Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Front Neurol ; 15: 1366239, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711557

RESUMEN

Introduction: This study sought to determine the effect of Occupational Safety and Health Administration (OSHA) compliant noise on auditory health and assess whether pre-noise near infrared (NIR) light therapy can mitigate the effects of noise exposure. Methods: Over four visits, participants (n = 30, NCT#: 03834714) with normal hearing completed baseline hearing health assessments followed by exposure to open ear, continuous pink noise at 94 dBA for 15 min. Immediately thereafter, post-noise hearing tests at 3000, 4000, and 6000 Hz and distortion product otoacoustic emissions (DPOAEs) were conducted along with the Modified Rhyme Test (MRT), Masking Level Difference Test (MLD), and Fixed Level Frequency Tests (FLFT) [collectively referred to as the Central and Peripheral Auditory Test Battery (CPATB)] to acquire baseline noise sensitivity profiles. Participants were then randomized to either Active or Sham NIR light therapy for 30 min binaurally to conclude Visit 1. Visit 2 (≥24 and ≤ 48 h from Visit 1) began with an additional 30-min session of Active NIR light therapy or Sham followed by repeat CPATB testing and noise exposure. Post-noise testing was again conducted immediately after noise exposure to assess the effect of NIR light therapy. The remaining visits were conducted following ≥2 weeks of noise rest in a cross-over design (i.e., those who had received Active NIR light therapy in Visits 1 and 2 received Sham therapy in Visits 3 and 4). Results: Recovery hearing tests and DPOAEs were completed at the end of each visit. Participants experienced temporary threshold shifts (TTS) immediately following noise exposure, with a mean shift of 6.79 dB HL (±6.25), 10.61 dB HL (±6.89), and 7.30 dB HL (±7.25) at 3000, 4000, and 6000 Hz, respectively, though all thresholds returned to baseline at 3000, 4000, and 6000 Hz within 75 min of noise exposure. Paradoxically, Active NIR light therapy threshold shifts were statistically higher than Sham therapy at 3000 Hz (p = 0.04), but no other differences were observed at the other frequencies tested. An age sub-analysis demonstrated that TTS among younger adults were generally larger in the Sham therapy group versus Active therapy, though this was not statistically different. There were no differences in CPATB test results across Active or Sham groups. Finally, we observed no changes in auditory function or central processing following noise exposure, suggestive of healthy and resilient inner ears. Conclusion: In this study, locally administered NIR prior to noise exposure did not induce a significant protective effect in mitigating noise-induced TTS. Further exploration is needed to implement effective dosage and administration for this promising otoprotective therapy.

2.
PLoS One ; 19(4): e0292566, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38564600

RESUMEN

Post vaccine immunity following COVID-19 mRNA vaccination may be driven by extrinsic, or controllable and intrinsic, or inherent health factors. Thus, we investigated the effects of extrinsic and intrinsic on the peak antibody response following COVID-19 primary vaccination and on the trajectory of peak antibody magnitude and durability over time. Participants in a longitudinal cohort attended visits every 3 months for up to 2 years following enrollment. At baseline, participants provided information on their demographics, recreational behaviors, and comorbid health conditions which guided our model selection process. Blood samples were collected for serum processing and spike antibody testing at each visit. Cross-sectional and longitudinal models (linear-mixed effects models) were generated to assess the relationship between selected intrinsic and extrinsic health factors on peak antibody following vaccination and to determine the influence of these predictors on antibody over time. Following cross-sectional analysis, we observed higher peak antibody titers after primary vaccination in females, those who reported recreational drug use, younger age, and prior COVID-19 history. Following booster vaccination, females and Hispanics had higher peak titers after the 3rd and 4th doses, respectively. Longitudinal models demonstrated that Moderna mRNA-1273 recipients, females, and those previously vaccinated had increased peak titers over time. Moreover, drug users and half-dose Moderna mRNA-1273 recipients had higher peak antibody titers over time following the first booster, while no predictive factors significantly affected post-second booster antibody responses. Overall, both intrinsic and extrinsic health factors play a significant role in shaping humoral immunogenicity after initial vaccination and the first booster. The absence of predictive factors for second booster immunogenicity suggests a more robust and consistent immune response after the second booster vaccine administration.


Asunto(s)
COVID-19 , SARS-CoV-2 , Femenino , Humanos , Formación de Anticuerpos , COVID-19/prevención & control , Vacuna nCoV-2019 mRNA-1273 , Estudios Transversales , Anticuerpos , Vacunación , Anticuerpos Antivirales
3.
Otol Neurotol ; 45(4): 376-385, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38361325

RESUMEN

OBJECTIVE: To investigate if pharmacological treatment with prednisone and L-N-acetylcysteine (STE + NAC) influence functional hearing preservation in cochlear implant (CI) surgery. STUDY DESIGNS: Preimplantation and postimplantation longitudinal case-control study. SETTING: Tertiary referral center. PATIENTS: Pediatric and adult recipients of CI with preimplantation functional hearing defined as an average of air-conducted thresholds at 125, 250, and 500 Hz (low-frequency pure-tone average [LFPTA]) <80 dB. INTERVENTIONS: Preimplantation and postimplantation audiometry. Weight-adjusted oral prednisone and L-N-acetylcysteine starting 2 days before surgery (Miami cocktail). Prednisone was continued for 3 days and L-N-acetylcysteine for 12 days after surgery, respectively. Cochlear implantation with conventional length electrodes. MAIN OUTCOME MEASURES: Proportion of patients with LFPTA <80 dB, and LFPTA change at 1-year postimplantation. RESULTS: All 61 patients received intratympanic and intravenous dexamethasone intraoperatively, with 41 patients receiving STE + NAC and 20 patients not receiving STE + NAC. At 1-year postimplantation, the proportion of functional hearing preservation was 83% in the STE + NAC group compared with 55% of subjects who did not receive STE + NAC ( p = 0.0302). The median LFPTA change for STE + NAC-treated and not treated subjects was 8.33 dB (mean, 13.82 ± 17.4 dB) and 18.34 dB (mean, 26.5 ± 23.4 dB), respectively ( p = 0.0401, Wilcoxon rank test). Perioperative STE + NAC treatment resulted in 10 dB of LFPTA better hearing than when not receiving this treatment. Better low-frequency preimplantation hearing thresholds were predictive of postimplantation functional hearing. No serious side effects were reported. CONCLUSION: Perioperative STE + NAC, "The Miami Cocktail," was safe and superior to intraoperative steroids alone in functional hearing preservation 1-year after cochlear implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Humanos , Niño , Implantación Coclear/métodos , Estudios de Casos y Controles , Prednisona , Acetilcisteína , Estudios Retrospectivos , Umbral Auditivo , Audiometría de Tonos Puros , Audición , Resultado del Tratamiento
4.
Am J Otolaryngol ; 45(3): 104220, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38219629

RESUMEN

BACKGROUND: As artificial intelligence (AI) is integrating into the healthcare sphere, there is a need to evaluate its effectiveness in the various subspecialties of medicine, including otolaryngology. Our study intends to provide a cursory review of ChatGPT's diagnostic capability, ability to convey pathophysiology in simple terms, accuracy in providing management recommendations, and appropriateness in follow up and post-operative recommendations in common otolaryngologic conditions. METHODS: Adenotonsillectomy (T&A), tympanoplasty (TP), endoscopic sinus surgery (ESS), parotidectomy (PT), and total laryngectomy (TL) were substituted for the word procedure in the following five questions and input into ChatGPT version 3.5: "How do I know if I need (procedure)," "What are treatment alternatives to (procedure)," "What are the risks of (procedure)," "How is a (procedure) performed," and "What is the recovery process for (procedure)?" Two independent study members analyzed the output and discrepancies were reviewed, discussed, and reconciled between study members. RESULTS: In terms of management recommendations, ChatGPT was able to give generalized statements of evaluation, need for intervention, and the basics of the procedure without major aberrant errors or risks of safety. ChatGPT was successful in providing appropriate treatment alternatives in all procedures tested. When queried for methodology, risks, and procedural steps, ChatGPT lacked precision in the description of procedural steps, missed key surgical details, and did not accurately provide all major risks of each procedure. In terms of the recovery process, ChatGPT showed promise in T&A, TP, ESS, and PT but struggled in the complexity of TL, stating the patient could speak immediately after surgery without speech therapy. CONCLUSIONS: ChatGPT accurately demonstrated the need for intervention, management recommendations, and treatment alternatives in common ENT procedures. However, ChatGPT was not able to replace an otolaryngologist's clinical reasoning necessary to discuss procedural methodology, risks, and the recovery process in complex procedures. As AI becomes further integrated into healthcare, there is a need to continue to explore its indications, evaluate its limits, and refine its use to the otolaryngologist's advantage.


