Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Eur J Anaesthesiol ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38323332

RESUMEN

BACKGROUND: Induction of general anaesthesia has many potential triggers for peri-operative myocardial ischaemia including the acute disturbance of blood gases that frequently follows alterations in breathing and ventilation patterns. Free-breathing oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging may provide the opportunity to continuously quantify the impact of such triggers on myocardial oxygenation. OBJECTIVE: To investigate the impact of breathing patterns that simulate induction of general anaesthesia on myocardial oxygenation in awake healthy adults using continuous OS-CMR imaging. DESIGN: Prospective observational study. SETTING: Single-centre university hospital. Recruitment from August 2020 to January 2022. PARTICIPANTS: Thirty-two healthy volunteers younger than 45 years old were recruited. Data were analysed from n = 29 (69% male individuals). INTERVENTION: Participants performed a simulated induction breathing manoeuvre consisting of 2.5 min paced breathing with a respiration rate of 14 breaths per minute, followed by 5 deep breaths, then apnoea for up to 60s inside a magnetic resonance imaging scanner (MRI). Cardiac images were acquired with the traditional OS-CMR sequence (OSbh-cine), which requires apnoea for acquisition and with two free-breathing OS-CMR sequences: a high-resolution single-shot sequence (OSfb-ss) and a real-time cine sequence (OSfb-rtcine). MAIN OUTCOME MEASURES: Myocardial oxygenation response at the end of the paced breathing period and at the 30 s timepoint during the subsequent apnoea, reflecting the time of successful intubation in a clinical setting. RESULTS: The paced breathing followed by five deep breaths significantly reduced myocardial oxygenation, which was observed with all three techniques (OSbh-cine -6.0 ±â€Š2.6%, OSfb-ss -12.0 ±â€Š5.9%, OSfb-rtcine -5.4 ±â€Š7.0%, all P < 0.05). The subsequent vasodilating stimulus of apnoea then significantly increased myocardial oxygenation (OSbh-cine 6.8 ±â€Š3.1%, OSfb-ss 8.4 ±â€Š5.6%, OSfb-rtcine 15.7 ±â€Š10.0%, all P < 0.01). The free-breathing sequences were reproducible and were not inferior to the original sequence for any stage. CONCLUSION: Breathing manoeuvres simulating induction of general anaesthesia cause dynamic alterations of myocardial oxygenation in young volunteers, which can be quantified continuously with free-breathing OS-CMR. Introducing these new imaging techniques into peri-operative studies may throw new light into the mechanisms of peri-operative perturbations of myocardial tissue oxygenation and ischaemia. VISUALABSTRACT: http://links.lww.com/EJA/A922.

2.
Eur Radiol ; 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37870625

RESUMEN

OBJECTIVES: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN). METHODS: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared. The cohort was divided into a low-, medium-, and high-risk group based on the respective LCP scores; shifts between the groups were studied to evaluate the potential impact on nodule management. Two different malignancy risk score thresholds were analyzed: a higher threshold of ≥ 9 ("rule-in" approach) and a lower threshold of > 4 ("rule-out" approach). RESULTS: In total, 169 patients with 196 nodules could be included (mean age ± SD, 64.5 ± 9.2 year; 49% females). Mean LCP scores for original, 25% and 5% dose levels were 8.5 ± 1.7, 8.4 ± 1.7 (p > 0.05 vs. original dose) and 8.2 ± 1.9 (p < 0.05 vs. original dose), respectively. The proportion of correctly classified nodules with the "rule-in" approach decreased with simulated dose reduction from 58.2 to 56.1% (p = 0.34) and to 52.0% for the respective dose levels (p = 0.01). For the "rule-out" approach the respective values were 95.9%, 96.4%, and 94.4% (p = 0.12). When reducing the original dose to 25%/5%, eight/twenty-two nodules shifted to a lower, five/seven nodules to a higher malignancy risk group. CONCLUSION: CT dose reduction may affect the analyzed LCP-CNN regarding the classification of pulmonary malignancies and potentially alter pulmonary nodule management. CLINICAL RELEVANCE STATEMENT: Utilization of a "rule-out" approach with a lower malignancy risk threshold prevents underestimation of the nodule malignancy risk for the analyzed software, especially in high-risk cohorts. KEY POINTS: • LCP-CNN may be affected by CT image parameters such as noise resulting from low-dose CT acquisitions. • CT dose reduction can alter pulmonary nodule management recommendations by affecting the outcome of the LCP-CNN. • Utilization of a lower malignancy risk threshold prevents underestimation of pulmonary malignancies in high-risk cohorts.

3.
Contemp Clin Trials ; 134: 107352, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37802221

RESUMEN

Non-alcoholic fatty liver disease (NAFLD) is the liver manifestation of the metabolic syndrome with global prevalence reaching epidemic levels. Despite the high disease burden in the population only a small proportion of those with NAFLD will develop progressive liver disease, for which there is currently no approved pharmacotherapy. Identifying those who are at risk of progressive NAFLD currently requires a liver biopsy which is problematic. Firstly, liver biopsy is invasive and therefore not appropriate for use in a condition like NAFLD that affects a large proportion of the population. Secondly, biopsy is limited by sampling and observer dependent variability which can lead to misclassification of disease severity. Non-invasive biomarkers are therefore needed to replace liver biopsy in the assessment of NAFLD. Our study addresses this unmet need. The LITMUS Imaging Study is a prospectively recruited multi-centre cohort study evaluating magnetic resonance imaging and elastography, and ultrasound elastography against liver histology as the reference standard. Imaging biomarkers and biopsy are acquired within a 100-day window. The study employs standardised processes for imaging data collection and analysis as well as a real time central monitoring and quality control process for all the data submitted for analysis. It is anticipated that the high-quality data generated from this study will underpin changes in clinical practice for the benefit of people with NAFLD. Study Registration: clinicaltrials.gov: NCT05479721.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios de Cohortes , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Biomarcadores
4.
J Cardiovasc Magn Reson ; 25(1): 49, 2023 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-37587516

RESUMEN

BACKGROUND: Recent evidence underlined the importance of right (RV) involvement in suspected myocarditis. We aim to analyze the possible incremental prognostic value from RV global longitudinal strain (GLS) by CMR. METHODS: Patients referred for CMR, meeting clinical criteria for suspected myocarditis and no other cardiomyopathy were enrolled in a dual-center register cohort study. Ejection fraction (EF), GLS and tissue characteristics were assessed in both ventricles to assess their association to first major adverse cardiovascular events (MACE) including hospitalization for heart failure (HF), ventricular tachycardia (VT), recurrent myocarditis and death. RESULTS: Among 659 patients (62.8% male; 48.1 ± 16.1 years), RV GLS was impaired (> - 15.4%) in 144 (21.9%) individuals, of whom 76 (58%), 108 (77.1%), 27 (18.8%) and 40 (32.8%) had impaired right ventricular ejection fraction (RVEF), impaired left ventricular ejection fraction (LVEF), RV late gadolinium enhancement (LGE) or RV edema, respectively. After a median observation time of 3.7 years, 45 (6.8%) patients were hospitalized for HF, 42 (6.4%) patients died, 33 (5%) developed VT and 16 (2.4%) had recurrent myocarditis. Impaired RV GLS was associated with MACE (HR = 1.07, 95% CI 1.04-1.10; p < 0.001), HF hospitalization (HR = 1.17, 95% CI 1.12-1.23; p < 0.001), and death (HR = 1.07, 95% CI 1.02-1.12; p = 0.004), but not with VT and recurrent myocarditis in univariate analysis. RV GLS lost its association with outcomes, when adjusted for RVEF, LVEF, LV GLS and LV LGE extent. CONCLUSION: RV strain is associated with MACE, HF hospitalization and death but has neither independent nor incremental prognostic value after adjustment for RV and LV function and tissue characteristics. Therefore, assessing RV GLS in the setting of myocarditis has only limited value.


Asunto(s)
Insuficiencia Cardíaca , Miocarditis , Taquicardia Ventricular , Humanos , Masculino , Femenino , Miocarditis/diagnóstico por imagen , Volumen Sistólico , Estudios de Cohortes , Medios de Contraste , Gadolinio , Función Ventricular Izquierda , Función Ventricular Derecha , Valor Predictivo de las Pruebas , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Espectroscopía de Resonancia Magnética
5.
Curr Probl Cancer ; 47(2): 100968, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37336689

