1.
Health Phys ; 60(6): 789-96, 1991 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-2032833

RESUMEN

This paper describes a series of measurements and calculations that were undertaken at the Pacific Northwest Laboratory to determine the physical and dosimetric characteristics of a 137Cs source, which is housed within a commercially manufactured irradiator. These measurements and calculations helped to demonstrate that: (1) the exposure rate for this source was consistent with (traceable to) radiation standards maintained by the National Institute of Standards and Technology; (2) the radiation field at the surface of the irradiation phantom, in a 10 cm X 10 cm central area, was uniform to within +/- 2%; (3) the contribution of scattered photons was minimal; and (4) the ratio of the shallow to the deep dose equivalent was nearly unity. Because there are a number of similar irradiators in use, it is hoped that the methodology and results described in this paper will be of use to others.


Asunto(s)
Radioisótopos de Cesio , Dosis de Radiación , Radiometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA