Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Tokai J Exp Clin Med ; 46(1): 22-25, 2021 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-33835471

RESUMEN

OBJECTIVE: Anesthetic management of patients with giant mediastinal tumors is challenging from the perspective of both cardiovascular and respiratory management, and airway assessment is important for both concerns. We report the successful induction of general anesthesia and double-lumen tube intubation in the right lateral position for a patient with a giant mediastinal tumor with tracheal compression, using pre-operative chest radiograph imaging to minimize tracheal compression during induction. METHODS: A 41-year-old man required thoracoscopic giant superior mediastinal tumor resection. His trachea was compressed and displaced because of the tumor. Because preoperative chest radiography revealed that the tracheal diameter increased in the right lateral position, we chose this position for induction. RESULTS: Prompt and smooth intubation with a 35-Fr double-lumen tube (DLT) was achieved, and no adverse events associated with intubation were encountered. CONCLUSION: Safe and smooth induction with a DLT was performed owing to the perioperative chest radiograph imaging examination, which revealed the most advantageous position regarding minimal tracheal compression.


Asunto(s)
Anestesia General/métodos , Intubación Intratraqueal/métodos , Laringoscopía/métodos , Neoplasias del Mediastino/cirugía , Radiografía Torácica/métodos , Cirugía Asistida por Computador/métodos , Cirugía Torácica Asistida por Video/métodos , Toracoscopía/métodos , Adulto , Humanos , Masculino , Tráquea/diagnóstico por imagen , Tráquea/patología
2.
Tokai J Exp Clin Med ; 43(4): 139-142, 2018 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-30488400

RESUMEN

OBJECTIVE: Because of the shape of a double-lumen tube (DLT), it is more difficult to use for intubation than an ordinary endotracheal tube. We prospectively investigated the usefulness of the Airtraq DL® attached to the Universal Adapter for Smartphones® for DLT intubation. METHOD: At Tokai University Hachioji Hospital, anesthesiologists with ≥ 5 years' clinical experience intubated a tracheal intubation training mannequin with DLTs using the Airtraq DL® (Airtraq-alone phase) and the Airtraq DL® attached to the Universal Adapter for Smartphones® (adapter phase), and the time required was measured. RESULT: The mean time required for intubation was shorter in the adapter phase than in the Airtraq-alone phase for all anesthesiologists (adapter phase, 9.05±2.48 seconds; Airtraq-alone phase, 10.67±2.19 seconds). CONCLUSION: The use of Airtraq DL® a ttached to t he Universal Adapter for Smartphones® significantly reduced the time required for DLT intubation. Furthermore, the combination of these devices was found to be useful and safe for DLT intubation because they provide a significant amount of information on the area from the oral cavity to the opening of the trachea and have high educational value because their combined use allows several physicians to share imaging information.


Asunto(s)
Anestesiología/instrumentación , Intubación Intratraqueal/instrumentación , Laringoscopios , Maniquíes , Teléfono Inteligente , Diseño de Equipo , Humanos , Estudios Prospectivos , Factores de Tiempo , Grabación en Video
3.
Tokai J Exp Clin Med ; 43(4): 143-147, 2018 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-30488401

RESUMEN

OBJECTIVE: The Universal Adapter for Smartphones® c an record s till images and movies during intubation using the monitor display and recording functions of a smartphone. Here, we describe the successful use of the Airtraq Double Lumen® with the Universal Adapter for Smartphones® for airway management during anesthesia in a patient with intubation difficulty. METHODS: A 78-year-old man required thoracoscopic upper lobectomy for a pulmonary tumor. Preoperative examination revealed micrognathia, mouth opening equivalent to a three-finger width, Mallampati Class II, mentum-hyoid bone distance equal to a 2.5-finger width, hyoid bone-thyroid cartilage distance equal to a two-finger width, and Class I findings in the Upper Lip Bite Test. After inducing anesthesia and confirming the feasibility of mask ventilation, we administered 70 mg of rocuronium and inserted the Airtraq Double Lumen®. The Universal Adapter for Smartphones® connected to a 4-inch iPod Touch® was attached to its eye cup, through which the iPod Touch displayed images for easy visualization of the glottal area. RESULTS: Prompt and smooth intubation with a 35-Fr double-lumen tube (DLT) was achieved. There were no adverse events associated with intubation. CONCLUSION: Combination of the Universal Adapter for Smartphones® and the Airtraq Double Lumen® can facilitate smooth tracheal intubation with a DLT in cases of difficult intubation.


Asunto(s)
Manejo de la Vía Aérea/instrumentación , Anestesiología/instrumentación , Intubación Intratraqueal/instrumentación , Teléfono Inteligente , Anciano , Humanos , Intubación Intratraqueal/métodos , Neoplasias Pulmonares/cirugía , Masculino , Neumonectomía , Grabación en Video
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...