1.
Int J Paediatr Dent ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570933

RESUMEN

BACKGROUND: Children with dental caries are treated with stainless steel metal crowns (SSC), but the aesthetics and precision still need to be improved. Currently, both 3D-printed resin crowns (PRC) and computer-aided design/computer-aided manufacture (CAD/CAM) resin crowns (CRC) meet the clinical requirements for crown applications in terms of strength, production time, cost, and aesthetics. AIM: This study replaced SSC with customized resin crowns by 3D printing and CAD/CAM. DESIGN: In this study, PRC, CRC, and SSC were used for incisor and molar restorations, and 60 crowns were made with 10 for each group. The fabrication efficiency, surface characteristics, marginal fit, and stability of the two different crowns were evaluated. RESULTS: PRC and CRC show superior color and surface characteristics, though production times are longer (5.3-12.4 times and 3.3-9.1 times, respectively) than for SSC (p < .05). They, however, can be completed within 80 min. Edge gaps for PRC and CRC are significantly lower (13.0-19.2 times and 13.0-13.7 times) than for SSC (p < .05). All materials exhibit good stability. CONCLUSION: The 3D-PRCs and CAD/CAM resin crowns may replace SSCs as a potential choice for clinical child caries.

2.
J Dent Sci ; 19(1): 542-549, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38303893

RESUMEN

Background/purpose: Producing tooth crowns through dental technology is a basic function of dentistry. The morphology of tooth crowns is the most important parameter for evaluating its acceptability. The procedures were divided into four steps: tooth collection, scanning skills, use of mathematical methods and software, and machine learning calculation. Materials and methods: Dental plaster rods were prepared. The effective data collected were to classify 121 teeth (15th tooth position), 342 teeth (16th tooth position), 69 teeth (21st tooth position), and 89 teeth (43rd tooth position), for a total of 621 teeth. The procedures are divided into four steps: tooth collection, scanning skills, use of mathematical methods and software, and machine learning calculation. Results: The area under the curve (AUC) value was 0, 0.5, and 0.72 in this study. The precision rate and recall rate of micro-averaging/macro-averaging were 0.75/0.73 and 0.75/0.72. If we took a newly carved tooth picture into the program, the current effectiveness of machine learning was about 70%-75% to evaluate the quality of tooth morphology. Through the calculation and analysis of the two different concepts of micro-average/macro-average and AUC, similar values could be obtained. Conclusion: This study established a set of procedures that can judge the quality of hand-carved plaster sticks and teeth, and the accuracy rate is about 70%-75%. It is expected that this process can be used to assist dental technicians in judging the pros and cons of hand-carved plaster sticks and teeth, so as to help dental technicians to learn the tooth morphology more effectively.

3.
J Prosthodont Res ; 68(2): 319-325, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37574275

RESUMEN

PURPOSE: Polyetheretherketone (PEEK) is a new polymeric material that has received significant attention in dentistry because of its mechanical properties, biocompatibility, and aesthetics. However, the bonding performance of PEEK to other materials is not preferable. This study aimed to analyze the variations in the surface characteristics of PEEK under the chemical action of primers containing different functional monomers or polymers and to evaluate the bonding performance of PEEK and dental cement. METHODS: Disk-shaped PEEK samples were prepared by dental milling, blasting with alumina oxide, and covering with primers containing functional monomers or polymers. The surface characteristics of the samples were analyzed by microscopy and spectroscopy. The shear bond strength (SBS) between PEEK and dental cement, with and without thermocycling, was tested using a universal testing machine. Finally, the data were statistically analyzed and compared. RESULTS: Functional monomers or polymers were successfully bonded to the surface of PEEK. This treatment significantly improved its hydrophilicity and surface free energy (P < 0.05). The primer containing pentaerythritol triacrylate had the highest SBS without thermocycling (13.89 MPa). Meanwhile, the primers containing urethane dimethacrylate (UDMA) and methyl methacrylate (MMA) (abbreviated as the HC group) showed the highest SBS and lowest reduction (25.51%) after thermocycling. Notably, all the testing groups achieved the ISO10477 standard of 5 MPa. After thermocycling, adhesive failure accounted for the largest proportion of failures in all the groups except the HC group. CONCLUSIONS: The chemical priming treatment can significantly improve the SBS of PEEK and dental cement. Moreover, a primer containing both UDMA and MMA can provide improved bonding for PEEK materials.


