Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 14(7)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38611585

RESUMEN

BACKGROUND AND OBJECTIVE: The dynamic assessment of disease activity during the follow-up of patients with Crohn's disease (CD) remains a significant challenge. In this study, we aimed to identify the role of dynamic contrast-enhanced ultrasound (DCE-US) in the evaluation of activity of CD. METHODS: In the retrospective study, patients diagnosed with CD in our hospital were included. All the diagnoses were confirmed by clinical symptoms and ileocolonoscopical results. All patients underwent intestinal ultrasound and contrast-enhanced ultrasound (CEUS) examinations within 1 week of the ileocolonoscopy examinations. Acuson Sequoia (Siemens Healthineers, Mountain View, CA, USA) and Resona R9 Elite (Mindray Medical Systems, China) with curved array and Line array transducers were used. The CEUS examination was performed with SonoVue (Bracco SpA, Milan, Italy). DCE-US analysis was performed by UltraOffice (version: 0.3-2010, Mindray Medical Systems, China) software. Two regions of interest (ROIs) were set in the anterior section of the infected bowel wall and its surrounding normal bowel wall 2 cm distant from the inflamed area. Time-intensity curves (TICs) were generated and quantitative perfusion parameters were obtained after curve fittings. The Simple Endoscopic Score for Crohn's disease (SES-CD) was regarded as the reference standard to evaluate the activity of CD. The receiver operating characteristic curve (ROC) analyses were used to determine the diagnostic efficiency of DCE-US quantitative parameters. RESULTS: From March 2023 to November 2023, 52 CD patients were included. According to SES-CD score, all patients were divided into active group with the SES-CD score > 5 (n = 39) and inactive group SES-CD score < 5 (n = 13). Most of the active CD patients showed bowel wall thickness (BWT) > 4.2 mm (97.4%, 38/39) or mesenteric fat hypertrophy (MFH) on intestinal ultrasound (US) scan (69.2%, 27/39). Color Doppler signal of the bowel wall mostly showed spotty or short striped blood flow signal in active CD patients (56.4%, 22/39). According to CEUS enhancement patterns, most active CD patients showed a complete hyperenhancement of the entire intestinal wall (61.5%, 24/39). The TICs of active CD showed an earlier enhancement, higher peak intensity, and faster decline. Among all CEUS quantitative parameters, amplitude-derived parameters peak enhancement (PE), wash-in area under the curve (WiAUC), wash-in rate (WiR), wash-in perfusion index (WiPI), and wash-out rate (WoR) were significantly higher in active CD than in inactive CD (p < 0.05). The combined AUROC of intestinal ultrasound features and DCE-US quantitative perfusion parameters in the diagnosis of active CD was 0.987, with 97.4% sensitivity, 100% specificity, and 98.1% accuracy. CONCLUSIONS: DCE-US with quantitative perfusion parameters is a potential useful noninvasive imaging method to evaluate the activity of Crohn's disease.

2.
Clin Hemorheol Microcirc ; 86(1-2): 51-61, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37638422

RESUMEN

OBJECTIVES: To explore the technical and clinical evaluation of ultrasound-derived fat fraction (UDFF) measurement in adult patients in whom fatty liver was suspected. MATERIALS AND METHODS: In this prospective study, 41 participants were initially enrolled in our hospital between October 2022 and December 2022 and received UDFF assessment using Siemens ACUSON Sequoia system equipped with DAX transducer. UDFF measurement was performed three times to obtain UDFF values from each imaging location (V hepatic segment and VIII hepatic segment) per participant, and the depth (skin-to-capsule distance) was automatically measured. The echogenicity of liver tissue in B mode ultrasound (BMUS) was compared to the normal kidney tissue, and fatty liver was graded as mild (Grade 1), moderate (Grade 2), and severe (Grade 3). The median of the acquired overall median UDFF values was used for statistical analysis. All ultrasound examinations were performed by one of two radiologists (with 20 and 10 years of liver ultrasound imaging experience). RESULTS: Finally, UDFF measurement was successfully performed on 38 participants to obtain valid values, including 21 men with a median age of 40.0 years (interquartile range [IQR]: 23.0 - 58.5) and 17 women with a median age of 60.0 years (IQR: 29.5 - 67.0). Fatty liver was diagnosed by BMUS features in 47.4% (18/38) participants. Among all participants, the median UDFF value was 7.0% (IQR: 4.0 - 15.6). A significant difference in UDFF values was found between participants with fatty liver and without fatty liver (U = 7.0, P < 0.001), and UDFF values elevated as the grade of the fatty liver increased (P < 0.001). The median UDFF values from the three UDFF measurements obtained during each ultrasound examination showed excellent agreement (ICC = 0.882 [95% confidence interval: 0.833 - 0.919]). The Spearman correlation of UDFF values in different depths was moderate, with a rs value of 0.546 (P < 0.001). No significant differences in UDFF values were found between V hepatic segment and VIII hepatic segment (U = 684.5, P = 0.697). CONCLUSIONS: UDFF provides a novel non-invasive imaging tool for hepatic steatosis assessment with excellent feasibility.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Masculino , Adulto , Humanos , Femenino , Adulto Joven , Persona de Mediana Edad , Estudios Prospectivos , Hígado/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Ultrasonografía/métodos , Imagen por Resonancia Magnética/métodos
3.
Clin Hemorheol Microcirc ; 86(3): 313-326, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37927251

RESUMEN

OBJECTIVES: To evaluate the efficacy of the radiomics model based on preoperative B-mode ultrasound (BMUS) and shear wave elastography (SWE) for predicting the occurrence of clinically relevant-postoperative pancreatic fistula (CR-POPF). METHODS: Patients who were scheduled to undergo pancreatectomy were prospectively enrolled and received ultrasound assessment within one week before surgery. The risk factors of POPF (grades B and grades C) were analyzed. Preoperative BMUS images, SWE values of pancreatic lesions and surrounding parenchyma were used to build preoperative prediction radiomics models. Radiomic signatures were extracted and constructed using a minimal Redundancy Maximal Relevance (mRMR) algorithm and an L1 penalized logistic regression. A combined model was built using multivariate regression which incorporated radiomics signatures and clinical data. RESULTS: From January 2020 to November 2021, a total of 147 patients (85 distal pancreatectomies and 62 pancreaticoduodenectomies) were enrolled. During the three-week follow-up after pancreatectomy, the incidence rates of grade B/C POPF were 28.6% (42/147). Radiomic signatures constructed from BMUS of pancreas parenchymal regions (panRS) achieved an area under the receiver operating characteristic curve (AUC) of 0.75, accuracy of 68.7%, sensitivity of 85.7 %, and specificity of 61.9 % in preoperative noninvasive prediction of CR-POPF. The AUC of the radiomics model increased to 0.81 when panRS was used for the prediction of CR-POPF after pancreaticoduodenectomy. CONCLUSIONS: Radiomics model based on ultrasound images was potentially useful for predicting CR-POPF. Patients with high-risk factors should be closely monitored when postoperation.


Asunto(s)
Pancreatectomía , Fístula Pancreática , Humanos , Pancreatectomía/efectos adversos , Fístula Pancreática/etiología , Fístula Pancreática/complicaciones , Radiómica , Páncreas/diagnóstico por imagen , Páncreas/cirugía , Pancreaticoduodenectomía/efectos adversos , Factores de Riesgo , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/patología , Estudios Retrospectivos
4.
Ultrasound Med Biol ; 50(1): 39-46, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37778901