Asunto(s)
Inteligencia Artificial , Otolaringología , Humanos , Enfermedades Otorrinolaringológicas/cirugía , Enfermedades Otorrinolaringológicas/terapia , Tonsilectomía/métodos , Adenoidectomía/métodos , Endoscopía/métodos , Timpanoplastia/métodos , Laringectomía/métodos
5.
J Occup Environ Med ; 66(2): e48-e53, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38013399

RESUMEN

OBJECTIVE: The effect of stress on vaccine-induced humoral immunity and therapeutic interventions to mitigate pandemic-related stress remain underexplored. METHOD: Participants in a longitudinal cohort study ( n = 189) completed a validated measure, GAD-7, and 10-instrument stress measure to assess stress and anxiety after severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination. Serum was collected to obtain SARS-CoV-2 antibody titer levels. RESULTS: Participants experienced increased stress due to the SARS-CoV-2 pandemic with a positive correlation between GAD-7 scores and peak antibody titers overall; however, there was a negative association with scores commensurate with severe anxiety. Health care workers and younger participants were more significantly affected by anxiety. CONCLUSIONS: Mild anxiety levels may have immune-enhancing effects, whereas severe anxiety may cause antibody generation reduction. Mental health-focused interventions are imperative for younger adults and health care workers. Young adults may be more resilient to increased stress levels.


Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto Joven , Humanos , Inmunidad Humoral , Estudios Longitudinales , Pandemias , COVID-19/epidemiología , Ansiedad , Personal de Salud , Vacunación
6.
Am J Otolaryngol ; 45(1): 104047, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37738881

RESUMEN

OBJECTIVE: To determine whether subjects who have recovered from COVID-19 smell and taste disturbance perform similarly to their COVID-naïve baseline, on gold-standard smell and taste tests. STUDY DESIGN: Prospective cross-sectional study. SETTING: University of Miami Department of Otolaryngology in Miami, FL between September 2021, and August 2022. METHODS: Those previously COVID-19 positive composed the experimental group, those who reported being COVID-naïve composed the control group. Mean total score for the UPSIT Smell Test, and the Burghart Taste Strip test were the primary outcome measures. RESULTS: 70 adult subjects (35 former COVID-positive, 35 COVID-naïve) were enrolled, with 21 females and 14 males in each group. 87 % of all subjects were white and were almost distributed evenly between Hispanic and non-Hispanic. Mean UPSIT total score for the experimental group was 30.6 (95 % CI 28.9-32.3), mean UPSIT total score for the control group was 31.2 (95 % CI 29.7-32.8). Mean Burghart total score for the experimental group was 11.3 (95 % CI 10.6-12.0), mean Burghart total score for the control group was 10.7 (95 % CI 9.7-11.8). These showed a significant overlap of the 95 % CI of the mean total score between the control group and the experimental group, suggesting no significant difference between the two groups. CONCLUSION: These results suggest that COVID-19 patients who experience smell and taste disturbance and recover, regain sensory ability similar to their pre-COVID ability. Further study is needed to validate these findings, but the results are promising in the long-term recovery of COVID-19.


