Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int Endod J ; 54(9): 1614-1622, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33527449

RESUMEN

AIM: To evaluate how different rotational speeds affect the torque/force generation and shaping ability of rotary root canal instrumentation using JIZAI (MANI, Utsunomiya, Japan) nickel-titanium instruments in continuous rotation and optimum torque reverse (OTR) motion. METHODOLOGY: Mesial root canals of extracted mandibular molars were instrumented up to size 25, 0.04 taper using JIZAI instruments, and anatomically matched canals were selected based on geometric features of the canal [canal volume (mm3 ), surface area (mm2 ), length, 15°-20° curvature and radius of curvature (4-8 mm)] after micro-computed tomographic scanning. An automated root canal instrumentation and torque/force analysing device was programmed to permit a simulated pecking motion (2 s downward and 1 s upward at 50 mm min-1 ). The selected canals were prepared with size 25, 0.06 taper JIZAI instruments using continuous rotation or OTR motion and further subdivided according to the rotational speed (300 or 500 rpm, n = 10 each). Real-time clockwise/counterclockwise torque and downward/upward force were recorded using a custom-made torque/force analysing device. Then, the registered pre- and post-operative micro-computed tomographic datasets were examined to evaluate the canal volume changes and centring ratios at 1, 3, 5 and 7 mm from the apical foramen. Data were analysed using two-way analysis of variance or the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction (α = 5%). RESULTS: Maximum upward force and clockwise torque were significantly smaller in 500 rpm groups than in 300 rpm groups (P < .05); however, no significant difference was found between continuous rotation and OTR motion (P > .05). OTR motion developed higher maximum counterclockwise torque than continuous rotation (P < .05). Maximum downward force, canal volume changes and centring ratios were not significantly different among all groups (P > .05). There was no file fracture in any of the groups. CONCLUSIONS: Under laboratory conditions using JIZAI instruments, a rotational speed of 500 rpm generated significantly lower maximum screw-in forces and torque values than rotational speed of 300 rpm. Continuous rotation and OTR motion performed similarly in shaping the canals.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Aleaciones Dentales , Cavidad Pulpar/diagnóstico por imagen , Diseño de Equipo , Humanos , Rotación , Titanio , Torque
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...