RESUMEN

OBJECTIVE: The aim of the work described here was to evaluate the impact of hepatocellular carcinoma (HCC) tumor size on Sonazoid contrast-enhanced ultrasound (CEUS) enhancement features, especially in tumors with diameters ≤30 mm and <10 mm. METHODS: In this retrospective study, we included patients with histopathologically confirmed HCC lesions and divided them into three groups on the basis of tumor size. All patients underwent Sonazoid-enhanced CEUS examinations before surgery. B-mode ultrasound (BMUS) features and CEUS enhancement patterns were evaluated according to current World Federation for Ultrasound in Medicine and Biology Guidelines criteria. The χ2- and Student t-tests were used to compare differences between groups. RESULTS: We included 132 patients with histopathologically confirmed HCC lesions from November 2020 to September 2022. On the basis of tumor size, patients were divided into group 1 (<10 mm, n = 5), group 2 (10-30 mm, n = 54) and group 3 (>30 mm, n = 73). On BMUS, most HCCs appeared heterogeneous but predominantly hypo-echoic (61.4%, 81/132) with ill-defined margins and irregular shapes. Meanwhile, iso-echoic features were more common in small HCCs ≤30 mm (15.3%, 9/59), but a mixed hyper- and hypo-echoic appearance was more common in HCCs >30 mm (17.8%, 13/73) (p = 0.003). On Sonazoid-enhanced CEUS, all HCCs presented arterial phase hyperenhancement (APHE) (100.0%, 132/132). Most HCCs >30 mm exhibited heterogeneous hyperenhancement (86.3%, 63/73), whereas nearly one-third of small HCCs ≤30 mm exhibited homogeneous hyperenhancement (35.6%, 21/59) (p = 0.003). In the portal venous phase, there was a significantly higher proportion of washout in HCCs >30 mm (84.9%, 62/73) than in small HCCs ≤30 mm (64.4%, 38/59) (p = 0.006). During the Kupffer phase, 11 additional hypo-enhanced lesions (mean size: 14.1 ± 4.1 mm, iso-echoic on BMUS), which were also suspected to be HCC lesions, were detected in 5 patients with small HCCs ≤30 mm and 4 patients with HCCs >30 mm. All 5 cases of HCCs <10 mm exhibited APHE and late washout (>60 s). The majority (3/5, 60%) exhibited washout in the portal venous phase (70, 74 and 75 s), one case did so in the late phase (125 s) and another in the Kupffer phase (420 s). CONCLUSION: Tumor size had a significant impact on the washout features of HCC lesions on Sonazoid-enhanced CEUS. Small HCC lesions ≤30 mm had a higher proportion of relatively late washout in comparison to larger lesions. Sonazoid-enhanced CEUS might be helpful in the detection and characterization of HCC lesions <10 mm.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Medios de Contraste , Ultrasonografía
5.
Diagnostics (Basel) ; 13(23)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38066809

RESUMEN

Malignant focal liver lesions (FLLs) are commonly reported in adults but rarely seen in the pediatric population. Due to the rarity, the understanding of these diseases is still very limited. In children, most malignant FLLs are congenital. It is very important to choose appropriate imaging examination concerning various factors. This paper will outline common pediatric malignant FLLs, including hepatoblastoma, hepatocellular carcinoma, and cholangiocarcinoma and discuss them against the background of the latest knowledge on comparable/similar tumors in adults. Medical imaging features are of vital importance for the non-invasive diagnosis and follow-up of treatment of FLLs in pediatric patients. The use of CEUS in pediatric patients for characterizing those FLLs that remain indeterminate on conventional B mode ultrasounds may be an effective option in the future and has great potential to be integrated into imaging algorithms without the risk of exposure to ionizing radiation.

6.
Diagnostics (Basel) ; 13(24)2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38132242

RESUMEN

Malignant focal liver lesions (FLLs) represent various kinds of epithelial and mesenchymal tumors. In pediatric patients, the understanding of pediatric liver diseases and associated imaging manifestations is essential for making accurate diagnosis and differential diagnosis. This paper will discuss the latest knowledge of the common pediatric malignant FLLs, including undifferentiated embryonal sarcoma, rhabdomyosarcoma, epithelioid hemangioendothelioma, angiosarcoma, and malignant rhabdoid tumor. Medical imaging features are not only helpful for clinical diagnosis, but can also be useful in the evaluation and follow-up of pre- and post-treatment. The future perspectives of contrast-enhanced ultrasound (CEUS) enhancement patterns of FLLs in pediatric patients are also mentioned.