Asunto(s)
COVID-19 , Trastornos del Olfato , Adulto , Masculino , Femenino , Humanos , Estudios Transversales , Trastornos del Olfato/etiología , Estudios Prospectivos , Recuperación de la Función , Olfato , Disgeusia
7.
Hum Genomics ; 17(1): 103, 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-37996878

RESUMEN

BACKGROUND: We analyzed the genetic causes of sensorineural hearing loss in racial and ethnic minorities of South Florida by reviewing demographic, phenotypic, and genetic data on 136 patients presenting to the Hereditary Hearing Loss Clinic at the University of Miami. In our retrospective chart review, of these patients, half self-identified as Hispanic, and the self-identified racial distribution was 115 (86%) White, 15 (11%) Black, and 6 (4%) Asian. Our analysis helps to reduce the gap in understanding the prevalence, impact, and genetic factors related to hearing loss among diverse populations. RESULTS: The causative gene variant or variants were identified in 54 (40%) patients, with no significant difference in the molecular diagnostic rate between Hispanics and Non-Hispanics. However, the total solve rate based on race was 40%, 47%, and 17% in Whites, Blacks, and Asians, respectively. In Non-Hispanic Whites, 16 different variants were identified in 13 genes, with GJB2 (32%), MYO7A (11%), and SLC26A4 (11%) being the most frequently implicated genes. In White Hispanics, 34 variants were identified in 20 genes, with GJB2 (22%), MYO7A (7%), and STRC-CATSPER2 (7%) being the most common. In the Non-Hispanic Black cohort, the gene distribution was evenly dispersed, with 11 variants occurring in 7 genes, and no variant was identified in 3 Hispanic Black probands. For the Asian cohort, only one gene variant was found out of 6 patients. CONCLUSION: This study demonstrates that the diagnostic rate of genetic studies in hearing loss varies according to race in South Florida, with more heterogeneity in racial and ethnic minorities. Further studies to delineate deafness gene variants in underrepresented populations, such as African Americans/Blacks from Hispanic groups, are much needed to reduce racial and ethnic disparities in genetic diagnoses.


Asunto(s)
Pérdida Auditiva Sensorineural , Humanos , Asiático/genética , Negro o Afroamericano/genética , ADN/genética , Florida/epidemiología , Pérdida Auditiva Sensorineural/epidemiología , Pérdida Auditiva Sensorineural/genética , Hispánicos o Latinos/genética , Péptidos y Proteínas de Señalización Intercelular , Estudios Retrospectivos , Blanco/genética
8.
Front Neurol ; 14: 1081084, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37396777

RESUMEN

Introduction: Coordinated alignment of the eyes during gaze fixation and eye movements are an important component of normal visual function. We have previously described the coordinated behavior of convergence eye movements and pupillary responses using a 0.1 Hz binocular disparity-driven sine profile and a step profile. The goal of this publication is to further characterize ocular vergence-pupil size coordination over a wider range of frequencies of ocular disparity stimulation in normal subjects. Methods: Binocular disparity stimulation is generated by presentation of independent targets to each eye on a virtual reality display, while eye movements and pupil size are measured by an embedded video-oculography system. This design allows us to study two complimentary analyses of this motion relationship. First, a macroscale analysis describes the vergence angle of the eyes in response to binocular disparity target movement and pupil area as a function of the observed vergence response. Second, a microscale analysis performs a piecewise linear decomposition of the vergence angle and pupil relationship to permit more nuanced findings. Results: These analyses identified three main features of controlled coupling of pupil and convergence eye movements. First, a near response relationship operates with increasing prevalence during convergence (relative to the "baseline" angle); the coupling is higher with increased convergence in this range. Second, the prevalence of "near response"-type coupling decreases monotonically in the diverging direction; the decrease persists after the targets move (converge back) from maximum divergence toward the baseline positions, with a minimum prevalence of near response segments near the baseline target position. Third, an opposite polarity pupil response is infrequent, but tends to be more prevalent when the vergence angles are at maximum convergence or divergence for a sinusoidal binocular disparity task. Discussion: We suggest that the latter response is an exploratory "range-validation" when binocular disparity is relatively constant. In a broader sense, these findings describe operating characteristics of the near response in normal subjects and form a basis for quantitative assessments of function in conditions such as convergence insufficiency and mild traumatic brain injury.

9.
Front Immunol ; 14: 971277, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36845120

RESUMEN

Introduction: The influence of pre-existing humoral immunity, inter-individual demographic factors, and vaccine-associated reactogenicity on immunogenicity following COVID vaccination remains poorly understood. Methods: Ten-fold cross-validated least absolute shrinkage and selection operator (LASSO) and linear mixed effects models were used to evaluate symptoms experienced by COVID+ participants during natural infection and following SARS-CoV-2 mRNA vaccination along with demographics as predictors for antibody (AB) responses to recombinant spike protein in a longitudinal cohort study. Results: In previously infected individuals (n=33), AB were more durable and robust following primary vaccination when compared to natural infection alone. Higher AB were associated with experiencing dyspnea during natural infection, as was the total number of symptoms reported during the COVID-19 disease course. Both local and systemic symptoms following 1st and 2nd dose (n=49 and 48, respectively) of SARS-CoV-2 mRNA vaccines were predictive of higher AB after vaccination. Lastly, there was a significant temporal relationship between AB and days since infection or vaccination, suggesting that vaccination in COVID+ individuals is associated with a more robust immune response. Discussion: Experiencing systemic and local symptoms post-vaccine was suggestive of higher AB, which may confer greater protection.


Asunto(s)
COVID-19 , Inmunidad Humoral , Humanos , SARS-CoV-2 , COVID-19/prevención & control , Estudios Longitudinales , Vacunación/efectos adversos , ARN Mensajero
10.
Am J Otolaryngol ; 44(2): 103768, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36628910

RESUMEN

OBJECTIVES: METHODS: Retrospective chart review was performed of pediatric patients who underwent CT brain as part of a trauma pan-scan and dedicated temporal bone CT in the setting of head trauma. The original CT images were re-reviewed by two board certified Neuroradiologists in a blinded manner to determine the presence or absence of temporal bone fracture and if present, fracture line involvement of the 5 critical temporal bone anatomic structures. The dose length product (DLP), a measure of approximate total radiation dose delivered during CT scan (mGy-cm), was noted from the data available. RESULTS: There were 24 temporal bone fractures in a total of 29 patients (4 with bilateral fractures). There were 21 of 24 fractures that were correctly identified on trauma pan-scan CT with dedicated temporal bone CT considered as the diagnostic gold standard. There was a combined sensitivity and specificity of 91 % and 100 % respectively. The sensitivity and specificity in identifying involvement of critical structures were as follows: carotid canal (100 % and 100 %); ossicular chain (75 % and 100 %); tegmen tympani (60 % and 97.9 %); facial nerve canal (25 % and 100 %); otic capsule (N/A and 98.5 %). The median DLP for trauma pan-scan CT and temporal bone CT were 627 mGy-cm and 267 mGy-cm respectively. CONCLUSION: Dedicated TBCT is not required to accurately diagnose and characterize temporal bone fractures seen on trauma pan-scan CT. The radiation exposure of concurrent or subsequent dedicated temporal bone imaging is equal to approximately one half of the original trauma pan-scan CT.


Asunto(s)
Traumatismos Craneocerebrales , Fracturas Óseas , Fracturas Craneales , Humanos , Niño , Estudios Retrospectivos , Reducción Gradual de Medicamentos , Tomografía Computarizada por Rayos X/métodos , Fracturas Craneales/diagnóstico por imagen
11.
Otol Neurotol Open ; 3(4): e044, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38516545

RESUMEN

Objectives: Judgments of the subjective visual vertical (SVV) and subjective visual horizontal (SVH) while seated upright are commonly included in standard clinical test batteries for vestibular function. We examined SVV and SVH data from retrospective control to assess their statistical distributions and normative values for magnitudes of the preset effect, sex differences, and fixed-head versus head-free device platforms for assessment. Methods: Retrospective clinical SVV and SVH data from 2 test platforms, Neuro-otologic Test Center (NOTC) and the Neurolign Dx 100 (I-Portal Portable Assessment System Nystagmograph) were analyzed statistically (SPSS and MATLAB software) for 408 healthy male and female civilians and military service members, aged 18-50 years. Results: No prominent age-related effects were observed. The preset angle effects for both SVV and SVH, and their deviations from orthogonality, agree in magnitude with previous reports. Differences attributable to interactions with device type and sex are of small magnitude. Analyses confirmed that common clinical measure for SVV and SVH, the average of equal numbers of clockwise and counterclockwise preset trials, was not significantly affected by the test device or sex of the subject. Finally, distributional analyses failed to reject the hypothesis of underlying Gaussian distributions for the clinical metrics. Conclusions: z scores based on these normative findings can be used for objective detection of outliers from normal functional limits in the clinic.

12.
Front Neurosci ; 17: 1296458, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38292902

RESUMEN

Introduction: Exposure to occupational or recreational loud noise activates multiple biological regulatory circuits and damages the cochlea, causing permanent changes in hearing sensitivity. Currently, no effective clinical therapy is available for the treatment or mitigation of noise-induced hearing loss (NIHL). Here, we describe an application of localized and non-invasive therapeutic hypothermia and targeted temperature management of the inner ear to prevent NIHL. Methods: We developed a custom-designed cooling neck collar to reduce the temperature of the inner ear by 3-4°C post-injury to deliver mild therapeutic hypothermia. Results: This localized and non-invasive therapeutic hypothermia successfully mitigated NIHL in rats. Our results show that mild hypothermia can be applied quickly and safely to the inner ear following noise exposure. We show that localized hypothermia after NIHL preserves residual hearing and rescues noise-induced synaptopathy over a period of months. Discussion: This study establishes a minimally-invasive therapeutic paradigm with a high potential for rapid translation to the clinic for long-term preservation of hearing health.

13.
World Neurosurg ; 168: e297-e308, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36198364

RESUMEN

OBJECTIVE: The purpose of this study is to retrospectively evaluate the clinical and surgical outcomes of a large surgical series of vestibular schwannoma from North America over 20 years. METHODS: After institutional review board approval a retrospective review of the senior author's personal case logs to identify patients who had operations for vestibular schwannoma was performed. The clinical notes, operative record, preoperative and postoperative imagings, and long-term clinical follow-up notes were evaluated. RESULTS: A total of 415 patients who underwent 420 surgeries were identified from the years 1998-2021. The average length of follow-up was 3 years and 9 months. Overall, at last follow-up the rate of "good" facial nerve outcomes (House-Brackmann [HB] score I and II) was 86% and "poor" facial nerve outcomes (HB III-VI) was 14%. The amount of cerebellopontine angle extension (P = 0.023), tumor volume (P = 0.015), facial nerve consistency (P < 0.001), preoperative HB score (P < 0.001), and FN stimulation threshold at the end of the procedure (P < 0.001) were correlated to facial nerve function at the last follow-up. CONCLUSIONS: This study represents one of the largest recently reported surgical series of vestibular schwannoma in North American literature with available long term follow-up. Facial nerve outcomes correlated with cerebellopontine angle extension, tumor volume, facial nerve stimulation threshold, facial nerve consistency, preoperative facial nerve function, and history of a prior resection. Tumor recurrence remains significantly higher after subtotal resection. We believe the data supports a continuation of a strategy of general intent of gross total resection, greatly modifiable by intraoperative findings and judgment.


Asunto(s)
Neuroma Acústico , Humanos , Neuroma Acústico/diagnóstico por imagen , Neuroma Acústico/cirugía , Nervio Facial/diagnóstico por imagen , Nervio Facial/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/métodos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Complicaciones Posoperatorias/cirugía
14.
Otolaryngol Clin North Am ; 55(5): 983-991, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36088150

RESUMEN

As of today, there are no therapeutic measures for the prevention or treatment of noise-induced hearing loss (NIHL). The current preventative measures, including avoidance and personal protective hearing equipment, do not appear to be sufficient because there is an increasing number of people with NIHL, especially in the adolescent population. Therefore, we must find a therapy that prevents the impact of noise on hearing. Antioxidants are a promising option in preventing the damaging effects of noise by targeting free radicals but further studies are needed to confirm their efficacy in humans.


