Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
JAMA Netw Open ; 6(11): e2345299, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38015504

RESUMEN

Importance: Bronchopulmonary dysplasia (BPD) is often associated with pulmonary vascular disease and secondary pulmonary hypertension (PH). The pathogenesis of BPD-associated PH (BPD-PH) is complex and involves prenatal and postnatal factors that disrupt pulmonary vascular development, and patent ductus arteriosus (PDA) is a factor potentially associated with risk of BPD-PH that has been identified in very recent studies. Objective: To explore the association of PDA with BPD-PH using a bayesian model-averaged (BMA) meta-analysis of studies. Data Sources: PubMed and Embase were searched up to April 2023. Key search terms included BPD and PH. Study Selection: Studies examining infants with gestational age 32 weeks or less and reporting data on PDA and risk of BPD-PH. Data Extraction and Synthesis: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and the Meta-Analysis of Observational Studies in Epidemiology reporting guidelines. Two independent reviewers extracted data, with a third reviewer checking for accuracy and completeness. Data pooling and effect size calculations were performed by BMA. Main Outcomes and Measures: The primary outcome was BPD-PH. BMA was used to calculate Bayes factors (BFs). The BF10 is the ratio of the probability of the data under the alternative hypothesis (H1, association of PDA with BPD-HP) over the probability of the data under the null hypothesis (H0). Results: A total of 32 studies (8513 infants) were included. BMA showed that the evidence in favor of H1 was weak for any PDA (BF10 = 2.90; 10 studies), moderate for hemodynamically significant PDA (BF10 = 3.77; 3 studies), and extreme for surgically ligated or catheter-occluded PDA (BF10 = 294.9; 16 studies). In contrast, the evidence in favor of H0 was weak for medically treated PDA (BF10 = 0.55; 6 studies). In addition, BMA found strong evidence in favor of H1 when prolonged exposure to PDA was analyzed as a dichotomous variable (BF10 = 11.80; 6 studies) and extreme evidence (BF10 = 113.60; 3 studies) when PDA exposure time was analyzed as a continuous variable. Conclusions and Relevance: In this bayesian meta-analysis, the data suggest that prolonged exposure to PDA might be associated with increased risk of pulmonary vascular disease in extremely preterm infants. This highlights the need to monitor for PH in high-risk preterm infants with prolonged exposure to PDA and to incorporate PH risk into clinical decisions regarding PDA management.


Asunto(s)
Displasia Broncopulmonar , Conducto Arterioso Permeable , Hipertensión Pulmonar , Enfermedades Vasculares , Recién Nacido , Lactante , Femenino , Embarazo , Humanos , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/epidemiología , Displasia Broncopulmonar/complicaciones , Displasia Broncopulmonar/epidemiología , Teorema de Bayes , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/etiología , Recien Nacido Extremadamente Prematuro , Estudios Observacionales como Asunto
2.
J Pers Med ; 12(7)2022 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-35887640

RESUMEN

A widely accepted concept in perinatal medicine is that boys are more susceptible than girls to complications of prematurity. However, whether this 'male disadvantage of prematurity' also involves persistent patent ductus arteriosus (PDA) has been scarcely investigated. Our aim was to conduct a systematic review and meta-analysis on studies addressing sex differences in the risk of developing PDA among preterm infants. We also investigated whether the response to pharmacological treatment of PDA differs between boys and girls. PubMed/Medline and Embase databases were searched. The random-effects male/female risk ratio (RR) and 95% confidence interval (CI) were calculated. We included 146 studies (357,781 infants). Meta-analysis could not demonstrate sex differences in risk of developing any PDA (37 studies, RR 1.03, 95% CI 0.97 to 1.08), hemodynamically significant PDA (81 studies, RR 1.00, 95% CI 0.97 to 1.02), or in the rate of response to pharmacological treatment (45 studies, RR 1.01, 95% CI 0.98 to 1.04). Subgroup analysis and meta-regression showed that the absence of sex differences was maintained over the years and in different geographic settings. In conclusion, both the incidence of PDA in preterm infants and the response rate to pharmacological treatment of PDA are not different between preterm boys and girls.

3.
Antioxidants (Basel) ; 10(9)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34573122

RESUMEN

A widely accepted concept is that boys are more susceptible than girls to oxidative stress-related complications of prematurity, including bronchopulmonary dysplasia (BPD), retinopathy of prematurity (ROP), necrotizing enterocolitis (NEC), intraventricular hemorrhage (IVH), and periventricular leukomalacia (PVL). We aimed to quantify the effect size of this male disadvantage by performing a systematic review and meta-analysis of cohort studies exploring the association between sex and complications of prematurity. Risk ratios (RRs) and 95% CIs were calculated by a random-effects model. Of 1365 potentially relevant studies, 41 met the inclusion criteria (625,680 infants). Male sex was associated with decreased risk of hypertensive disorders of pregnancy, fetal distress, and C-section, but increased risk of low Apgar score, intubation at birth, respiratory distress, surfactant use, pneumothorax, postnatal steroids, late onset sepsis, any NEC, NEC > stage 1 (RR 1.12, CI 1.06-1.18), any IVH, severe IVH (RR 1.28, CI 1.22-1.34), severe IVH or PVL, any BPD, moderate/severe BPD (RR 1.23, CI 1.18-1.27), severe ROP (RR 1.14, CI 1.07-1.22), and mortality (RR 1.23, CI 1.16-1.30). In conclusion, preterm boys have higher clinical instability and greater need for invasive interventions than preterm girls. This leads to a male disadvantage in mortality and short-term complications of prematurity.

4.
Front Pediatr ; 9: 647018, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33643980

RESUMEN

Background: Amino acids are increasingly recognized as bioactive molecules in numerous physiological and pathophysiological pathways. The non-essential amino acid glutamate is vasoactive in the rat ductus arteriosus (DA) and a decrease in its levels within the 1st days of life has been associated with the presence of patent DA (PDA) in extremely preterm infants. However, these findings have not been confirmed in other studies. Objective: To investigate the possible association between amino acid concentrations in the 1st day of life and the presence of PDA in a cohort of 121 newborns with gestational age (GA) below 30 weeks and birth weight (BW) below 1,500 g. Methods: Plasma samples were collected 6-12 h after birth and amino acid concentrations were determined by tandem mass spectrometry. Besides PDA, we analyzed the potential association of amino acid concentrations with infant sex, small for GA (SGA, defined as BW < third percentile), antenatal corticosteroids, chorioamnionitis, and preeclampsia. Group differences were analyzed by ANOVA adjusted for GA and BW. A Bonferroni significance threshold of P < 0.0024 was used to correct for multiple testing. Results: PDA was found in 48 of the 121 infants examined. We observed higher mean levels of glutamate in infants with PDA (147.0 µmol/L, SD 84.0) as compared with those without (106.7 µmol/L, SD 49.1, P = 0.0006). None of the other amino acid concentrations in the PDA group reached the level of statistical significance that was pre-set to correct for multiple comparisons. Glutamate levels were not significantly affected by infant sex, being SGA, or by exposure to antenatal corticosteroids, clinical chorioamnionitis, or preeclampsia. Conclusion: Our study not only does not confirm the previous findings of low glutamate levels in preterm infants with PDA, but we have even found elevated glutamate concentrations associated with PDA. Nevertheless, despite the high statistical significance, the difference in glutamate levels may lack clinical significance or may be an epiphenomenon associated with the particular clinical condition of infants with PDA.

5.
Front Pediatr ; 8: 160, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32411634

RESUMEN

Epidemiological evidence and animal studies support that intrauterine exposure to tobacco smoke disturbs lung development and has a negative effect in the pulmonary health of the offspring. Individual studies suggest an association between fetal exposure to maternal smoking and risk of developing bronchopulmonary dysplasia (BPD). However, this association has not yet been systematically investigated. We aimed to conduct a systematic review of studies reporting on tobacco smoking during pregnancy as potential risk factor for BPD. PubMed/MEDLINE and EMBASE databases were searched. BPD was defined as requirement of supplemental oxygen on postnatal day 28 (BPD28; all BPD), at the postmenstrual age (PMA) of 36 weeks (BPD36; moderate/severe BPD), or as requirement of more than 30% oxygen and/or positive pressure at 36 weeks PMA (severe BPD). Pooled risk ratios (RR) and 95% confidence intervals (CI) were calculated using a random-effects model. Of 2,894 potentially relevant studies, 33 met the inclusion criteria. The included studies evaluated 171,772 infants and included 30,445 cases of exposure to maternal smoking and 25,340 cases of BPD of any severity. Meta-analysis showed a significant association between tobacco smoking during pregnancy and BPD36 (17 studies, RR 1.126, 95% CI 1.008-1.259, p = 0.036), but could not demonstrate a significant association between tobacco smoking during pregnancy and BPD28 (16 studies, RR 1.021, 95% CI 0.924-1.129, p = 0.681), or severe BPD (3 studies, RR 1.143, 95% CI 0.528-2.478, p = 0.734). In conclusion, our data suggest that tobacco smoking during pregnancy increases the risk of moderate/severe BPD. Our results highlight the detrimental effects of tobacco smoking and reinforce the hypothesis of the involvement of prenatal insults in the etiopathogenesis of BPD.

6.
Front Pediatr ; 8: 45, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32133331

RESUMEN

The etiology of necrotizing enterocolitis (NEC) is multifactorial and an underlying genetic predisposition to NEC is increasingly being recognized. A growing number of studies identified single nucleotide polymorphisms (SNPs) of selected genes with potential biological relevance in the development of NEC. However, few of these genetic studies have been replicated in validation cohorts. We aimed to confirm in a cohort of 358 preterm newborns (gestational age <30 weeks, 26 cases of NEC ≥ Bell stage II) the association with NEC of three candidate SNPs: the vascular endothelium growth factor (VEGF) C-2578A polymorphism (rs699947), the interleukin (IL)-18 C-607A polymorphism (rs1946518), and the IL-4 receptor α-chain (IL-4Rα) A-1902G polymorphism (rs1801275). We observed that allele and genotype frequencies of the three SNPs did not significantly differ between the infants with and without NEC. In contrast, the minor G-allele of the IL-4Rα A-1902G polymorphism was significantly less frequent in the group of 51 infants with the combined outcome NEC or death before 34 weeks postmenstrual age than in the infants without the outcome (0.206 vs. 0.331, P = 0.01). In addition, a significant negative association of the G-allele with the combined outcome NEC or death was found using the dominant (adjusted odds ratio, aOR: 0.44, 95% CI 0.21-0.92), recessive (aOR 0.15, 95% CI 0.03-0.74), and additive (aOR 0.46, 95% CI 0.26-0.80) genetic models. In conclusion our study provides further evidence that a genetic variant of the IL-4Rα gene may contribute to NEC.

7.
J Pediatr Nurs ; 49: e36-e41, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31439356

RESUMEN

PURPOSE: To conduct a national survey to assess practice, knowledge, barriers, and perceptions regarding oxygen saturation (SpO2) target limits among Dutch neonatal intensive care unit (NICU) nurses. DESIGN AND METHODS: Cross-sectional, web-based survey among 667 nurses from 9 level 3 Dutch NICUs. Part of the questions were based on a clinical scenario (28-weeks preterm infant, treated with CPAP, FiO2 0.4). RESULTS: 328 (53.6%) nurses responded to the survey. Of these, 281 (85.7%) reported to know the local policy of SpO2 target limits, and 261 (79.6%) and 244 (74.4%) rightly identified the lower and upper limit, respectively. Six NICUs recently increased their lower SpO2 limit and for 62.0% of their nurses this led to a significant alarm increase. For the majority of the respondents, the baby from the clinical scenario would spend <10% of the time outside the lower or upper SpO2 limits. Automated oxygen control systems were considered a good idea by 59.2% of the respondents, but 53.9% considered allowing parents to participate in FiO2 titration a bad or very bad idea. CONCLUSIONS: The majority of the respondents identified their unit's policy-specified SpO2 target limits and reported that the increase in SpO2 target limits may have led to more alarms. Titration of FiO2 is a part of care that respondents were reluctant to share with parents. PRACTICE IMPLICATIONS: A potential increase in the number of SpO2 alarms may lead to alarm fatigue. Although family-centered care philosophy is widely accepted across Dutch NICUs, there are still barriers to overcome.


Asunto(s)
Enfermería de Cuidados Críticos/métodos , Recien Nacido Prematuro , Oximetría/normas , Consumo de Oxígeno/fisiología , Terapia por Inhalación de Oxígeno/enfermería , Sistemas Recordatorios/normas , Automatización , Competencia Clínica , Estudios Transversales , Femenino , Edad Gestacional , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Cuidado Intensivo Neonatal/métodos , Masculino , Países Bajos , Percepción , Encuestas y Cuestionarios
8.
Neonatology ; 112(4): 324-329, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28768288

RESUMEN

BACKGROUND: Barriers to widespread implementation of pulse oximetry screening of critical congenital heart defects (CCHD) in newborns include increasing trends of out-of-hospital births and cost of equipment. In recent years, smartphone-compatible pulse oximeters have appeared on the market, but the validity of such devices in the setting of CCHD screening has not been evaluated. OBJECTIVES: To compare the performance in CCHD screening of a smartphone-paired pulse oximeter (Masimo iSpO2-Rx™) and a hospital-grade pulse oximeter (Masimo Radical-7™). METHODS: Preductal (right hand) and postductal (either foot) saturations were determined in a population of 201 term newborns by 2 independent teams, one using the Radical-7 and the other using the iSpO2-Rx. Bland-Altman analysis was applied to calculate mean bias and 95% limits of agreement between the 2 pulse oximeters. RESULTS: For the preductal oxygen saturation, the mean bias (Radical-7 minus iSpO2-Rx) was -0.08 (SD 1.76) and the lower and upper limits of agreement were -3.52 and 3.36, respectively. For the postductal oxygen saturation, the mean bias was -0.11 (SD 1.68) and the lower and upper limits of agreement were -3.49 and 3.18, respectively. In addition, the iSpO2-Rx provided reliable measurements of saturations below 95% in a group of 12 infants admitted to the neonatal intensive care unit. CONCLUSIONS: Our data suggest that CCHD screening with the Masimo iSpO2-Rx is feasible and accurate. The use of reliable smartphone-paired pulse oximeters may contribute to the extension of CCHD screening to home births and low resource settings.


Asunto(s)
Diagnóstico por Computador/instrumentación , Cardiopatías Congénitas/diagnóstico , Aplicaciones Móviles , Tamizaje Neonatal/instrumentación , Oximetría/instrumentación , Oxígeno/sangre , Teléfono Inteligente , Biomarcadores/sangre , Enfermedad Crítica , Cardiopatías Congénitas/sangre , Humanos , Recién Nacido , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
9.
Antioxid Redox Signal ; 27(17): 1432-1438, 2017 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-28375031

RESUMEN

The C242T polymorphism of CYBA (cytochrome B-245 alpha chain), the gene encoding the p22phox subunit of nicotinamide adenine dinucleotide phosphate (NADPH) oxidase, has been linked to several conditions in which oxidative stress plays a pathogenic role. We investigated in a cohort of 451 preterm infants [gestational age (GA) ≤30 weeks] the association of the polymorphism with the risk of developing neonatal respiratory distress syndrome (RDS), retinopathy of prematurity (ROP), bronchopulmonary dysplasia (BPD), necrotizing enterocolitis, patent ductus arteriosus, or intraventricular hemorrhage. We observed a significant association of the TT/CT genotype with RDS [odds ratio (OR) 2.34, 95% confidence interval (95% CI) 1.28-3.90], ROP (OR 1.72, 95% CI 1.05-2.80), and BPD (OR 1.60, 95% CI 1.05-2.43). When this dominant model was adjusted to account for GA, birth weight, and sex, it remained significant for the three outcomes. This study is the first to address the association of a polymorphism related to the NADPH family with oxidative stress-related complications of prematurity. Since p22phox is essential for reactive oxygen species production by NADPH oxidase, we hypothesize that genetic variations in the protein may lead to differences in susceptibility to oxidative stress-induced damage in preterm infants. Antioxid. Redox Signal. 27, 1432-1438.


Asunto(s)
Enfermedades del Prematuro/genética , NADPH Oxidasas/genética , Polimorfismo de Nucleótido Simple , Displasia Broncopulmonar/genética , Citosina/metabolismo , Femenino , Humanos , Lactante , Recien Nacido Prematuro , Masculino , Síndrome de Dificultad Respiratoria del Recién Nacido/genética , Retinopatía de la Prematuridad/genética , Tirosina/genética
10.
Eur J Pediatr ; 176(1): 51-56, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27853941

RESUMEN

The optimum range of pulse oximeter oxygen saturation (SpO2) for preterm infants remains controversial. Between November 2015 and February 2016, we conducted a web-based survey aimed to investigate the current and former practices on SpO2 targets in European neonatal intensive care units (NICUs). We obtained valid responses from 193 NICUs, treating 8590 newborns ≤28 weeks per year, across 27 countries. Forty different saturation ranges were reported, ranging from 82-93 to 94-99%. The most frequently utilized SpO2 ranges were 90-95% (28%), 88-95% (12%), 90-94% (5%), and 91-95% (5%). A total of 156 NICUs (81%) changed their SpO2 limits over the last 10 years. The most frequently reported former limits were 88-92% (18%), 85-95% (9%), 88-93 (7%), and 85-92% (6%). The NICUs that increased their SpO2 ranges expected to obtain a reduction in mortality. A 54% of the NICUs found the scientific evidence supporting their SpO2 targeting policy strong or very strong. CONCLUSION: We detected a high degree of heterogeneity in pulse oximeter SpO2 target limits across European NICUs. The currently used limits are 3 to 5% higher than the former limits, and the most extreme limits, such as lower below 85% or upper above 96%, have almost been abandoned. What is Known: • For preterm infants requiring supplemental oxygen, the optimum range of pulse oximeter oxygen saturation (SpO 2 ) to minimize organ damage, without causing hypoxic injury, remains controversial. What is New: • This survey highlights the lack of consensus regarding SpO 2 target limits for preterm infants among European neonatal intensive care units (NICUs). We detected 40 different SpO 2 ranges, and even the most frequently reported range (i.e., 90-95%) was used in only 28% of the 193 respondent NICUs. • A total of 156 NICUs (81%) changed their SpO 2 limits over the last 10 years. The currently used limits are 3 to 5% higher than the former limits, and the most extreme limits, such as lower below 85% or upper above 96%, have almost been abandoned.


Asunto(s)
Oximetría/métodos , Oxígeno/sangre , Europa (Continente) , Humanos , Hiperoxia/prevención & control , Hipoxia/prevención & control , Recién Nacido , Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Oximetría/normas , Guías de Práctica Clínica como Asunto , Valores de Referencia , Encuestas y Cuestionarios
11.
Sci Rep ; 6: 36999, 2016 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-27833157

RESUMEN

The p.Thr1406Asn (rs1047891) polymorphism of the carbamoyl-phosphate synthetase 1 (CPS1) gene has been linked to functional consequences affecting the downstream availability of the nitric oxide precursor L-arginine. L-arginine concentrations are decreased in preterm infants with necrotizing enterocolitis (NEC). In this multicenter prospective study, we investigated the association of the p.Thr1406Asn polymorphism with NEC in 477 preterm infants (36 cases of NEC) from 4 European neonatal intensive care units (Maastricht, Las Palmas de Gran Canaria, Mantova, and Milan). Allele and genotype frequencies of the p.Thr1406Asn polymorphism did not significantly differ between the infants with and without NEC. In contrast, the minor A-allele was significantly less frequent in the group of 64 infants with the combined outcome NEC or death before 34 weeks of corrected gestational age than in the infants without the outcome (0.20 vs. 0.31, P = 0.03). In addition, a significant negative association of the A-allele with the combined outcome NEC or death was found using the dominant (adjusted odds ratio, aOR: 0.54, 95% CI 0.29-0.99) and the additive (aOR 0.58, 95% CI 0.36-0.93) genetic models. In conclusion, our study provides further evidence that a functional variant of the CPS1 gene may contribute to NEC susceptibility.


Asunto(s)
Carbamoil-Fosfato Sintasa (Amoniaco)/genética , Enterocolitis Necrotizante/genética , Enfermedades del Prematuro/genética , Polimorfismo de Nucleótido Simple , Alelos , Arginina/metabolismo , Comorbilidad , Enterocolitis Necrotizante/enzimología , Enterocolitis Necrotizante/epidemiología , Femenino , Genes Dominantes , Genotipo , Edad Gestacional , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Enfermedades del Prematuro/enzimología , Enfermedades del Prematuro/epidemiología , Unidades de Cuidado Intensivo Neonatal , Italia/epidemiología , Masculino , Modelos Genéticos , Países Bajos/epidemiología , Estudios Prospectivos , Riesgo , España/epidemiología , Resultado del Tratamiento
12.
Int J Mol Sci ; 16(1): 19-39, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25546385

RESUMEN

Endogenously produced inhibitors of nitric oxide (NO) synthase, in particular asymmetric dimethylarginine (ADMA), are currently considered of importance in various disease states characterized by reduced NO availability. We investigated the association between plasma levels of ADMA, symmetric dimethylarginine (SDMA), L-arginine, and citrulline and perinatal factors and outcome in 130 preterm (gestational age ≤ 30 weeks) very low birth weight (VLBW, < 1500 g) infants. Plasma samples were collected 6-12 h after birth. We did not find significant correlations between ADMA, SDMA, L-arginine, and citrulline levels and gestational age or birth weight. However, the arginine:ADMA ratio (AAR, a better indicator of NO availability than either arginine or ADMA separately) was positively correlated with gestational age. ADMA and arginine levels were not significantly different between males and females but males showed a negative correlation between ADMA levels and gestational age. Perinatal factors such as preeclampsia, chrorioamnionitis, prolonged rupture of membranes, or form of delivery did not significantly alter dimethylarginine levels or AAR. In contrast, the AAR was significantly reduced in the infants with respiratory distress, mechanical ventilation, and systemic hypotension Therefore, our data suggest that altered NO availability may play a role in the respiratory and cardiovascular adaptation in preterm VLBW infants.


Asunto(s)
Arginina/sangre , Enfermedades del Prematuro/sangre , Recien Nacido Prematuro/sangre , Recién Nacido de muy Bajo Peso/sangre , Arginina/análogos & derivados , Peso al Nacer , Corioamnionitis/sangre , Corioamnionitis/epidemiología , Citrulina/sangre , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro/fisiología , Enfermedades del Prematuro/epidemiología , Recién Nacido de muy Bajo Peso/fisiología , Masculino , Óxido Nítrico/sangre , Preeclampsia/sangre , Preeclampsia/epidemiología , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...