Asunto(s)
Recubrimiento Dental Adhesivo , Metacrilatos , Poliuretanos , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Polímeros , Benzofenonas , Polietilenglicoles , Cetonas , Propiedades de Superficie , Ensayo de Materiales , Resistencia al Corte , Análisis del Estrés Dental
4.
Polymers (Basel) ; 14(7)2022 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-35406340

RESUMEN

In this study, we designed and fabricated transmission parts for a flapping-wing micro-aerial vehicle (FW-MAV), which was fabricated by precision injection molding, and analyzed its warpage phenomena. First, a numerical simulation (Moldflow) was used to analyze the runner balance and temperature, pressure, and stress distributions of the base, gears, and linkage of the transmission structures in an FW-MAV. These data were then applied to fabricate a steel mold for an FW-MAV. Various process parameters (i.e., injection temperature, mold temperature, injection pressure, and packing time) for manufacturing transmission parts for the FW-MAV by precision injection molding were compared. The Taguchi method was employed to determine causes of warpage in the transmission parts. The experimental results revealed that the causes of warpage in the transmission parts were, in order of importance, the mold temperature, injection pressure, packing time, and injection temperature. After the transmission parts were assembled on the FW-MAV, experiments revealed that the MAV could achieve a flight time of 180 s. Mass production of the FW-MAV by precision injection molding could potentially produce substantial savings in time, manpower, and cost.

5.
J Prosthet Dent ; 127(1): 122-127, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33223197

RESUMEN

STATEMENT OF PROBLEM: Although studies have reported on selective laser melting (SLM)-fabricated removable partial dentures (RPDs), research addressing the trueness of SLM-fabricated RPD metal frameworks is sparse. PURPOSE: The purpose of this in vitro study was to evaluate the trueness of powdered cobalt-chromium (Co-Cr) or titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy frameworks for RPDs fabricated by SLM. MATERIAL AND METHODS: A digital scan of a Kennedy class II mandible typodont was obtained to design an RPD framework by using a computer-aided design (CAD) software program (denoted as CRF). Two experimental groups of frameworks were fabricated from the CRF by using SLM in alloys of Co-Cr (SLM-Co-Cr, n=6) and in Ti-6Al-4V (SLM-Ti-6Al-4V, n=6) while a control group was fabricated by using traditional lost-wax casting following stereolithography (CA-Co-Cr, n=6). In total, 18 RPD frameworks were digitally scanned (denoted as CRF), with each scan then superimposed on the CRF and evaluated for discrepancies by using a 3D analysis software program. A nonparametric Kruskal-Wallis test was performed to determine differences in trueness among groups (α=.05). RESULTS: The CA-Co-Cr group showed the highest discrepancy between CEF and CRF. Statistically significant differences were found between the CA-Co-Cr and SLM-fabricated groups (P=.03 for Co-Cr, and P=.016 for Ti-6Al-4V). However, no significant difference was found between the SLM-Co-Cr and SLM-Ti-6Al-4V groups (P=.787). CONCLUSIONS: SLM-fabricated RPD frameworks exhibited higher trueness than CA-Co-Cr fabricated ones, indicating the potential of selective laser melting to produce the geometric shapes required for accurate dental restorations.