7.
Front Bioeng Biotechnol ; 11: 1209294, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37555078

RESUMEN

Polyurethanes and plastics have become ubiquitous in modern society, finding use in a wide variety of applications such as clothing, automobiles, and shoes. While these materials provide numerous benefits to human life, their persistence in the environment has caused ecological imbalances. Therefore, new processes are needed to make these materials more sustainable and re-usable. In 2011, Ludwik Leibler introduced a new class of covalent adaptable network (CAN) polymers called Vitrimers. Vitrimers possess self-repairing properties and are capable of being reprocessed due to dynamic exchange or breaking/recombination of covalent bonds, similar to thermoset materials. This study explores the synthesis of Vitrimers using waste polyurethane or plastics as feedstock. The raw materials were glycolysed to obtain the glycolysate, which was then used as a reagent for the Vitrimers synthesis. The main objective of this study was to achieve the maximum self-repairable rate of the prepared sample. The Taguchi orthogonal analysis was employed to guide the experiments. The optimized experimental conditions for polyurethane glycolysis were determined to be under ethylene glycol and catalyzed by sodium hydroxide at 180°C for 1 h, resulting in the highest hydroxyl concentration in the glycolysate. In the second stage of the experiment, the ratio of hexamethylene diisocyanate (HDI) to solvent was set to 2, HDI trimer to solvent was 2, and PGE/glycolysate was 0.5, with equal amounts of PEG and glycolysate used as the solvent. The reaction was carried out at 80°C for 1 h, achieving a self-repair ability of 47.5% in the prepared sample. The results of this study show that waste polyurethane or plastics can be effectively recycled and transformed into vitrimers with self-repairing properties. The use of glycolysis as a feedstock is a promising method for the sustainable recycling of polyurethane waste. The Taguchi orthogonal analysis is an effective approach for optimizing experimental conditions and improving the reproducibility of the results.

8.
Acad Radiol ; 30 Suppl 1: S155-S163, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37407373

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate the performance of attenuation imaging (ATI) based on ultrasound for detection of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD). MATERIALS AND METHODS: This prospective study was approved by our institutional review board (B2021-092R). Written informed consent was obtained from all patients. This study included 60 patients who had clinical suspicion of NAFLD and were referred for liver biopsy after ATI and controlled attenuation parameter (CAP) examinations between September 2020 and December 2021. The histologic hepatic steatosis was graded. The area under curve (AUC) analysis was performed. RESULTS: The success rate of the ATI examination was 100%. The intraobserver reproducibility of ATI was 0.981. The AUCs of ATI for detecting ≥S1, ≥S2, and S3 were 0.968 (cut-off value of 0.671 dB/cm/MHz), 0.911 (cut-off value of 0.726 dB/cm/MHz), and 0.766 (cut-off value of 0.757 dB/cm/MHz), respectively. The AUCs of CAP for detecting ≥S1, ≥S2, and S3 were 0.916 (cut-off value of 258.5 dB/m), 0.872 (cut-off value of 300.0 dB/m), and 0.807 (cut-off value of 315.0 dB/m), respectively. The diagnostic values showed no significant difference between ATI and CAP in detecting ≥S1, ≥S2, and S3 (P = .281, P = .254, and P = .330, respectively). The ATI had significant correlations with high-density lipoprotein cholesterol (P < .001), and with triglycerides (P = .015). CONCLUSION: ATI showed good feasibility and diagnostic performance in the detection of varying degrees of hepatic steatosis in NAFLD patients.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Hígado/diagnóstico por imagen , Hígado/patología , Estudios Prospectivos , Reproducibilidad de los Resultados , Diagnóstico por Imagen de Elasticidad/métodos , Curva ROC , Biopsia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...