Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 218(5): 810-820, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34935399

RESUMEN

BACKGROUND. Increasing evidence supports the role of abbreviated MRI protocols for breast cancer detection. However, abbreviated protocols have been poorly studied in patients who are BRCA1 or BRCA2 mutation carriers. Furthermore, the need for T2-weighted sequences in abbreviated protocols remains controversial. OBJECTIVE. The purpose of this study was to compare, in the evaluation of patients with BRCA mutations, the diagnostic performance of a standard full breast MRI protocol with the performance of abbreviated protocols that included and did not include a T2-weighted sequence. METHODS. This retrospective study included 292 patients (mean age, 47.9 years) who were BRCA1 or BRCA2 mutation carriers who underwent 427 screening breast MRI examinations according to a standard full protocol who could be classified as having benign (n = 407) or malignant (n = 20) findings based on histopathology or imaging follow-up. Four readers independently assessed examinations in three separate sessions (theoretic abbreviated protocol, which included the first postcontrast acquisition; theoretic abbreviated protocol with addition of a T2-weighted sequence; and the standard full protocol) and assigned BI-RADS categories. Categories 3-5 were considered to represent positive examinations. Interreader agreement was assessed, and diagnostic performance was compared by use of pooled reader data. RESULTS. Interreader agreement on BI-RADS category, expressed as kappa values, was 0.55 for the standard, 0.45 for the abbreviated, and 0.57 for the abbreviated plus T2-weighted protocols. Pooled sensitivity was 94% for the standard, 92% for the abbreviated, and 90% for the abbreviated plus T2-weighted protocols (all p > .001). Pooled specificity was 80% for the standard, 71% for the abbreviated, and 83% for the abbreviated plus T2-weighted protocols (p < .001 for abbreviated plus T2-weighted compared with both standard and abbreviated). Pooled PPV was 19% for the standard, 14% for the abbreviated, and 20% for the abbreviated plus T2-weighted protocols (p < .001 for abbreviated compared with both standard and abbreviated). Pooled NPV was 100% for the standard, 99% for the abbreviated, and 99% for the abbreviated plus T2-weighted (all p > .001) protocols. Pooled accuracy was 80% for the standard, 73% for the abbreviated, and 83% for the abbreviated plus T2-weighted protocols (p < .001 for abbreviated compared with both standard and abbreviated plus T2-weighted). CONCLUSION. The abbreviated protocol without T2-weighted imaging had suboptimal performance. However, addition of the T2-weighted sequence yielded comparable sensitivity and accuracy and a small increase in specificity compared with the full protocol. CLINICAL IMPACT. The findings support implementation of abbreviated MRI with T2-weighted imaging for breast cancer screening of patients with BRCA mutations.


Asunto(s)
Neoplasias de la Mama , Mama , Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Mutación , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Ann Surg Oncol ; 28(11): 6024-6029, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33866472

RESUMEN

BACKGROUND: As neoadjuvant chemotherapy (NAC) for breast cancer has become more widely used, so has nipple-sparing mastectomy. A common criterion for eligibility is a 1 cm tumor-to-nipple distance (TND), but its suitability after NAC is unclear. In this study, we examined factors predictive of negative nipple pathologic status (NS-) in women undergoing total mastectomy after NAC. METHODS: Women with invasive breast cancer treated with NAC and total mastectomy from August 2014 to April 2018 at our institution were retrospectively identified. Following review of pre- and post-NAC magnetic resonance imaging (MRI) and mammograms, the association of clinicopathologic and imaging variables with NS- was examined and the accuracy of 1 cm TND on imaging for predicting NS- was determined. RESULTS: Among 175 women undergoing 179 mastectomies, 74% of tumors were cT1-T2 and 67% were cN+ on pre-NAC staging; 10% (18/179) had invasive or in situ carcinoma in the nipple on final pathology. On multivariable analysis, after adjusting for age, grade, and tumor stage, three factors, namely number of positive nodes, pre-NAC nipple-areolar complex retraction, and decreasing TND, were significant predictors of nipple involvement (p < 0.05). The likelihood of NS- was higher with increasing TND on pre- and post-NAC imaging (p < 0.05). TND ≥ 1 cm predicted NS- in 97% and 95% of breasts on pre- and post-NAC imaging, respectively. CONCLUSIONS: Increasing TND was associated with a higher likelihood of NS-. A TND ≥ 1 cm on pre- or post-NAC imaging is highly predictive of NS- and could be used to determine eligibility for nipple-sparing mastectomy after NAC.


Asunto(s)
Neoplasias de la Mama , Pezones , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/cirugía , Femenino , Humanos , Imagen por Resonancia Magnética , Mastectomía , Terapia Neoadyuvante , Estudios Retrospectivos
3.
Breast Cancer Res ; 22(1): 58, 2020 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-32466799