Asunto(s)
Pérdida Auditiva Provocada por Ruido , Acetilcisteína/uso terapéutico , Adolescente , Antioxidantes/farmacología , Antioxidantes/uso terapéutico , Audición , Pérdida Auditiva Provocada por Ruido/prevención & control , Humanos , Ruido/efectos adversos
15.
Vaccine ; 40(41): 5868-5872, 2022 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-36088193

RESUMEN

BACKGROUND: Breakthrough infection with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron variant (B.1.1.529) has occurred in populations with high vaccination rates. METHODS: In a longitudinal cohort study, pre-breakthrough infection sera for Omicron breakthroughs (n = 12) were analyzed. Assays utilized include a laboratory-developed solid phase binding assay to recombinant spike protein, a commercial assay to the S1 domain of the spike protein calibrated to the World Health Organization (WHO) standard, and a commercial solid-phase surrogate neutralizing activity (SNA) assay. All assays employed spike protein preparations based on sequences from the Wuhan-Hu-1 strain. RESULTS: Pre-breakthrough binding antibody titers ranged from 1:800 to 1:51,200 for the laboratory-developed binding assay, which correlated well and agreed quantitatively with the commercial spike S1 domain WHO calibrated assay. SNA was detected in 10/12 (83%) samples. CONCLUSIONS: Neither high binding titers nor SNA were markers of protection from Omicron infection/re-infection.


Asunto(s)
Anticuerpos Neutralizantes , COVID-19 , Anticuerpos Antivirales , Humanos , Estudios Longitudinales , Glicoproteínas de Membrana , Pruebas de Neutralización , Proteínas Recombinantes , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Proteínas del Envoltorio Viral
16.
Otol Neurotol ; 43(7): 789-796, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35861647

RESUMEN

OBJECTIVES: To evaluate the utility of intracochlear electrocochleography (ECochG) monitoring during cochlear implant (CI) surgery on postoperative hearing preservation. STUDY DESIGN: Prospective, randomized clinical trial. SETTING: Ten high-volume, tertiary care CI centers. PATIENTS: Adult patients with sensorineural hearing loss meeting the CI criteria who selected an Advanced Bionics CI. METHODS: Patients were randomized to CI surgery either with audible ECochG monitoring available to the surgeon during electrode insertion or without ECochG monitoring. Hearing preservation was determined by comparing preoperative unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to postoperative LF-PTA at CI activation. Pre- and post-CI computed tomography was used to determine electrode scalar location and electrode translocation. RESULTS: Eighty-five adult CI candidates were enrolled. The mean (standard deviation [SD]) unaided preoperative LF-PTA across the sample was 54 (17) dB HL. For the whole sample, hearing preservation was "good" (i.e., LF-PTA change 0-15 dB) in 34.5%, "fair" (i.e., LF-PTA change >15-29 dB) in 22.5%, and "poor" (i.e., LF-PTA change ≥30 dB) in 43%. For patients randomized to ECochG "on," mean (SD) LF-PTA change was 27 (20) dB compared with 27 (23) dB for patients randomized to ECochG "off" ( p = 0.89). Seven percent of patients, all of whom were randomized to ECochG off, showed electrode translocation from the scala tympani into the scala vestibuli. CONCLUSIONS: Although intracochlear ECochG during CI surgery has important prognostic utility, our data did not show significantly better hearing preservation in patients randomized to ECochG "on" compared with ECochG "off."


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Audiometría de Respuesta Evocada/métodos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Implantes Cocleares/efectos adversos , Audición , Humanos , Estudios Prospectivos
18.
PLoS One ; 16(11): e0260351, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34807938

