Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Sep Sci ; 47(11): e2400181, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38863110

RESUMEN

Topotecan (TPT) is used in the treatment of retinoblastoma, the most common malignant intraocular tumor in children. TPT undergoes pH-dependent hydrolysis of the lactone ring to the ring-opened carboxylate form, with the lactone form showing antitumor activity. A selective, and highly sensitive ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed for the determination of both forms of TPT in one mobile phase composition in plasma and vitreous humor matrices. The method showed an excellent linear range of 0.375-120 ng/mL for the lactone. For the carboxylate, the linear range was from 0.75 to 120 ng/mL. The matrix effect and the recovery for the lactone ranged from 98.5% to 106.0% in both matrices, for the carboxylate form, it ranged from 94.9% to 101.2%. The dynamics of the transition between TPT lactone and TPT carboxylate were evaluated at different pH environments. The stability of TPT forms was assessed in plasma and vitreous humor at 8 and 37°C and a very fast conversion of lactone to carboxylate form occurred at 37°C in both matrices. The method developed facilitates the investigation of TPT pharmacodynamics and the release kinetics in the development of the innovative local drug delivery systems.


Asunto(s)
Lactonas , Espectrometría de Masas en Tándem , Topotecan , Cuerpo Vítreo , Cromatografía Líquida de Alta Presión , Lactonas/química , Lactonas/análisis , Cuerpo Vítreo/química , Topotecan/química , Topotecan/análisis , Humanos , Ácidos Carboxílicos/química , Ácidos Carboxílicos/análisis , Estructura Molecular
2.
Ecotoxicol Environ Saf ; 280: 116528, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38820821

RESUMEN

Effective removal of organic UV filters from aquatic environmental compartments and swimming waters is very important because these substances are hazardous to humans and wildlife at low concentrations and act as endocrine disruptors. Therefore, the aim of the present article is to determine the extraction efficiencies of hydrophobic deep eutectic solvents (HDES) for the selected UV filters based on benzophenone structure (benzophenone, 2,4-dihydroxybenzophenone, 2,2´,4,4´-tetrahydroxybenzophenone, 2-hydroxy-4-methoxybenzophenone, 2,2´-dihydroxy-4-methoxybenzophenone, 4-methacryloxy-2-hydroxybenzophenone) from aqueous matrices. For this purpose, six HDESs based on dl-menthol in combination with caprylic, decanoic and lauric acid are prepared and compared with referent terpene solvents such as terpineol and linalool. The effect of various parameters such as HDES composition, volume ratio, frequency and shaking time are studied. The highest extraction efficiency is shown by HDES of menthol:caprylic acid (1:1) composition at the aqueous:organic phase volume ratio of 1:1, shaking frequency of 1500 rpm and shaking time of 15 min. The achieved extraction efficiencies are higher than 99.6 % for all benzophenones studied in the purification of stagnant pond water, swimming pool water and river water samples. After a simple and fast sample treatment, the residual levels of benzophenones in the waters are controlled by a newly developed sensitive HPLC-MS/MS method with LOQs in the range of 0.7 - 5.0 ng/mL.


Asunto(s)
Benzofenonas , Disolventes Eutécticos Profundos , Interacciones Hidrofóbicas e Hidrofílicas , Protectores Solares , Contaminantes Químicos del Agua , Purificación del Agua , Benzofenonas/química , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química , Protectores Solares/química , Protectores Solares/toxicidad , Purificación del Agua/métodos , Disolventes Eutécticos Profundos/química , Mentol/química , Caprilatos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...