RESUMEN

Imaging plays an increasingly important role in the detection and characterization of prostate cancer (PC). This review summarizes the key conventional and advanced imaging modalities including multiparametric magnetic resonance imaging (MRI) and positron emission tomography (PET) imaging and tries to instruct clinicians in finding the best image modality depending on the patient`s PC-stage. We aim to give an overview of the different image modalities and their benefits and weaknesses in imaging PC. Emphasis is put on primary prostate cancer detection and staging as well as on recurrent and castration resistant prostate cancer. Results from studies using various imaging techniques are discussed and compared. For the different stages of PC, advantages and disadvantages of the different imaging modalities are discussed. Moreover, this review aims to give an outlook about upcoming, new imaging modalities and how they might be implemented in the future into clinical routine. Imaging patients suffering from PC should aim for exact diagnosis, accurate detection of PC lesions and should mirror the true tumor burden. Imaging should lead to the best patient treatment available in the current PC-stage and should avoid unnecessary therapeutic interventions. New image modalities such as long axial field of view PET/CT with photon-counting CT and radiopharmaceuticals like androgen receptor targeting radiopharmaceuticals open up new possibilities. In conclusion, PC imaging is growing and each image modality is aiming for improvement.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Tomografía de Emisión de Positrones , Imagen por Resonancia Magnética/métodos
6.
JACC Cardiovasc Interv ; 16(11): 1332-1343, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37316145

RESUMEN

BACKGROUND: The benefit related to the use of preprocedural computed tomography angiography (CCTA) on top of periprocedural echocardiography to plan percutaneous left atrial appendage closure (LAAC) procedures is still unclear. OBJECTIVES: The authors sought to evaluate the impact of preprocedural CCTA on LAAC procedural success. METHODS: In the investigator-initiated SWISS-APERO (Comparison of Amplatzer Amulet and Watchman Device in Patients Undergoing Left Atrial Appendage Closure) trial, patients undergoing echocardiography-guided LAAC were randomly assigned to receive the Amulet (Abbott) or Watchman 2.5/FLX (Boston Scientific) device across 8 European centers. According to the study protocol ongoing at the time of the procedure, the first operators had (CCTA unblinded group) or did not have (CCTA blinded group) access to preprocedural CCTA images. In this post hoc analysis, we compared blinded vs unblinded procedures in terms of procedural success defined as complete left atrial appendage occlusion as evaluated at the end of LAAC (short-term) or at the 45-day follow-up (long-term) without procedural-related complications. RESULTS: Among 219 LAACs preceded by CCTA, 92 (42.1%) and 127 (57.9%) were assigned to the CCTA unblinded and blinded group, respectively. After adjusting for confounders, operator unblinding to preprocedural CCTA remained associated with a higher rate of short-term procedural success (93.5% vs 81.1%; P = 0.009; adjusted OR: 2.76; 95% CI: 1.05-7.29; P = 0.040) and long-term procedural success (83.7% vs 72.4%; P = 0.050; adjusted OR: 2.12; 95% CI: 1.03-4.35; P = 0.041). CONCLUSIONS: In a prospective multicenter cohort of clinically indicated echocardiography-guided LAACs, unblinding of the first operators to preprocedural CCTA images was independently associated with a higher rate of both short- and long-term procedural success. Further studies are needed to better evaluate the impact of preprocedural CCTA on clinical outcomes.


Asunto(s)
Apéndice Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Estudios Prospectivos , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada
8.
Eur Radiol ; 33(10): 7226-7237, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37145149

RESUMEN

OBJECTIVES: Atrial function can be assessed using advancing cardiovascular magnetic resonance (CMR) post-processing methods: atrial feature tracking (FT) strain analysis or a long-axis shortening (LAS) technique. This study aimed to first compare the two FT and LAS techniques in healthy individuals and cardiovascular patients and then investigated how left (LA) and right atrial (RA) measurements are related to the severity of diastolic dysfunction or atrial fibrillation. METHODS: Sixty healthy controls and 90 cardiovascular disease patients with coronary artery disease, heart failure, or atrial fibrillation, underwent CMR. LA and RA were analyzed for standard volumetry as well as for myocardial deformation using FT and LAS for the different functional phases (reservoir, conduit, booster). Additionally, ventricular shortening and valve excursion measurements were assessed with the LAS module. RESULTS: The measurements for each of the LA and RA phases were correlated (p < 0.05) between the two approaches, with the highest correlation coefficients occurring in the reservoir phase (LA: r = 0.83, p < 0.01, RA: r = 0.66, p < 0.01). Both methods demonstrated reduced LA (FT: 26 ± 13% vs 48 ± 12%, LAS: 25 ± 11% vs 42 ± 8%, p < 0.01) and RA reservoir function (FT: 28 ± 15% vs 42 ± 15%, LAS: 27 ± 12% vs 42 ± 10%, p < 0.01) in patients compared to controls. Atrial LAS and FT decreased with diastolic dysfunction and atrial fibrillation. This mirrored ventricular dysfunction measurements. CONCLUSION: Similar results were generated for bi-atrial function measurements between two CMR post-processing approaches of FT and LAS. Moreover, these methods allowed for the assessment of incremental deterioration of LA and RA function with increasing left ventricular diastolic dysfunction and atrial fibrillation. A CMR-based analysis of bi-atrial strain or shortening discriminates patients with early-stage diastolic dysfunction prior to the presence of compromised atrial and ventricular ejection fractions that occur with late-stage diastolic dysfunction and atrial fibrillation. KEY POINTS: • Assessing right and left atrial function with CMR feature tracking or long-axis shortening techniques yields similar measurements and could potentially be used interchangeably based on the software capabilities of individual sites. • Atrial deformation and/or long-axis shortening allow for early detection of subtle atrial myopathy in diastolic dysfunction, even when atrial enlargement is not yet apparent. • Using a CMR-based analysis to understand the individual atrial-ventricular interaction in addition to tissue characteristics allows for a comprehensive interrogation of all four heart chambers. In patients, this could add clinically meaningful information and potentially allow for optimal therapies to be chosen to better target the dysfunction.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética , Atrios Cardíacos/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función del Atrio Izquierdo
9.
Invest Radiol ; 58(8): 602-609, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37058321

