANCE: These results suggest that Cartesian velocity command interfaces may provide better BCI control of arm movements than other kinematic variables, even in 4D posture tasks with swivel angle targets.


Asunto(s)
Interfaces Cerebro-Computador , Articulaciones/fisiología , Corteza Motora/fisiología , Postura/fisiología , Desempeño Psicomotor/fisiología , Cuadriplejía/rehabilitación , Brazo/fisiología , Fenómenos Biomecánicos , Calibración , Humanos , Aprendizaje , Masculino , Persona de Mediana Edad , Proyectos Piloto , Dispositivos de Autoayuda , Procesamiento de Señales Asistido por Computador , Realidad Virtual
2.
J Neural Eng ; 15(2): 026014, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29199642

RESUMEN

OBJECTIVE: Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain-computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. APPROACH: One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. MAIN RESULTS: Electrical artifacts resulting from surface stimulation were 175 × larger than baseline neural recordings (which were 110 µV peak-to-peak), while intramuscular stimulation artifacts were only 4 × larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µV and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. SIGNIFICANCE: The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and almost completely restored iBCI decoding performance (>90% recovery for surface stimulation and full recovery for intramuscular stimulation). The results demonstrate that FES-induced artifacts can be easily mitigated in FES + iBCI systems by using LRR for artifact reduction, and suggest that the LRR method may also be useful in other noise reduction applications.


Asunto(s)
Artefactos , Estimulación Encefálica Profunda/métodos , Electrodos Implantados , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Procesamiento de Señales Asistido por Computador , Brazo/inervación , Brazo/fisiología , Interfaces Cerebro-Computador , Estimulación Encefálica Profunda/instrumentación , Humanos , Microelectrodos , Corteza Motora/cirugía , Músculo Esquelético/inervación , Proyectos Piloto , Traumatismos de la Médula Espinal/diagnóstico , Traumatismos de la Médula Espinal/fisiopatología , Traumatismos de la Médula Espinal/terapia , Vértebras Torácicas
3.
J Neural Eng ; 13(2): 023001, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26924826

RESUMEN

OBJECTIVE: The Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) believes it is important to help stakeholders (e.g., manufacturers, health-care professionals, patients, patient advocates, academia, and other government agencies) navigate the regulatory landscape for medical devices. For innovative devices involving brain-computer interfaces, this is particularly important. APPROACH: Towards this goal, on 21 November, 2014, CDRH held an open public workshop on its White Oak, MD campus with the aim of fostering an open discussion on the scientific and clinical considerations associated with the development of brain-computer interface (BCI) devices, defined for the purposes of this workshop as neuroprostheses that interface with the central or peripheral nervous system to restore lost motor or sensory capabilities. MAIN RESULTS: This paper summarizes the presentations and discussions from that workshop. SIGNIFICANCE: CDRH plans to use this information to develop regulatory considerations that will promote innovation while maintaining appropriate patient protections. FDA plans to build on advances in regulatory science and input provided in this workshop to develop guidance that provides recommendations for premarket submissions for BCI devices. These proceedings will be a resource for the BCI community during the development of medical devices for consumers.


Asunto(s)
Amputados , Interfaces Cerebro-Computador/tendencias , Equipos de Comunicación para Personas con Discapacidad/tendencias , Aprobación de Recursos , Parálisis/terapia , Amputación Quirúrgica , Interfaces Cerebro-Computador/normas , Equipos de Comunicación para Personas con Discapacidad/normas , Aprobación de Recursos/normas , Humanos , Maryland , Parálisis/epidemiología , Estados Unidos/epidemiología
4.
J Neural Eng ; 8(3): 034003, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21543840

RESUMEN

Functional electrical stimulation (FES), the coordinated electrical activation of multiple muscles, has been used to restore arm and hand function in people with paralysis. User interfaces for such systems typically derive commands from mechanically unrelated parts of the body with retained volitional control, and are unnatural and unable to simultaneously command the various joints of the arm. Neural interface systems, based on spiking intracortical signals recorded from the arm area of motor cortex, have shown the ability to control computer cursors, robotic arms and individual muscles in intact non-human primates. Such neural interface systems may thus offer a more natural source of commands for restoring dexterous movements via FES. However, the ability to use decoded neural signals to control the complex mechanical dynamics of a reanimated human limb, rather than the kinematics of a computer mouse, has not been demonstrated. This study demonstrates the ability of an individual with long-standing tetraplegia to use cortical neuron recordings to command the real-time movements of a simulated dynamic arm. This virtual arm replicates the dynamics associated with arm mass and muscle contractile properties, as well as those of an FES feedback controller that converts user commands into the required muscle activation patterns. An individual with long-standing tetraplegia was thus able to control a virtual, two-joint, dynamic arm in real time using commands derived from an existing human intracortical interface technology. These results show the feasibility of combining such an intracortical interface with existing FES systems to provide a high-performance, natural system for restoring arm and hand function in individuals with extensive paralysis.