Asunto(s)
Dentadura Parcial Removible , Aleaciones de Cromo , Diseño Asistido por Computadora , Aleaciones Dentales , Congelación , Rayos Láser , Titanio
6.
Materials (Basel) ; 13(3)2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32046015

RESUMEN

Porphyromonas gingivalis infection is one of the causes of implant failures, which can lead to peri-implantitis. Implant surface roughness is reportedly related strongly to P. gingivalis adhesion, which can lead to peri-implantitis and, later, cell adhesion. Our aim was to evaluate the effects of Er,Cr:YSGG laser on titanium (Ti) disc surfaces and its interaction with bacterial adhesion and fibroblast viability. Ti discs underwent two treatments: autoclaving (control) and erbium, chromium-doped yttrium scandium gallium garnet (Er,Cr:YSGG) laser treatment (test). Ti disc surfaces were examined with scanning electronic microscope (SEM), Energy-dispersive spectrometry (EDX), X-ray photoelectron spectroscopy (XPS). The surface roughness same as wettability were also investigated. Fibroblast viability was assessed with the water-soluble tetrazolium 1 (WST-1) test, and osteoblast differentiation was assessed with the alkaline phosphatase (ALP) assay. Bacterial structure and colony formation were detected with scanning electron microscopy and Gram stain. In comparison to control discs, the test discs showed smoother surfaces, with 0.25-µm decrease in surface roughness (p < 0.05); lower P. gingivalis adhesion (p < 0.01); less P. gingivalis colonization (p < 0.05); and increased fibroblast viability and osteoblast differentiation (p < 0.05). Er,Cr:YSGG laser treatment improved disc surfaces by making them slightly smoother, which reduced P. gingivalis adhesion and increased fibroblast viability and osteoblast differentiation. Er,Cr:YSGG laser treatment can be considered a good option for managing peri-implantitis. Further investigations of laser-assisted therapy are necessary for better guidelines in the treatment of peri-implantitis.

8.
Micromachines (Basel) ; 10(7)2019 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-31262083

RESUMEN

In this paper, we fabricate a surface acoustic wave (SAW) device with micro-structures on a zinc oxide (ZnO) thin film and measure its signal response. The manufacturing processes of the SAW device include the fabrication of micro-structures of a SAW element and its interdigital transducer by silicon micro-machining and the fabrication of a thin film of ZnO by RF magnetron sputtering. We, then, measure the SAW properties. This research investigates the properties of sputtered thin films for various amounts of O2/(Ar + O2) using Zn and ZnO targets. Regardless of target, the growth rate of the ZnO thin film decreases as the oxygen content increases. When the SAW is sputtered ZnO thin film using 30% oxygen, the digital signal of the SAW has better performance. The measurement signal of the SAW with micro-structures is similar to that without micro-structures.

9.
Materials (Basel) ; 11(10)2018 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-30287747

RESUMEN

Calcium phosphate ceramics used in dentistry and orthopedics are some of the most valuable biomaterials, owing to their excellent osteoconduction, osteoinduction, and osseointegration. Osteoconduction and osteoinduction are critical targets for bone regeneration, and osseointegration is essential for any dental implantations. In this study, a hydroxyapatite (HAp) hybrid coating layer with the sequential release of bone morphogenetic protein 2 (BMP-2) was deposited onto an etched titanium substrate by electrochemical deposition. The resulting release of BMP-2 from Ti⁻HAp was assessed by immersing samples in a simulated buffer fluid solution. Through coculture, human osteosarcoma cell proliferation and alkaline phosphatase activity were assessed. The characteristics and effect on cell proliferation of the hybrid coatings were investigated for their functionality through X-ray diffraction (XRD) and cell proliferation assays. Findings revealed that -0.8 V vs. Ag/AgCl (3 M KCl) exhibited the optimal HAp properties and a successfully coated HAp layer. XRD confirmed the crystallinity of the deposited HAp on the titanium surface. Ti-0.8 V Ti⁻HAp co-coating BMP sample exhibited the highest cell proliferation efficiency and was more favorable for cell growth. A successful biocompatible hybrid coating with optimized redox voltage enhanced the osseointegration process. The findings suggest that this technique could have promising clinical applications to enhance the healing times and success rates of dental implantation.