RESUMEN

Eye movements measured by high precision eye-tracking technology represent a sensitive, objective, and non-invasive method to probe functional neural pathways. Oculomotor tests (e.g., saccades and smooth pursuit), tests that involve cognitive processing (e.g., antisaccade and predictive saccade), and reaction time tests have increasingly been showing utility in the diagnosis and monitoring of mild traumatic brain injury (mTBI) in research settings. Currently, the adoption of these tests into clinical practice is hampered by a lack of a normative data set. The goal of this study was to construct a normative database to be used as a reference for comparing patients' results. Oculomotor, cognitive, and reaction time tests were administered to male and female volunteers, aged 18-45, who were free of any neurological, vestibular disorders, or other head injuries. Tests were delivered using either a rotatory chair equipped with video-oculography goggles (VOG) or a portable virtual reality-like VOG goggle device with incorporated infrared eye-tracking technology. Statistical analysis revealed no effects of age on test metrics when participant data were divided into pediatric (i.e.,18-21 years, following FDA criteria) and adult (i.e., 21-45 years) groups. Gender (self-reported) had an effect on auditory reaction time, with males being faster than females. Pooled data were used to construct a normative database using 95% reference intervals (RI) with 90% confidence intervals on the upper and lower limits of the RI. The availability of these RIs readily allows clinicians to identify specific metrics that are deficient, therefore aiding in rapid triage, informing and monitoring treatment and/or rehabilitation protocols, and aiding in the return to duty/activity decision. This database is FDA cleared for use in clinical practice (K192186).


Asunto(s)
Movimientos Oculares , Tecnología de Seguimiento Ocular/instrumentación , Adolescente , Adulto , Cognición , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Reacción , Adulto Joven
19.
Laryngoscope Investig Otolaryngol ; 6(5): 1116-1127, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34667856

RESUMEN

OBJECTIVE: Eye tracking technology has been employed in assessing ocular motor and vestibular function following vestibular and neurologic conditions, including traumatic brain injury (TBI). Assessments include tests that provide visual and motion (rotation) stimuli while recording horizontal, vertical, and torsional eye movements. While some of these tests have shown diagnostic promise in previous studies, their use in clinical practice is limited by the lack of normative data. The goal of this study was to construct normative reference ranges to be used when comparing patients' results. METHODS: Optokinetic response, subjective visual horizontal and vertical, and rotation tests were administered to male and female volunteers, ages 18-45, who were free from neurological, vestibular disorders, or other head injuries. Tests were administered using either a rotatory chair or a portable virtual reality-like goggle equipped with video-oculography. RESULTS: Reference values for eye movements in response to different patterns of stimuli were analyzed from 290 to 449 participants. Analysis of gender (self-reported) or age when grouped as pediatric (late adolescent; 18-21 years of age) and adult (21-45 years of age) revealed no effects on the test metrics. Data were pooled and presented for each test metric as the 95% reference interval (RI) with 90% confidence intervals (CI) on upper and lower limits of the RI. CONCLUSIONS: This normative database can serve as a tool to aid in diagnosis, treatment, and/or rehabilitation protocols for vestibular and neurological conditions, including mild TBI (mTBI). This database has been cleared by the FDA for use in clinical practice (K192186). LEVEL OF EVIDENCE: 2b.

20.
Vaccine ; 39(41): 6019-6024, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34531078

RESUMEN

Influenza vaccination is widely advocated to avoid infection with influenza virus, a serious respiratory pathogen, and this was greatly emphasized during the raging COVID-19 epidemic. We conducted a study for baseline Flu specific immunity in a group of health care workers with documented past SARs-CoV-2 infection (designated COVID+) with mild or no symptoms and compared them with a control group that had not been infected with SARS CoV-2 (COVID-). Concurrently, we examined flu and SARS-CoV-2 specific T cell responses using the AIM (activation induced molecules) assay by flow cytometry. All COVID+ and 40% COVID- participants exhibited AIM responses to SARS-CoV-2 peptides, but only COVID+ were positive for SARs-CoV-2 antibody. Influenza HIN1 antigen specific CD4 T cells were found in 92% COVID+ and 76% COVID- participants and exhibited a strong direct correlation with SARS-CoV-2 specific CD4 T cells. This observation suggests that influenza specific T cell immunity may impact immune responses to SARS-CoV-2.


Asunto(s)
COVID-19 , Gripe Humana , Linfocitos T CD4-Positivos , Personal de Salud , Humanos , Gripe Humana/prevención & control , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...