Asunto(s)
Brazo/fisiopatología , Electroencefalografía/métodos , Modelos Neurológicos , Corteza Motora/fisiopatología , Red Nerviosa/fisiopatología , Cuadriplejía/fisiopatología , Cuadriplejía/rehabilitación , Brazo/inervación , Biomimética/métodos , Simulación por Computador , Terapia por Estimulación Eléctrica/métodos , Potenciales Evocados Motores , Humanos , Movimiento , Músculo Esquelético/inervación , Músculo Esquelético/fisiopatología
5.
J Neural Eng ; 8(2): 025027, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21436513

RESUMEN

The ongoing pilot clinical trial of the BrainGate neural interface system aims in part to assess the feasibility of using neural activity obtained from a small-scale, chronically implanted, intracortical microelectrode array to provide control signals for a neural prosthesis system. Critical questions include how long implanted microelectrodes will record useful neural signals, how reliably those signals can be acquired and decoded, and how effectively they can be used to control various assistive technologies such as computers and robotic assistive devices, or to enable functional electrical stimulation of paralyzed muscles. Here we examined these questions by assessing neural cursor control and BrainGate system characteristics on five consecutive days 1000 days after implant of a 4 × 4 mm array of 100 microelectrodes in the motor cortex of a human with longstanding tetraplegia subsequent to a brainstem stroke. On each of five prospectively-selected days we performed time-amplitude sorting of neuronal spiking activity, trained a population-based Kalman velocity decoding filter combined with a linear discriminant click state classifier, and then assessed closed-loop point-and-click cursor control. The participant performed both an eight-target center-out task and a random target Fitts metric task which was adapted from a human-computer interaction ISO standard used to quantify performance of computer input devices. The neural interface system was further characterized by daily measurement of electrode impedances, unit waveforms and local field potentials. Across the five days, spiking signals were obtained from 41 of 96 electrodes and were successfully decoded to provide neural cursor point-and-click control with a mean task performance of 91.3% ± 0.1% (mean ± s.d.) correct target acquisition. Results across five consecutive days demonstrate that a neural interface system based on an intracortical microelectrode array can provide repeatable, accurate point-and-click control of a computer interface to an individual with tetraplegia 1000 days after implantation of this sensor.


Asunto(s)
Encéfalo/fisiopatología , Electrodos Implantados , Electroencefalografía/instrumentación , Potenciales Evocados , Microelectrodos , Cuadriplejía/fisiopatología , Interfaz Usuario-Computador , Electroencefalografía/métodos , Femenino , Humanos , Imaginación , Persona de Mediana Edad , Cuadriplejía/diagnóstico , Cuadriplejía/rehabilitación , Resultado del Tratamiento
6.
J Neurointerv Surg ; 1(2): 171-4, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21994292

RESUMEN

Cervical internal carotid artery (ICA) occlusions causing acute ischemic stroke have extremely poor outcomes without rapid re-establishment of cerebral perfusion. Given the high risk for early recurrent stroke, carotid stenting at the time of intra-arterial therapy may be crucial to improving outcomes. To our knowledge, there are only two prior case series that address intra-arterial reperfusion therapy and stent placement within six hours of stroke onset (the hyperacute period). We present two cases to further support the feasibility of this intervention in the hyperacute period, and report the potential utility of MRI in identifying patients most likely to benefit from this procedure.


Asunto(s)
Estenosis Carotídea/patología , Estenosis Carotídea/terapia , Revascularización Cerebral/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Stents , Enfermedad Aguda , Anciano , Estenosis Carotídea/diagnóstico por imagen , Angiografía Cerebral , Humanos , Masculino , Resultado del Tratamiento
7.
IEEE Trans Neural Syst Rehabil Eng ; 14(2): 131-4, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16792277

RESUMEN

This paper describes the outcome of discussions held during the Third International BCI Meeting at a workshop charged with reviewing and evaluating the current state of and issues relevant to brain-computer interface (BCI) clinical applications. These include potential BCI users, applications, validation, getting BCIs to users, role of government and industry, plasticity, and ethics.


Asunto(s)
Biotecnología/ética , Biotecnología/tendencias , Equipos de Comunicación para Personas con Discapacidad/ética , Equipos de Comunicación para Personas con Discapacidad/tendencias , Electroencefalografía/métodos , Enfermedades Neuromusculares/rehabilitación , Interfaz Usuario-Computador , Algoritmos , Encéfalo/fisiología , Electroencefalografía/ética , Humanos , Sistemas Hombre-Máquina , Selección de Paciente/ética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...