RESUMEN

BACKGROUND: Ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)-derived kinetic parameters have demonstrated at least equivalent accuracy to standard DCE-MRI in differentiating malignant from benign breast lesions. However, it is unclear if they have any efficacy as prognostic imaging markers. The aim of this study was to investigate the relationship between ultrafast DCE-MRI-derived kinetic parameters and breast cancer characteristics. METHODS: Consecutive breast MRI examinations between February 2017 and January 2018 were retrospectively reviewed to determine those examinations that meet the following inclusion criteria: (1) BI-RADS 4-6 MRI performed on a 3T scanner with a 16-channel breast coil and (2) a hybrid clinical protocol with 15 phases of ultrafast DCE-MRI (temporal resolution of 2.7-4.6 s) followed by early and delayed phases of standard DCE-MRI. The study included 125 examinations with 142 biopsy-proven breast cancer lesions. Ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS] and bolus arrival time [BAT]) were calculated for the entire volume of each lesion. Comparisons of these parameters between different cancer characteristics were made using generalized estimating equations, accounting for the presence of multiple lesions per patient. All comparisons were exploratory and adjustment for multiple comparisons was not performed; P values < 0.05 were considered statistically significant. RESULTS: Significantly larger MS and shorter BAT were observed for invasive carcinoma than ductal carcinoma in situ (DCIS) (P < 0.001 and P = 0.008, respectively). Significantly shorter BAT was observed for invasive carcinomas with more aggressive characteristics than those with less aggressive characteristics: grade 3 vs. grades 1-2 (P = 0.025), invasive ductal carcinoma vs. invasive lobular carcinoma (P = 0.002), and triple negative or HER2 type vs. luminal type (P < 0.001). CONCLUSIONS: Ultrafast DCE-MRI-derived parameters showed a strong relationship with some breast cancer characteristics, especially histopathology and molecular subtype.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Adulto , Anciano , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/diagnóstico por imagen , Carcinoma Lobular/patología , Carcinoma Lobular/terapia , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto Joven
4.
Eur Radiol ; 30(2): 756-766, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31468162

RESUMEN

OBJECTIVES: This study aims to evaluate ultrafast DCE-MRI-derived kinetic parameters that reflect contrast agent inflow effects in differentiating between subcentimeter BI-RADS 4-5 breast carcinomas and benign lesions. METHODS: We retrospectively reviewed consecutive 3-T MRI performed from February to October 2017, during which ultrafast DCE-MRI was performed as part of a hybrid clinical protocol with conventional DCE-MRI. In total, 301 female patients with 369 biopsy-proven breast lesions were included. Ultrafast DCE-MRI was acquired continuously over approximately 60 s (temporal resolution, 2.7-7.1 s/phase) starting simultaneously with the start of contrast injection. Four ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS], contrast enhancement ratio [CER], bolus arrival time [BAT], and initial area under gadolinium contrast agent concentration [IAUGC]) and one conventional DCE-MRI-derived kinetic parameter (signal enhancement ratio [SER]) were calculated for each lesion. Wilcoxon rank sum test or Fisher's exact test was performed to compare kinetic parameters, volume, diameter, age, and BI-RADS morphological descriptors between subcentimeter carcinomas and benign lesions. Univariate/multivariate logistic regression analyses were performed to determine predictive parameters for subcentimeter carcinomas. RESULTS: In total, 125 lesions (26 carcinomas and 99 benign lesions) were identified as BI-RADS 4-5 subcentimeter lesions. Subcentimeter carcinomas demonstrated significantly larger MS and SER and shorter BAT than benign lesions (p = 0.0117, 0.0046, and 0.0102, respectively). MS, BAT, and age were determined as significantly predictive for subcentimeter carcinoma (p = 0.0208, 0.0023, and < 0.0001, respectively). CONCLUSIONS: Ultrafast DCE-MRI-derived kinetic parameters may be useful in differentiating subcentimeter BI-RADS 4 and 5 carcinomas from benign lesions. KEY POINTS: • Ultrafast DCE-MRI can generate kinetic parameters, effectively differentiating breast carcinomas from benign lesions. • Subcentimeter carcinomas demonstrated significantly larger maximum slope and shorter bolus arrival time than benign lesions. • Maximum slope and bolus arrival time contribute to better management of suspicious subcentimeter breast lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Cinética , Persona de Mediana Edad , Estudios Retrospectivos
5.
Eur J Radiol ; 83(8): 1350-5, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24932846

RESUMEN

PURPOSE: Contrast enhanced digital mammography (CEDM) uses low energy and high energy exposures to produce a subtracted contrast image. It is currently performed with a standard full-field digital mammogram (FFDM). The purpose is to determine if the low energy image performed after intravenous iodine injection can replace the standard FFDM. METHODS: And Materials: In an IRB approved HIPAA compatible study, low-energy CEDM images of 170 breasts in 88 women (ages 26-75; mean 50.3) undergoing evaluation for elevated risk or newly diagnosed breast cancer were compared to standard digital mammograms performed within 6 months. Technical parameters including posterior nipple line (PNL) distance, compression thickness, and compression force on the MLO projection were compared. Mammographic findings were compared qualitatively and quantitatively. Mixed linear regression using generalized estimating equation (GEE) method was performed. Intraclass correlation coefficients (ICC) with 95% confidence interval (95%CI) were estimated to assess agreement. RESULTS: No statistical difference was found in the technical parameters compression thickness, PNL distance, compression force (p-values: 0.767, 0.947, 0.089). No difference was found in the measured size of mammographic findings (p-values 0.982-0.988). Grouped calcifications had a mean size/extent of 2.1cm (SD 0.6) in the low-energy contrast images, and a mean size/extent of 2.2 cm (SD 0.6) in the standard digital mammogram images. Masses had a mean size of 1.8 cm (SD 0.2) in both groups. Calcifications were equally visible on both CEDM and FFDM. CONCLUSION: Low energy CEDM images are equivalent to standard FFDM despite the presence of intravenous iodinated contrast. Low energy CEDM images may be used for interpretation in place of the FFDM, thereby reducing patient dose.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Técnica de Sustracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...