RESUMEN

ABSTRACT: Interstitial lung disease (ILD) is now diagnosed by an ILD-board consisting of radiologists, pulmonologists, and pathologists. They discuss the combination of computed tomography (CT) images, pulmonary function tests, demographic information, and histology and then agree on one of the 200 ILD diagnoses. Recent approaches employ computer-aided diagnostic tools to improve detection of disease, monitoring, and accurate prognostication. Methods based on artificial intelligence (AI) may be used in computational medicine, especially in image-based specialties such as radiology. This review summarises and highlights the strengths and weaknesses of the latest and most significant published methods that could lead to a holistic system for ILD diagnosis. We explore current AI methods and the data use to predict the prognosis and progression of ILDs. It is then essential to highlight the data that holds the most information related to risk factors for progression, e.g., CT scans and pulmonary function tests. This review aims to identify potential gaps, highlight areas that require further research, and identify the methods that could be combined to yield more promising results in future studies.


Asunto(s)
Inteligencia Artificial , Enfermedades Pulmonares Intersticiales , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Radiólogos , Pulmón/diagnóstico por imagen
11.
Int J Cardiovasc Imaging ; 39(1): 135-144, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36598693

RESUMEN

The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Cicatriz , Agua , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Aumento de la Imagen/métodos
13.
Front Cardiovasc Med ; 9: 909204, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35911559

RESUMEN

Background: Microvascular obstruction (MVO) and Late Gadolinium Enhancement (LGE) assessed in cardiac magnetic resonance (CMR) are associated with adverse outcome in patients with ST-elevation myocardial infarction (STEMI). Our aim was to analyze the diagnostic performance of segmental strain for the detection of MVO and LGE. Methods: Patients with anterior STEMI, who underwent additional CMR were enrolled in this sub-study of the CARE-AMI trial. Using CMR feature tracking (FT) segmental circumferential peak strain (SCS) was measured and the diagnostic performance of SCS to discriminate MVO and LGE was assessed in a derivation and validation cohort. Results: Forty-eight STEMI patients (62 ± 12 years old), 39 (81%) males, who underwent CMR (i.e., mean 3.0 ± 1.5 days) after primary percutaneous coronary intervention (PCI) were included. All patients presented with LGE and in 40 (83%) patients, MVO was additionally present. Segments in all patients were visually classified and 146 (19%) segments showed MVO (i.e., LGE+/MVO+), 308 (40%) segments showed LGE and no MVO (i.e., LGE+/MVO-), and 314 (41%) segments showed no LGE (i.e., LGE-). Diagnostic performance of SCS for detecting MVO segments (i.e., LGE+/MVO+ vs. LGE+/MVO-, and LGE-) showed an AUC = 0.764 and SCS cut-off value was -11.2%, resulting in a sensitivity of 78% and a specificity of 67% with a positive predictive value (PPV) of 30% and a negative predictive value (NPV) of 94% when tested in the validation group. For LGE segments (i.e., LGE+/MVO+ and LGE+/MVO- vs. LGE-) AUC = 0.848 and SCS with a cut-off value of -13.8% yielded to a sensitivity of 76%, specificity of 74%, PPV of 81%, and NPV of 70%. Conclusion: Segmental strain in STEMI patients was associated with good diagnostic performance for detection of MVO+ segments and very good diagnostic performance of LGE+ segments. Segmental strain may be useful as a potential contrast-free surrogate marker to improve early risk stratification in patients after primary PCI.

14.
JACC Case Rep ; 4(15): 929-933, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35935159

RESUMEN

We present the management of an anomalous coronary artery originating from the opposite sinus of Valsalva with comprehensive diagnostic workup including noninvasive coronary computed tomography (CT) derived fractional flow reserve (FFR) and invasive dobutamine-volume challenge-FFR/intravascular ultrasound. After surgical operation, treatment success was quantified by anatomical and functional analysis in postoperative CT. (Level of Difficulty: Advanced.).

16.
J Vasc Interv Radiol ; 33(4): 416-419.e2, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35365284

RESUMEN

The purpose of this study was to define relevant intercostal artery (ICA) anatomy potentially impacting the safety of thoracic percutaneous interventional procedures. An ICA abutting the upper rib and running in the subcostal groove was defined as the lowest risk zone for interventions requiring a supracostal needle puncture. A theoretical high-risk zone was defined by the ICA coursing in the lower half of the intercostal space (ICS), and a theoretical moderate-risk zone was defined by the ICA coursing below the subcostal groove but in the upper half of the ICS. Arterial phase computed tomography data from 250 patients were analyzed, revealing demographic variability, with high-risk zones extending more laterally with advancing age and with more cranial ribs. Overall, within the 97.5th percentile, an ICS puncture >7-cm lateral to the spinous process incurs moderate risk and >10-cm lateral incurs the lowest risk.


Asunto(s)
Costillas , Pared Torácica , Arterias/anatomía & histología , Arterias/diagnóstico por imagen , Humanos , Punciones , Costillas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
17.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-35436856

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
18.
Europace ; 24(9): 1441-1450, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35253840

RESUMEN

AIMS: No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). METHODS AND RESULTS: All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm2; P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. CONCLUSIONS: In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica , Humanos , Dispositivo Oclusor Septal/efectos adversos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/prevención & control , Trombosis/etiología , Trombosis/prevención & control , Resultado del Tratamiento
19.
J Cardiovasc Comput Tomogr ; 16(4): 309-318, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35148996

RESUMEN

BACKGROUND: Myocardial strain is an established parameter for the assessment of cardiac function and routinely derived from speckle tracking echocardiography (STE). Novel post-processing tools allow deformation imaging also by 4D cardiac computed tomography angiography (CCT). This retrospective study aims to analyze the reproducibility of CCT strain and compare it to that of STE. METHODS: Left (LV) and right ventricular (RV), and left atrial (LA) ejection fraction (EF), dimensions, global longitudinal (GLS), circumferential (GCS) and radial strain (GRS) were determined by STE and CCT feature tracking in consecutive patients with severe aortic stenosis evaluated for transcatheter aortic valve implantation. RESULTS: 106 patients (mean age 79.9 â€‹± â€‹7.8, 44.3% females) underwent CCT at a median of 3 days (IQR 0-28 days) after STE. In CCT, strain measures showed good to excellent reproducibility (intra- and inter-reader intraclass correlation coefficient ≥0.75) consistently in the LV, RV and LA. In STE, only LV GLS and LA GLS yielded good reproducibility, whereas LV GCS and LV GRS showed moderate, and RV GLS and free wall longitudinal strain (FWLS) poor reproducibility. Agreement between CCT and STE was strong for LV GLS only, while other strain features displayed moderate (LV GCS, LA GLS) or weak (LV GRS, RV GLS and FWLS) inter-modality correlation. CONCLUSION: LV, RV and LA CCT strain assessments were highly reproducible. While a strong agreement to STE was found for LV GLS, inter-modality correlation was moderate or weak for LV GCS, LV GRS, and RV and LA longitudinal strain, possibly related to poor reproducibility of STE measurements.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Función Ventricular Izquierda
20.
Eur Radiol ; 32(6): 4324-4332, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35059804

RESUMEN

OBJECTIVES: This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario. METHODS: Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location. RESULTS: The combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 ± 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence. CONCLUSIONS: The optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition. KEY POINTS: • Modification of tube voltage and tube current has a significant impact on the performance of deep learning-based CAD software. • Nodule size and composition have no significant impact on the software's performance. • The optimal tube voltage/current combination for the examined software is 80 kV/50 mAs.


Asunto(s)
Aprendizaje Profundo , Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Sensibilidad y Especificidad , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...