Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-37471186

RESUMEN

Plane wave compounding (PWC) is widely used to measure the propagation of shear waves. Implementing PWC on most commercial ultrasound scanners is challenging because all channel (>128) data must be processed or transferred to the host computing unit in real time. Comb detection transmits multiple focused beams simultaneously and results in a reduced number of receive lines to be processed in parallel. These comb beams are scanned laterally to acquire receive lines at different lateral positions in order to obtain data over a large region of interest (ROI). One of the potential issues with using multiple simultaneously transmitted beams is the issue of crosstalk between the beams. Crosstalk is analyzed through simulated beam patterns, simulated B-mode images, and motion data from shear wave elastography (SWE) experiments. Using a Hamming window on transmit and receive can suppress crosstalk to 1.2% root-mean-square error (RMSE, normalized RMSE to the peak magnitude of the reference signal) for shear wave motion signals. Four comb beams with three laterally scanned locations cover almost the entire field of view (FOV) and achieve the same frame rate as PWC with three angles. Phantom and in vivo studies demonstrate comparable motion data of comb detection to PWC in terms of motion signal quality and measured phase velocity. In addition, comb detection provides motion with lower noise and stronger signals than PWC, which is believed to be due to the advantages of transmitting focused beams rather than plane waves (PWs).

2.
Ultrasound Med Biol ; 49(9): 1979-1995, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37357080

RESUMEN

OBJECTIVE: Osteochondritis dissecans (OCD) of the capitellum is a joint defect that is common among adolescent athletes. It is important to diagnose OCD as early as possible, because early-stage OCD lesions have a high rate of spontaneous healing with rest. Medical ultrasound could potentially be used as a screening tool for OCD but is limited by the use of delay-and-sum (DAS) reconstruction. In this study, we tested conventional delay-multiply-and-sum (DMAS) and novel low-pass DMAS reconstruction algorithms for better visualization of OCD lesions. METHODS: We created phantom and cadaveric OCD models that simulated a range of OCD lesion severities and stabilities. We also imaged an in vivo case of OCD in a patient study. In the reconstructed images, several profiles were taken to measure OCD lesion contrast, cartilage contrast, crack thickness error and bone interface clarity. RESULTS: In the phantom and cadaveric OCD models, we found that histogram-matched conventional DMAS reconstruction improved lesion contrast by up to 16%, cartilage contrast by 26% and bone interface clarity by 15% on average compared with DAS reconstruction. Histogram-matched low-pass DMAS reconstruction improved lesion contrast by up to 22%, cartilage contrast by 45%, and bone interface clarity by 29% on average compared with DAS reconstruction. In the in vivo case of OCD, we found that histogram-matched conventional and low-pass DMAS reconstruction improved lesion contrast by 22% and 26%, respectively. CONCLUSION: The application of DMAS reconstruction improved the ability of medical ultrasound to detect OCD lesions of the capitellum when compared with DAS reconstruction.


Asunto(s)
Articulación del Codo , Osteocondritis Disecante , Adolescente , Humanos , Osteocondritis Disecante/diagnóstico por imagen , Osteocondritis Disecante/cirugía , Ultrasonografía/métodos , Algoritmos , Fantasmas de Imagen , Cadáver , Articulación del Codo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA