Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Animals (Basel) ; 14(10)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38791622

RESUMEN

In this multicenter, prospective, observational study, abdominal aortic flow was examined with pulsed-wave Doppler ultrasound in dogs with a left-to-right shunting patent ductus arteriosus (PDA) and in apparently healthy dogs. Forty-eight dogs with a PDA and 35 controls were included. In the dogs with a PDA, 37/48 had hemodynamically significant PDAs (hsPDAs) while 11/48 had non-hsPDAs, based on the presence or absence of echocardiographic signs of left-sided volume overload, respectively. In 12 dogs (4/35 control dogs, 7/37 dogs with an hsPDA and 1/11 dogs with a non-hsPDA), the diastole was too short to visualize the end-diastolic flow. Antegrade end-diastolic flow was observed in 30/35 controls and 6/11 dogs with a non-hsPDA. Absent end-diastolic flow was observed in 1/35 control dogs and 3/11 dogs with a non-hsPDA. Retrograde end-diastolic flow was observed in 30/37 dogs with an hsPDA and 1/11 dogs with a non-hsPDA. Twenty-one dogs (15 with an hsPDA and 6 with a non-hsPDA) were reassessed after PDA closure, and, in 19/21, end-diastolic flow was visualized: 17/19 showed an antegrade flow, 1/19 an absent flow and 1/19 a retrograde flow. Sensitivity and specificity of retrograde end-diastolic flow for detection of hsPDAs were 100% and 90%, respectively. In conclusion, ultrasonographic assessment of abdominal aortic flow was feasible in dogs with PDA. However, end-diastolic flow was not always visualized. The presence of a retrograde end-diastolic flow was an accurate finding for discriminating hsPDAs and non-hsPDAs.

2.
J Vet Intern Med ; 35(1): 98-106, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33242371

RESUMEN

BACKGROUND: Minimally invasive transcatheter occlusion using Amplatz canine duct occluder (ACDO) is the treatment of choice for dogs with left-to-right shunting patent ductus arteriosus (PDA). However, in small dogs the femoral artery diameter is often too small to accommodate the guiding catheter required for ACDO deployment. OBJECTIVE: Describe the effectiveness of transarterial implantation of Amplatzer Vascular Plug 4 (AVP-4), the only self-expandable nitinol mesh occlusion device which can be implanted through a 4 French diagnostic catheter, in small dogs with left-to-right shunting PDA. ANIMALS: Seven client-owned dogs. METHODS: Descriptive case series. Dogs with hemodynamically relevant left-to-right shunting PDA and a femoral artery diameter less than 2.0 mm measured preoperatively with ultrasonography were prospectively enrolled. RESULTS: Angiography after releasing the device showed complete immediate PDA closure in 5 dogs, where the manufacturers' recommendation were strictly followed (30%-50% device oversizing of the ductal ampulla's diameter). Trivial residual flow on angiography in the 6th dog, whose device was slightly undersized, had resolved on echocardiography within 2 hours after placement. Marked device undersizing in the 7th dog resulted in severe residual shunting, which necessitated the addition of a coil. In this dog, the AVP-4 embolized into the pulmonary artery within 2 weeks after placement. CONCLUSIONS AND CLINICAL IMPORTANCE: Transarterial implantation of AVP-4 is a safe, effective and technically easy procedure for PDA occlusion in small dogs and offers a valuable alternative to coil implantation. Accurate PDA measurement and device sizing is essential to prevent residual shunting, inadvertent device embolization, and protrusion of the device into the aorta.


Asunto(s)
Enfermedades de los Perros , Conducto Arterioso Permeable , Angiografía/veterinaria , Animales , Cateterismo Cardíaco/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía , Perros , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Conducto Arterioso Permeable/veterinaria , Ecocardiografía , Arteria Pulmonar , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA